Cellco Partnership

1906-EX-ST-2018

Status: Pending

N/A
2018-11-14

Documents and Communications: [refresh]

DescriptionCategoryDate
E-Mail generated [Nov 14 2018]Correspondence2018-11-14
Exhibit AText Documents2018-11-14
E-Mail generated [Nov 15 2018]Correspondence2018-11-15
Incoming generated [Nov 30 2018]Correspondence2018-11-30
Grant E-mail Notification generated [Dec 18 2018]Correspondence2018-12-18
E-Mail generated [Nov 14 2018]Correspondence2018-11-14
E-Mail generated [Nov 15 2018]Correspondence2018-11-15
Incoming generated [Nov 30 2018]Correspondence2018-11-30
Grant E-mail Notification generated [Dec 18 2018]Correspondence2018-12-18
Exhibit AText Documents2018-11-14
Application Form:
OET Special Temporary Authority Report
FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR SPECIAL TEMPORARY AUTHORITY

Applicant Name
Name of Applicant:  Cellco Partnership

Address
Attention: Hariprasad Sanka
Street Address: One Verizon Way - VC4 2 E 237
P.O. Box:
City: Basking Ridge
State: NJ
Zip Code: 07920
Country:
E-Mail Address: [email protected]

Best Contact
Give the following information of person who can best handle inquiries pertaining to this application:  
Last Name: Sanka
First Name: Hariprasad
Title: Senior Manager-Prod Mgt/Dev
Phone Number: 908-559-1087

Explanation
Please explain in the area below why an STA is necessary:
Periodic testing over a 6-month period

Purpose of Operation
Please explain the purpose of operation:  The purpose of the proposed operations is to conduct an internal market trial of new communications equipment systems compliant with Part 5, Subpart H, Rule 5.602. We will be operating at low power and within a very limited area. See Exhibit A.

Information
Callsign: WN9XTI
Class of Station: MO
Nature of Service: Experimental

Requested Period of Operation
Operation Start Date: 12/18/2018
Operation End Date: 05/02/2019

Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:  
Manufacturer Model Number No. Of Units Experimental
Samsung NA 20 No

Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form): Gregory M Romano
Title of Applicant (if any): Vice President - Regulatory Affairs
Date: 2018-11-07 00:00:00.0

Station Location
City State Latitude Longitude Mobile Radius of Operation
Minneapolis Minnesota North  44  58  38 West  93  15  56 Minneapolis, MN 2.00
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:   10.00
(b) Orientation in horizontal plane:   90.00
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.50000000-28.35000000 GHz MO N/A 122.000000 mW P 787MG7D QPSK, 16QAM, 64QAM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.50000000-28.35000000 GHz MO N/A 122.000000 mW P 789MW7D QPSK, 16QAM, 64QAM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.50000000-28.35000000 GHz MO N/A 122.000000 mW P 95M3W7D QPSK, 16QAM, 64QAM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.50000000-28.35000000 GHz MO N/A 122.000000 mW P 95M6G7D QPSK, 16QAM, 64QAM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2412.00000000-2462.00000000 MHz MO N/A 30.490000 mW P N0N Digital
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5150.00000000-5350.00000000 MHz MO N/A 10.980000 mW P N0N Digital
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 5470.00000000-5600.00000000 MHz MO N/A 10.980000 mW P N0N Digital
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5650.00000000-5850.00000000 MHz MO N/A 10.980000 mW P N0N Digital

City State Latitude Longitude Mobile Radius of Operation
Bloomington Minnesota North  44  48  26 West  93  22  32 Bloomington, MN 2.00
Datum:  NAD 83
Is a directional antenna (other than radar) used?   No
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:  
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.50000000-28.35000000 GHz MO N/A 122.000000 mW P 787MG7D QPSK, 16QAM, 64QAM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.50000000-28.35000000 GHz MO N/A 122.000000 mW P 789MW7D QPSK, 16QAM, 64QAM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.50000000-28.35000000 GHz MO N/A 122.000000 mW P 95M3W7D QPSK, 16QAM, 64QAM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.50000000-28.35000000 GHz MO N/A 122.000000 mW P 95M6G7D QPSK, 16QAM, 64QAM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2412.00000000-2462.00000000 MHz MO N/A 30.490000 mW P N0N Digital
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5150.00000000-5350.00000000 MHz MO N/A 10.980000 mW P N0N Digital
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5470.00000000-5600.00000000 MHz MO N/A 10.980000 mW P N0N Digital
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5650.00000000-5850.00000000 MHz MO N/A 10.980000 mW P N0N Digital

40714

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC