Attachment Exhibit B

This document pretains to SES-STA-20160520-00446 for Special Temporal Authority on a Satellite Earth Station filing.

IBFS_SESSTA2016052000446_1136630

Satellite On The Move Terminal
         MICROSAT KA-BAND SYSTEM
                                March 24, 2016




                                 Proprietary Notice

       The information and ideas contained herein are proprietary to GetSAT
 communications Ltd. and shall not be duplicated or disclosed outside the receiving
    organization or the receiving organization's potential customer without prior
   written approval from GetSAT communications Ltd., nor used by the receiving
   organization or any of its subsidiaries or affiliates, for any purpose other than
                 evaluation of the ideas and work contained herein.


      GETSAT communications LTD., 514968718, INFO@GETSAT.COM


Contents
1.     MICROSAT - ON THE MOVE TERMINAL ...................................................................................... 2
     1.1      GENERAL SYSTEM INTRODUCTION .............................................................................................. 2
     1.2      MICROSAT MAIN FEATURES ..................................................................................................... 2
2.     MICROSAT TECHNICAL SPECIFICATIONS ................................................................................... 3
     2.1      MICROSAT DESCRIPTION ......................................................................................................... 3
     2.1.1    GENERAL .................................................................................................................................. 3
     2.1.2        RF PERFORMANCE ................................................................................................................. 4
     2.1.3    ENVIRONMENTAL ...................................................................................................................... 4
     2.1.4        MICROSAT MECHANICAL DIMENSIONS .................................................................................. 5
     2.1.5    MICROSAT SYSTEM SCHEME ...................................................................................................... 7
     2.1.6        ANTENNA PATTERNS ........................................................................................................... 10
     2.1.7    CONTROL APPLICATION TECHNICIAN GRAPHICAL INTERFACE (GUI) ............................................. 11
     2.1.8        OPERATION MODES ............................................................................................................. 12
     2.1.9        POINTING FLOW CHART ........................................................................................................ 13



List of tables:
TABLE 1: MICROSAT GENERAL PARAMETERS............................................................................................... 3
TABLE 2: MICROSAT RF PERFORMANCE ..................................................................................................... 4
TABLE 3: MICROSAT ENVIRONMENTAL ....................................................................................................... 4
TABLE 4: MICROSAT MDM ICD ................................................................................................................ 8



List of figures:
FIGURE 1: MICROSAT ................................................................................................................................ 3
FIGURE 2: MICROSAT MECHANICAL DIMENSIONS ........................................................................................ 5
FIGURE 3: MICROSAT MECHANICAL INTERFACE ........................................................................................... 5
FIGURE 4: MICROSAT INTERNAL PARTS ...................................................................................................... 6
FIGURE 5: MICROSAT SYSTEM BLOCK DIAGRAM .......................................................................................... 7
FIGURE 6: MICROSAT KA ANTENNA PATTERN ........................................................................................... 10
FIGURE 7: SYSTEM GUI APPLICATION ........................................................................................................ 11
FIGURE 8: SYSTEM OPERATION MODES ..................................................................................................... 12
FIGURE 9: SYSTEM POINTING FLOW CHART ................................................................................................ 13

 1
                                                             Business sensitive


1. MICROSAT - ON THE MOVE TERMINAL

    1.1 GENERAL SYSTEM INTRODUCTION

       The MicroSAT is a lightweight portable “on-the-move” satellite terminal solution. It
       is designed for compact installation, and fully autonomous operation for transmit and
       receive of high bandwidth data.

       The system is utilizing an innovative high performance panel antenna, with a full
       control over elevation and azimuth to allow automatic operation for the position and
       tracking.

       This results in a low-weight / low profile antenna with superior stiffness and high
       performance to support multiple applications requiring “On-The-Move”
       communications.

       The system was designed according to FCC 225, MIL STD 461.

       GETSAT communications LTD. is ISO9001 certified.


    1.2 MICROSAT MAIN FEATURES

              Aluminum Gimbal
              Lightweight
              Low profile
              Modem / Data-link agnostic
              GPS / Compass
              High Accuracy Pointing
              Easy Integration to any platform
              Scalable (Different Antennas)
              Low power consumption
              Plug & Play operation after pre configuration




2
                                     Business sensitive


2. MICROSAT TECHNICAL SPECIFICATIONS




                                       FIGURE 1: MICROSAT

    2.1 MICROSAT DESCRIPTION

    2.1.1       GENERAL

                              TABLE 1: MICROSAT GENERAL PARAMETERS

                          System                                Values
            Azimuth                         0÷360°, 200°/s
            Elevation                       0° to 90°, 200°/s
            Control Technique               Combined IMU/RSSi/GPS
            Tracking Accuracy               <0.2° (<0.8dB)
            Initial Acquisition Time        <30 sec
            Re-Acquisition time             <100ms (depends on modem)
            Management                      GUI via RS-232 / Ethernet
            Power Input                     9- 50VDC
            MicroSAT Power Consumption      <15w (Rx only)
            Interfaces                      GPS, RS-232, Ethernet, TX/RX, Other
            Weight                          3.0 kg (6.6 lb)/ Ground 4.0kg (8.8 lb)


3
                                        Business sensitive


    2.1.2   RF PERFORMANCE

                            TABLE 2: MICROSAT RF PERFORMANCE

                         Parameter                            Values
            Tx Frequency                           29÷31 or 27.5÷30GHz
            Rx Frequency                         18.7÷21.2 or 17.5÷20GHz
            Gain Tx                                           34 dBi
            Gain Rx                                           32 dBi
            G/T                                              7.8 dB/K
            Beam Width                                    AZ 2.6° EL 4.5°
            Polarization                       RHCP/LHCP (co-pol/cross-pol)
            Power Handling                                     50w
            Tx/Rx isolation                                   >60dB
            Panel Size                             248x135mm (9.8x5.3”)
            Radome Rx loss                                    0.2dB
            Radome Tx loss                                    0.4dB




    2.1.3   ENVIRONMENTAL

                              TABLE 3: MICROSAT ENVIRONMENTAL

                         Parameter                            Values
            Shock                                25g , 11ms, ½ sine (tested)
                                                6g RMS (mil-std-810G 514.6)
            Vibration
                                                             (tested)
            Temperature                            (-40)÷(+60)°C (tested)
            Altitude                                -1.5K to 40K ft AMSL
            Rain                                      Radome Sealing
            RH[%]                                               95




4
                                     Business sensitive


    2.1.4   MICROSAT MECHANICAL DIMENSIONS




                    FIGURE 2: MICROSAT MECHANICAL DIMENSIONS




                     FIGURE 3: MICROSAT MECHANICAL INTERFACE




5
                                Business sensitive


    FIGURE 4: MICROSAT INTERNAL PARTS




6
            Business sensitive


    2.1.5         MICROSAT SYSTEM SCHEME

      Rotating Head (Elevation Unit )




         Encoder


                                                                                       Panel
                                         Pos Fb                                       Antenna
        Planetary
          Gear
                                                                     TX / RX

         Digital
        Servo/DC
          motor                     PWM El
          6/12v
        (EL Axis)




                                                                     Rotary
                                             Slip ring
                                                                      Joint                TX / RX
     Static Base (Azimuth Unit )



            Encoder      Pos FB                                             GPS
                                          RX                                              GPS Antenna
                                                                           + Ant


         Planetary
                                                   Main Controller
           Gear
                                                        Board
                                                (Motor Ctrl + IMU + ICD)
          Digital
         Servo/DC                        AZ/EL                                     Command & Status (RS232/IP)
                        PWM AZ                                         Power
          motor                           IMU
                                                                       Supply
           6/12v                        (3 Axis)                                       Power IN (9 to 50V)
         (AZ Axis)




                                  FIGURE 5: MICROSAT SYSTEM BLOCK DIAGRAM




7
                                                   Business sensitive


J1: The MicroSAT is provided with 25 pin MDM plug:

                              TABLE 4: MICROSAT MDM ICD

     Connector              Signal name           I/O     Pin No.         Description
                      Power IN (DC 12 - 48V)         I      1            DC Power IN
                      Power IN (DC 12 - 48V)         I      2            DC Power IN
                      Power IN (DC 12 - 48V)         I      3            DC Power IN
                                                                     Ground and DC Power
                               GND                   I      4
                                                                             RTN
                                                                     Ground and DC Power
                               GND                   I      5
                                                                             RTN
                                                                     Ground and DC Power
                               GND                   I      6
                                                                             RTN
                            ETH_A_TX+             O         7         Ethernet port A Tx+
                            ETH_A_TX -            O         8         Ethernet port A Tx -
                                                                     Ground and DC Power
                               GND                   I      9
                                                                             RTN
                            ETH_B_TX+             O         10        Ethernet port B Tx+
                            ETH_B_TX-             O         11        Ethernet port B Tx-
 MDM-25SCBR-P-T                                                       BUC RS232/422/485
                         DATA_RS485_IN_P          IO        12
                                                                         UART comm
     MDM 25pin                                                        BUC RS232/422/485
                        DATA_RS485_IN_N           IO        13
                                                                         UART comm
                                                                     Main Status TX RS232
                          MAIN_TX_RS232           O         14
                                                                             (ICD)
                                                                    Main Command RX RS232
                         MAIN_RX_RS232               I      15
                                                                             (ICD)
                                                                      Sec Status TX RS232
                           SEC_TX_RS232           O         16
                                                                          (Reserved)
                                                                    Sec Command RX RS232
                          SEC_RX_RS232               I      17
                                                                          (Reserved)
                                                                        External GPIO 1
                            EXT_GPIO1             IO        18
                                                                          (Reserved)
                                                                        External GPIO 2
                            EXT_GPIO2             IO        19
                                                                          (Reserved)
                            ETH_A_RX+                I      20        Ethernet port A Rx+
                            ETH_A_RX -               I      21        Ethernet port A Rx -

 8
                                     Business sensitive


    Connector               Signal name          I/O     Pin No.       Description
                            ETH_B_RX+             I        22      Ethernet port B Rx+
                            ETH_B_RX -            I        23      Ethernet port B Rx -
                                                                   BUC RS232/422/485
                         DATA_RS485_OUT_P        IO        24
                                                                      UART comm
                                                                   BUC RS232/422/485
                         DATA_RS485_OUT_N        IO        25
                                                                      UART comm



      J2 WR28: Ka Tx WR28

      J3 SMA: L Tx in

      J4 SMA: L Tx out

      J5 SMA: L Rx out

      J6 SMA: LRx in

      J7 SMA: OPT




9
                                    Business sensitive


     2.1.6   ANTENNA PATTERNS




                      FIGURE 6: MICROSAT KA ANTENNA PATTERN




10
                                Business sensitive


     2.1.7     CONTROL APPLICATION TECHNICIAN GRAPHICAL INTERFACE (GUI)




                               FIGURE 7: SYSTEM GUI APPLICATION

         The system will be provided with a control application. The application is used to pre
         configure the system, when which afterwards it’ll operate as plug and play.




11
                                       Business sensitive


     2.1.8      OPERATION MODES



                            Manual mode controls the antenna in each direction
                            from ICD (RS232/IP).
                             AZ Step Resolution = 0.1 deg
             Manual          EL Step Resolution = 0.1 deg
                             Az = 0, El = 0 points to Home
                             Motor ctrl = Encoder loop PID



                            This Mode is based on AZ/EL IMU. The system closes
                            the pointing loop using angles from the static IMU on
             Euler          the Base of the unit.
             Angles         This mode usually initiated during power up and search
                            mode sequence for initial pointing position.



                            This Mode based on El IMU. The system close the Loop
                            with 3-Axis Gyros from rotating head.
                            During this mode the system perform the correction of the
             Gyro           pointing using the RSSI and the Gyro's installed on the
             Tracking       antenna.
                            Using the Multi feedback mechanism (RSSI and IMU) the
                            system can perform the excellent pointing to the base
                            station without GPS.



                            FIGURE 8: SYSTEM OPERATION MODES




12
                                    Business sensitive


     2.1.9        POINTING FLOW CHART



                                        Power UP


                                  Calibrate and move to
                                      Home position



                                  Go to last Base-Station
                                 Using Euler Angles Mode
                                         (AZ IMU)




                                    Receiver/Modem
Fine tune the pointing
                                       feedback




                                                                     Go to Gyro Tracking
             No                      Rx signal test pass     Yes
                                                                       mode (El IMU)




                                                                    Gyro Tracking with RX
                                                                     and IMU correction



                                                                                            Yes




                  No                                                 Rx signal test pass



                             FIGURE 9: SYSTEM POINTING FLOW CHART




13
                                        Business sensitive



Document Created: 2016-05-19 17:19:52
Document Modified: 2016-05-19 17:19:52

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC