                                                                       NewCom International, Inc.
                                                          Request for Special Temporary Authority
                                                                                        Exhibit B

                        EXHIBIT B – RADIATION HAZARD STUDY

                         Channel Master Model 62-12362-01 Antenna

1.0 Introduction

NewCom International, Inc. (“NewCom”) intends to deploy a transmit/receive 1.2m antenna at
its flagship teleport in Miami, Florida. This fixed satellite antenna has 43.3 dBi gain, and will be
equipped with a 4 Watt transceiver. Maximum output from the transceiver will be limited to 4
Watts and EIRP will not exceed 49.3 dBW.

2.0 Antenna Analysis Method

This report is developed in accordance with the prediction methods contained in OET Bulletin
No. 65, Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency
Electromagnetic Fields, Edition 97-01, pp 26-30. The maximum level of non-ionizing radiation
to which employees may be exposed is limited to a power density level of 5 milliwatts per square
centimeter (5 mW/cm2) averaged over any 6 minute period in a controlled environment and the
maximum level of non-ionizing radiation to which the general public is exposed is limited to a
power density level of 1 milliwatt per square centimeter (1 mW/cm2) averaged over any 30
minute period in an uncontrolled environment. These calculations demonstrate that the radiation
levels associated with NewCom’s short-term testing are within acceptable limits when compared
to the levels established for Maximum Permissible Exposure (“MPE”) defined in Bulletin 65,
Appendix A for Occupational/Controlled Limits and General Population/Uncontrolled Limits.

3.1 1.2m Antenna Specifications

The proposed antenna is a Channel Master model 62-12362-01 transmit/receive antenna
equipped with a 4 Watt transceiver. The parameters for this antenna are shown in the table
below.

Antenna Actual Diameter                               1.2 meters
Antenna Surface Area                                  1.13 sq. meters
Antenna Isotropic Gain                                43.3 dBi
Number of Identical Adjacent Antennas*                0
Nominal Antenna Efficiency (η)                        67 %
Nominal Frequency                                     14250 MHz
Nominal Wavelength (λ)                                0.0211 meters
Maximum Transmit Power / Carrier                      4 Watts
Number of Carriers                                    1
Total Transmit Power                                  4 Watts
W/G Loss from Transmitter to Feed                     0.1 dB
Total Feed Input Power                                3.9 Watts
Near Field Limit                                      R nf = D²/4λ = 17 meters
Far Field Limit                                       R ff = 0.6 D²/λ = 41 meters
Transition Region                                     R nf to R ff


                                           Page 1 of 11
A/75694508.1


                                                                             NewCom International, Inc.
                                                                Request for Special Temporary Authority
                                                                                              Exhibit B



Note that the worst-case radiation hazards exist along the beam axis. Under normal
circumstances, it is highly unlikely that the antenna axis will be aligned with any occupied area
since that would represent a blockage to the desired signals, thus rendering the link unuseable.

In the following sections, the power density in the above regions, as well as other critically
important areas will be calculated and evaluated. The calculations are done in the order
discussed in OET Bulletin 65.

3.2 Main Reflector Region

The power density at the reflector surface can be calculated from the expression:

  PD refl =     4P/A =      1.38 mW/cm²         (1)
  Where:        P = total power at feed, milliwatts
                A = Total area of reflector, sq. cm



In the normal range of transmit powers for this satellite antenna, the power densities at or around
the reflector surface are expected to exceed safe levels. Please note that precautionary measures
will be taken during the individual installations of the antenna to ensure that this area will be
inaccessible to the general public. Operators and technicians have received training specifying
this area as a high exposure area. Furthermore, procedures have been established that ensure all
transmitters are turned off before access to this area by maintenance personnel is possible.

3.3 On-Axis Near Field Region

The geometrical limits of the radiated power in the near field approximate a cylindrical volume
with a diameter equal to that of the antenna. In the near field, the power density is neither
uniform nor does its value vary uniformly with distance from the antenna. For the purpose of
considering radiation hazard it is assumed that the on-axis flux density is at its maximum value
throughout the length of this region. The length of this region, i.e., the distance from the antenna
to the end of the near field, is computed as Rnf above.

The power density within the on-axis near field region can be calculated from the expression:

  PD nf = (16 η P)/(π D²) =                  0.93 mW/cm² (2)
                                             from 0 to 17 meters
  Evaluation
  Uncontrolled Environment:                 Complies to FCC Limits
  Controlled Environment:                   Complies to FCC Limits



* Power Density Limit for Controlled and Uncontrolled Environment is met in the Near Field
Region.


                                                 Page 2 of 11
A/75694508.1


                                                                             NewCom International, Inc.
                                                                Request for Special Temporary Authority
                                                                                              Exhibit B

3.4 On-Axis Transition Field Region

The transition region is located between the near and far field regions. As stated in Bulletin 65,
the power density begins to vary inversely with distance in the transition region. The maximum
power density in the transition region will not exceed that calculated for the near field region,
and the transition region begins at that value. The maximum value for a given distance within
the transition region may be computed for the point of interest according to the following
methodology:


We use the equation below (3) to determine the safe on-axis distances required for the two
occupancy conditions:

   PD t =         (PD nf )(R nf )/R = dependent on R (3)
                  = 0.93 mW/cm² at R = 17 m
   where:         PD nf = near field power density
                  R nf = near field distance
                  R = distance to point of interest
   For:           17 < R < 41 meters


 Evaluation
 Uncontrolled Environment Safe Operating
 Distance,(meters), R safeu :                         17 **
 Controlled Environment Safe Operating
 Distance,(meters), R safec :                         17 **



** Power Density Limit for Controlled and Uncontrolled Environments is met in the Transition
Field Region

3.5 On-Axis Far-Field Region

The on-axis power density in the far field region (PD ff ) varies inversely with the square of the
distance as follows:

We use the equation below (4) to determine the safe on-axis distances required for the two
occupancy conditions:

 PD ff = PG/(4πR²) = dependent on R (4)
 where: P = total power at feed
         G = Numeric Antenna gain in the direction of interest relative
         to isotropic radiator
         R = distance to the point of interest
 For:    R > R ff = 41 meters
         PD ff = 0.394 mW/cm² at R ff




                                                 Page 3 of 11
A/75694508.1


                                                                                  NewCom International, Inc.
                                                                     Request for Special Temporary Authority
                                                                                                   Exhibit B

 Evaluation
 Uncontrolled Environment Safe Operating
 Distance,(meters), R safeu :                          41
 Controlled Environment Safe Operating
 Distance,(meters), R safec :                          41



3.6 Off-Axis Far-Field Region

In the far field region power is distributed in a pattern of maxima and minima (sidelobes) as a
function of the off-axis angle between the antenna center line and the point of interest. Off-axis
power density in the far field can be estimated using the antenna radiation patterns prescribed for
the antenna in use. Usually this will correspond to the antenna gain pattern envelope defined by
the FCC or the ITU, which takes the form of:

  G off = 32 - 25log(Θ) (5)
  for Θ from 1 to 48 degrees; -10 dBi from 48 to 180 degrees
  (Applicable for commonly used satellite transmit antennas)

Considering that satellite antenna beams are aimed skyward, power density in the far field will
usually not be a problem except at low look angles. In these cases, the off axis gain reduction
may be used to further reduce the power density levels.

For example: At one (1) degree off axis at the far-field limit, we can calculate the power density
as:

G off = 32 - 25log(1) = 32 - 0 dBi = 1585 numeric

  Evaluation
  PD 1 deg off-axis = PD ff x 1585/G = 0.029 mW/cm²



3.7 Off-Axis Power Density in the Near-Field and Transitional Region

According to Bulletin 65, off-axis calculations in the near field may be performed as follows:
assuming that the point of interest is at least one antenna diameter removed from the center of
the main beam, the power density at that point is at least a factor of 100 (20 dB) less than the
value calculated for the equivalent on-axis power density in the main beam. Therefore, for
regions at least 1.2 meters away from the center line of the dish, whether behind, below, or in
front of the antenna's main beam, the power density exposure is at least 20 dB below the main
beam level as follows:

  PD nf(off-axis) = PD nf /100 = 0.0093 mW/cm² at D off axis (6)



Evaluation of Safe Occupancy Area in Front of Antenna



                                                      Page 4 of 11
A/75694508.1


                                                                            NewCom International, Inc.
                                                               Request for Special Temporary Authority
                                                                                             Exhibit B

The safe distance (S) from a vertical axis passing through the dish center to a safe off axis
location in front of the antenna can be determined based on the dish diameter rule above (6).
Assuming a flat terrain in front of the antenna, the relationship is:

  S = (D/ sin α) + (2h - D - 2)/(2 tan α) (7)
  Where:        α = minimum elevation angle of antenna
                D = dish diameter in meters
                h = maximum height of object to be cleared, meters
For distances equal or greater than determined by equation (7), the radiation hazard will be below safe levels
for all but the most powerful stations (> 4 kilowatts RF at the feed).
  For D =                        1.2 meters
         h=                      1 meter
  Then:
         α                       S
         10                      3.5 meters
         15                      2.24 meters
         20                      1.86 meters
         25                      1.55 meters
         30                      1.36 meters
         35                      1.24 meters
         45                      1.1 meters



4.0 Expected Radiation Levels

               Region     Antenna               Near Field              Far Field             Transition
                        Surface Area                                                          (Midpoint)
                         (mW/cm2)                Dist. (m)              Dist. (m)
                                                (mW/cm2)               (mW/cm2)                Dist. (m)
Antenna                                                                                       (mW/cm2)
  1.2 m / 3.9 W                                       17                    41                     29
      BUC
                              1.13                  0.93                  0.394                  0.231




                                                Page 5 of 11
A/75694508.1


                                                                     NewCom International, Inc.
                                                        Request for Special Temporary Authority
                                                                                      Exhibit B

5.0 Conclusions

Based on the above analysis, it is concluded that harmful levels of radiation will not exist in
regions normally occupied by the public or the antenna’s operating personnel. It is still
recommended that all personnel be trained in RF safety when working around or maintaining this
type of antenna. Furthermore, it will be stressed that transmitters always be turned off during
maintenance in accordance with standard operating procedures.



                               Patriot TX-INT120KUG Antenna

1.0 Introduction

NewCom intends to deploy a transmit/receive 1.2m antenna at its flagship teleport in Miami,
Florida. This fixed satellite antenna has 43.4 dBi gain, and will be equipped with a 4 Watt
transceiver. Maximum output from the transceiver will be limited to 4 Watts and EIRP will not
exceed 49.4 dBW.

2.0 Antenna Analysis Method

This report is developed in accordance with the prediction methods contained in OET Bulletin
No. 65, Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency
Electromagnetic Fields, Edition 97-01, pp 26-30. The maximum level of non-ionizing radiation
to which employees may be exposed is limited to a power density level of 5 milliwatt per square
centimeter (5 mW/cm2) averaged over any 6 minute period in a controlled environment and the
maximum level of non-ionizing radiation to which the general public is exposed is limited to a
power density level of 1 milliwatt per square centimeter (1 mW/cm2) averaged over any 30
minute period in an uncontrolled environment. These calculations demonstrate that the radiation
levels associated with NewCom’s short-term testing are within acceptable limits when compared
to the levels established for Maximum Permissible Exposure (“MPE”) defined in Bulletin 65,
Appendix A for Occupational/Controlled Limits and General Population/Uncontrolled Limits.

3.1 1.2 m Antenna Specifications

The proposed antenna is a Patriot TX-INT120KUG transmit/receive antenna equipped with a 4
Watt transceiver. The parameters for this antenna are shown in the table below.

Antenna Actual Diameter                            1.2 meters
Antenna Surface Area                               1.13 sq. meters
Antenna Isotropic Gain                             43.4 dBi
Number of Identical Adjacent Antennas*             0
Nominal Antenna Efficiency (η)                     68.5 %
Nominal Frequency                                  14250 MHz
Nominal Wavelength (λ)                             0.0211 meters
Maximum Transmit Power / Carrier                   4 Watts
Number of Carriers                                 1


                                         Page 6 of 11
A/75694508.1


                                                                             NewCom International, Inc.
                                                                Request for Special Temporary Authority
                                                                                              Exhibit B

Total Transmit Power                                        4 Watts
W/G Loss from Transmitter to Feed                           0.1 dB
Total Feed Input Power                                      3.9 Watts
Near Field Limit                                            R nf = D²/4λ = 17 meters
Far Field Limit                                             R ff = 0.6 D²/λ = 41 meters
Transition Region                                           R nf to R ff



Note that the worst-case radiation hazards exist along the beam axis. Under normal
circumstances, it is highly unlikely that the antenna axis will be aligned with any occupied area
since that would represent a blockage to the desired signals, thus rendering the link unuseable.

In the following sections, the power density in the above regions, as well as other critically
important areas will be calculated and evaluated. The calculations are done in the order
discussed in OET Bulletin 65.

3.2 Main Reflector Region

The power density at the reflector surface can be calculated from the expression:

  PD refl =     4P/A =      1.38 mW/cm²         (1)
  Where:        P = total power at feed, milliwatts
                A = Total area of reflector, sq. cm



In the normal range of transmit powers for this satellite antenna, the power densities at or around
the reflector surface are expected to exceed safe levels. Please note that precautionary measures
will be taken during the individual installations of the antenna to ensure that this area will be
inaccessible to the general public. Operators and technicians have received training specifying
this area as a high exposure area. Furthermore, procedures have been established that ensure all
transmitters are turned off before access to this area by maintenance personnel is possible.

3.3 On-Axis Near Field Region

The geometrical limits of the radiated power in the near field approximate a cylindrical volume
with a diameter equal to that of the antenna. In the near field, the power density is neither
uniform nor does its value vary uniformly with distance from the antenna. For the purpose of
considering radiation hazard it is assumed that the on-axis flux density is at its maximum value
throughout the length of this region. The length of this region, i.e., the distance from the antenna
to the end of the near field, is computed as Rnf above.

The power density within the on-axis near field region can be calculated from the expression:

  PD nf = (16 η P)/(π D²) =                  0.945 mW/cm² (2)
                                             from 0 to 17 meters
  Evaluation



                                                 Page 7 of 11
A/75694508.1


                                                                            NewCom International, Inc.
                                                               Request for Special Temporary Authority
                                                                                             Exhibit B

  Uncontrolled Environment:               Complies to FCC Limits
  Controlled Environment:                 Complies to FCC Limits



* Power Density Limit for Controlled and Uncontrolled Environment is met in the Near Field
Region.

3.4 On-Axis Transition Field Region

The transition region is located between the near and far field regions. As stated in Bulletin 65,
the power density begins to vary inversely with distance in the transition region. The maximum
power density in the transition region will not exceed that calculated for the near field region,
and the transition region begins at that value. The maximum value for a given distance within
the transition region may be computed for the point of interest according to the following
methodology:


We use the equation below (3) to determine the safe on-axis distances required for the two
occupancy conditions:

   PD t =        (PD nf )(R nf )/R = dependent on R (3)
                 = 0.945 mW/cm² at R = 17 m
   where:        PD nf = near field power density
                 R nf = near field distance
                 R = distance to point of interest
   For:          17 < R < 41 meters


 Evaluation
 Uncontrolled Environment Safe Operating
 Distance,(meters), R safeu :                             17 m **
 Controlled Environment Safe Operating
 Distance,(meters), R safec :                             17 m **



** Power Density Limit for Controlled and Uncontrolled Environment is met in the Near Field
Region.

3.5 On-Axis Far-Field Region

The on-axis power density in the far field region (PD ff ) varies inversely with the square of the
distance as follows:

We use the equation below (4) to determine the safe on-axis distances required for the two
occupancy conditions:

 PD ff = PG/(4πR²) = dependent on R (4)
 where: P = total power at feed

                                                Page 8 of 11
A/75694508.1


                                                                                  NewCom International, Inc.
                                                                     Request for Special Temporary Authority
                                                                                                   Exhibit B

           G = Numeric Antenna gain in the direction of interest relative
           to isotropic radiator
           R = distance to the point of interest
 For:      R > R ff = 41 meters
           PD ff = 0.404 mW/cm² at R ff


 Evaluation
 Uncontrolled Environment Safe Operating
 Distance,(meters), R safeu :                          41
 Controlled Environment Safe Operating
 Distance,(meters), R safec :                          41



3.6 Off-Axis Far-Field Region

In the far field region power is distributed in a pattern of maxima and minima (sidelobes) as a
function of the off-axis angle between the antenna center line and the point of interest. Off-axis
power density in the far field can be estimated using the antenna radiation patterns prescribed for
the antenna in use. Usually this will correspond to the antenna gain pattern envelope defined by
the FCC or the ITU, which takes the form of:

  G off = 32 - 25log(Θ) (5)
  for Θ from 1 to 48 degrees; -10 dBi from 48 to 180 degrees
  (Applicable for commonly used satellite transmit antennas)

Considering that satellite antenna beams are aimed skyward, power density in the far field will
usually not be a problem except at low look angles. In these cases, the off axis gain reduction
may be used to further reduce the power density levels.

For example: At one (1) degree off axis at the far-field limit, we can calculate the power density
as:

G off = 32 - 25log(1) = 32 - 0 dBi = 1585 numeric

  Evaluation
  PD 1 deg off-axis = PD ff x 1585/G = 0.029 mW/cm²



3.7 Off-Axis Power Density in the Near-Field and Transitional Region

According to Bulletin 65, off-axis calculations in the near field may be performed as follows:
assuming that the point of interest is at least one antenna diameter removed from the center of
the main beam, the power density at that point is at least a factor of 100 (20 dB) less than the
value calculated for the equivalent on-axis power density in the main beam. Therefore, for
regions at least 1.2 meters away from the center line of the dish, whether behind, below, or in
front of the antenna's main beam, the power density exposure is at least 20 dB below the main
beam level as follows:

                                                      Page 9 of 11
A/75694508.1


                                                                                 NewCom International, Inc.
                                                                    Request for Special Temporary Authority
                                                                                                  Exhibit B

  PD nf(off-axis) = PD nf /100 = 0.00945 mW/cm² at D off axis (6)



Evaluation of Safe Occupancy Area in Front of Antenna

The safe distance (S) from a vertical axis passing through the dish center to a safe off axis
location in front of the antenna can be determined based on the dish diameter rule above (6).
Assuming a flat terrain in front of the antenna, the relationship is:

  S = (D/ sin α) + (2h - D - 2)/(2 tan α) (7)
  Where:        α = minimum elevation angle of antenna
                D = dish diameter in meters
                h = maximum height of object to be cleared, meters
For distances equal or greater than determined by equation (7), the radiation hazard will be below safe levels
for all but the most powerful stations (> 4 kilowatts RF at the feed).
  For D =                        1.2 meters
         h=                      1 meter
  Then:
         α                       S
         10                      3.5 meters
         15                      2.24 meters
         20                      1.86 meters
         25                      1.55 meters
         30                      1.36 meters
         35                      1.24 meters
         45                      1.1 meters



4.0 Expected Radiation Levels

               Region       Antenna                 Near Field             Far Field          Transition
                          Surface Area                                                        (Midpoint)
                           (mW/cm2)                  Dist. (m)             Dist. (m)
                                                    (mW/cm2)              (mW/cm2)             Dist. (m)
Antenna                                                                                       (mW/cm2)
  1.2 m / 3.9 W                                           17                  41                   29
      BUC
                                1.13                    0.945                0.404               0.554




                                                   Page 10 of 11
A/75694508.1


                                                                     NewCom International, Inc.
                                                        Request for Special Temporary Authority
                                                                                      Exhibit B

5.0 Conclusions

Based on the above analysis, it is concluded that harmful levels of radiation will not exist in
regions normally occupied by the public or the antenna’s operating personnel. It is still
recommended that all personnel be trained in RF safety when working around or maintaining this
type of antenna. Furthermore, it will be stressed that transmitters always be turned off during
maintenance in accordance with standard operating procedures.