                         ANALYSIS OF NON-IONIZING RADIATION
                         for GCI COMMUNICATIONS CORPORATION
                           Site: Unalakleet ES State: AK
                Latitude: 63 52 37.2 Longitude: 160 47 20.2            (NAD83)
                                     03-22-2013

     The Office of Science and Technology Bulletin, No. 65, October
     1985 and revised August 1997, specifies that the maximum level
     of non-ionizing radiation that a person may be exposed to over a
     six minute period is an average power density equal to 5 mW/cm**2
     (five milliwatts per centimeter squared) for a controlled
     environment. For an uncontrolled environment, the maximum level
     of non-ionizing radiation that a person may be exposed to over a
     thirty minute period is an average power density equal to 1 mW/cm**2
     (one milliwatt per centimeter squared). It is the purpose of this
     report to determine the maximum power flux densities of the earth
     station in the far zone, near zone, transition zone, at the main
     reflector surface, and between the antenna edge and the ground.


     Parameters which were used in the calculations:
     ===============================================

     Antenna Diameter,              (D) = 3.8000 m

     Antenna Surface Area          (Sa) =          pi(D**2)/4       = 11.3411 m**2

     Wavelength at 6.2000 GHz   (lambda) = 0.0483 m

     Transmit Power at Flange       (P) = 4.0000 Watts

     Antenna Gain at Earth Site    (GES) = 46.2000 dBi          =    41686.9383
                                                                        Power Ratio:
                                                                       AntiLog
     (GES/10)
     pi                                  =         3.1415927

     Antenna Aperture Efficiency    (n) = 0.6000




Exhibit 5                              Exhibit 5                                        1 of 5


Exhibit 5                              Exhibit 5                                 Exhibit 5




     1. FAR ZONE CALCULATIONS
     ========================

     Distance to the Far Zone     (Df) =           (n)(D**2)   = 179.3789 m
                                                   ---------
                                                    lambda


     Far Zone Power Density       (Rf) =         (GES)(P)      = 0.4124 W/m**2
                                               ------------
                                               4*pi*(Df**2)
                                                               = 0.0412 mW/cm**2




     2. NEAR ZONE CALCULATIONS
     =========================

     Power Flux Density is considered to be at a maximum value
     throughout the entire length of this Zone. The Zone is
     contained within a cylindrical volume which has the same diameter
     as the antenna. Beyond the Near Zone, the Power Flux Density
     will decrease with distance from the Antenna.

     Distance to the Near Zone    (Dn) =             D**2      = 74.7412 m
                                                   --------
                                                   4*lambda


     Near Zone Power Density      (Rn) =           16.0(n)P    = 0.8465 W/m**2
                                                   --------
                                                   pi(D**2)

                                                               = 0.0846 mW/cm**2




     3. TRANSITION ZONE CALCULATIONS
     ===============================

     The Power Density begins to decrease with distance in the
     Transition Zone. While the Power Density decreases inversely with
     distance in the Transition Zone, the Power Density decreases
     inversely with the square of the distance in the Far Zone.
     Since the maximum Power Density in the Transition Zone will not
     exceed the Near Zone values, it is not calculated.




Exhibit 5                              Exhibit 5                                    2 of 5


Exhibit 5                             Exhibit 5                             Exhibit 5




     4. MAIN REFLECTOR ZONE
     ======================

     Main Reflector Power Density       =         2(P)    = 0.7054 W/m**2
                                                  ----
                                                   Sa
                                                          = 0.0705 mW/cm**2




     5. ZONE BETWEEN THE MAIN REFLECTOR AND THE GROUND
     =================================================

     Applying uniform illumination of the Main Reflector Surface:

     Main to Ground Power Density       =          P      = 0.3527 W/m**2
                                                  ----
                                                   Sa
                                                          = 0.0353 mW/cm**2




Exhibit 5                             Exhibit 5                                3 of 5


Exhibit 5                                Exhibit 5                         Exhibit 5




                          CALCULATED SAFETY MARGINS SUMMARY
                                    AND EVALUATION

     ------------------------------------------------------------------------
     --
       Controlled Safety Margin = 5.0 - Calculated Zone Value (mW/cm**2)
     ------------------------------------------------------------------------
     --

                                         Safety
            Zones                        Margins      Conclusions
                                        (mW/cm**2)
     ----------------------------      ------------
     ----------------------------
     1. Far Zone                             4.9588   Complies with ANSI

     2.     Near Zone                        4.9154   Complies with ANSI

     3.     Transition Zone            Rf < Rt < Rn   Complies with ANSI

     4.     Main Reflector Surface           4.9295   Complies with ANSI

     5.     Main Reflector to Ground         4.9647   Complies with ANSI



     ------------------------------------------------------------------------
     --
       Uncontrolled Safety Margin = 1.0 - Calculated Zone Value (mW/cm**2)
     ------------------------------------------------------------------------
     --

                                         Safety
            Zones                        Margins      Conclusions
                                        (mW/cm**2)
     ----------------------------      ------------
     ----------------------------
     1. Far Zone                             0.9588   Complies with ANSI

     2.     Near Zone                        0.9154   Complies with ANSI

     3.     Transition Zone            Rf < Rt < Rn   Complies with ANSI

     4.     Main Reflector Surface           0.9295   Complies with ANSI

     5.     Main Reflector to Ground         0.9647   Complies with ANSI




     6. EVALUATION
     ==============

     A. Controlled Environment
     B. Uncontrolled Environment



Exhibit 5                                Exhibit 5                            4 of 5


Exhibit 5                               Exhibit 5   Exhibit 5




            All Zones comply with ANSI Standards.




Exhibit 5                               Exhibit 5      5 of 5