                               Engineering Statement
                     RADIOFREQUENCY EXPOSURE CALCULATIONS
                                                 prepared for
                                    WCVB Hearst Television Inc.

        WCVB Hearst Television Inc. (“WCVB”) is the licensee for transportable “Ku Band” satellite
uplink E880308. The following study was conducted to evaluate the replacement of the E880308
transmit / receive antenna, as proposed in the instant application, with respect to the potential for human
exposure to radiofrequency (“RF”) electromagnetic field. Specifically, the study determined whether
exposure to RF electromagnetic field would exceed FCC maximum permissible exposure limits to the
general public and to occupational workers at locations in the vicinity of the uplink antenna, based on
data provided by the applicant and representatives of the equipment manufacturers.



Human Exposure to Radiofrequency Electromagnetic Field
        The WCVB proposed operation was evaluated using the procedures outlined in FCC OET
Bulletin No. 65 (“OET 65"). OET 65 describes a means of determining whether a proposed facility
exceeds the RF exposure guidelines specified in §1.1310 of the Rules. Under present Commission
policy, a facility may be presumed to comply with the limits in §1.1310 if it satisfies the exposure criteria
set forth in OET 65.      Based upon that methodology, and as demonstrated in the following, the
transmitting system under study will comply with the cited adopted guidelines at publicly accessible
locations when procedures described herein are followed.



Public Exposure
        The mechanical design of the mounting equipment is optimized to orient the antenna toward
satellites that are located well above the horizon.       Prevention of public exposure to predicted RF
electromagnetic field in excess of the general population/uncontrolled limit1 depends on adherence to the
following operational guidelines by the WCVB technicians.


        As shown below, RF attributable to the WCVB uplink antenna at locations outside of the “main
beam” and 1.8 meters or more from the center of the main beam will not exceed the FCC general
population and uncontrolled RF exposure limits. According to representatives of WCVB, the center of
the uplink antenna is 4.3 meters above the ground and thus more than 1.8 meters above head level on
level terrain.



        1
            The general population/uncontrolled maximum permissible exposure (“MPE”) limit of 1 mW/cm² for


                                      Cavell, Mertz & Associates, Inc.


                                          Engineering Statement
                                                   (page 2 of 4)

        To assure that no publicly accessible area is within the “main beam” of the uplink antenna, sites
and satellites will be selected such that the elevation angle of the antenna will always exceed five degrees
and 1.8 meters above the horizon, nearby buildings, and places accessible by the public. In cases where
this isolation cannot be achieved, WCVB will utilize crowd control stanchions, cones, and RF exposure
warning signs to control access to areas that are known to exceed the FCC’s general population
uncontrolled MPE limit. These areas will be defined either by measurements made by qualified, on-site,
personnel or by the calculations described herein.


        Based on data provided by the applicant, the following parameters were used in the study:



             Antenna Manufacturer                            Vertex

             Antenna Model                                   1800 SNG

             Center Transmit Frequency                       14.250 MHz

             Wavelength at Center Frequency                  0.02104 meters

             Max Average Antenna Input Power                 75 Watts

             Antenna Diameter                                1.8 meters

             Antenna Gain                                    46.5 dBi

             Antenna Gain Ratio                              44,668

             Antenna Aperture Efficiency                     0.6182


        The area in the immediate vicinity of the antenna is known as the “near field region.”       In this
region (38.5 meters in the case at hand), the antenna directional characteristics of have not fully formed.
Therefore, antenna manufacturer “off-axis” discrimination specifications cannot be utilized for the
purpose of determining potential RF exposure. OET 65 provides a methodology (Equation 13) for
calculating an absolute “worst case” exposure figure within this region. Additionally, OET 65 specifies
that the “worst case” power density would be reduced by 20 dB at locations at least one antenna diameter
(1.8 meters) off-axis from the “main beam” of the antenna. In this instance, the predicted off-axis, near




14,250 MHz is specified in §1.1310 of the Rules.

                                        Cavell, Mertz & Associates, Inc.


                                            Engineering Statement
                                                 (page 3 of 4)

field is 0.0729 mW/cm², or 7.29 percent of the general population/uncontrolled limit. Off-axis predicted
fields reduce commensurately at greater distances from the antenna in the antenna transition region.


        In the “far field” region of the antenna (in this case, starting at a distance of 92.4 meters from the
antenna), the antenna directional characteristics have formed and the off-axis “far field” power density
can be readily calculated using “off-axis” antenna discrimination specifications. At locations greater than
five degrees off-axis from the “main beam,” the manufacturer of the proposed antenna specifies a
minimum side-lobe attenuation of 35 dB. Again using the methodology detailed in OET65, this “off-
axis” attenuation is predicted to result in a power density of 0.001 mW/cm², or 0.1 percent of the general
population/uncontrolled limit.


Controlled Access Area Exposure

        Access to the vicinity of the antenna will be limited and restricted to authorized, trained
personnel. Using data provided by the applicant, the potential for RF exposure to occupational workers
was evaluated. As described previously, the maximum predicted off-axis, “near field” power density is
0.0729 mW/cm², or 1.46% of the controlled limit. As the operator will generally be posted at locations at
ground level or within the truck itself, it is anticipated that actual exposure will be substantially less than
the above “worst case” prediction.



        With respect to worker safety, it is believed that based on the preceding analysis, excessive
exposure would not occur provided that adequate physical separation is established. As mentioned
previously, detailed operator policy will be employed protecting workers from excessive exposure when
work must be performed where high RF levels may be present. Such protective measures may include,
but will not be limited to, restriction of access to areas where levels in excess of the guidelines may be
expected, or the complete shutdown of facilities when work or inspections must be performed in areas
where the exposure guidelines would otherwise be exceeded. On-site RF exposure measurements may
also be undertaken to establish the bounds of safe working areas. The applicant will coordinate exposure
procedures with all pertinent facilities.

Conclusion

        As demonstrated herein, excessive levels of RF energy will not be caused at publicly accessible
areas by strictly following the policy detailed herein. Consequently, neither members of the general
public nor occupational staff will be exposed to RF levels in excess of the Commission’s guidelines.
Whenever necessary to assure compliance, access to the vicinity of the uplink antenna will be restricted

                                       Cavell, Mertz & Associates, Inc.


                                        Engineering Statement
                                               (page 4 of 4)

and controlled through the use of crowd control stanchions, cones, and conspicuous RFR warning signs
as part of an overall RF safety program. The above study presumes that the subject antenna is the sole
source of RF energy at the uplink site. In the case of multiple emitters, further analysis or measurement
is necessary to assure compliance.



Certification

        The undersigned hereby certifies that the foregoing statement was prepared by him or under his
direction, and that it is true and correct to the best of his knowledge and belief. Mr. Ryson is a senior
engineer in the firm of Cavell, Mertz & Associates, Inc.




                                                               BDaSR se
                                                               Daniel G. Ryson
                                                               November 5, 2010

Cavell, Mertz & Associates, Inc.