Attachment RadHaz

This document pretains to SES-MOD-20100921-01181 for Modification on a Satellite Earth Station filing.

IBFS_SESMOD2010092101181_840902

                                                               Attachment A
                                                               Page 1 of 5



                      Analysis of Non-Ionizing Radiation
                     for a 2.4 Meter Earth Station System


This report analyzes the non-ionizing radiation levels for a 2.4 meter
earth station system. The analysis and calculations performed in this report
are in compliance with the methods described in the FCC Office of Engineering
and Technology Bulletin, No. 65 first published in 1985 and revised in 1997
in Edition 97-01. The radiation safety limits used in the analysis are in
conformance   with the    FCC R&O 96-326.   Bulletin No. 65    and the    FCC
R&O specifies that there are two separate tiers of exposure limits that are
dependant on the situation in which the exposure takes place and/or the
status of the individuals who are subject to the exposure. The Maximum
Permissible   Exposure (MPE) limits for persons in a General Population/
Uncontrolled environment are shown in Table 1. The        General Population/
Uncontrolled MPE is a function of transmit frequency and is for an exposure
period of thirty minutes or less. The MPE limits for persons in an
Occupational/Controlled environment are shown in Table 2. The Occupational
MPE is a function of transmit frequency and is for an exposure period of six
minutes or less. The purpose of the analysis described in this report is to
determine the power flux density levels of the earth station in the
far-field, near-field, transition region, between the subreflector or feed
and main reflector surface, at the main reflector surface, and between
the antenna edge and the ground and to compare these levels to the
specified MPEs.




  Table 1. Limits for General Population/Uncontrolled Exposure(MPE)

  Frequency Range (MHz)              Power Density (mWatts/cm**2)

        30-300                                   0.2
       300-1500                          Frequency(MHz)*(0.8/1200)
      1500-100,000                               1.0


  Table 2. Limits for Occupational/Controlled Exposure(MPE)

  Frequency Range (MHz)              Power Density (mWatts/cm**2)

        30-300                                   1.0
       300-1500                          Frequency(MHz)*(4.0/1200)
      1500-100,000                               5.0




Table 3 contains the parameters that are used to calculate the various power
densities for the earth stations.


                                                                   Attachment A
                                                                   Page 2 of 5


Table 3.   Formulas and Parameters Used for Determining Power Flux Densities

     Parameter                Abbreviation       Value               Units
     Antenna Diameter             D              2.4                 meters
     Antenna Surface Area         Sa             II * D**2/4         meters**2
     Feed Flange Diameter         Df              19.0               cm
     Area of Feed Flange          Fa             II * Df**2/4        cm**2
     Frequency                    Frequency      14250               MHz
     Wavelength                   lambda      300/frequency(MHz)     meters
     Transmit Power               P                  4.00            Watts
     Antenna Gain                 Ges            49.2                dBi
     Pi                           II             3.1415927           n/a
     Antenna Efficiency           n              0.65                n/a



1.   Far Field Distance Calculation

The distance to the beginning of the far field can be determined from the
following equation:(1)

     Distance to the Far Field Region,(Rf) = 0.60 * D**2 / lambda                 (1)
                                           = 164.2 meters

The maximum main beam power density in the Far Field can be determined
from the following equation:(2)

     On-Axis Power Density in the Far Field,(Wf) = Ges * P / 4 * II * Rf**2 (2)
                                                 = 0.982 Watts/meters**2
                                                 = 0.098 mWatts/cm**2


2.   Near Field Calculation

Power flux density is considered to be at a maximum value throughout the
entire length of the defined Near Field region. The region is contained
within a cylindrical volume having the same diameter as the antenna.
Past the boundary of the Near Field region the power density from the
antenna decreases linearly with      respect to increasing     distance.

The distance to the end of the Near Field can be determined from the
following equation:(3)

     Extent of the Near Field,(Rn) = D**2 / (4 * lambda)                          (3)
                                   = 68.4 meters


The maximum power density in the Near Field can be determined from the
following equation:(4)

     Near Field Power Density,(Wn) = 16.0 * n * P / II * D**2                     (4)
                                   = 2.293 Watts/meters**2
                                   = 0.229 mWatts/cm**2


                                                                  Attachment A
                                                                  Page 3 of 5

3.   Transition Region Calculations

The Transition region is located between the Near and Far Field regions.
The power density begins to decrease linearly with increasing distance
in the Transition region. While the power density decreases inversely
with distance in the Transition region, the power density decreases
inversely with the square of the distance in the Far Field region. The
maximum power density in the Transition region will not exceed that
calculated for the Near Field region. The power density calculated in
Section 1 is the highest power density the antenna can produce in any of
the regions away from the antenna. The power density at a distance Rt
can be determined from the following equation:(5)

     Transition region Power Density,(Tt) = Wn * Rn / Rt                         (5)
                                          = 0.229 mWatts/cm**2


4.   Region between the Feed Assembly and the Antenna Reflector

Transmissions from the feed assembly are directed toward the antenna
reflector surface, and are confined within a conical shape defined by the
type of feed assembly. The most common feed assemblies are waveguide
flanges, horns or subreflectors. The energy between the feed assembly and
reflector surface can be calculated by determining the power density at
the feed assembly surface. This can be determined from the following
equation:(6)

     Power Density at the Feed Flange,(Wf) = 4 * P / Fa                          (6)
                                       = 56.432 mWatts/cm**2


5.   Main Reflector Region

The power density in the main reflector is determined in the same manner
as the power density at the feed assembly. The area is now the area of
the reflector aperture   and can be determined from      the   following
equation:(7)

     Power Density at the Reflector Surface,(Ws) = 4 * P / Sa                    (7)
                                                 = 3.537 Watts/meters**2
                                                 = 0.354 mWatts/cm**2


6.   Region between the Reflector and the Ground

Assuming uniform illumination of the reflector surface, the power density
between the antenna and the ground can be determined from the following
equation:(8)

Power Density between the Reflector and the Ground,(Wg) = P / Sa          (8)
                                                    = 0.884 Watts/meters**2
                                                    = 0.088 mWatts/cm**2


                                                                   Attachment A
                                                                   Page 4 of 5


Table 4. Summary of Expected Radiation levels for Uncontrolled Environment

                               Calculated Maximum Radiation
                                    Power Density Level
   Region                             (mWatts/cm**2)        Hazard Assessment


1. Far Field (Rf)   = 164.2 meters         0.098               Satisfies FCC MPE

2. Near Field (Rn) = 68.4 meters           0.229               Satisfies FCC MPE

3. Transition Region
   Rn < Rt < Rf, (Rt)                      0.229               Satisfies FCC MPE

4. Between Feed Assembly                   56.432              Potential Hazard
   and Antenna Reflector

5. Main Reflector                          0.354               Satisfies FCC MPE

6. Between Reflector                       0.088               Satisfies FCC MPE
   and Ground




Table 5. Summary of Expected Radiation levels for Controlled Environment

                               Calculated Maximum Radiation
                                    Power Density Level
   Region                             (mWatts/cm**2)        Hazard Assessment


1. Far Field (Rf)   = 164.2 meters         0.098               Satisfies FCC MPE

2. Near Field (Rn) = 68.4 meters           0.229               Satisfies FCC MPE

3. Transition Region
   Rn < Rt < Rf, (Rt)                      0.229               Satisfies FCC MPE

4. Between Feed Assembly                   56.432              Potential Hazard
   and Antenna Reflector

5. Main Reflector                          0.354               Satisfies FCC MPE

6. Between Reflector                       0.088               Satisfies FCC MPE
   and Ground




It is the     applicant's responsibility     to     ensure that the public and
operational   personnel are not exposed      to     harmful levels of radiation.


                                                            Attachment A
                                                            Page 5 of 5




7.     Conclusions




Based on the above analysis it is concluded that harmful levels of
radiation will not exist in regions normally occupied by the public or
the earth station's operating personnel. The transmitter will be turned
off during antenna maintenance so that the FCC MPE of 5.0 mW/cm**2 will
be complied with for those regions with close proximity to the reflector
that exceed acceptable levels.


     Study Prepared By:




     Timothy O. Crutcher
     Frequency Planner
     COMSEARCH
     19700 Janelia Farm Boulevard
     Ashburn, VA 20147


     Dated: September 21, 2010