Attachment rad haz -wmp005.pdf

This document pretains to SES-MFS-20110412-00429 for Modification w/ Foreign Satellite (earth station) on a Satellite Earth Station filing.

IBFS_SESMFS2011041200429_880647

                                                               Radiation Hazard Analysis



                                                                          13 Meter WMP-005
                                                                        Bristow, Virginia 20136

                     Introduction
                     A radiation hazard anaylsis is presented for a 13 meter Ku band aperture antenna to be installed in BristowVirginia at
                     the SES WORLD SKIES Washington Mediaport. This Radiation Analysis calculates the non-ionizing radiation levels
                     expected to be emitted from the earth station on a worse cases basis and is performed in accordance with the Federal
                     Communications Commissions Office of Engineering and Technology (OET) Bulletin, No. 65.



                     Requirements
                     OET 65 outlines the maximum permissible exposure limits in two cases for operation in this frequency range.

                         1. The first case is the maximum level that a person may be exposed to in the general population. The exposure
                              limit is defined as a non-ionizing power level equal to 1 milliwatt per centimeter squared averaged over a thirty
                              minute period.
                         2. The second case is a controlled environment where the maximum permissible exposure limit must not exceed 5
                              milliwatts per centimeter squared averaged over any six minute period.

                     Summary
                     The results indicate that no significant hazard will be presented to the general population and will be fully mitigated in
                     the controlled area by the use of procedures that require the removal of transmit power before accessing the area
                     around the main reflector.


                     Analysis
                     This analysis was performed on seven zones with the results shown in Radiation Hazard Zones. The Table labeled
                     Input Values provides the - input data required to perform the analysis. The table labeled OET 65 Calculated Values
                     provides the intermediate calculation used to perform the assessment in accordance with OET 65. The Analysis is
                     performed for each a the each of seven radiation zones as shown in figure 1 – Analysis Zones. These zones are:


                         1. Point between the feed and the sub-reflector
                         2. The power at the surface of the antenna
                         3. The power level between the main reflector and ground
                         4. The near-field or Fresnel region in which the maxima can be reached before the field starts to diminish with
                            distance
                         5. The Transition region where power begins to decrease inversely with distance from the antenna
                         6. The Far Field or Fraunhofer region where power decreases inversely with the square of the distance. This is the
                            point at which the antenna beam is fully collimated
                         7. The off axis level in the near field. This is defined as the area outside of the main beam removed and at least one
                            antenna diameter removed from the main beam




Generated 4/7/2011                                                              1 of 2                                               rad haz auto report-wmp005.xls


                                                         Radiation Hazard Analysis

                                       Operator:              SES WORLD SKIES
                            Location Designation:             Washington Mediaport            FCC Callsign: E020071
                                         County:              Prince William                       SES ID: WMP-005
                                           Town:              Bristow                                 STA:
                                       State/Zip:             Virginia       20136
                          Input Values                             Value         Unit                           Band          Frequency
                              D = Aperture Diameter                13.00           Meters                        L            1000-2000
                           d = Subreflector Diameter                 0.7           Meters                        S            2000-4000
                                  G = Antenna Gain                  63.9               dBi                       C            4000-8000
                                   FCC Designation                   Ku            Band                          X           8000-12500
                                      F = Frequency               14.000           GHz                           Ku          12500-18000
                        P = Transmitter Power Watts:               2458            Watts                         K           18000-25500
                  R ua = closest point to uncontrolled area          20           meters                         Ka          26500-40000
                  Elevation angle at closest point R ua              18           Degrees                        O           40000-50000
                                        Height (AGL)               6.18           meters                         V           50000-75000

                  OET 65 Calculated Values                      Formula            Value          Unit
                                                                    c
                                       λ= Wavelength                              0.0214     meters
                                                                    F
                                                                    (G/10)
                                   G = Antenna Gain              10            2454708.916 (W) linear
                                                                 Gλ2/4π
                          η = Apperture Efficiency                                     67%   percentage
                                                                  πD2/4
                               A = Area of reflector               πR2            132.732    meters 2
                            a = area of subreflector                πr2          3848.451    cm 2
                                                                    D2           1972.982    meters
                          R nf = Near-Field Region
                                                                    4λ              610      Meters AGL
                                                                   >Rnf          1972.982    >meters
                            R t = Transition Region
                                                                   <Rff          4735.157    <meters
                             R ff = Far Field Region              0.6D2          4735.157    meters
                                                                     λ             1463      Meters AGL

                                                                                                                   Exposure Limits
              Radiation Analysis Zone                           Formula            Level         Value     General Public   Occupational
                                                                                                            <1mW/cm2     <5mW/cm2
                                                                    4P                                     >FCC MPE See >FCC MPE See
         1                       Power Subreflector                              2554.794       mW/cm2
                                                                     a                                        Note 1       Note 2
                                                                    4P                                     >FCC MPE See >FCC MPE See
         2                          Antenna Surface                                7.407        mW/cm2
                                                                     A                                        Note 1       Note 2
                                                                     P                                     >FCC MPE See
         3                  Main Reflector Ground                                  1.852        mW/cm2                   <FCC MPE
                                                                     A                                        Note 1
                                                                   4η P                                    >FCC MPE See
         4        S nf =Near-Field Power Density                                   4.999        mW/cm2                   <FCC MPE
                                                                     A                                        Note 1
                                                                                                           >FCC MPE See
         5    S t = Max Transition Power Density                   < Snf           4.999        mW/cm2                   <FCC MPE
                                                                                                              Note 1
                                                                    PG                                     >FCC MPE See
         6     S ff = Max Far field Power Density                                  2.141        mW/cm2                        <FCC MPE
                                                                  4πRff2                                      Note 3
         7       Off Access Level Near Field                    Snf - 20 dB       0.04999       mW/cm2       <FCC MPE         <FCC MPE

       Notes
         1. The antenna is installed in a controlled location access is restricted to authorized personnel only. The antenna is
            marked with RF Radiation Hazard signage.
         2. Inside the controlled area, MPE levels exceed the MPE exposure for occupational levels. The levels will be
            reduced to safe MPE by removing power to the transmitters when work is performed on or around the antenna.
            This area can only be accessed by qualified personnel.
          3. The field develops 6.18 meters above ground level at the minimum elevation angle which is not accessable to
             the general public.