Attachment EXHIBIT E

This document pretains to SES-MFS-20100108-00025 for Modification w/ Foreign Satellite (earth station) on a Satellite Earth Station filing.

IBFS_SESMFS2010010800025_793537

                                                                             NewCom International
                                              Application to Add Express AM44 to Call Sign E040267
                                                                                           Exhibit E

  Radiation Hazard Report


      Analysis of Non-Ionizing Radiation for a 7.3-Meter Earth
                          Station System
This report analyzes the non-ionizing radiation levels for a 7.3-meter earth station system. The
analysis and calculations performed in this report comply with the methods described in the FCC
Office of Engineering and Technology Bulletin, No. 65 first published in 1985 and revised in 1997
in Edition 97-01. The radiation safety limits used in the analysis are in conformance with the FCC
R&O 96-326. Bulletin No. 65 and the FCC R&O specifies that there are two separate tiers of
exposure limits that are dependant on the situation in which the exposure takes place and/or the
status of the individuals who are subject to the exposure. The Maximum Permissible Exposure
(MPE) limits for persons in a General Population/Uncontrolled environment are shown in Table 1.
The General Population/Uncontrolled MPE is a function of transmit frequency and is for an
exposure period of thirty minutes or less. The MPE limits for persons in an
Occupational/Controlled environment are shown in Table 2. The Occupational MPE is a function of
transmit frequency and is for an exposure period of six minutes or less. The purpose of the
analysis described in this report is to determine the power flux density levels of the earth station in
the far-field, near-field, transition region, between the subreflector or feed and main reflector
surface, at the main reflector surface, and between the antenna edge and the ground and to
compare these levels to the specified MPEs.

               Table 1. Limits for General Population/Uncontrolled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              0.2
                         300-1500                  Frequency (MHz)*(0.8/1200)
                       1500-100,000                           1.0

                    Table 2. Limits for Occupational/Controlled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              1.0
                         300-1500                  Frequency (MHz)*(4.0/1200)
                       1500-100,000                           5.0

          Table 3. Formulas and Parameters Used for Determining Power Flux Densities
     Parameter                    Symbol              Formula               Value         Units
     Antenna Diameter                D                  Input                 7.3         m
     Antenna Surface Area          Asurface            π D2 / 4             41.85         m2
     Subreflector Diameter          Dsr                 Input               106.7         cm
     Area of Subreflector           Asr               π Dsr 2/4            8941.67        cm2
     Frequency                       F                  Input                6175         MHz
     Wavelength                      λ                 300 / F            0.048583        m
     Transmit Power                  P                  Input               157.00        W
     Antenna Gain (dBi)             Ges                 Input                51.7         dBi

                                        Page 1 of 5


                                                                               NewCom International
                                                Application to Add Express AM44 to Call Sign E040267
                                                                                             Exhibit E

 Radiation Hazard Report
      Antenna Gain (factor)             G                  10Ges/10             147910.8     n/a
      Pi                                π                 Constant             3.1415927     n/a
      Antenna Efficiency                η                 Gλ2/(π2D2)              0.66       n/a


1.      Far Field Distance Calculation

The distance to the beginning of the far field can be determined from the following equation:

     Distance to the Far Field Region                              Rff = 0.60 D2 / λ               (1)
                                                                       = 658.1 m

The maximum main beam power density in the far field can be determined from the following
equation:

     On-Axis Power Density in the Far Field                        Sff = G P / (4 π Rff 2)         (2)
                                                                       = 4.266 W/m2
                                                                       = 0.427 mW/cm2

2.      Near Field Calculation

Power flux density is considered to be at a maximum value throughout the entire length of the
defined Near Field region. The region is contained within a cylindrical volume having the same
diameter as the antenna. Past the boundary of the Near Field region, the power density from the
antenna decreases linearly with respect to increasing distance.

The distance to the end of the Near Field can be determined from the following equation:

     Extent of the Near Field                                      Rnf = D2 / (4 λ)                (3)
                                                                       = 274.2 m

The maximum power density in the Near Field can be determined from the following equation:

     Near Field Power Density                                      Snf = 16.0 η P / (π D2)         (4)
                                                                       = 9.960 W/m2
                                                                       = 0.996 mW/cm2

3.      Transition Region Calculation

The Transition region is located between the Near and Far Field regions. The power density
begins to decrease linearly with increasing distance in the Transition region. While the power
density decreases inversely with distance in the Transition region, the power density decreases
inversely with the square of the distance in the Far Field region. The maximum power density in
the Transition region will not exceed that calculated for the Near Field region. The power density
calculated in Section 1 is the highest power density the antenna can produce in any of the regions

                                            Page 2 of 5


                                                                            NewCom International
                                             Application to Add Express AM44 to Call Sign E040267
                                                                                          Exhibit E

 Radiation Hazard Report
away from the antenna. The power density at a distance Rt can be determined from the following
equation:

     Transition Region Power Density                        St = Snf Rnf / Rt                 (5)
                                                               = 0.996 mW/cm2


4.      Region between the Main Reflector and the Subreflector

Transmissions from the feed assembly are directed       toward the subreflector surface, and are
reflected back toward the main reflector. The most      common feed assemblies are waveguide
flanges, horns or subreflectors. The energy between     the subreflector and the reflector surfaces
can be calculated by determining the power density      at the subreflector surface. This can be
determined from the following equation:

     Power Density at the Subreflector                      Ssr = 4000 P / Asr                (6)
                                                                = 70.233 mW/cm2

5.      Main Reflector Region

The power density in the main reflector is determined in the same manner as the power density at
the subreflector. The area is now the area of the main reflector aperture and can be determined
from the following equation:

     Power Density at the Main Reflector Surface        Ssurface = 4 P / Asurface             (7)
                                                                 = 15.005 W/m2
                                                                 = 1.500 mW/cm2


6.      Region between the Main Reflector and the Ground

Assuming uniform illumination of the reflector surface, the power density between the antenna and
the ground can be determined from the following equation:

     Power Density between Reflector and Ground             Sg = P / Asurface                 (8)
                                                               = 3.751 W/m2
                                                               = 0.375 mW/cm2




                                         Page 3 of 5


                                                                          NewCom International
                                           Application to Add Express AM44 to Call Sign E040267
                                                                                        Exhibit E

 Radiation Hazard Report


7.     Summary of Calculations

            Table 4. Summary of Expected Radiation levels for Uncontrolled Environment
                                             Calculated Maximum
                                         Radiation Power Density Level
Region                                               (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 658.1 m)                     Sff        0.427            Satisfies FCC MPE
2. Near Field (Rnf = 274.2 m)                    Snf        0.996            Satisfies FCC MPE
3. Transition Region (Rnf < Rt < Rff)            St         0.996            Satisfies FCC MPE
4. Between Main Reflector and                    Ssr       70.233              Potential Hazard
    Subreflector
5. Main Reflector                                Ssurface   1.500              Potential Hazard
6. Between Main Reflector and Ground             Sg         0.375            Satisfies FCC MPE

             Table 5. Summary of Expected Radiation levels for Controlled Environment
                                            Calculated Maximum
                                           Radiation Power Density
Region                                         Level (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 658.1 m)                    Sff         0.427            Satisfies FCC MPE
2. Near Field (Rnf = 274.2 m)                   Snf         0.996            Satisfies FCC MPE
3. Transition Region (Rnf < Rt < Rff)           St          0.996            Satisfies FCC MPE
4. Between Main Reflector and                   Ssr       70.233              Potential Hazard
    Subreflector
5. Main Reflector                               Ssurface    1.500            Satisfies FCC MPE
6. Between Main Reflector and Ground            Sg          0.375            Satisfies FCC MPE

It is the applicant's responsibility to ensure that the public and operational personnel are not
exposed to harmful levels of radiation.


8.     Conclusions

Based on the above analysis it is concluded that the FCC MPE guidelines have been exceeded (or
met) in the regions of Table 4 and 5. The applicant proposes to comply with the MPE limits by one
or more of the following methods.

The earth station will be located in a Gated and Fenced facility with secured access in and around
the proposed antenna. Since the proposed earth station will not transmit at an antenna elevation of
less than 13.7 degrees, and since one diameter removed from the center of main beam the levels
are down at least 20 dB, or by a factor of 100, public safety will be ensured for the near and far
field regions.




                                       Page 4 of 5


                                                                           NewCom International
                                            Application to Add Express AM44 to Call Sign E040267
                                                                                         Exhibit E

 Radiation Hazard Report
Finally, occupational exposure will be limited, and the transmitter will be turned off during periods
of maintenance, so that the MPE standard of 5.0 mw/cm**2 will be complied with for those regions
in close proximity to the main reflector, and subreflector, which could be occupied by operating
personnel.