Attachment Exhibit A

This document pretains to SES-LIC-20190925-01197 for License on a Satellite Earth Station filing.

IBFS_SESLIC2019092501197_1900945

                                                                                                Exhibit A

Radiation Hazard Report
Analysis of Non-Ionizing Radiation for 1.2 m Earth Stations
This analysis provides the calculated non-ionizing radiation levels for a 1.2-meter earth station systems.

The methods and calculations performed in this analysis are based on the FCC Office of Engineering
and Technology Bulletin, No.65, October 1985 as revised in 1997 in Edition 97-01. The radiation safety
limits used in the analysis are in conformance with the FCC R&O 96-326 (Summarized in Annex 1).
There are separate exposure limits applicable to the General Population/Uncontrolled Environment and
the Occupational/Controlled Environment. The Maximum Permissible Exposure (MPE) limits for
persons in a General Population/Uncontrolled environment for the frequency band of this antenna, is 1
mW/cm2 for a 30 minute or lower time period as shown in Annex 1 (a). The MPE limit for persons in an
Occupational/Controlled environment for the frequency band of this antenna is 5 mW/cm2 for a 6
minute time or lower period as shown in Annex 1 (b). The purpose of this analysis described is to
determine the power flux density levels of the earth station at the main reflector surface, the near-field,
transition region, far-field, between the sub-reflector or feed and, at the main reflector surface, and
between the antenna edge and the ground and to compare these levels to the specified MPEs.



The parameters of the antennas that are the subject of this analysis are shown in Table 1.
Intermediate calculated values and constants are provided in Table 2.

 Table 1. Input Parameters Used for Determining Power Flux Densities
                 Parameter                     Symbol      Formula              Value           Units
Antenna Diameter                                 D          Input                1.2              m
Frequency                                         F         Input               14300           MHz
Transmit Power                                    P         Input                 8              W
Antenna Gain (dBi)                               Ges        Input                43.3            dBi

 Table 2. Calculated Values and Constants
                 Parameter                         Symbol       Formula          Value          Units
                                                                     2
Antenna Surface Area                                Asurface      πD /4           1.13          m^2
Wavelength                                              λ         300/F        0.020979          m
Antenna Gain (factor)                                   G        10Ges/10      21379.62          n/a
Pi                                                      π       Constant      3.1415927          n/a
Antenna Efficiency                                      η      Gλ2 /( π2D2)       0.66           n/a




                                                    1


1. Antenna Main Reflector Surface
The power density in the main reflector is determined from the Power level and the area of the main
reflector aperture. This is determined from the following equation:

              Power Density at the Main Reflector Surface:

                                         Ssurface = 4P/Asurface                         (1)
                                                                               2
                                                             =    28.294   W/m
                                                             =     2.829   mW/cm2

2. Near Field Calculation
Power Flux density is considered to be at a maximum value throughout the entire length of the defined
Near Field region. The region is contained within a cylindrical volume having the same diameter as the
antenna. Past the boundary of the Near Field region, the power density from the antenna decreases
linearly with respect to increasing distance. The distance to the end of the Near Field is determined
from the following equation:

                                   Extent of the Near Field:

                                               Rnf = D2 / (4λ)                          (2)
                                                             =    17.16    m

The maximum power density in the Near Field is determined from the following equation:

                                        Near Field Density:

                                     Snf = 16.0 η P / (π D2)                            (3)
                                                                                   2
                                                          =       1.873    mW/cm

3. Transition Region Calculation
The Transition Region is located between the Near and Far Field regions. The power density begins to
decrease linearly with increasing distance in the Transition region. While the power density decreases
inversely with distance in the Transition region, the power density decreases inversely with the square
of the distance in the Far Field region. The power density calculated in Section 1 is the highest power
density the antenna can produce in any of the regions away from the antenna. The power density at a
distance Rt is determined from the following equation:

                          Transition Region Power Density:

                                              St = Snf Rnf / Rt                         (4)
                                                                                   2
                                                             =    1.873    mW/cm




                                                    2


4. Far Field Distance Calculation
The distance to the Far Field Region is calculated using the following equation:

                               Distance to Far Field Region:

                                               Rff = 0.6 D2 / λ                            (5)
                                                              =   41.184   m

The maximum main beam power density in the far field is determined from the following equation:

                    On-axis Power Density in the Far Field:

                                         Sff = G P / (4 π Rff2)                            (6)
                                                                                   2
                                                             =    0.802    mW/cm

5. Region between the Main Reflector and the Ground
Assuming uniform illumination of the reflector surface, the power density between the antenna and the
ground is determined from the following equation:

             Power Density between Reflector and Ground:

                                              Sg = P / Asurface                            (7)
                                                                                       2
                                                             =    0.707        mW/cm




                                                     3


7. Summary of Calculations

 Table 3. Summary of Expected Radiation levels for Uncontrolled Environment
                                                                              Calculated
                                                                              Maximum
                                                                              Radiation
                                                                                              Hazard
                           Region                                Symbol         Power
                                                                                            Assessment
                                                                               Density
                                                                                Level
                                                                              (mW/cm2)
                                                                                              Potential
1. Main Reflector                                                 Ssurface       2.829
                                                                                               Hazard
                                                                                              Potential
2. Near Field                         (Rnf =     17.16 m)           Snf          1.873
                                                                                               Hazard
                                                                                              Potential
3. Transition Region (Rnf <Rt< Rff)                                 St           1.873
                                                                                               Hazard
                                                                                            Satisfies FCC
4. Far Field                          (Rff =     41.18 m)           Sff          0.802
                                                                                                 MPE
                                                                                            Satisfies FCC
5. Between Main Reflector and Ground                                Sg           0.707
                                                                                                 MPE

Table 4. Summary of Expected Radiation levels for Controlled Environment
                                                                              Calculated
                                                                              Maximum
                                                                              Radiation
                                                                                              Hazard
                           Region                                Symbol         Power
                                                                                            Assessment
                                                                               Density
                                                                                Level
                                                                                      2
                                                                              (mW/cm )
                                                                                            Satisfies FCC
1. Main Reflector                                                 Ssurface       2.829
                                                                                                 MPE
                                                                                            Satisfies FCC
2. Near Field                         (Rnf =     17.16 m)           Snf          1.873
                                                                                                 MPE
                                                                                            Satisfies FCC
3. Transition Region (Rnf <Rt< Rff)                                 St           1.873
                                                                                                 MPE
                                                                                            Satisfies FCC
4. Far Field                          (Rff =     41.18 m)           Sff          0.802
                                                                                                 MPE
                                                                                            Satisfies FCC
5. Between Main Reflector and Ground                                Sg           0.707
                                                                                                 MPE

It is the applicant’s responsibility to ensure that the public and operational personnel are not exposed to
harmful levels of radiation.




                                                     4


8. Conclusion
Based upon the above analysis, it is concluded that harmful levels of radiation may exist in those
regions noted for the Uncontrolled (Table 3) Environment and the Controlled Environment (Table 4).


The antennas will be in a secured facility and will be marked with the standard radiation hazard
warnings, as well as the area in the vicinity of the terminals to inform those in the general population,
who might be working or otherwise present in or near the direct path of the main beam.

The applicant will ensure that the main beam of the terminal antenna will be pointed at least one
diameter away from any building, or other obstacles in those area that exceed the MPE levels. Since
one diameter removed from the center of the main beam the levels are down by at least 20 dB, or by a
factor of 100, these potential hazards do not exist for either the public, or for earth station personnel.


Finally, the personnel operating the terminal antenna will not have access to areas that exceed the
MPE levels, while the antenna is in operation. The transmitter will be turned off during those periods of
maintenance, so that the MPE standard of 5.0 mW/cm2 will be complied with for those regions in close
proximity to the main reflector, which could be occupied by operating personnel.


 “The licensee shall take all necessary measures to ensure that the antennas do not create potential
exposure of humans to radiofrequency radiation in excess of the FCC exposure limits defined in 47
CFR 1.1307(b) and 1.1310 wherever such exposures might occur. Measures must be taken to ensure
compliance with limits for both occupational/controlled exposure and for general
population/uncontrolled exposure, as defined in these rule sections. Compliance can be accomplished
in most cases by appropriate restrictions such as fencing. Requirements for restrictions can be
determined by predictions based on calculations, modeling or by field measurements. The FCC's OET
Bulletin 65 (available on-line at www.fcc.gov/oet/rfsafety) provides information on predicting exposure
levels and on methods for ensuring compliance, including the use of warning and alerting signs and
protective equipment for workers.”




                                                     5


                                   ANNEX 1
                                  (MPE Levels)

a) Limits for General Population/Uncontrolled Exposure (MPE)
         Frequency Range (MHz)                       Power Density (mW/cm2)
                30-300                                        0.2
               300-1500                              Frequency(MHz)*(4.0/1200)
              1500-100,000                                      1

b) Limits for Occupational/Controlled Exposure (MPE)
          Frequency Range (MHz)                     Power Density (mW/cm2)
                   30-300                                     1
                  300-1500                         Frequency(MHz)*(4.0/1200)
              1500-100,000                                      5




                                                 6


Radiation Hazard Report
Analysis of Non-Ionizing Radiation for 1.2 m Earth Stations
This analysis provides the calculated non-ionizing radiation levels for a 1.2-meter earth station systems.

The methods and calculations performed in this analysis are based on the FCC Office of Engineering
and Technology Bulletin, No.65, October 1985 as revised in 1997 in Edition 97-01. The radiation safety
limits used in the analysis are in conformance with the FCC R&O 96-326 (Summarized in Annex 1).
There are separate exposure limits applicable to the General Population/Uncontrolled Environment and
the Occupational/Controlled Environment. The Maximum Permissible Exposure (MPE) limits for
persons in a General Population/Uncontrolled environment for the frequency band of this antenna, is 1
mW/cm2 for a 30 minute or lower time period as shown in Annex 1 (a). The MPE limit for persons in an
Occupational/Controlled environment for the frequency band of this antenna is 5 mW/cm2 for a 6
minute time or lower period as shown in Annex 1 (b). The purpose of this analysis described is to
determine the power flux density levels of the earth station at the main reflector surface, the near-field,
transition region, far-field, between the sub-reflector or feed and, at the main reflector surface, and
between the antenna edge and the ground and to compare these levels to the specified MPEs.



The parameters of the antennas that are the subject of this analysis are shown in Table 1.
Intermediate calculated values and constants are provided in Table 2.

 Table 1. Input Parameters Used for Determining Power Flux Densities
                 Parameter                     Symbol      Formula              Value           Units
Antenna Diameter                                 D          Input                1.2              m
Frequency                                         F         Input               14125           MHz
Transmit Power                                    P         Input                 8              W
Antenna Gain (dBi)                               Ges        Input                43.3            dBi

 Table 2. Calculated Values and Constants
                 Parameter                         Symbol       Formula          Value          Units
                                                                     2
Antenna Surface Area                                Asurface      πD /4           1.13          m^2
Wavelength                                              λ         300/F        0.021239          m
Antenna Gain (factor)                                   G        10Ges/10      21379.62          n/a
Pi                                                      π       Constant      3.1415927          n/a
Antenna Efficiency                                      η      Gλ2 /( π2D2)       0.68           n/a




                                                    1


1. Antenna Main Reflector Surface
The power density in the main reflector is determined from the Power level and the area of the main
reflector aperture. This is determined from the following equation:

              Power Density at the Main Reflector Surface:

                                         Ssurface = 4P/Asurface                         (1)
                                                                               2
                                                             =    28.294   W/m
                                                             =     2.829   mW/cm2

2. Near Field Calculation
Power Flux density is considered to be at a maximum value throughout the entire length of the defined
Near Field region. The region is contained within a cylindrical volume having the same diameter as the
antenna. Past the boundary of the Near Field region, the power density from the antenna decreases
linearly with respect to increasing distance. The distance to the end of the Near Field is determined
from the following equation:

                                   Extent of the Near Field:

                                               Rnf = D2 / (4λ)                          (2)
                                                             =    16.95    m

The maximum power density in the Near Field is determined from the following equation:

                                        Near Field Density:

                                     Snf = 16.0 η P / (π D2)                            (3)
                                                                                   2
                                                          =       1.920    mW/cm

3. Transition Region Calculation
The Transition Region is located between the Near and Far Field regions. The power density begins to
decrease linearly with increasing distance in the Transition region. While the power density decreases
inversely with distance in the Transition region, the power density decreases inversely with the square
of the distance in the Far Field region. The power density calculated in Section 1 is the highest power
density the antenna can produce in any of the regions away from the antenna. The power density at a
distance Rt is determined from the following equation:

                          Transition Region Power Density:

                                              St = Snf Rnf / Rt                         (4)
                                                                                   2
                                                             =    1.920    mW/cm




                                                    2


4. Far Field Distance Calculation
The distance to the Far Field Region is calculated using the following equation:

                               Distance to Far Field Region:

                                               Rff = 0.6 D2 / λ                            (5)
                                                              =   40.680   m

The maximum main beam power density in the far field is determined from the following equation:

                    On-axis Power Density in the Far Field:

                                         Sff = G P / (4 π Rff2)                            (6)
                                                                                   2
                                                             =    0.822    mW/cm

5. Region between the Main Reflector and the Ground
Assuming uniform illumination of the reflector surface, the power density between the antenna and the
ground is determined from the following equation:

             Power Density between Reflector and Ground:

                                              Sg = P / Asurface                            (7)
                                                                                       2
                                                             =    0.707        mW/cm




                                                     3


7. Summary of Calculations

 Table 3. Summary of Expected Radiation levels for Uncontrolled Environment
                                                                              Calculated
                                                                              Maximum
                                                                              Radiation
                                                                                              Hazard
                           Region                                Symbol         Power
                                                                                            Assessment
                                                                               Density
                                                                                Level
                                                                              (mW/cm2)
                                                                                              Potential
1. Main Reflector                                                 Ssurface       2.829
                                                                                               Hazard
                                                                                              Potential
2. Near Field                         (Rnf =     16.95 m)           Snf          1.920
                                                                                               Hazard
                                                                                              Potential
3. Transition Region (Rnf <Rt< Rff)                                 St           1.920
                                                                                               Hazard
                                                                                            Satisfies FCC
4. Far Field                          (Rff =     40.68 m)           Sff          0.822
                                                                                                 MPE
                                                                                            Satisfies FCC
5. Between Main Reflector and Ground                                Sg           0.707
                                                                                                 MPE

Table 4. Summary of Expected Radiation levels for Controlled Environment
                                                                              Calculated
                                                                              Maximum
                                                                              Radiation
                                                                                              Hazard
                           Region                                Symbol         Power
                                                                                            Assessment
                                                                               Density
                                                                                Level
                                                                                      2
                                                                              (mW/cm )
                                                                                            Satisfies FCC
1. Main Reflector                                                 Ssurface       2.829
                                                                                                 MPE
                                                                                            Satisfies FCC
2. Near Field                         (Rnf =     16.95 m)           Snf          1.920
                                                                                                 MPE
                                                                                            Satisfies FCC
3. Transition Region (Rnf <Rt< Rff)                                 St           1.920
                                                                                                 MPE
                                                                                            Satisfies FCC
4. Far Field                          (Rff =     40.68 m)           Sff          0.822
                                                                                                 MPE
                                                                                            Satisfies FCC
5. Between Main Reflector and Ground                                Sg           0.707
                                                                                                 MPE

It is the applicant’s responsibility to ensure that the public and operational personnel are not exposed to
harmful levels of radiation.




                                                     4


8. Conclusion
Based upon the above analysis, it is concluded that harmful levels of radiation may exist in those
regions noted for the Uncontrolled (Table 3) Environment and the Controlled Environment (Table 4).


The antennas will be in a secured facility and will be marked with the standard radiation hazard
warnings, as well as the area in the vicinity of the terminals to inform those in the general population,
who might be working or otherwise present in or near the direct path of the main beam.

The applicant will ensure that the main beam of the terminal antenna will be pointed at least one
diameter away from any building, or other obstacles in those area that exceed the MPE levels. Since
one diameter removed from the center of the main beam the levels are down by at least 20 dB, or by a
factor of 100, these potential hazards do not exist for either the public, or for earth station personnel.


Finally, the personnel operating the terminal antenna will not have access to areas that exceed the
MPE levels, while the antenna is in operation. The transmitter will be turned off during those periods of
maintenance, so that the MPE standard of 5.0 mW/cm2 will be complied with for those regions in close
proximity to the main reflector, which could be occupied by operating personnel.


 “The licensee shall take all necessary measures to ensure that the antennas do not create potential
exposure of humans to radiofrequency radiation in excess of the FCC exposure limits defined in 47
CFR 1.1307(b) and 1.1310 wherever such exposures might occur. Measures must be taken to ensure
compliance with limits for both occupational/controlled exposure and for general
population/uncontrolled exposure, as defined in these rule sections. Compliance can be accomplished
in most cases by appropriate restrictions such as fencing. Requirements for restrictions can be
determined by predictions based on calculations, modeling or by field measurements. The FCC's OET
Bulletin 65 (available on-line at www.fcc.gov/oet/rfsafety) provides information on predicting exposure
levels and on methods for ensuring compliance, including the use of warning and alerting signs and
protective equipment for workers.”




                                                     5


                                   ANNEX 1
                                  (MPE Levels)

a) Limits for General Population/Uncontrolled Exposure (MPE)
         Frequency Range (MHz)                       Power Density (mW/cm2)
                30-300                                        0.2
               300-1500                              Frequency(MHz)*(4.0/1200)
              1500-100,000                                      1

b) Limits for Occupational/Controlled Exposure (MPE)
          Frequency Range (MHz)                     Power Density (mW/cm2)
                   30-300                                     1
                  300-1500                         Frequency(MHz)*(4.0/1200)
              1500-100,000                                      5




                                                 6


Radiation Hazard Report
Analysis of Non-Ionizing Radiation for 1.8 m Earth Stations
This analysis provides the calculated non-ionizing radiation levels for a 1.8-meter earth station systems.

The methods and calculations performed in this analysis are based on the FCC Office of Engineering
and Technology Bulletin, No.65, October 1985 as revised in 1997 in Edition 97-01. The radiation safety
limits used in the analysis are in conformance with the FCC R&O 96-326 (Summarized in Annex 1).
There are separate exposure limits applicable to the General Population/Uncontrolled Environment and
the Occupational/Controlled Environment. The Maximum Permissible Exposure (MPE) limits for
persons in a General Population/Uncontrolled environment for the frequency band of this antenna, is 1
mW/cm2 for a 30 minute or lower time period as shown in Annex 1 (a). The MPE limit for persons in an
Occupational/Controlled environment for the frequency band of this antenna is 5 mW/cm2 for a 6
minute time or lower period as shown in Annex 1 (b). The purpose of this analysis described is to
determine the power flux density levels of the earth station at the main reflector surface, the near-field,
transition region, far-field, between the sub-reflector or feed and, at the main reflector surface, and
between the antenna edge and the ground and to compare these levels to the specified MPEs.



The parameters of the antennas that are the subject of this analysis are shown in Table 1.
Intermediate calculated values and constants are provided in Table 2.

 Table 1. Input Parameters Used for Determining Power Flux Densities
                 Parameter                     Symbol      Formula              Value           Units
Antenna Diameter                                 D          Input                1.8              m
Frequency                                         F         Input               14300           MHz
Transmit Power                                    P         Input                 12             W
Antenna Gain (dBi)                               Ges        Input                46.8            dBi

 Table 2. Calculated Values and Constants
                 Parameter                         Symbol       Formula          Value          Units
                                                                     2
Antenna Surface Area                                Asurface      πD /4           2.54          m^2
Wavelength                                              λ         300/F        0.020979          m
Antenna Gain (factor)                                   G        10Ges/10      47863.01          n/a
Pi                                                      π       Constant      3.1415927          n/a
Antenna Efficiency                                      η      Gλ2 /( π2D2)       0.66           n/a




                                                    1


1. Antenna Main Reflector Surface
The power density in the main reflector is determined from the Power level and the area of the main
reflector aperture. This is determined from the following equation:

              Power Density at the Main Reflector Surface:

                                         Ssurface = 4P/Asurface                         (1)
                                                                               2
                                                             =    18.863   W/m
                                                             =     1.886   mW/cm2

2. Near Field Calculation
Power Flux density is considered to be at a maximum value throughout the entire length of the defined
Near Field region. The region is contained within a cylindrical volume having the same diameter as the
antenna. Past the boundary of the Near Field region, the power density from the antenna decreases
linearly with respect to increasing distance. The distance to the end of the Near Field is determined
from the following equation:

                                   Extent of the Near Field:

                                               Rnf = D2 / (4λ)                          (2)
                                                             =    38.61    m

The maximum power density in the Near Field is determined from the following equation:

                                        Near Field Density:

                                     Snf = 16.0 η P / (π D2)                            (3)
                                                                                   2
                                                          =       1.243    mW/cm

3. Transition Region Calculation
The Transition Region is located between the Near and Far Field regions. The power density begins to
decrease linearly with increasing distance in the Transition region. While the power density decreases
inversely with distance in the Transition region, the power density decreases inversely with the square
of the distance in the Far Field region. The power density calculated in Section 1 is the highest power
density the antenna can produce in any of the regions away from the antenna. The power density at a
distance Rt is determined from the following equation:

                          Transition Region Power Density:

                                              St = Snf Rnf / Rt                         (4)
                                                                                   2
                                                             =    1.243    mW/cm




                                                    2


4. Far Field Distance Calculation
The distance to the Far Field Region is calculated using the following equation:

                               Distance to Far Field Region:

                                               Rff = 0.6 D2 / λ                            (5)
                                                              =   92.664   m

The maximum main beam power density in the far field is determined from the following equation:

                    On-axis Power Density in the Far Field:

                                         Sff = G P / (4 π Rff2)                            (6)
                                                                                   2
                                                             =    0.532    mW/cm

5. Region between the Main Reflector and the Ground
Assuming uniform illumination of the reflector surface, the power density between the antenna and the
ground is determined from the following equation:

             Power Density between Reflector and Ground:

                                              Sg = P / Asurface                            (7)
                                                                                       2
                                                             =    0.472        mW/cm




                                                     3


7. Summary of Calculations

 Table 3. Summary of Expected Radiation levels for Uncontrolled Environment
                                                                              Calculated
                                                                              Maximum
                                                                              Radiation
                                                                                              Hazard
                           Region                                Symbol         Power
                                                                                            Assessment
                                                                               Density
                                                                                Level
                                                                              (mW/cm2)
                                                                                              Potential
1. Main Reflector                                                 Ssurface       1.886
                                                                                               Hazard
                                                                                              Potential
2. Near Field                         (Rnf =     38.61 m)           Snf          1.243
                                                                                               Hazard
                                                                                              Potential
3. Transition Region (Rnf <Rt< Rff)                                 St           1.243
                                                                                               Hazard
                                                                                            Satisfies FCC
4. Far Field                          (Rff =     92.66 m)           Sff          0.532
                                                                                                 MPE
                                                                                            Satisfies FCC
5. Between Main Reflector and Ground                                Sg           0.472
                                                                                                 MPE

Table 4. Summary of Expected Radiation levels for Controlled Environment
                                                                              Calculated
                                                                              Maximum
                                                                              Radiation
                                                                                              Hazard
                           Region                                Symbol         Power
                                                                                            Assessment
                                                                               Density
                                                                                Level
                                                                                      2
                                                                              (mW/cm )
                                                                                            Satisfies FCC
1. Main Reflector                                                 Ssurface       1.886
                                                                                                 MPE
                                                                                            Satisfies FCC
2. Near Field                         (Rnf =     38.61 m)           Snf          1.243
                                                                                                 MPE
                                                                                            Satisfies FCC
3. Transition Region (Rnf <Rt< Rff)                                 St           1.243
                                                                                                 MPE
                                                                                            Satisfies FCC
4. Far Field                          (Rff =     92.66 m)           Sff          0.532
                                                                                                 MPE
                                                                                            Satisfies FCC
5. Between Main Reflector and Ground                                Sg           0.472
                                                                                                 MPE

It is the applicant’s responsibility to ensure that the public and operational personnel are not exposed to
harmful levels of radiation.




                                                     4


8. Conclusion
Based upon the above analysis, it is concluded that harmful levels of radiation may exist in those
regions noted for the Uncontrolled (Table 3) Environment and the Controlled Environment (Table 4).


The antennas will be in a secured facility and will be marked with the standard radiation hazard
warnings, as well as the area in the vicinity of the terminals to inform those in the general population,
who might be working or otherwise present in or near the direct path of the main beam.

The applicant will ensure that the main beam of the terminal antenna will be pointed at least one
diameter away from any building, or other obstacles in those area that exceed the MPE levels. Since
one diameter removed from the center of the main beam the levels are down by at least 20 dB, or by a
factor of 100, these potential hazards do not exist for either the public, or for earth station personnel.


Finally, the personnel operating the terminal antenna will not have access to areas that exceed the
MPE levels, while the antenna is in operation. The transmitter will be turned off during those periods of
maintenance, so that the MPE standard of 5.0 mW/cm2 will be complied with for those regions in close
proximity to the main reflector, which could be occupied by operating personnel.


 “The licensee shall take all necessary measures to ensure that the antennas do not create potential
exposure of humans to radiofrequency radiation in excess of the FCC exposure limits defined in 47
CFR 1.1307(b) and 1.1310 wherever such exposures might occur. Measures must be taken to ensure
compliance with limits for both occupational/controlled exposure and for general
population/uncontrolled exposure, as defined in these rule sections. Compliance can be accomplished
in most cases by appropriate restrictions such as fencing. Requirements for restrictions can be
determined by predictions based on calculations, modeling or by field measurements. The FCC's OET
Bulletin 65 (available on-line at www.fcc.gov/oet/rfsafety) provides information on predicting exposure
levels and on methods for ensuring compliance, including the use of warning and alerting signs and
protective equipment for workers.”




                                                     5


                                   ANNEX 1
                                  (MPE Levels)

a) Limits for General Population/Uncontrolled Exposure (MPE)
         Frequency Range (MHz)                       Power Density (mW/cm2)
                30-300                                        0.2
               300-1500                              Frequency(MHz)*(4.0/1200)
              1500-100,000                                      1

b) Limits for Occupational/Controlled Exposure (MPE)
          Frequency Range (MHz)                     Power Density (mW/cm2)
                   30-300                                     1
                  300-1500                         Frequency(MHz)*(4.0/1200)
              1500-100,000                                      5




                                                 6


Radiation Hazard Report
Analysis of Non-Ionizing Radiation for 1.8 m Earth Stations
This analysis provides the calculated non-ionizing radiation levels for a 1.8-meter earth station systems.

The methods and calculations performed in this analysis are based on the FCC Office of Engineering
and Technology Bulletin, No.65, October 1985 as revised in 1997 in Edition 97-01. The radiation safety
limits used in the analysis are in conformance with the FCC R&O 96-326 (Summarized in Annex 1).
There are separate exposure limits applicable to the General Population/Uncontrolled Environment and
the Occupational/Controlled Environment. The Maximum Permissible Exposure (MPE) limits for
persons in a General Population/Uncontrolled environment for the frequency band of this antenna, is 1
mW/cm2 for a 30 minute or lower time period as shown in Annex 1 (a). The MPE limit for persons in an
Occupational/Controlled environment for the frequency band of this antenna is 5 mW/cm2 for a 6
minute time or lower period as shown in Annex 1 (b). The purpose of this analysis described is to
determine the power flux density levels of the earth station at the main reflector surface, the near-field,
transition region, far-field, between the sub-reflector or feed and, at the main reflector surface, and
between the antenna edge and the ground and to compare these levels to the specified MPEs.



The parameters of the antennas that are the subject of this analysis are shown in Table 1.
Intermediate calculated values and constants are provided in Table 2.

 Table 1. Input Parameters Used for Determining Power Flux Densities
                 Parameter                     Symbol      Formula              Value           Units
Antenna Diameter                                 D          Input                1.8              m
Frequency                                         F         Input               14125           MHz
Transmit Power                                    P         Input                 12             W
Antenna Gain (dBi)                               Ges        Input                46.5            dBi

 Table 2. Calculated Values and Constants
                 Parameter                         Symbol       Formula          Value          Units
                                                                     2
Antenna Surface Area                                Asurface      πD /4           2.54          m^2
Wavelength                                              λ         300/F        0.021239          m
Antenna Gain (factor)                                   G        10Ges/10      44668.36          n/a
Pi                                                      π       Constant      3.1415927          n/a
Antenna Efficiency                                      η      Gλ2 /( π2D2)       0.63           n/a




                                                    1


1. Antenna Main Reflector Surface
The power density in the main reflector is determined from the Power level and the area of the main
reflector aperture. This is determined from the following equation:

              Power Density at the Main Reflector Surface:

                                         Ssurface = 4P/Asurface                         (1)
                                                                               2
                                                             =    18.863   W/m
                                                             =     1.886   mW/cm2

2. Near Field Calculation
Power Flux density is considered to be at a maximum value throughout the entire length of the defined
Near Field region. The region is contained within a cylindrical volume having the same diameter as the
antenna. Past the boundary of the Near Field region, the power density from the antenna decreases
linearly with respect to increasing distance. The distance to the end of the Near Field is determined
from the following equation:

                                   Extent of the Near Field:

                                               Rnf = D2 / (4λ)                          (2)
                                                             =    38.14    m

The maximum power density in the Near Field is determined from the following equation:

                                        Near Field Density:

                                     Snf = 16.0 η P / (π D2)                            (3)
                                                                                   2
                                                          =       1.189    mW/cm

3. Transition Region Calculation
The Transition Region is located between the Near and Far Field regions. The power density begins to
decrease linearly with increasing distance in the Transition region. While the power density decreases
inversely with distance in the Transition region, the power density decreases inversely with the square
of the distance in the Far Field region. The power density calculated in Section 1 is the highest power
density the antenna can produce in any of the regions away from the antenna. The power density at a
distance Rt is determined from the following equation:

                          Transition Region Power Density:

                                              St = Snf Rnf / Rt                         (4)
                                                                                   2
                                                             =    1.189    mW/cm




                                                    2


4. Far Field Distance Calculation
The distance to the Far Field Region is calculated using the following equation:

                               Distance to Far Field Region:

                                               Rff = 0.6 D2 / λ                            (5)
                                                              =   91.530   m

The maximum main beam power density in the far field is determined from the following equation:

                    On-axis Power Density in the Far Field:

                                         Sff = G P / (4 π Rff2)                            (6)
                                                                                   2
                                                             =    0.509    mW/cm

5. Region between the Main Reflector and the Ground
Assuming uniform illumination of the reflector surface, the power density between the antenna and the
ground is determined from the following equation:

             Power Density between Reflector and Ground:

                                              Sg = P / Asurface                            (7)
                                                                                       2
                                                             =    0.472        mW/cm




                                                     3


7. Summary of Calculations

 Table 3. Summary of Expected Radiation levels for Uncontrolled Environment
                                                                              Calculated
                                                                              Maximum
                                                                              Radiation
                                                                                              Hazard
                           Region                                Symbol         Power
                                                                                            Assessment
                                                                               Density
                                                                                Level
                                                                              (mW/cm2)
                                                                                              Potential
1. Main Reflector                                                 Ssurface       1.886
                                                                                               Hazard
                                                                                              Potential
2. Near Field                         (Rnf =     38.14 m)           Snf          1.189
                                                                                               Hazard
                                                                                              Potential
3. Transition Region (Rnf <Rt< Rff)                                 St           1.189
                                                                                               Hazard
                                                                                            Satisfies FCC
4. Far Field                          (Rff =     91.53 m)           Sff          0.509
                                                                                                 MPE
                                                                                            Satisfies FCC
5. Between Main Reflector and Ground                                Sg           0.472
                                                                                                 MPE

Table 4. Summary of Expected Radiation levels for Controlled Environment
                                                                              Calculated
                                                                              Maximum
                                                                              Radiation
                                                                                              Hazard
                           Region                                Symbol         Power
                                                                                            Assessment
                                                                               Density
                                                                                Level
                                                                                      2
                                                                              (mW/cm )
                                                                                            Satisfies FCC
1. Main Reflector                                                 Ssurface       1.886
                                                                                                 MPE
                                                                                            Satisfies FCC
2. Near Field                         (Rnf =     38.14 m)           Snf          1.189
                                                                                                 MPE
                                                                                            Satisfies FCC
3. Transition Region (Rnf <Rt< Rff)                                 St           1.189
                                                                                                 MPE
                                                                                            Satisfies FCC
4. Far Field                          (Rff =     91.53 m)           Sff          0.509
                                                                                                 MPE
                                                                                            Satisfies FCC
5. Between Main Reflector and Ground                                Sg           0.472
                                                                                                 MPE

It is the applicant’s responsibility to ensure that the public and operational personnel are not exposed to
harmful levels of radiation.




                                                     4


8. Conclusion
Based upon the above analysis, it is concluded that harmful levels of radiation may exist in those
regions noted for the Uncontrolled (Table 3) Environment and the Controlled Environment (Table 4).


The antennas will be in a secured facility and will be marked with the standard radiation hazard
warnings, as well as the area in the vicinity of the terminals to inform those in the general population,
who might be working or otherwise present in or near the direct path of the main beam.

The applicant will ensure that the main beam of the terminal antenna will be pointed at least one
diameter away from any building, or other obstacles in those area that exceed the MPE levels. Since
one diameter removed from the center of the main beam the levels are down by at least 20 dB, or by a
factor of 100, these potential hazards do not exist for either the public, or for earth station personnel.


Finally, the personnel operating the terminal antenna will not have access to areas that exceed the
MPE levels, while the antenna is in operation. The transmitter will be turned off during those periods of
maintenance, so that the MPE standard of 5.0 mW/cm2 will be complied with for those regions in close
proximity to the main reflector, which could be occupied by operating personnel.


 “The licensee shall take all necessary measures to ensure that the antennas do not create potential
exposure of humans to radiofrequency radiation in excess of the FCC exposure limits defined in 47
CFR 1.1307(b) and 1.1310 wherever such exposures might occur. Measures must be taken to ensure
compliance with limits for both occupational/controlled exposure and for general
population/uncontrolled exposure, as defined in these rule sections. Compliance can be accomplished
in most cases by appropriate restrictions such as fencing. Requirements for restrictions can be
determined by predictions based on calculations, modeling or by field measurements. The FCC's OET
Bulletin 65 (available on-line at www.fcc.gov/oet/rfsafety) provides information on predicting exposure
levels and on methods for ensuring compliance, including the use of warning and alerting signs and
protective equipment for workers.”




                                                     5


                                   ANNEX 1
                                  (MPE Levels)

a) Limits for General Population/Uncontrolled Exposure (MPE)
         Frequency Range (MHz)                       Power Density (mW/cm2)
                30-300                                        0.2
               300-1500                              Frequency(MHz)*(4.0/1200)
              1500-100,000                                      1

b) Limits for Occupational/Controlled Exposure (MPE)
          Frequency Range (MHz)                     Power Density (mW/cm2)
                   30-300                                     1
                  300-1500                         Frequency(MHz)*(4.0/1200)
              1500-100,000                                      5




                                                 6