Attachment Rad.Haz.Report

This document pretains to SES-LIC-20170201-00111 for License on a Satellite Earth Station filing.

IBFS_SESLIC2017020100111_1155417

                                                     Radiation Hazard Analysis



                                                                   2.4 Meter
                                                               Miami, Florida 33178

              Introduction
              A radiation hazard anaylsis is presented for a 2.4 meter ku band aperture antenna to be installed in MiamiFlorida at
              the CarnivalDoral. This Radiation Analysis calculates the non-ionizing radiation levels expected to be emitted from
              the earth station on a worse cases basis and is performed in accordance with the Federal Communications
              Commissions Office of Engineering and Technology (OET) Bulletin, No. 65.


              Requirements
              OET 65 outlines the maximum permissible exposure limits in two cases for operation in this frequency range.

                  1. The first case is the maximum level that a person may be exposed to in the general population. The exposure
                     limit is defined as a non-ionizing power level equal to 1 milliwatt per centimeter squared averaged over a
                     thirty minute period.
                  2. The second case is a controlled environment where the maximum permissible exposure limit must not exceed
                     5 milliwatts per centimeter squared averaged over any six minute period.

              Summary
              The results indicate that no significant hazard will be presented to the general population and will be fully mitigated
              in the controlled area by the use of procedures that require the removal of transmit power before accessing the area
              around the main reflector.


              Analysis
              This analysis was performed on seven zones with the results shown in Radiation Hazard Zones. The Table labeled
              Input Values provides the - input data required to perform the analysis. The table labeled OET 65 Calculated
              Values provides the intermediate calculation used to perform the assessment in accordance with OET 65. The
              Analysis is performed for each a the each of seven radiation zones as shown in figure 1 – Analysis Zones. These
              zones are:
                 1. Point between the feed and the sub-reflector
                 2. The power at the surface of the antenna
                 3. The power level between the main reflector and ground
                 4. The near-field or Fresnel region in which the maxima can be reached before the field starts to diminish with
                    distance
                 5. The Transition region where power begins to decrease inversely with distance from the antenna
                 6. The Far Field or Fraunhofer region where power decreases inversely with the square of the distance. This is
                    the point at which the antenna beam is fully collimated
                 7. The off axis level in the near field. This is defined as the area outside of the main beam removed and at least
                    one antenna diameter removed from the main beam




Generated 10/13/2016                                                  1 of 2                                               rad haz auto report-tk-mod


                                                          Radiation Hazard Analysis

                                        Operator:             Carnival
                             Location Designation:            Doral                              FCC Callsign:
                                          County:             Miami                                   SES ID:
                                            Town:             Miami                                      STA:
                                        State/Zip:            Florida          33178
                          Input Values                             Value           Unit                               Band          Frequency
                              D = Aperture Diameter                2.40             Meters                             L            1000-2000
                           d = Subreflector Diameter               0.056            Meters                              S           2000-4000
                                  G = Antenna Gain                  49                  dBi                            C            4000-8000
                                   FCC Designation                   ku             Band                               X           8000-12500
                                      F = Frequency               14.000             GHz                               Ku          12500-18000
                        P = Transmitter Power Watts:                89              Watts                              K           18000-25500
                  R ua = closest point to uncontrolled area          50            meters                              Ka          26500-40000
                  Elevation angle at closest point R ua              10            Degrees                             O           40000-50000
                                        Height (AGL)               2.00             meters                             V           50000-75000

                  OET 65 Calculated Values                       Formula            Value            Unit
                                                                      c
                                        λ= Wavelength                               0.0214     meters
                                                                      F
                                                                      (G/10)
                                   G = Antenna Gain              10              79432.82347   (W) linear
                                                                      2
                                                                  Gλ /4π
                           η = Apperture Efficiency                                     64%    percentage
                                                                  πD2/4
                                A = Area of reflector              πR2              4.524      meters 2
                                                                    πr
                                                                       2                          2
                             a = area of subreflector                              24.630      cm
                                                                      2
                                                                    D              67.245      meters
                           R nf = Near-Field Region
                                                                    4λ               12        Meters AGL
                                                                   >Rnf            67.245      >meters
                             R t = Transition Region
                                                                   <Rff            161.388     <meters
                                                                  0.6D2            161.388     meters
                             R ff = Far Field Region
                                                                     λ               28        Meters AGL

                                                                                                                          Exposure Limits
              Radiation Analysis Zone                           Formula             Level           Value        General Public   Occupational
                                                                                                                  <1mW/cm2         <5mW/cm2
                                                                    4P                                           >FCC MPE See     >FCC MPE See
      1                           Power Subreflector                              14453.867        mW/cm2
                                                                     a                                              Note 1           Note 2
                                                                    4P                                           >FCC MPE See     >FCC MPE See
      2                              Antenna Surface                                7.869          mW/cm2
                                                                     A                                              Note 1           Note 2
                                                                    P                                            >FCC MPE See
      3                     Main Reflector Ground                                   1.967          mW/cm2                           <FCC MPE
                                                                     A                                              Note 1
                                                                   4η P                                          >FCC MPE See     >FCC MPE See
      4            S nf =Near-Field Power Density                                   5.042          mW/cm2
                                                                     A                                              Note 1           Note 2
                                                                                                                 >FCC MPE See     >FCC MPE See
      5        S t = Max Transition Power Density                  < Snf            5.042          mW/cm2
                                                                                                                    Note 1           Note 2
                                                                    PG                                           >FCC MPE See
      6         S ff = Max Far field Power Density                                  2.160          mW/cm2                           <FCC MPE
                                                                  4πRff2                                            Note 3
      7           Off Access Level Near Field                   Snf - 20 dB        0.05042         mW/cm2          <FCC MPE         <FCC MPE

    Notes
          1. The antenna is installed in a controlled location access is restricted to authorized personnel only. The antenna is
            marked with RF Radiation Hazard signage.
          2. Inside the controlled area, MPE levels exceed the MPE exposure for occupational levels. The levels will be reduced
            to safe MPE by removing power to the transmitters when work is performed on or around the antenna. This area
            can only be accessed by qualified personnel.
          3. The field develops 2 meters above ground level at the minimum elevation angle which is not accessable to the
            general public.




Generated 10/13/2016                                                           2 of 2                                      rad haz auto report-tk-mod



Document Created: 2016-10-13 13:18:41
Document Modified: 2016-10-13 13:18:41

© 2024 FCC.report