Attachment Exhibit C

This document pretains to SES-LIC-20150625-00383 for License on a Satellite Earth Station filing.

IBFS_SESLIC2015062500383_1093437

                                          ISAT US Inc.
                                         FCC Form 312
                                            Exhibit C
                                    Radiation Hazard Analysis

1.0 Introduction

This Exhibit analyzes the non-ionizing radiation levels for the earth stations included in this
application. The analysis and calculations performed in this Exhibit comply with the methods
described in the FCC Office of Engineering and Technology Bulletin, No. 65 first published in 1985
and revised in 1997 in Edition 97-01.

Bulletin No. 65 and the FCC R&O 96-326 specifies two Maximum Permissible Exposure (MPE)
limits that are dependent on the situation in which the exposure takes place and/or the status of the
individuals who are subject to the exposure. These are described below:

• General Population/Uncontrolled environment MPE limit is 1 mW/cm2. The General Population /
Uncontrolled MPE is a function of transmit frequency and is for an exposure period of thirty minutes
or less.

• Occupational/Controlled environment MPE limit is 5 mW/cm2. The Occupational MPE is a function
of transmit frequency and is for an exposure period of six minutes or less.

The analysis determined the power flux density levels of the earth station in the 1) far-field, 2) near-
field, 3) transition region, 4) region between the feed and main reflector surface, 5) at the main
reflector surface, and 6) between the antenna edge and the ground. The summary of results and
discussion is provided in Section 2 and the detailed analyses are provided in Section 3.

Section 2.0 – Summary of Results

The terminals proposed in this application are for commercial and government uses and intended to be
operated by professional personnel. The analysis of the non-ionizing radiation levels provided in
Section 3 assumed the maximum allowed input power to antenna of 5W and a 100% duty cycle
resulting in worst case radiation levels. In a significant number of deployments the terminals duty
cycle would be below 100% and the actual power required would be lower than the 5W maximum
resulting in lower radiation levels than those calculated. As with any directional antenna the
maximum level of non-ionizing radiation is in the main beam of the antenna that is pointed to the
satellite. As one moves around the antenna to the side lobes and back lobes the radiation levels
decrease significantly. Thus, the maximum radiation level from an antenna occurs in a limited area in
the direction the antenna is pointed to. The terminals proposed in this application are designed to
cease transmitting if the receive signal from the satellite is blocked, which could be caused by a
person standing in front of the terminal or from other blockage. If the receive signal is blocked, the
transmitter is shut down and will not resume operating until the signal from the satellite is reacquired.
This operational feature of the terminal minimizes the potential for human radiation exposure. The
terminals will be turned off prior to any maintenance being conducted when a person may need to be
in close proximity to the feed flange and main reflector.

The Tables below summarize the result for each antenna terminal type. As shown all but the two
smaller antenna terminals meet the controlled environment limit of ≤ 5 mW/cm2 except at the feed
flange. For the two smaller antennas the level is also exceeded at the main reflector. In a controlled
environment technicians are trained and procedures are put in place to ensure that a safe distance is
maintained from the antenna while in operation. These procedures can include fencing around the


terminal, limits on the operation of the terminal, warning signs and other means of alerting workers,
as appropriate, for the specific deployment scenario.

The terminals when operating with maximum input power and a 100% duty cycle vary in meeting the
uncontrolled environment limit of ≤ 1 mW/cm2. For the 1.8 m antenna the limit is met except at the
feed flange, however for most of the other antennas the level is exceeded except in the far field. As
described above the maximum radiation levels occur in a limited area in the direction the antenna is
pointed to and the automatic shut off capability of the terminal when the satellite receive signal is
blocked will reduce potential human exposure. In addition, the terminals proposed in this application
are for commercial and government use and, given the price points, are not intended to be used by
consumers or widely deployed for use by the general public. Personnel operating these terminals will
be trained in how to operate the terminal safely. Furthermore, the manuals for these terminals will
explicitly indicate that precautions, such has not standing in front of the terminal, that are necessary to
limit potential exposure. The terminals will also clearly be marked to ensure that the terminal
operator and the general public are aware of the potential radiation exposure and the need to avoid
physical proximity to the terminal. It is noted that the highest radiation levels are at the feed flange
and main reflector. The feed flange is a very small area of the terminal antenna and it is extremely
unlikely that a person would be near the feed flange or the main reflector while the terminal is in
operation. Any blockage of the signal from the satellite in these areas would cause the terminal to
cease transmitting until the blockage is removed and the signal from the satellite is reacquired.

 Cobham 3075 & 5075
                                                      Limit Controlled
                                                        Environment            Limit
                                  Calculated Power
                      Distance                         ≤ 5 mW/cm2          Uncontrolled
 Region                               Density
                        (m)                                                Environment
                                     (mW/cm2)
                                                                           ≤ 1 mW/cm2

 Near Field             13.7             2.3            Meets Limit        Exceeds Limit
 Far Field              32.9             1.0            Meets Limit         Meets Limit

 Transition Region                       2.3            Meets Limit        Exceeds Limit
                        13.7
 Feed Flange            NA             1370.9          Exceeds Limit       Exceeds Limit
 Main Reflector          NA              4.7            Meets Limit        Exceeds Limit

 Cobham 7100
                                                      Limit Controlled
                                                        Environment            Limit
                                  Calculated Power
                      Distance                         ≤ 5 mW/cm2          Uncontrolled
 Region                               Density
                        (m)                                                Environment
                                     (mW/cm2)
                                                                           ≤ 1 mW/cm2

 Near Field             25.0             1.6            Meets Limit        Exceeds Limit
 Far Field              60.0             0.7            Meets Limit         Meets Limit

 Transition Region                       1.6            Meets Limit        Exceeds Limit
                        25.0
 Feed Flange            NA              698.0          Exceeds Limit       Exceeds Limit
 Main Reflector          NA              2.5            Meets Limit        Exceeds Limit


 L3 Cheetah II
                                                      Limit Controlled
                                                        Environmen             Limit
                                  Calculated Power
                      Distance                         ≤ 5 mW/cm2          Uncontrolled
 Region                               Density
                        (m)                                                Environment
                                     (mW/cm2)
                                                                           ≤ 1 mW/cm2


Near Field            18.1           2.4            Meets Limit      Exceeds Limit
Far Field             43.4           1.0            Meets Limit       Meets Limit
Transition Region     18.1           2.4            Meets Limit      Exceeds Limit
Feed Flange           NA            873.3          Exceeds Limit     Exceeds Limit
Main Reflector        NA             3.5            Meets Limit      Exceeds Limit




L3 Hawkeye III Lite
                                                  Limit Controlled
                                                    Environment          Limit
                               Calculated Power
                    Distance                       ≤ 5 mW/cm2        Uncontrolled
Region                             Density
                      (m)                                            Environment
                                  (mW/cm2)
                                                                     ≤ 1 mW/cm2

Near Field            36.0           1.1            Meets Limit      Exceeds Limit
Far Field             86.4           0.5            Meets Limit       Meets Limit
Transition Region     36.0           1.1            Meets Limit      Exceeds Limit
Feed Flange           NA            873.3          Exceeds Limit     Exceeds Limit
Main Reflector        NA             1.8            Meets Limit      Exceeds Limit


Paradigm/SWT Connect 70
                                                  Limit Controlled
                                                    Environment          Limit
                               Calculated Power
                    Distance                       ≤ 5 mW/cm2        Uncontrolled
Region                             Density
                      (m)                                            Environment
                                  (mW/cm2)
                                                                     ≤ 1 mW/cm2

Near Field            12.1           3.3            Meets Limit      Exceeds Limit
Far Field             29.0           1.4            Meets Limit      Exceeds Limit
Transition Region     12.1           3.3            Meets Limit      Exceeds Limit
Feed Flange           NA            679.9          Exceeds Limit     Exceeds Limit
Main Reflector        NA             5.3           Exceeds Limit     Exceeds Limit

SWT ATOM 65/GX/01 ATOM 65AAGX/01
                                                  Limit Controlled
                                                    Environment          Limit
                               Calculated Power
                    Distance                       ≤ 5 mW/cm2        Uncontrolled
Region                             Density
                      (m)                                            Environment
                                  (mW/cm2)
                                                                     ≤ 1 mW/cm2

Near Field            10.6           2.8            Meets Limit      Exceeds Limit
Far Field             25.4           1.2            Meets Limit      Exceeds Limit
Transition Region     10.6           2.8            Meets Limit      Exceeds Limit
Feed Flange           NA           1471.5          Exceeds Limit     Exceeds Limit
Main Reflector        NA             6.0           Exceeds Limit     Exceeds Limit


 Paradigm/SWT Connect 100, 100T, Sky 98
                                                  Limit Controlled
                                                    Environment          Limit
                               Calculated Power
                    Distance                       ≤ 5 mW/cm2        Uncontrolled
Region                             Density
                      (m)                                            Environment
                                  (mW/cm2)
                                                                     ≤ 1 mW/cm2


Near Field           21.8            1.5            Meets Limit      Exceeds Limit
Far Field            52.3            0.6            Meets Limit       Meets Limit
Transition Region    21.8            1.5            Meets Limit      Exceeds Limit
Feed Flange          NA             679.9          Exceeds Limit     Exceeds Limit
Main Reflector        NA             2.9            Meets Limit      Exceeds Limit




Paradigm/SWT Connect 180, Sky 180GX/01
                                                  Limit Controlled
                                                    Environment          Limit
                               Calculated Power
                    Distance                       ≤ 5 mW/cm2        Uncontrolled
Region                             Density
                      (m)                                            Environment
                                  (mW/cm2)
                                                                     ≤ 1 mW/cm2

Near Field           81.0            0.5            Meets Limit      Meets Limit
Far Field            194.4           0.2            Meets Limit      Meets Limit
Transition Region    81.0            0.5            Meets Limit      Meets Limit
Feed Flange          NA            1327.4          Exceeds Limit     Exceeds Limit
Main Reflector        NA             0.8            Meets Limit       Meets Limit


Section 3.0 – Detailed calculations

3.1 Cobham 3075/5075

"Input Parameters" Table from page 51
Input Parameter                                   Value        Units    Symbol
Antenna Diameter                                       0.74    m        D
Antenna Transmit Gain                                  44.2    dBi      G
Transmit Frequency                                    30000    MHz      f
Antenna Feed Flange Diameter                           4.31    cm       d
Power Input to the Antenna                                5    Watts    P

"Calculated Parameters" table from page 52
Calculated Parameter                              Value        Units    Symbol   Formula
Antenna Surface Area                                  0.4301   m²       A        πD²/4
Area of Antenna Flange                               14.5892   cm²      a        πd²/4
Antenna Efficiency                                    0.4867   real     η        gλ²/(π²D²)
Gain Factor                                       26302.6799   real     g        10^(G/10)
Wavelength                                            0.0100   m        λ        300/f

"Antenna Field Definitions" table from page 54
Calculated Parameter                              Value      Units      Symbol   Formula
Near-Field Distance                                    13.69 m          Rnf      D²/(4λ)
Distance to Far-Field                                 32.856 m          Rff      0.6D²/λ
Distance of Transition Range                           13.69 m          Rt       Rt=Rnf

Power Flux Density table from page 54
Calculated Parameter                              Value        Units    Symbol   Formula
Power Density in the Near Field                       2.2634   mW/cm²   Snf      16ηP/(πD²)
Power Density in the Far Field                        0.9695   mW/cm²   Sff      gP/(4πRff²)
Power Density in the Transition Region                2.2634   mW/cm²   St       Snf*Rnf/Rt

Flange Power Density table from page 54
Calculated Parameter                              Value      Units      Symbol   Formula
Power Density at the Feed Flange                   1370.8767 mW/cm²     Sfa      4P/a

Main Reflector Power Density table from page 54
Calculated Parameter                              Value      Units      Symbol Formula
Power Density at Main Reflector                       4.6504 mW/cm²     Ssurface 4P/A

Main Reflector Power Density table from page 54
Calculated Parameter                              Value      Units      Symbol   Formula
Power Density between Reflector and Ground            1.1626 mW/cm²     Sg       P/A


3.2 Cobham 7100

"Input Parameters" Table from page 51
Input Parameter                                  Value        Units    Symbol
Antenna Diameter                                         1    m        D
Antenna Transmit Gain                                 47.9    dBi      G
Transmit Frequency                                   30000    MHz      f
Antenna Feed Flange Diameter                          6.04    cm       d
Power Input to the Antenna                               5    Watts    P

"Calculated Parameters" table from page 52
Calculated Parameter                             Value        Units    Symbol   Formula
Antenna Surface Area                                 0.7854   m²       A        πD²/4
Area of Antenna Flange                              28.6517   cm²      a        πd²/4
Antenna Efficiency                                   0.6248   real     η        gλ²/(π²D²)
Gain Factor                                      61659.5002   real     g        10^(G/10)
Wavelength                                           0.0100   m        λ        300/f

"Antenna Field Definitions" table from page 54
Calculated Parameter                             Value        Units    Symbol   Formula
Near-Field Distance                                      25.0 m        Rnf      D²/(4λ)
Distance to Far-Field                                    60.0 m        Rff      0.6D²/λ
Distance of Transition Range                             25.0 m        Rt       Rt=Rnf

Power Flux Density table from page 54
Calculated Parameter                             Value        Units    Symbol   Formula
Power Density in the Near Field                      1.5910   mW/cm²   Snf      16ηP/(πD²)
Power Density in the Far Field                       0.6815   mW/cm²   Sff      gP/(4πRff²)
Power Density in the Transition Region               1.5910   mW/cm²   St       Snf*Rnf/Rt

Flange Power Density table from page 54
Calculated Parameter                             Value      Units      Symbol   Formula
Power Density at the Feed Flange                   698.0380 mW/cm²     Sfa      4P/a

Main Reflector Power Density table from page 54
Calculated Parameter                            Value      Units       Symbol Formula
Power Density at Main Reflector                     2.5466 mW/cm²      Ssurface 4P/A

Main Reflector Power Density table from page 54
Calculated Parameter                            Value      Units       Symbol   Formula
Power Density between Reflector and Ground          0.6366 mW/cm²      Sg       P/A


3.3 L3 Cheetah II

"Input Parameters" Table from page 51
Input Parameter                              Value          Units    Symbol
Antenna Diameter                                   0.85     m         D
Antenna Transmit Gain                              46.8     dBi       G
Transmit Frequency                                30000     MHz       f
Antenna Feed Flange Diameter                        5.4     cm        d
Power Input to the Antenna                            5     Watts     P

"Calculated Parameters" table from page 52
Calculated Parameter                       Value            Units    Symbol     Formula
Antenna Surface Area                           0.5674       m²       A          πD²/4
Area of Antenna Flange                        22.9015       cm²      a          πd²/4
Antenna Efficiency                             0.6713       real     η          gλ²/(π²D²)
Gain Factor                                47863.0092       real     g          10^(G/10)
Wavelength                                     0.0100       m        λ          300/f

"Antenna Field Definitions" table from page 54
Calculated Parameter                          Value         Units    Symbol     Formula
Near-Field Distance                              18.0625    m        Rnf        D²/(4λ)
Distance to Far-Field                               43.35   m        Rff        0.6D²/λ
Distance of Transition Range                     18.0625    m        Rt         Rt=Rnf

Power Flux Density table from page 54
Calculated Parameter                         Value          Units    Symbol     Formula
Power Density in the Near Field                  2.3659     mW/cm²   Snf        16ηP/(πD²)
Power Density in the Far Field                   1.0134     mW/cm²   Sff        gP/(4πRff²)
Power Density in the Transition Region           2.3659     mW/cm²   St         Snf*Rnf/Rt

Flange Power Density table from page 54
Calculated Parameter                         Value      Units        Symbol     Formula
Power Density at the Feed Flange               873.3039 mW/cm²       Sfa        4P/a

Main Reflector Power Density table from page 54
Calculated Parameter                        Value      Units         Symbol     Formula
Power Density at Main Reflector                 3.5246 mW/cm²        Ssurface   4P/A

Main Reflector Power Density table from page 54
Calculated Parameter                        Value      Units         Symbol     Formula
Power Density between Reflector and
Ground                                          0.8812 mW/cm²        Sg         P/A


3.4 L3 Hawkeye III

"Input Parameters" Table from page 51
Input Parameter                           Value         Units    Symbol
Antenna Diameter                                  1.2   m        D
Antenna Transmit Gain                            49.4   dBi      G
Transmit Frequency                              30000   MHz      f
Antenna Feed Flange Diameter                      5.4   cm       d
Power Input to the Antenna                          5   Watts    P

"Calculated Parameters" table from page 52
Calculated Parameter                       Value        Units    Symbol     Formula
Antenna Surface Area                           1.1309   m²       A          πD²/4
Area of Antenna Flange                        22.9015   cm²      a          πd²/4
Antenna Efficiency                             0.6129   real     η          gλ²/(π²D²)
Gain Factor                                 87096.359   real     g          10^(G/10)
Wavelength                                     0.0100   m        λ          300/f

"Antenna Field Definitions" table from page 54
Calculated Parameter                         Value      Units    Symbol     Formula
Near-Field Distance                                 36 m         Rnf        D²/(4λ)
Distance to Far-Field                              86.4 m        Rff        0.6D²/λ
Distance of Transition Range                        36 m         Rt         Rt=Rnf

Power Flux Density table from page 54
Calculated Parameter                      Value         Units    Symbol     Formula
Power Density in the Near Field               1.0838    mW/cm²   Snf        16ηP/(πD²)
Power Density in the Far Field                0.4642    mW/cm²   Sff        gP/(4πRff²)
Power Density in the Transition Region        1.0838    mW/cm²   St         Snf*Rnf/Rt

Flange Power Density table from page 54
Calculated Parameter                      Value      Units       Symbol     Formula
Power Density at the Feed Flange            873.3039 mW/cm²      Sfa        4P/a

Main Reflector Power Density table from page 54
Calculated Parameter                        Value      Units     Symbol     Formula
Power Density at Main Reflector                 1.7684 mW/cm²    Ssurface   4P/A

Main Reflector Power Density table from page 54
Calculated Parameter                        Value      Units     Symbol     Formula
Power Density between
Reflector and Ground                            0.4421 mW/cm²    Sg         P/A


3.5 Paradigm/SWT Connect 70

"Input Parameters" Table from page 51
Input Parameter                              Value         Units    Symbol
Antenna Diameter                                  0.695    m        D
Antenna Transmit Gain                              44.8    dBi      G
Transmit Frequency                                30000    MHz      f
Antenna Feed Flange Diameter                       6.12    cm       d
Power Input to the Antenna                            5    Watts    P

"Calculated Parameters" table from page 52
Calculated Parameter                         Value         Units    Symbol     Formula
Antenna Surface Area                             0.3794    m²       A          πD²/4
Area of Antenna Flange                          29.4157    cm²      a          πd²/4
Antenna Efficiency                               0.6335    real     η          gλ²/(π²D²)
Gain Factor                                  30199.5172    real     g          10^(G/10)
Wavelength                                       0.0100    m        λ          300/f

"Antenna Field Definitions" table from page 54
Calculated Parameter                          Value        Units    Symbol     Formula
Near-Field Distance                            12.075625   m        Rnf        D²/(4λ)
Distance to Far-Field                            28.9815   m        Rff        0.6D²/λ
Distance of Transition Range                   12.075625   m        Rt         Rt=Rnf

Power Flux Density table from page 54
Calculated Parameter                         Value         Units    Symbol     Formula
Power Density in the Near Field                  3.3399    mW/cm²   Snf        16ηP/(πD²)
Power Density in the Far Field                   1.4306    mW/cm²   Sff        gP/(4πRff²)
Power Density in the Transition Region           3.3399    mW/cm²   St         Snf*Rnf/Rt

Flange Power Density table from page 54
Calculated Parameter                         Value      Units       Symbol     Formula
Power Density at the Feed Flange               679.9079 mW/cm²      Sfa        4P/a

Main Reflector Power Density table from page 54
Calculated Parameter                         Value      Units       Symbol     Formula
Power Density at Main Reflector                  5.2721 mW/cm²      Ssurface   4P/A

Main Reflector Power Density table from page 54
Calculated Parameter                         Value      Units       Symbol     Formula
Power Density between Reflector and
Ground                                           1.3180 mW/cm²      Sg         P/A


3.6 SWT ATOM 65/GX/01 ATOM 65AAGX/01

"Input Parameters" Table from page 51
Input Parameter                             Value          Units    Symbol
Antenna Diameter                                  0.65     m        D
Antenna Transmit Gain                             42.8     dBi      G
Transmit Frequency                               30000     MHz      f
Antenna Feed Flange Diameter                      4.16     cm       d
Power Input to the Antenna                           5     Watts    P

"Calculated Parameters" table from page 52
Calculated Parameter                       Value           Units    Symbol     Formula
Antenna Surface Area                           0.3318      m²       A          πD²/4
Area of Antenna Flange                        13.5914      cm²      a          πd²/4
Antenna Efficiency                             0.4570      real     η          gλ²/(π²D²)
Gain Factor                                19054.6072      real     g          10^(G/10)
Wavelength                                     0.0100      m        λ          300/f

"Antenna Field Definitions" table from page 54
Calculated Parameter                         Value         Units    Symbol     Formula
Near-Field Distance                             10.5625    m        Rnf        D²/(4λ)
Distance to Far-Field                              25.35   m        Rff        0.6D²/λ
Distance of Transition Range                    10.5625    m        Rt         Rt=Rnf

Power Flux Density table from page 54
Calculated Parameter                        Value          Units    Symbol     Formula
Power Density in the Near Field                 2.7544     mW/cm²   Snf        16ηP/(πD²)
Power Density in the Far Field                  1.1798     mW/cm²   Sff        gP/(4πRff²)
Power Density in the Transition Region          2.7544     mW/cm²   St         Snf*Rnf/Rt

Flange Power Density table from page 54
Calculated Parameter                        Value      Units        Symbol     Formula
Power Density at the Feed Flange             1471.5203 mW/cm²       Sfa        4P/a

Main Reflector Power Density table from page 54
Calculated Parameter                        Value      Units        Symbol     Formula
Power Density at Main Reflector                 6.0273 mW/cm²       Ssurface   4P/A

Main Reflector Power Density table from page 54
Calculated Parameter                        Value      Units        Symbol     Formula
Power Density between Reflector and
Ground                                          1.5068 mW/cm²       Sg         P/A


3.7 Paradigm/SWT Connect 100, 100T, Sky 98

"Input Parameters" Table from page 51
Input Parameter                            Value          Units    Symbol
Antenna Diameter                                 0.934    m        D
Antenna Transmit Gain                             46.5    dBi      G
Transmit Frequency                               30000    MHz      f
Antenna Feed Flange Diameter                      6.12    cm       d
Power Input to the Antenna                           5    Watts    P

"Calculated Parameters" table from page 52
Calculated Parameter                       Value          Units    Symbol     Formula
Antenna Surface Area                           0.6851     m²       A          πD²/4
Area of Antenna Flange                        29.4157     cm²      a          πd²/4
Antenna Efficiency                             0.5188     real     η          gλ²/(π²D²)
Gain Factor                                44668.3592     real     g          10^(G/10)
Wavelength                                     0.0100     m        λ          300/f

"Antenna Field Definitions" table from page 54
Calculated Parameter                         Value        Units    Symbol     Formula
Near-Field Distance                             21.8089   m        Rnf        D²/(4λ)
Distance to Far-Field                          52.34136   m        Rff        0.6D²/λ
Distance of Transition Range                    21.8089   m        Rt         Rt=Rnf

Power Flux Density table from page 54
Calculated Parameter                       Value          Units    Symbol     Formula
Power Density in the Near Field                1.5146     mW/cm²   Snf        16ηP/(πD²)
Power Density in the Far Field                 0.6488     mW/cm²   Sff        gP/(4πRff²)
Power Density in the Transition Region         1.5146     mW/cm²   St         Snf*Rnf/Rt

Flange Power Density table from page 54
Calculated Parameter                       Value      Units        Symbol     Formula
Power Density at the Feed Flange             679.9079 mW/cm²       Sfa        4P/a

Main Reflector Power Density table from page 54
Calculated Parameter                        Value      Units       Symbol     Formula
Power Density at Main Reflector                 2.9192 mW/cm²      Ssurface   4P/A

Main Reflector Power Density table from page 54
Calculated Parameter                        Value      Units       Symbol     Formula
Power Density between Reflector and
Ground                                          0.7298 mW/cm²      Sg         P/A


3.8 Paradigm/SWT Connect 180, Sky 180

"Input Parameters" Table from page 51
Input Parameter                                   Value           Units   Symbol
Antenna Diameter                                            1.8   m       D
Antenna Transmit Gain                                      52.4   dBi     G
Transmit Frequency                                        30000   MHz     f
Antenna Feed Flange Diameter                               4.38   cm      d
Power Input to the Antenna                                    5   Watts   P

"Calculated Parameters" table from page 52
Calculated Parameter                              Value           Units   Symbol     Formula
Antenna Surface Area                                   2.5446     m²      A          πD²/4
Area of Antenna Flange                                15.0669     cm²     a          πd²/4
Antenna Efficiency                                     0.5435     real    η          gλ²/(π²D²)
Gain Factor                                       173780.0829     real    g          10^(G/10)
Wavelength                                             0.0100     m       λ          300/f

"Antenna Field Definitions" table from page 54
Calculated Parameter                              Value         Units     Symbol     Formula
Near-Field Distance                                         81 m          Rnf        D²/(4λ)
Distance to Far-Field                                     194.4 m         Rff        0.6D²/λ
Distance of Transition Range                                81 m          Rt         Rt=Rnf

Power Flux Density table from page 54
Calculated Parameter                              Value          Units    Symbol     Formula
Power Density in the Near Field                           0.4272 mW/cm²   Snf        16ηP/(πD²)
Power Density in the Far Field                            0.1830 mW/cm²   Sff        gP/(4πRff²)
Power Density in the Transition Region                    0.4272 mW/cm²   St         Snf*Rnf/Rt

Flange Power Density table from page 54
Calculated Parameter                              Value        Units      Symbol     Formula
Power Density at the Feed Flange                     1327.4088 mW/cm²     Sfa        4P/a

Main Reflector Power Density table from page 54
Calculated Parameter                              Value          Units    Symbol     Formula
Power Density at Main Reflector                           0.7860 mW/cm²   Ssurface   4P/A

Main Reflector Power Density table from page 54
Calculated Parameter                              Value          Units    Symbol     Formula
Power Density between Reflector and Ground                0.1965 mW/cm²   Sg         P/A



Document Created: 2015-06-22 16:54:19
Document Modified: 2015-06-22 16:54:19

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC