Radiation Hazard Report                                                           Page 1 of 20


      Analysis of Non-Ionizing Radiation for a 3.5-Meter Earth
                          Station System
This report analyzes the non-ionizing radiation levels for a 3.5-meter earth station system. The
analysis and calculations performed in this report comply with the methods described in the FCC
Office of Engineering and Technology Bulletin, No. 65 first published in 1985 and revised in 1997
in Edition 97-01. The radiation safety limits used in the analysis are in conformance with the FCC
R&O 96-326. Bulletin No. 65 and the FCC R&O specifies that there are two separate tiers of
exposure limits that are dependant on the situation in which the exposure takes place and/or the
status of the individuals who are subject to the exposure. The Maximum Permissible Exposure
(MPE) limits for persons in a General Population/Uncontrolled environment are shown in Table 1.
The General Population/Uncontrolled MPE is a function of transmit frequency and is for an
exposure period of thirty minutes or less. The MPE limits for persons in an
Occupational/Controlled environment are shown in Table 2. The Occupational MPE is a function of
transmit frequency and is for an exposure period of six minutes or less. The purpose of the
analysis described in this report is to determine the power flux density levels of the earth station in
the far-field, near-field, transition region, between the subreflector or feed and main reflector
surface, at the main reflector surface, and between the antenna edge and the ground and to
compare these levels to the specified MPEs.

               Table 1. Limits for General Population/Uncontrolled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              0.2
                         300-1500                  Frequency (MHz)*(0.8/1200)
                       1500-100,000                           1.0

                    Table 2. Limits for Occupational/Controlled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              1.0
                         300-1500                  Frequency (MHz)*(4.0/1200)
                       1500-100,000                           5.0

          Table 3. Formulas and Parameters Used for Determining Power Flux Densities
     Parameter                    Symbol           Formula                  Value           Units
     Antenna Diameter                D               Input                   3.5            m
     Antenna Surface Area          Asurface         π D2 / 4                 9.62           m2
     Subreflector Diameter          Dsr              Input                   36.5           cm
     Area of Subreflector           Asr             π Dsr 2/4             1044.63           cm2
     Frequency                       F               Input                  14250           MHz
     Wavelength                      λ              300 / F               0.021053          m
     Transmit Power                  P               Input                 400.00           W
     Antenna Gain (dBi)             Ges              Input                   52.3           dBi
     Antenna Gain (factor)           G              10Ges/10              169824.4          n/a
     Pi                              π             Constant              3.1415927          n/a
     Antenna Efficiency              η             Gλ2/(π2D2)                0.62           n/a


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 2 of 20




1.      Far Field Distance Calculation

The distance to the beginning of the far field can be determined from the following equation:

     Distance to the Far Field Region                       Rff = 0.60 D2 / λ                    (1)
                                                                = 349.1 m

The maximum main beam power density in the far field can be determined from the following
equation:

     On-Axis Power Density in the Far Field                 Sff = G P / (4 π Rff 2)              (2)
                                                                = 44.349 W/m2
                                                                = 4.435 mW/cm2

2.      Near Field Calculation

Power flux density is considered to be at a maximum value throughout the entire length of the
defined Near Field region. The region is contained within a cylindrical volume having the same
diameter as the antenna. Past the boundary of the Near Field region, the power density from the
antenna decreases linearly with respect to increasing distance.

The distance to the end of the Near Field can be determined from the following equation:

     Extent of the Near Field                               Rnf = D2 / (4 λ)                     (3)
                                                                = 145.5 m

The maximum power density in the Near Field can be determined from the following equation:

     Near Field Power Density                               Snf = 16.0 η P / (π D2)              (4)
                                                                = 103.531 W/m2
                                                                = 10.353 mW/cm2

3.      Transition Region Calculation

The Transition region is located between the Near and Far Field regions. The power density
begins to decrease linearly with increasing distance in the Transition region. While the power
density decreases inversely with distance in the Transition region, the power density decreases
inversely with the square of the distance in the Far Field region. The maximum power density in
the Transition region will not exceed that calculated for the Near Field region. The power density
calculated in Section 1 is the highest power density the antenna can produce in any of the regions
away from the antenna. The power density at a distance Rt can be determined from the following
equation:

     Transition Region Power Density                        St = Snf Rnf / Rt                    (5)
                                                               = 10.353 mW/cm2


                                                                              Exhibit
Radiation Hazard Report                                                       Page 3 of 20



4.      Region between the Main Reflector and the Subreflector

Transmissions from the feed assembly are directed     toward the subreflector surface, and are
reflected back toward the main reflector. The most    common feed assemblies are waveguide
flanges, horns or subreflectors. The energy between   the subreflector and the reflector surfaces
can be calculated by determining the power density    at the subreflector surface. This can be
determined from the following equation:

     Power Density at the Subreflector                    Ssr = 4000 P / Asr                 (6)
                                                              = 1531.647 mW/cm2

5.      Main Reflector Region

The power density in the main reflector is determined in the same manner as the power density at
the subreflector. The area is now the area of the main reflector aperture and can be determined
from the following equation:

     Power Density at the Main Reflector Surface      Ssurface = 4 P / Asurface              (7)
                                                               = 166.301 W/m2
                                                               = 16.630 mW/cm2


6.      Region between the Main Reflector and the Ground

Assuming uniform illumination of the reflector surface, the power density between the antenna and
the ground can be determined from the following equation:

     Power Density between Reflector and Ground           Sg = P / Asurface                  (8)
                                                             = 41.575 W/m2
                                                             = 4.158 mW/cm2


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 4 of 20



7.     Summary of Calculations

           Table 4. Summary of Expected Radiation levels for Uncontrolled Environment
                                            Calculated Maximum
                                       Radiation Power Density Level
Region                                              (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 349.1 m)                    Sff         4.435             Potential Hazard
2. Near Field (Rnf = 145.5 m)                   Snf        10.353             Potential Hazard
3. Transition Region (Rnf < Rt < Rff)           St         10.353             Potential Hazard
4. Between Main Reflector and                   Ssr      1531.647             Potential Hazard
    Subreflector
5. Main Reflector                               Ssurface   16.630             Potential Hazard
6. Between Main Reflector and Ground            Sg          4.158             Potential Hazard

            Table 5. Summary of Expected Radiation levels for Controlled Environment
                                           Calculated Maximum
                                          Radiation Power Density
Region                                        Level (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 349.1 m)                   Sff         4.435            Satisfies FCC MPE
2. Near Field (Rnf = 145.5 m)                  Snf        10.353             Potential Hazard
3. Transition Region (Rnf < Rt < Rff)          St         10.353             Potential Hazard
4. Between Main Reflector and                  Ssr      1531.647             Potential Hazard
    Subreflector
5. Main Reflector                              Ssurface   16.630             Potential Hazard
6. Between Main Reflector and Ground           Sg          4.158            Satisfies FCC MPE

It is the applicant's responsibility to ensure that the public and operational personnel are not
exposed to harmful levels of radiation.



8.     Conclusions

Based on the above analysis it is concluded that the FCC MPE guidelines have been exceeded (or
met) in the regions of Table 4 and 5. The applicant proposes to comply with the MPE limits by one
or more of the following methods.

Radiation hazard signs will be posted while this earth station is in operation.

Due to the remote and secure location of the proposed earth station antenna at the Brewster
Teleport, the area of operation around the antenna will be limited to those that have knowledge of
the potential for radiation exposure. The applicant will ensure that no buildings or other obstacles
will be in the areas that exceed the MPE levels.


                                                                                       Exhibit
Radiation Hazard Report                                                                Page 5 of 20


Means of Compliance Controlled Areas

The earth station’s operational staff will not have access to the areas that exceed the MPE levels
while the earth station is in operation.

The transmitters will be turned off during antenna maintenance

The applicant agrees to abide by the conditions specified in Condition 5208 provided below:

        Condition 5208 - The licensee shall take all necessary measures to ensure that the
        antenna does not create potential exposure of humans to radiofrequency radiation
        in excess of the FCC exposure limits defined in 47 CFR 1.1307(b) and 1.1310
        wherever such exposures might occur. Measures must be taken to ensure
        compliance with limits for both occupational/controlled exposure and for general
        population/uncontrolled exposure, as defined in these rule sections. Compliance
        can be accomplished in most cases by appropriate restrictions such as fencing.
        Requirements for restrictions can be determined by predictions based on
        calculations, modeling or by field measurements. The FCC's OET Bulletin 65
        (available on-line at www.fcc.gov/oet/rfsafety) provides information on predicting
        exposure levels and on methods for ensuring compliance, including the use of
        warning and alerting signs and protective equipment for worker.


I HEREBY CERTIFY THAT I AM THE TECHNICALLY QUALIFIED PERSON RESPONSIBLE FOR THE
PREPARATION OF THE RADIATION HAZARD REPORT, AND THAT IT IS COMPLETE AND CORRECT
TO THE BEST OF MY KNOWLEDGE AND BELIEF.




BY: _

Gary K. Edwards
Senior Manager
COMSEARCH
19700 Janelia Farm Boulevard
Ashburn, VA 20147


DATED: February 27, 2012


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 6 of 20


      Analysis of Non-Ionizing Radiation for a 3.7-Meter Earth
                          Station System
This report analyzes the non-ionizing radiation levels for a 3.7-meter earth station system. The
analysis and calculations performed in this report comply with the methods described in the FCC
Office of Engineering and Technology Bulletin, No. 65 first published in 1985 and revised in 1997
in Edition 97-01. The radiation safety limits used in the analysis are in conformance with the FCC
R&O 96-326. Bulletin No. 65 and the FCC R&O specifies that there are two separate tiers of
exposure limits that are dependant on the situation in which the exposure takes place and/or the
status of the individuals who are subject to the exposure. The Maximum Permissible Exposure
(MPE) limits for persons in a General Population/Uncontrolled environment are shown in Table 1.
The General Population/Uncontrolled MPE is a function of transmit frequency and is for an
exposure period of thirty minutes or less. The MPE limits for persons in an
Occupational/Controlled environment are shown in Table 2. The Occupational MPE is a function of
transmit frequency and is for an exposure period of six minutes or less. The purpose of the
analysis described in this report is to determine the power flux density levels of the earth station in
the far-field, near-field, transition region, between the subreflector or feed and main reflector
surface, at the main reflector surface, and between the antenna edge and the ground and to
compare these levels to the specified MPEs.

               Table 1. Limits for General Population/Uncontrolled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              0.2
                         300-1500                  Frequency (MHz)*(0.8/1200)
                       1500-100,000                           1.0

                    Table 2. Limits for Occupational/Controlled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              1.0
                         300-1500                  Frequency (MHz)*(4.0/1200)
                       1500-100,000                           5.0

          Table 3. Formulas and Parameters Used for Determining Power Flux Densities
     Parameter                    Symbol           Formula                  Value           Units
     Antenna Diameter                D               Input                   3.7            m
     Antenna Surface Area          Asurface         π D2 / 4                10.75           m2
     Subreflector Diameter          Dsr              Input                   37.0           cm
     Area of Subreflector           Asr             π Dsr 2/4             1075.21           cm2
     Frequency                       F               Input                  14250           MHz
     Wavelength                      λ              300 / F               0.021053          m
     Transmit Power                  P               Input                 400.00           W
     Antenna Gain (dBi)             Ges              Input                   52.7           dBi
     Antenna Gain (factor)           G              10Ges/10              186208.7          n/a
     Pi                              π             Constant              3.1415927          n/a
     Antenna Efficiency              η             Gλ2/(π2D2)                0.61           n/a


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 7 of 20




9.      Far Field Distance Calculation

The distance to the beginning of the far field can be determined from the following equation:

     Distance to the Far Field Region                       Rff = 0.60 D2 / λ                    (1)
                                                                = 390.2 m

The maximum main beam power density in the far field can be determined from the following
equation:

     On-Axis Power Density in the Far Field                 Sff = G P / (4 π Rff 2)              (2)
                                                                = 38.936 W/m2
                                                                = 3.894 mW/cm2

10.     Near Field Calculation

Power flux density is considered to be at a maximum value throughout the entire length of the
defined Near Field region. The region is contained within a cylindrical volume having the same
diameter as the antenna. Past the boundary of the Near Field region, the power density from the
antenna decreases linearly with respect to increasing distance.

The distance to the end of the Near Field can be determined from the following equation:

     Extent of the Near Field                               Rnf = D2 / (4 λ)                     (3)
                                                                = 162.6 m

The maximum power density in the Near Field can be determined from the following equation:

     Near Field Power Density                               Snf = 16.0 η P / (π D2)              (4)
                                                                = 90.894 W/m2
                                                                = 9.089 mW/cm2

11.     Transition Region Calculation

The Transition region is located between the Near and Far Field regions. The power density
begins to decrease linearly with increasing distance in the Transition region. While the power
density decreases inversely with distance in the Transition region, the power density decreases
inversely with the square of the distance in the Far Field region. The maximum power density in
the Transition region will not exceed that calculated for the Near Field region. The power density
calculated in Section 1 is the highest power density the antenna can produce in any of the regions
away from the antenna. The power density at a distance Rt can be determined from the following
equation:

     Transition Region Power Density                        St = Snf Rnf / Rt                    (5)
                                                               = 9.089 mW/cm2


                                                                              Exhibit
Radiation Hazard Report                                                       Page 8 of 20



12.    Region between the Main Reflector and the Subreflector

Transmissions from the feed assembly are directed     toward the subreflector surface, and are
reflected back toward the main reflector. The most    common feed assemblies are waveguide
flanges, horns or subreflectors. The energy between   the subreflector and the reflector surfaces
can be calculated by determining the power density    at the subreflector surface. This can be
determined from the following equation:

   Power Density at the Subreflector                      Ssr = 4000 P / Asr                 (6)
                                                              = 1488.081 mW/cm2

13.    Main Reflector Region

The power density in the main reflector is determined in the same manner as the power density at
the subreflector. The area is now the area of the main reflector aperture and can be determined
from the following equation:

   Power Density at the Main Reflector Surface        Ssurface = 4 P / Asurface              (7)
                                                               = 148.808 W/m2
                                                               = 14.881 mW/cm2


14.    Region between the Main Reflector and the Ground

Assuming uniform illumination of the reflector surface, the power density between the antenna and
the ground can be determined from the following equation:

   Power Density between Reflector and Ground             Sg = P / Asurface                  (8)
                                                             = 37.202 W/m2
                                                             = 3.720 mW/cm2


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 9 of 20



15.    Summary of Calculations

           Table 4. Summary of Expected Radiation levels for Uncontrolled Environment
                                            Calculated Maximum
                                       Radiation Power Density Level
Region                                              (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 390.2 m)                    Sff         3.894             Potential Hazard
2. Near Field (Rnf = 162.6 m)                   Snf         9.089             Potential Hazard
3. Transition Region (Rnf < Rt < Rff)           St          9.089             Potential Hazard
4. Between Main Reflector and                   Ssr      1488.081             Potential Hazard
    Subreflector
5. Main Reflector                               Ssurface   14.881             Potential Hazard
6. Between Main Reflector and Ground            Sg          3.720             Potential Hazard

            Table 5. Summary of Expected Radiation levels for Controlled Environment
                                           Calculated Maximum
                                          Radiation Power Density
Region                                        Level (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 390.2 m)                   Sff         3.894            Satisfies FCC MPE
2. Near Field (Rnf = 162.6 m)                  Snf         9.089             Potential Hazard
3. Transition Region (Rnf < Rt < Rff)          St          9.089             Potential Hazard
4. Between Main Reflector and                  Ssr      1488.081             Potential Hazard
    Subreflector
5. Main Reflector                              Ssurface   14.881             Potential Hazard
6. Between Main Reflector and Ground           Sg          3.720            Satisfies FCC MPE

It is the applicant's responsibility to ensure that the public and operational personnel are not
exposed to harmful levels of radiation.



16.    Conclusions

Based on the above analysis it is concluded that the FCC MPE guidelines have been exceeded (or
met) in the regions of Table 4 and 5. The applicant proposes to comply with the MPE limits by one
or more of the following methods.

Radiation hazard signs will be posted while this earth station is in operation.

Due to the remote and secure location of the proposed earth station antenna at the Brewster
Teleport, the area of operation around the antenna will be limited to those that have knowledge of
the potential for radiation exposure. The applicant will ensure that no buildings or other obstacles
will be in the areas that exceed the MPE levels.


                                                                                       Exhibit
Radiation Hazard Report                                                                Page 10 of 20


Means of Compliance Controlled Areas

The earth station’s operational staff will not have access to the areas that exceed the MPE levels
while the earth station is in operation.

The transmitters will be turned off during antenna maintenance

The applicant agrees to abide by the conditions specified in Condition 5208 provided below:

        Condition 5208 - The licensee shall take all necessary measures to ensure that the
        antenna does not create potential exposure of humans to radiofrequency radiation
        in excess of the FCC exposure limits defined in 47 CFR 1.1307(b) and 1.1310
        wherever such exposures might occur. Measures must be taken to ensure
        compliance with limits for both occupational/controlled exposure and for general
        population/uncontrolled exposure, as defined in these rule sections. Compliance
        can be accomplished in most cases by appropriate restrictions such as fencing.
        Requirements for restrictions can be determined by predictions based on
        calculations, modeling or by field measurements. The FCC's OET Bulletin 65
        (available on-line at www.fcc.gov/oet/rfsafety) provides information on predicting
        exposure levels and on methods for ensuring compliance, including the use of
        warning and alerting signs and protective equipment for worker.


I HEREBY CERTIFY THAT I AM THE TECHNICALLY QUALIFIED PERSON RESPONSIBLE FOR THE
PREPARATION OF THE RADIATION HAZARD REPORT, AND THAT IT IS COMPLETE AND CORRECT
TO THE BEST OF MY KNOWLEDGE AND BELIEF.




BY: _

Gary K. Edwards
Senior Manager
COMSEARCH
19700 Janelia Farm Boulevard
Ashburn, VA 20147


DATED: February 27, 2012


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 11 of 20


      Analysis of Non-Ionizing Radiation for a 6.1-Meter Earth
                          Station System
This report analyzes the non-ionizing radiation levels for a 6.1-meter earth station system. The
analysis and calculations performed in this report comply with the methods described in the FCC
Office of Engineering and Technology Bulletin, No. 65 first published in 1985 and revised in 1997
in Edition 97-01. The radiation safety limits used in the analysis are in conformance with the FCC
R&O 96-326. Bulletin No. 65 and the FCC R&O specifies that there are two separate tiers of
exposure limits that are dependant on the situation in which the exposure takes place and/or the
status of the individuals who are subject to the exposure. The Maximum Permissible Exposure
(MPE) limits for persons in a General Population/Uncontrolled environment are shown in Table 1.
The General Population/Uncontrolled MPE is a function of transmit frequency and is for an
exposure period of thirty minutes or less. The MPE limits for persons in an
Occupational/Controlled environment are shown in Table 2. The Occupational MPE is a function of
transmit frequency and is for an exposure period of six minutes or less. The purpose of the
analysis described in this report is to determine the power flux density levels of the earth station in
the far-field, near-field, transition region, between the subreflector or feed and main reflector
surface, at the main reflector surface, and between the antenna edge and the ground and to
compare these levels to the specified MPEs.

               Table 1. Limits for General Population/Uncontrolled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              0.2
                         300-1500                  Frequency (MHz)*(0.8/1200)
                       1500-100,000                           1.0

                    Table 2. Limits for Occupational/Controlled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              1.0
                         300-1500                  Frequency (MHz)*(4.0/1200)
                       1500-100,000                           5.0

          Table 3. Formulas and Parameters Used for Determining Power Flux Densities
     Parameter                    Symbol           Formula                  Value           Units
     Antenna Diameter                D               Input                   6.1            m
     Antenna Surface Area          Asurface         π D2 / 4                29.22           m2
     Subreflector Diameter          Dsr              Input                   96.5           cm
     Area of Subreflector           Asr             π Dsr 2/4             7313.82           cm2
     Frequency                       F               Input                  14250           MHz
     Wavelength                      λ              300 / F               0.021053          m
     Transmit Power                  P               Input                 750.00           W
     Antenna Gain (dBi)             Ges              Input                   56.9           dBi
     Antenna Gain (factor)           G              10Ges/10              489778.8          n/a
     Pi                              π             Constant              3.1415927          n/a
     Antenna Efficiency              η             Gλ2/(π2D2)                0.59           n/a


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 12 of 20




17.    Far Field Distance Calculation

The distance to the beginning of the far field can be determined from the following equation:

   Distance to the Far Field Region                         Rff = 0.60 D2 / λ                     (1)
                                                                = 1060.5 m

The maximum main beam power density in the far field can be determined from the following
equation:

   On-Axis Power Density in the Far Field                   Sff = G P / (4 π Rff 2)               (2)
                                                                = 25.992 W/m2
                                                                = 2.599 mW/cm2

18.    Near Field Calculation

Power flux density is considered to be at a maximum value throughout the entire length of the
defined Near Field region. The region is contained within a cylindrical volume having the same
diameter as the antenna. Past the boundary of the Near Field region, the power density from the
antenna decreases linearly with respect to increasing distance.

The distance to the end of the Near Field can be determined from the following equation:

   Extent of the Near Field                                 Rnf = D2 / (4 λ)                      (3)
                                                                = 441.9 m

The maximum power density in the Near Field can be determined from the following equation:

   Near Field Power Density                                 Snf = 16.0 η P / (π D2)               (4)
                                                                = 60.677 W/m2
                                                                = 6.068 mW/cm2

19.    Transition Region Calculation

The Transition region is located between the Near and Far Field regions. The power density
begins to decrease linearly with increasing distance in the Transition region. While the power
density decreases inversely with distance in the Transition region, the power density decreases
inversely with the square of the distance in the Far Field region. The maximum power density in
the Transition region will not exceed that calculated for the Near Field region. The power density
calculated in Section 1 is the highest power density the antenna can produce in any of the regions
away from the antenna. The power density at a distance Rt can be determined from the following
equation:

   Transition Region Power Density                          St = Snf Rnf / Rt                     (5)
                                                               = 6.068 mW/cm2


                                                                              Exhibit
Radiation Hazard Report                                                       Page 13 of 20



20.    Region between the Main Reflector and the Subreflector

Transmissions from the feed assembly are directed     toward the subreflector surface, and are
reflected back toward the main reflector. The most    common feed assemblies are waveguide
flanges, horns or subreflectors. The energy between   the subreflector and the reflector surfaces
can be calculated by determining the power density    at the subreflector surface. This can be
determined from the following equation:

   Power Density at the Subreflector                      Ssr = 4000 P / Asr                  (6)
                                                              = 410.182 mW/cm2

21.    Main Reflector Region

The power density in the main reflector is determined in the same manner as the power density at
the subreflector. The area is now the area of the main reflector aperture and can be determined
from the following equation:

   Power Density at the Main Reflector Surface        Ssurface = 4 P / Asurface               (7)
                                                               = 102.653 W/m2
                                                               = 10.265 mW/cm2


22.    Region between the Main Reflector and the Ground

Assuming uniform illumination of the reflector surface, the power density between the antenna and
the ground can be determined from the following equation:

   Power Density between Reflector and Ground             Sg = P / Asurface                   (8)
                                                             = 25.663 W/m2
                                                             = 2.566 mW/cm2


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 14 of 20



23.    Summary of Calculations

           Table 4. Summary of Expected Radiation levels for Uncontrolled Environment
                                            Calculated Maximum
                                       Radiation Power Density Level
Region                                              (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 1060.5 m)                   Sff        2.599              Potential Hazard
2. Near Field (Rnf = 441.9 m)                   Snf        6.068              Potential Hazard
3. Transition Region (Rnf < Rt < Rff)           St         6.068              Potential Hazard
4. Between Main Reflector and                   Ssr      410.182              Potential Hazard
    Subreflector
5. Main Reflector                               Ssurface  10.265              Potential Hazard
6. Between Main Reflector and Ground            Sg         2.566              Potential Hazard

            Table 5. Summary of Expected Radiation levels for Controlled Environment
                                           Calculated Maximum
                                          Radiation Power Density
Region                                        Level (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 1060.5 m)                  Sff         2.599            Satisfies FCC MPE
2. Near Field (Rnf = 441.9 m)                  Snf         6.068             Potential Hazard
3. Transition Region (Rnf < Rt < Rff)          St          6.068             Potential Hazard
4. Between Main Reflector and                  Ssr      410.182              Potential Hazard
    Subreflector
5. Main Reflector                              Ssurface  10.265              Potential Hazard
6. Between Main Reflector and Ground           Sg          2.566            Satisfies FCC MPE

It is the applicant's responsibility to ensure that the public and operational personnel are not
exposed to harmful levels of radiation.



24.    Conclusions

Based on the above analysis it is concluded that the FCC MPE guidelines have been exceeded (or
met) in the regions of Table 4 and 5. The applicant proposes to comply with the MPE limits by one
or more of the following methods.

Radiation hazard signs will be posted while this earth station is in operation.

Due to the remote and secure location of the proposed earth station antenna at the Brewster
Teleport, the area of operation around the antenna will be limited to those that have knowledge of
the potential for radiation exposure. The applicant will ensure that no buildings or other obstacles
will be in the areas that exceed the MPE levels.


                                                                                       Exhibit
Radiation Hazard Report                                                                Page 15 of 20


Means of Compliance Controlled Areas

The earth station’s operational staff will not have access to the areas that exceed the MPE levels
while the earth station is in operation.

The transmitters will be turned off during antenna maintenance

The applicant agrees to abide by the conditions specified in Condition 5208 provided below:

        Condition 5208 - The licensee shall take all necessary measures to ensure that the
        antenna does not create potential exposure of humans to radiofrequency radiation
        in excess of the FCC exposure limits defined in 47 CFR 1.1307(b) and 1.1310
        wherever such exposures might occur. Measures must be taken to ensure
        compliance with limits for both occupational/controlled exposure and for general
        population/uncontrolled exposure, as defined in these rule sections. Compliance
        can be accomplished in most cases by appropriate restrictions such as fencing.
        Requirements for restrictions can be determined by predictions based on
        calculations, modeling or by field measurements. The FCC's OET Bulletin 65
        (available on-line at www.fcc.gov/oet/rfsafety) provides information on predicting
        exposure levels and on methods for ensuring compliance, including the use of
        warning and alerting signs and protective equipment for worker.


I HEREBY CERTIFY THAT I AM THE TECHNICALLY QUALIFIED PERSON RESPONSIBLE FOR THE
PREPARATION OF THE RADIATION HAZARD REPORT, AND THAT IT IS COMPLETE AND CORRECT
TO THE BEST OF MY KNOWLEDGE AND BELIEF.




BY: _

Gary K. Edwards
Senior Manager
COMSEARCH
19700 Janelia Farm Boulevard
Ashburn, VA 20147


DATED: February 27, 2012


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 16 of 20


      Analysis of Non-Ionizing Radiation for a 9.0-Meter Earth
                          Station System
This report analyzes the non-ionizing radiation levels for a 9.0-meter earth station system. The
analysis and calculations performed in this report comply with the methods described in the FCC
Office of Engineering and Technology Bulletin, No. 65 first published in 1985 and revised in 1997
in Edition 97-01. The radiation safety limits used in the analysis are in conformance with the FCC
R&O 96-326. Bulletin No. 65 and the FCC R&O specifies that there are two separate tiers of
exposure limits that are dependant on the situation in which the exposure takes place and/or the
status of the individuals who are subject to the exposure. The Maximum Permissible Exposure
(MPE) limits for persons in a General Population/Uncontrolled environment are shown in Table 1.
The General Population/Uncontrolled MPE is a function of transmit frequency and is for an
exposure period of thirty minutes or less. The MPE limits for persons in an
Occupational/Controlled environment are shown in Table 2. The Occupational MPE is a function of
transmit frequency and is for an exposure period of six minutes or less. The purpose of the
analysis described in this report is to determine the power flux density levels of the earth station in
the far-field, near-field, transition region, between the subreflector or feed and main reflector
surface, at the main reflector surface, and between the antenna edge and the ground and to
compare these levels to the specified MPEs.

               Table 1. Limits for General Population/Uncontrolled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              0.2
                         300-1500                  Frequency (MHz)*(0.8/1200)
                       1500-100,000                           1.0

                    Table 2. Limits for Occupational/Controlled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              1.0
                         300-1500                  Frequency (MHz)*(4.0/1200)
                       1500-100,000                           5.0

          Table 3. Formulas and Parameters Used for Determining Power Flux Densities
     Parameter                    Symbol           Formula                  Value           Units
     Antenna Diameter                D               Input                   9.0            m
     Antenna Surface Area          Asurface         π D2 / 4                63.62           m2
     Subreflector Diameter          Dsr              Input                  116.8           cm
     Area of Subreflector           Asr             π Dsr 2/4             10714.59          cm2
     Frequency                       F               Input                  14250           MHz
     Wavelength                      λ              300 / F               0.021053          m
     Transmit Power                  P               Input                 750.00           W
     Antenna Gain (dBi)             Ges              Input                   60.4           dBi
     Antenna Gain (factor)           G              10Ges/10             1096478.2          n/a
     Pi                              π             Constant              3.1415927          n/a
     Antenna Efficiency              η             Gλ2/(π2D2)                0.61           n/a


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 17 of 20




25.    Far Field Distance Calculation

The distance to the beginning of the far field can be determined from the following equation:

   Distance to the Far Field Region                         Rff = 0.60 D2 / λ                     (1)
                                                                = 2308.5 m

The maximum main beam power density in the far field can be determined from the following
equation:

   On-Axis Power Density in the Far Field                   Sff = G P / (4 π Rff 2)               (2)
                                                                = 12.280 W/m2
                                                                = 1.228 mW/cm2

26.    Near Field Calculation

Power flux density is considered to be at a maximum value throughout the entire length of the
defined Near Field region. The region is contained within a cylindrical volume having the same
diameter as the antenna. Past the boundary of the Near Field region, the power density from the
antenna decreases linearly with respect to increasing distance.

The distance to the end of the Near Field can be determined from the following equation:

   Extent of the Near Field                                 Rnf = D2 / (4 λ)                      (3)
                                                                = 961.9 m

The maximum power density in the Near Field can be determined from the following equation:

   Near Field Power Density                                 Snf = 16.0 η P / (π D2)               (4)
                                                                = 28.666 W/m2
                                                                = 2.867 mW/cm2

27.    Transition Region Calculation

The Transition region is located between the Near and Far Field regions. The power density
begins to decrease linearly with increasing distance in the Transition region. While the power
density decreases inversely with distance in the Transition region, the power density decreases
inversely with the square of the distance in the Far Field region. The maximum power density in
the Transition region will not exceed that calculated for the Near Field region. The power density
calculated in Section 1 is the highest power density the antenna can produce in any of the regions
away from the antenna. The power density at a distance Rt can be determined from the following
equation:

   Transition Region Power Density                          St = Snf Rnf / Rt                     (5)
                                                               = 2.867 mW/cm2


                                                                              Exhibit
Radiation Hazard Report                                                       Page 18 of 20



28.    Region between the Main Reflector and the Subreflector

Transmissions from the feed assembly are directed     toward the subreflector surface, and are
reflected back toward the main reflector. The most    common feed assemblies are waveguide
flanges, horns or subreflectors. The energy between   the subreflector and the reflector surfaces
can be calculated by determining the power density    at the subreflector surface. This can be
determined from the following equation:

   Power Density at the Subreflector                      Ssr = 4000 P / Asr                  (6)
                                                              = 279.992 mW/cm2

29.    Main Reflector Region

The power density in the main reflector is determined in the same manner as the power density at
the subreflector. The area is now the area of the main reflector aperture and can be determined
from the following equation:

   Power Density at the Main Reflector Surface        Ssurface = 4 P / Asurface               (7)
                                                               = 47.157 W/m2
                                                               = 4.716 mW/cm2


30.    Region between the Main Reflector and the Ground

Assuming uniform illumination of the reflector surface, the power density between the antenna and
the ground can be determined from the following equation:

   Power Density between Reflector and Ground             Sg = P / Asurface                   (8)
                                                             = 11.789 W/m2
                                                             = 1.179 mW/cm2


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 19 of 20



31.    Summary of Calculations

           Table 4. Summary of Expected Radiation levels for Uncontrolled Environment
                                            Calculated Maximum
                                       Radiation Power Density Level
Region                                              (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 2308.5 m)                   Sff        1.228              Potential Hazard
2. Near Field (Rnf = 961.9 m)                   Snf        2.867              Potential Hazard
3. Transition Region (Rnf < Rt < Rff)           St         2.867              Potential Hazard
4. Between Main Reflector and                   Ssr      279.992              Potential Hazard
    Subreflector
5. Main Reflector                               Ssurface   4.716              Potential Hazard
6. Between Main Reflector and Ground            Sg         1.179              Potential Hazard

            Table 5. Summary of Expected Radiation levels for Controlled Environment
                                           Calculated Maximum
                                          Radiation Power Density
Region                                        Level (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 2308.5 m)                  Sff         1.228            Satisfies FCC MPE
2. Near Field (Rnf = 961.9 m)                  Snf         2.867            Satisfies FCC MPE
3. Transition Region (Rnf < Rt < Rff)          St          2.867            Satisfies FCC MPE
4. Between Main Reflector and                  Ssr      279.992              Potential Hazard
    Subreflector
5. Main Reflector                              Ssurface    4.716            Satisfies FCC MPE
6. Between Main Reflector and Ground           Sg          1.179            Satisfies FCC MPE

It is the applicant's responsibility to ensure that the public and operational personnel are not
exposed to harmful levels of radiation.



32.    Conclusions

Based on the above analysis it is concluded that the FCC MPE guidelines have been exceeded (or
met) in the regions of Table 4 and 5. The applicant proposes to comply with the MPE limits by one
or more of the following methods.

Radiation hazard signs will be posted while this earth station is in operation.

Due to the remote and secure location of the proposed earth station antenna at the Brewster
Teleport, the area of operation around the antenna will be limited to those that have knowledge of
the potential for radiation exposure. The applicant will ensure that no buildings or other obstacles
will be in the areas that exceed the MPE levels.


                                                                                       Exhibit
Radiation Hazard Report                                                                Page 20 of 20


Means of Compliance Controlled Areas

The earth station’s operational staff will not have access to the areas that exceed the MPE levels
while the earth station is in operation.

The transmitters will be turned off during antenna maintenance

The applicant agrees to abide by the conditions specified in Condition 5208 provided below:

        Condition 5208 - The licensee shall take all necessary measures to ensure that the
        antenna does not create potential exposure of humans to radiofrequency radiation
        in excess of the FCC exposure limits defined in 47 CFR 1.1307(b) and 1.1310
        wherever such exposures might occur. Measures must be taken to ensure
        compliance with limits for both occupational/controlled exposure and for general
        population/uncontrolled exposure, as defined in these rule sections. Compliance
        can be accomplished in most cases by appropriate restrictions such as fencing.
        Requirements for restrictions can be determined by predictions based on
        calculations, modeling or by field measurements. The FCC's OET Bulletin 65
        (available on-line at www.fcc.gov/oet/rfsafety) provides information on predicting
        exposure levels and on methods for ensuring compliance, including the use of
        warning and alerting signs and protective equipment for worker.


I HEREBY CERTIFY THAT I AM THE TECHNICALLY QUALIFIED PERSON RESPONSIBLE FOR THE
PREPARATION OF THE RADIATION HAZARD REPORT, AND THAT IT IS COMPLETE AND CORRECT
TO THE BEST OF MY KNOWLEDGE AND BELIEF.




BY: _

Gary K. Edwards
Senior Manager
COMSEARCH