Attachment RF RADIATION HAZARD

This document pretains to SES-LIC-20110908-01041 for License on a Satellite Earth Station filing.

IBFS_SESLIC2011090801041_915545

                     RF RADIATION HAZARD ANALYSIS
                                Exhibit #B

Antenna Dia. (D)=1.4 Meters 4.593 Feet
Antenna Surface Area (SA)=1.5392 sq meters
Subreflector Dia. (DS)=N/A (prime focus offset)
Subreflector Surface Area (AS)=N/A (prime focus offset)
KU Wavelength at 14.250 GHz (LAMBDA)=.0211 meters
Power at output of HPA flange=21.763dB
Path Loss to OMT (IL)=.2 dB
Power at OMT Flange (P)=146.083 watts (21.646dB)
Antenna Gain at 14.250 GHz (G)=45.9 dBi
Antenna Gain given in Power Ratio (GES)=.4067E+04
Antenna Aperture Efficiency (N)=.6191

Region                                Radiation Level         Hazard Assessment
Far Field (RF) 92.133 m 302.287 ft    21.769 mW/cm sq         Potential Hazard
Near Field (WF) 38.389 m 125.95 ft    50.59 mW/cm sq          Potential Hazard
Transition Region (RT)                equal to or less than   Potential Hazard
    Ru<Rt<Rf                          50.59 mW/cm sq
Between Main Reflector and            N/A
    Subreflector (WS)
Main Reflector Region (WM)            40.858 mW/cm sq         Potential Hazard
Power Density Between Reflector       20.429 mW/cm sq         Potential Hazard
    and Ground

Conclusion: Based on the above analysis, harmful areas of Radiation do exist in areas
around the antenna and in the path of the antenna toward the satellite that it is pointed at.
The Area occupied by the general public will not exceed the ANSI limit of 1 mW cm sq.
because the antenna is mounted at least 6 feet above the ground, and safety increases with
look angles used by the Satellites in the United States on Domestic Satellite arc. The
Antenna will be marked with the standard radiation hazard warnings. The warning signs
will warn personnel to avoid the area around and in front of the reflector when the
transmitter is operating. To ensure compliance with safety limits, the earth station
transmitter will be turned off and marked to remain off whenever maintenance and repair
personnel are required to work in the areas of potential hazard as defined in the above
study. Additionally the earth station personnel will be trained to insure that the antenna
path is clear at all times while the transmitter is in operation