                                          SCHLUMBERGER TECHNOLOGY CORPORATION
                                                                   Q. 28, Form 312
                                                                        Page 1 of 4

                                           EXHIBIT 1


                              Analysis of Non-Ionizing Radiation
                             For a 2.4 Meter Earth Station System

This report analyzes the non-ionizing radiation levels for a 2.4 meter earth station system. The
analysis and calculations performed in this report are in compliance with the methods described
in the FCC Office of Engineering and Technology Bulletin, No. 65, first published in 1985 and
revised in 1997 in Edition 97-01. The radiation safety limits used in the analysis are in
conformance with FCC R&O 96-326. Bulletin No. 65 and FCC R&O 96-236 each specifies that
there are two (2) separate tiers of exposure limits that are dependent on the situation in which the
exposure takes place and/or the status of the individuals who are subject to the exposure. The
Maximum Permissible Exposure (“MPE”) limits for persons in a General
Population/Uncontrolled Environment are shown in Table 1 below. The General Population/
Uncontrolled MPE is a function of transmit frequency and is for an exposure period of 30
minutes or less. The MPE limits for persons in an Occupational/Controlled environment are
shown in Table 2 below. The Occupational MPE is a function of transmit frequency and is for
an exposure period of six (6) minutes or less. The purpose of the analysis described in this report
is to determine the power flux density levels of the earth station in the far-field, near-field,
transition region, between the subreflector or feed and main reflector surface, at the main
reflector surface, and between the antenna edge and the ground and to compare these levels to
the specified MPEs.


Table 1. Limits for General Population/Uncontrolled Exposure (MPE)
 Frequency Range (MHZ)                Power Density (mWatts/cm**2)

               30-300                              0.2
              300-1500                    Frequency ((MHZ) *(0.8/1200)
            1500 – 100,000                         1.0

Table 2. Limits for Occupational/Controlled Exposure (MPE)
 Frequency Range (MHZ)                Power Density (mWatts/cm**2)

               30-300                              1.0
              300-1500                    Frequency (MHZ) *(4.0/1200)
            1500 – 100,000                         5.0

Table 3 contains the parameters that are used to calculate the various power densities for the
earth stations.


                                         SCHLUMBERGER TECHNOLOGY CORPORATION
                                                                  Q. 28, Form 312
                                                                       Page 2 of 4

Table 3. Formulas and Parameters Used for Determining Power Flux Densities
Parameter                Abbreviation              Value                 Units
Antenna Diameter              D                      2.4                meters
Antenna Surface Area          Sa                II * D**2/4           meters**2
Subreflector Diameter        Ds                      19.0                 cm
Area of Subreflector         As                II * Ds**2/4             cm**2
Frequency                 Frequency                 6000                 MH Z
Wavelength                 lambda          300/frequency (MHZ)          meters
Transmit Power                P                     50.00                Watts
Antenna Gain                 Ges                     49.0                 dBi
Pi                            II                 3.1415927                n/a
Antenna Efficiency            n                     0.62                  n/a

1.     Far Field Distance Calculation

The distance to the beginning of the far field can be determined from the following equation: (1)

      Distance to the Far Field Region, (Rf) =      0.60 * D**2 / lambda                  (1)
                                             =      164.2 meters

The maximum main beam power density in the Far Field can be determined from the following
equation: (2)

      On-Axis Power Density in the Far Field, (Wf) =        Ges * P / 4 * II * / Rf**2    (2)
                                                   =        3.771 Watts/meters**2
                                                   =        0.377 mWatts/cm**2

2.     Near Field Calculation

Power flux density is considered to be at a maximum value throughout the entire length of the
defined Near Field region. The region is contained within a cylindrical volume having the same
diameter as the antenna. Past the boundary of the Near Field region, the power density from the
antenna decreases linearly with respect to increasing distance.

The distance to the end of the Near Field can be determined from the following equation: (3)

      Extent of the Near Field, (Rn) = D**2 / (4 * lambda)                                (3)
                                     = 68.4. meters

The maximum power density in the Near Field can be determined from the following equation:
(4)

      Near Field Power Density, (Wn) = 16.0 * n * P / II * D**2                           (4)
                                     = 27.41 Watts/meters**2
                                     = 2.741 mWatts/cm**2


                                        SCHLUMBERGER TECHNOLOGY CORPORATION
                                                                 Q. 28, Form 312
                                                                      Page 3 of 4


3.     Transition Region Calculations

The Transition region is located between the Near and Far Field regions. As stated in Section 2
above, the power density begins to decrease linearly with increasing distance in the Transition
region. While the power density decreases inversely with distance in the Transition region, the
power density decreases inversely with the square of the distance in the Far Field region. The
maximum power density in the Transition region will not exceed that calculated for the Near
Field region. The power density calculated in Section 1 above is the highest power density that
the antenna can produce in any of the regions away from the antenna. The power density at a
distance Rt can be determined from the following equation: (5)

      Transition region Power Density, (Tt) = Wn * Rn / Rt                               (5)

4.     Region between Main Reflector and Subreflector

Transmissions from the feed assembly are directed toward the subreflector surface and are
reflected back toward the main reflector. The most common feed assemblies are waveguide
flanges, horns or subreflectors. The energy between the subreflector and the reflector surfaces
can be calculated by determining the power density at the subreflector surface. This calculation
can be determined from the following equation: (6)

       Power Density at Feed Flange, (Ws) = 4 * P / As                                   (6)
                                          = 44.2 mWatts/cm**2

5.     Main Reflector Region

The power density in the main reflector is determined in the same manner as the power density at
the subreflector, in Section 4 above, but the area is now the area of the main reflector aperture
and can be determined from the following equation: (7)

       Power Density at the Main Reflector Surface, (Wm) = 4 * P / Sa                    (7)
                                                      = 14.147 Watts/meters**2
                                                      = 1.415 mWatts/cm**2

6.     Region between Main Reflector and Ground

Assuming uniform illumination of the reflector surface, the power density between the antenna
and ground can be determined from the following equation: (8)

       Power Density between Reflector and Ground, (Wg) = P / Sa                         (8)
                                                    = 3.537 Watts/meters**2
                                                    = 0.354 mWatts/cm**2


                                     SCHLUMBERGER TECHNOLOGY CORPORATION
                                                              Q. 28, Form 312
                                                                   Page 4 of 4

Table 4. Summary of Expected Radiation levels for Uncontrolled Environment
                            Calculated Maximum          Radiation
 Region                      Power Density Level    (mWatts/cm**2) Hazard Assessment
 1. Far Field (Rf)             = 164.2 meters            0.377        Satisfies FCC MPE
 2. Near Field (Rn)              = 68.4 meters            2.741        Satisfies FCC MPE
 3. Transition Region                                     2.741
    Rn <Rt < Rf, (Rt)
                                                                       Satisfies FCC MPE
 4. Between Main Reflector                                 44.2         Potential Hazard
    and Subreflector

 5. Main Reflector                                        1.415         Potential Hazard
 6. Between Main Reflector                                0.354        Satisfies FCC MPE
    and Ground

Table 5. Summary of Expected Radiation levels for Controlled Environment
                           Calculated Maximum           Radiation
 Region                    Power Density Level      (mWatts/cm**2) Hazard Assessment
 1. Far Field (Rf)             = 164.2 meters             0.377      Satisfies FCC MPE
 2. Near Field (Rn)               = 68.4meters            2.741        Satisfies FCC MPE
 3. Transition Region
    Rn < Rt, < Rf, (Rt)
                                                          2.741        Satisfies FCC MPE
 4. Between Main Reflector                                 44.1         Potential Hazard
    and Subreflector

 5. Main Reflector                                        1.415        Satisfies FCC MPE
 6. Between Main Reflector                                0.354        Satisfies FCC MPE
    and Ground

It is the responsibility of Schlumberger Technology Corporation to ensure that public and
operational personnel are not exposed to harmful levels of radiation.