Attachment radhadE960138

This document pretains to SES-LIC-20070205-00190 for License on a Satellite Earth Station filing.

IBFS_SESLIC2007020500190_550647

                                 Radiation Hazard Analysis
                                 IIlinois Bible Institute, Inc.
                                      Call Sign E960138
                                      February 15, 2007


Earth Station Technical Parameter Table
Antenna Actual Diameter                                  2.4 meters
Antenna Surface Area                                     4.5 sq. meters
Antenna Isotropic Gain                                   49.2 dBi
Number of Identical Adjacent Antennas*                   1
Nominal Antenna Efficiency (ε)                           63%
Nominal Frequency                                        14500 MHz
Nominal Wavelength (λ)                                   0.0207 meters
Maximum Transmit Power / Carrier                         2 Watts
Number of Carriers                                       1
Total Transmit Power                                     2 Watts
W/G Loss from Transmitter to Feed                        0 dB
Total Feed Input Power                                   2 Watts
Near Field Limit                                         Rnf = D²/4λ = 70 meters
Far Field Limit                                          Rff = 0.6 D²/λ = 167 meters
Transition Region                                        Rnf to Rff


* The Radiation Levels will be increased directly by the number of antennas indicated, on the
assumption that all antennas may illuminate the same area.

In the following sections, the power density in the above regions, as well as other critically
important areas will be calculated and evaluated. The calculations are done in the order discussed in
OET Bulletin 65. In addition to the input parameters above, input cells are provided below for the
user to evaluate the power density at specific distances or angles.

This analysis predicts the radiation levels around a proposed earth station complex, comprised of
one or more aperture (reflector) type antennas. This report is developed in accordance with the
prediction methods contained in OET Bulletin No. 65, Evaluating Compliance with FCC Guidelines for
Human Exposure to Radio Frequency Electromagnetic Fields, Edition 97-01, pp 26-30. The
maximum level of non-ionizing radiation to which employees may be exposed is limited to a power
density level of 5 milliwatts per square centimeter (5 mW/cm2) averaged over any 6 minute period
in a controlled environment and the maximum level of non-ionizing radiation to which the
general public is exposed is limited to a power density level of 1 milli watt per square centimeter (1
mW/cm2) averaged over any 30 minute period in a uncontrolled environment. Note that the
worse-case radiation hazards exist along the beam axis. Under normal circumstances, it is highly
unlikely that the antenna axis will be aligned with any occupied area since that would represent a
blockage to the desired signals, thus rendering the link unuseable.




IIlinois Bible Institute, Inc.                    1
Call Sign E960138
February 15, 2007


1.0 At the Antenna Surface

The power density at the reflector surface can be calculated from the expression:


  PDrefl =    4P/A =             0.18 mW/cm²               (1)
  Where:      P = total power at feed, milliwatts
              A = Total area of reflector, sq. cm


In the normal range of transmit powers for satellite antennas, the power densities at or around the
reflector surface is expected to exceed safe levels. This area will not be accessible to the general
public. Operators and technicians will receive training specifying this area as a high exposure area.
Procedures will be established that will assure that all transmitters are rerouted or turned off before
access by maintenance personnel to this area is possible.

2.0 On-Axis Near Field Region

The geometrical limits of the radiated power in the near field approximate a cylindrical volume with
a diameter equal to that of the antenna. In the near field, the power density is neither uniform nor
does its value vary uniformly with distance from the antenna. For the purpose of considering
radiation hazard it is assumed that the on-axis flux density is at its maximum value throughout the
length of this region. The length of this region, i.e., the distance from the antenna to the end of the
near field, is computed as Rnf above.

The maximum power density in the near field is given by:


  PDnf = (16ε P)/(π D²) =                        0.11 mW/cm² (2)
                                                 from 0 to 70 meters
Evaluation
  Uncontrolled Environment:                      Complies to FCC Limits
  Controlled Environment:                        Complies to FCC Limits


3.0 On-Axis Transition Region

The transition region is located between the near and far field regions. As stated in Bulletin 65, the
power density begins to vary inversely with distance in the transition region. The maximum power
density in the transition region will not exceed that calculated for the near field region, and the
transition region begins at that value. The maximum value for a given distance within the transition
region may be computed for the point of interest according to:


  PDt =              (PDnf)(Rnf)/R = dependent on R (3)
  where:             PDnf = near field power density
                     Rnf = near field distance
                     R = distance to point of interest
  For:               70 < R < 167 meters


We use Eq (3) to determine the safe on-axis distances required for the two occupancy conditions:

Evaluation


 Uncontrolled Environment Safe Operating Distance,(meters), Rsafeu:       8




IIlinois Bible Institute, Inc.                         2
Call Sign E960138
February 15, 2007


 Controlled Environment Safe Operating Distance,(meters), Rsafec:         2


4.0 On-Axis Far-Field Region

The on- axis power density in the far field region (PDff) varies inversely with the square of the
distance as follows:


 PDff =   PG/(4πR²) = dependent on R (4)
 where: P = total power at feed
          G = Numeric Antenna gain in the direction of interest relative to isotropic radiator
          R = distance to the point of interest
 For:     R > Rff = 167 meters
          PDff = 0.05 mW/cm² at Rff


We use Eq (4) to determine the safe on-axis distances required for the two occupancy conditions:

Evaluation


 Uncontrolled Environment Safe Operating Distance,(meters), Rsafeu :      See Section 3
 Controlled Environment Safe Operating Distance,(meters), Rsafec :        See Section 3


5.0 Off-Axis Levels at the Far Field Limit and Beyond

Ip the far field region, the power is distributed in a pattern of maxima and minima (sidelobes) as a
function of the off-axis angle between the antenna center line and the point of interest. Off-axis
power density in the far field can be estimated using the antenna radiation patterns prescribed for
the antenna in use. Usually this will correspond to the antenna gain pattern envelope defined by the
FCC or the ITU, which takes the form of:


  Goff = 32 - 25log(Θ)
  for Θ from 1 to 48 degrees; -10 dBi from 48 to 180 degrees
  (Applicable for commonly used satellite transmit antennas)


Considering that satellite antenna beams are aimed skyward, power density in the far field will
usually not be a problem except at low look angles. In these cases, the off axis gain reduction may
be used to further reduce the power density levels.

For example: At one (1) degree off axis At the far-field limit, we can calculate the power density as:

Goff = 32 - 25log(1) = 32 - 0 dBi = 1585 numeric


 PD1 deg off-axis = PDffx 1585/G = 0.0009 mW/cm² (5)




IIlinois Bible Institute, Inc.                     3
Call Sign E960138
February 15, 2007


6.0 Off-Axis power density in the Near Field and Transitional Regions

According to Bulletin 65, off-axis calculations in the near field may be performed as follows:
assuming that the point of interest is at least one antenna diameter removed from the center of the
main beam, the power density at that point is at least a factor of 100 (20 dB) less than the value
calculated for the equivalent on-axis power density in the main beam. Therefore, for regions at least
D meters away from the center line of the dish, whether behind, below, or in front under of the
antenna's main beam, the power density exposure is at least 20 dB below the main beam level as
follows:


 PDnf(off-axis) = PDnf /100 = 0.001 mW/cm² at D off axis (6)


7.0 Region Between the Feed Horn and Sub-reflector

Transmissions from the feed horn are directed toward the subreflector surface, and are confined
within a conical shape defined by the feed horn. The energy between the feed horn and subreflector
is conceded to be in excess of any limits for maximum permissible exposure. This area will not be
accessible to the general public. Operators and technicians should receive training specifying this
area as a high exposure area. Procedures must be established that will assure that all transmitters
are rerouted or turned off before access by maintenance personnel to this area is possible.

Note 1:
Mitigation of the radiation level may take several forms. First, check the distance from the antenna
to the nearest potentially occupied area that the antenna could be pointed toward, and compare to
the distances appearing in Sections 2, 3 & 4. If those distances lie within the potentially hazardous
regions, then the most common solution would be to take steps to insure that the antenna(s) are
not capable of being pointed at those areas while RF is being transmitted. This may be
accomplished by setting the tracking system to not allow the antenna be pointed below certain
elevation angles. Other techniques, such as shielding may also be used effectively.

Evaluation of Safe Occupancy Area in Front of Antenna

The distance (S) from a vertical axis passing through the dish center to a safe off axis location in
front of the antenna can be determined based on the dish diameter rule (Item 6.0). Assuming a flat
terrain in front of the antenna, the relationship is:




For distances equal or greater than determined by equation (7), the radiation hazard will be below
safe levels for all but the most powerful stations (> 4 kilowatts RF at the feed).




IIlinois Bible Institute, Inc.                    4
Call Sign E960138
February 15, 2007


CONCLUSION

In the normal range of transmit powers for satellite antennas, the power densities at or around the
reflector surface is expected to exceed safe levels. Therefore a fence will be provided to prevent
casual occupancy of the area in front of the antenna within limits prescribe above at the lowest
elevation angle required. Operators and technicians will receive training specifying this area as a
high exposure area. Procedures will be established that will assure that all transmitters are rerouted
or turned off before access by maintenance personnel to this area is possible.




IIlinois Bible Institute, Inc.                    5
Call Sign E960138
February 15, 2007



Document Created: 2007-02-16 12:05:32