Attachment RADIATION HAZ ANALYS

This document pretains to SES-LIC-20061114-02000 for License on a Satellite Earth Station filing.

IBFS_SESLIC2006111402000_535284

                       RADIATION HAZARD ANALYSIS
                        EARTH STATION ANTENNA


           In accordance with "Evaluation compliance with FCC Guidelines for
Human Exposure to Radiofrequency Electromagnetic Fields," F.C.C. Office of
Engineering and Technology OET Bulletin 65, edition 97-01, released August,
1997, the operation of the earth station will be in compliance with government
standards prescribed to protect employees and the public from exposure to
excessive levels of non-ionizing radiations as required by 47 C.F.R. Ch. I,
Section 1.1307(b). Supporting calculations demonstrate that the earth station will
not expose workers nor the public with radio frequency radiation in excess of
MPE found in OET Bulletin 56, 4th edition, released August, 1999.

Radiation Hazard and Power Density Calculations as follows:


       This analysis calculates the non-ionizing radiation levels due to
transmission from the earth station. The maximum level of non-ionizing radiation
to which a person may be exposed corresponds to a power density of 50
Watts/meter2 (or 5mW/cm.2) averaged over any six minute period for confined
areas and a power density of 10 Watts/meter2 (or 1 mW/cm.2) averaged over
any thirty minute period for non-confined areas, as derived from OET Bulletin 65,
edition 97-01. These are based on MPE limits found in Section 4.1 of , "IEEE
Standard for Safety Levels with Respect to Human Exposure to Radio Frequency
Electromagnetic Fields, 3 kHz to 300 GHz," ANSI/IEEE C95.1-1992, Copyright
1992 by the Institute of Electrical and Electronics Engineers, Inc., New York, New
York 10017, and approved for use as an American National Standard by the
American National Standards Institute (ANSI).
.

           The analysis estimates the maximum power density levels in the vicinity
of the antenna for six regions: near field; transition zone; near the reflector
surface; between the reflector and the ground; and between the feed mouth and
reflector.

        A brief discussion for each region is given below. The attached table
shows the assumptions, formulas and calculations for all cases.




                                       -1-


          1.    Near Field Region

           The near field (for Fresnel region) is essentially a cylindrical region with
its axis co-incident with the antenna boresight. The diameter of this cylinder is
equal to that of the antenna. According to OET Bulletin No. 65, its length is equal
to the square of the diameter divided by four times the wavelength. The
maximum value of the on-axis power density is calculated using the equation
given in the bulletin.

          2.    Far Field Region

           The far field (or Fraunhofer region) extends outwards from a distance
equal to 0.6 times the square of the reflector diameter divided by the wavelength,
according to OET Bulletin No. 65. Power density varies inversely as the square
of the distance. The maximum value of the power density is calculated using the
equation given in the bulletin.


          3.    Transmission Region

          The transmission region between the near field and the far field regions
will have a power density that essentially decreases inversely as distance. In any
case, the maximum power density will not exceed the maximum value calculated
for the near field region, for the purpose of evaluating potential exposure.

         4.    Region Near Reflector Surface

          The power density in the region near the reflector surface can be estimated
as equal to twice the power divided by the area of the reflector surface, assuming that
the illumination is uniform and that it would be possible to intercept equal amounts of
energy radiated towards and reflected from the reflector surface.

         5.    Region between Reflector and Ground

         The power density in the region between the reflector and the ground can be
estimated as equal to the power divided by the area of the reflector surface,
assuming even illumination over the reflector.

         6.    Region Between the Feed Mouth and Reflector

          The radiation from the feed is essentially confined to a conical region whose
vertex is located at the feed mouth and extends to the reflector. Power density is
maximum at the feed mouth, and can be estimated as twice the output power divided
by the area of the feed mouth.


                                          -2-


          The analysis shows that the power density levels will never exceed the ANSI
limit even during periods of maximum output, except in the region between the feed
and the reflector. To ensure compliance with the ANSI limit, the earth station
transmitter will be turned off whenever maintenance and repair personnel are
required to work near this potentially hazardous area.


                         RADIATION HAZARD CALCULATIONS FOR
                           FIXED 3.7 METER EARTH STATION


Nomenclature                                              Value Unit

INPUT PARAMETERS

D = Antenna Diameter                                      3.7 Meters

d = Feed Mouth Diameter                                   0.127 Meters

P = Max power into Antenna                                350.0 Watts

n = Apperture Efficiency                                  0.8 (80% worse case)

k = Wavelength @ 14.5 GHz.                                0.0211 Meters




CALCULATED VALUES                           FORMULA

A = Area of reflector                       [(pi)D2]/4    10.752 Meters2

l = Length of near field                    [D2]/4k       162.204 Meters

L = Start of far field                      [0.6D2]/k     389.29 Meters

G = Gain of Antenna @ 14.5 GHz            n[(pi)(D)/k]2   242,789 (@52.8 dBi)
  n=.8 for worst case

a = Area of feed mouth                      [(pi)(d)2]/4 0.0127 Meters2




                                            -3-


                        RADIATION HAZARD CALCULATIONS FOR
                         FIXED 3.7 METER EARTH STATION


        POWER DENSITY CALCULATIONS for 350 watts into antenna
          WORSE CASE ASSESSMENT

                                                               Hazard Assessment
Region         Formula                 Value W/m2              ANSI Limit=50 W/m2

1 Surface        4P/A                130.2 @ ant surface          Potential Hazard

2 Transition Surf to Nr Fld          130.2 to 416.7               Potential Hazard

3 Near Field 16nP/A                  416.7 @ 162.2meters          Potential Hazard

4 Transition Nr Fld to Far           416.7 to 44.6                Potential Hazard

5 Far Field    GP/[4(pi)L2]          44.6 @ 389.3meters           Potential Hazard

6 Between
 Subref-feed 2P/a                    55,118.1                     Potential Hazard



The length of the cone (cylinder) of danger (Clear Zone Length to reduce energy by 20 dB) will be:
   X = H/tan(El)
   where      X = Clear Zone length all directions
          H = Height of Human Life Form (2 meters) plus 3.7 meters (ant diameter)
          El= Antenna elevation (10 degrees absolute minimum)
   X = (5.7)/tan(10) = 33 meters worst case.



Declaration: Public protection from antenna.
This Temporary-Fixed antenna will be protected from human access as it is
to be installed at a limited access location within a confined parking area
available only to personnel associated with business commerce. The exact
location places the antenna next to a chain-link fence and associated
building wall where there is no human traffic. The front and other sides of
the antenna is beyond the reach of human personnel and guarded by a
construction fence. Antenna access is restricted, locked and available only
to authorized personnel. Thus, the antenna location will conform to defined
standards. (OET Bulletin 65, Ed. 97-01, August 1997 and OET Bulletin 56, 4th
ed. August 1999).



                                                   -4-



Document Created: 2006-11-15 08:40:01
Document Modified: 2006-11-15 08:40:01

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC