User Manual rev1

FCC ID: QISARDCM-1PHT

Users Manual

Download: PDF
FCCID_3178314

ARDCM-1PHT Three-Phase PLC Module
User Manual


Issue     01

Date      2016-10-10




HUAWEI TECHNOLOGIES CO., LTD.


Copyright © Huawei Technologies Co., Ltd. 2016. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.


Trademarks and Permissions

       and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.


Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.




Huawei Technologies Co., Ltd.
Address:     Huawei Industrial Base
             Bantian, Longgang
             Shenzhen 518129
             People's Republic of China

Website:     http://e.huawei.com




Issue 01 (2016-10-10)                 Huawei Proprietary and Confidential                               i
                                   Copyright © Huawei Technologies Co., Ltd.


ARDCM-1PHT Three-Phase PLC Module
User Manual                                                                                 About This Document




                                                            About This Document

Purpose
                   This document describes the technical specifications, functions, and installation methods of
                   the ARDCM-1PHT three-phase PLC module.



Intended Audience
                   This document is intended for:
                        Technical support engineers
                        Maintenance engineers



Symbol Conventions
                   The symbols that may be found in this document are defined as follows.

                     Symbol                      Description
                                                 Indicates an imminently hazardous situation which, if not
                                                 avoided, will result in death or serious injury.

                                                 Indicates a potentially hazardous situation which, if not
                                                 avoided, could result in death or serious injury.

                                                 Indicates a potentially hazardous situation which, if not
                                                 avoided, may result in minor or moderate injury.

                                                 Indicates a potentially hazardous situation which, if not
                                                 avoided, could result in equipment damage, data loss,
                                                 performance deterioration, or unanticipated results.
                                                 NOTICE is used to address practices not related to personal
                                                 injury.
                                                 Calls attention to important information, best practices and
                                                 tips.
                                                 NOTE is used to address information not related to personal
                                                 injury, equipment damage, and environment deterioration.



 Issue 01 (2016-10-10)                Huawei Proprietary and Confidential                                         ii
                                   Copyright © Huawei Technologies Co., Ltd.


ARDCM-1PHT Three-Phase PLC Module
User Manual                                                                             About This Document


Change History
                   Changes between document issues are cumulative. The latest document issue contains all the
                   changes made in earlier issues.

Issue 01 (2016-10-10)
                   This is the first official release.




 Issue 01 (2016-10-10)                  Huawei Proprietary and Confidential                                iii
                                     Copyright © Huawei Technologies Co., Ltd.


ARDCM-1PHT Three-Phase PLC Module
User Manual                                                                                                                                                            Contents




                                                                                                                                                   Contents

About This Document .................................................................................................................... ii
1 Product Overview ......................................................................................................................... 5
1.1 Application Scenarios ................................................................................................................................................... 5
1.2 Functions ...................................................................................................................................................................... 5
1.3 Appearance ................................................................................................................................................................... 6
1.4 Technical Specifications ............................................................................................................................................... 6

2 Installation Guide ......................................................................................................................... 8
2.1 Packing List .................................................................................................................................................................. 8
2.2 Installation Instructions................................................................................................................................................. 8
2.2.1 Installation Procedure ................................................................................................................................................ 8
2.3 Module Replacement .................................................................................................................................................... 9




  Issue 01 (2016-10-10)                                      Huawei Proprietary and Confidential                                                                                 iv
                                                          Copyright © Huawei Technologies Co., Ltd.


ARDCM-1PHT Three-Phase PLC Module
User Manual                                                                                   1 Product Overview




                                                         1            Product Overview

1.1 Application Scenarios
                  The ARDCM-1PHT is the ARDCM’s terminal communication module that is used on a meter
                  to collect data and send collected data to the ARDCM. This module uses power line
                  communication (PLC) technology to upload and download data, implementing remote
                  wireless control.
                  It is used for intelligent meter reading and applicable to various scenarios that use smart meter
                  systems, such as smart household and smart building.



1.2 Functions
                  The ARDCM-1PHT module provides the following functions:
                       Uses PLC technology to upload information.
                       Enables remote meter reading, which is convenient and time-saving.




Issue 01 (2016-10-10)                Huawei Proprietary and Confidential                                         5
                                  Copyright © Huawei Technologies Co., Ltd.


ARDCM-1PHT Three-Phase PLC Module
User Manual                                                                               1 Product Overview


1.3 Appearance
                  Figure 1-1 ARDCM-1PHT appearance




1.4 Technical Specifications
                  Table 1-1 ARDCM-1PHT technical specifications

                    Item                        Description
                    Communication method        PLC
                    Working frequency           2-12 MHz
                    External interfaces         High-voltage interface (three-phase meter connector
                                                2)
                                                Low-voltage interface (three-phase meter connector
                                                1)
                    Operating temperature       Long-term operating temperature: -40°C to +70°C
                                                (-40°F to +158°F)
                    Altitude                    0-4000 m (0-13123 ft.)
                    Storage temperature         -40°C to +85°C (-40°F to +185°F)
                    Power consumption           < 12 W
                    Dimensions (W x D x H)      89 mm x 59 mm x 12 mm (3.50 in. x 2.32 in. x 0.47
                                                in.)




Issue 01 (2016-10-10)                 Huawei Proprietary and Confidential                                  6
                                   Copyright © Huawei Technologies Co., Ltd.


ARDCM-1PHT Three-Phase PLC Module
User Manual                                                              1 Product Overview


                    Item                  Description
                    Weight                76.7 g (0.17 lb)




Issue 01 (2016-10-10)           Huawei Proprietary and Confidential                       7
                             Copyright © Huawei Technologies Co., Ltd.


ARDCM-1PHT Three-Phase PLC Module
User Manual                                                                               2 Installation Guide




                                                       2           Installation Guide

2.1 Packing List
                  Open the package and check the product in the package. In the case of any problem, contact
                  the supplier.

                  Table 2-1 ARDCM-1PHT packing list

                    Item                        Accessory

                    PLC module                  None
                    Integrated assembly (PLC    None
                    module + shell)




2.2 Installation Instructions
                  The ARDCM-1PHT three-phase PLC module must be used on a three-phase PLC meter.
                  Before installing the module, check whether the meter is the matching type.




                             DANGER
                  Installation and commissioning of the module must be performed by trained personnel. Before
                  the installation, turn off the power.


2.2.1 Installation Procedure
         Step 1 Use your fingers to hold the recesses on the PLC module (A and B in the following figure),
                with the indicators on the right. Then mount the PLC module to the meter vertically.




Issue 01 (2016-10-10)                Huawei Proprietary and Confidential                                       8
                                  Copyright © Huawei Technologies Co., Ltd.


ARDCM-1PHT Three-Phase PLC Module
User Manual                                                                              2 Installation Guide

                  Figure 2-1 Installing the PLC module




         Step 2 Check against the following checklist.

                    Item          Status
                    1             The power cables and ground cable are properly connected, meeting
                                  power supply requirements.
                    2             Labels of all cables are correct, clear, and tidy.
                    3             The PLC module is securely mounted on the meter.
                    4             There are no other objects on the meter.




                  ----End



2.3 Module Replacement
                  An ARDCM-1PHT three-phase PLC module can only be replaced with a PLC module of the
                  same model. Before the replacement, check the model of the replacement module. The
                  replacement procedure is similar to the installation procedure.




Issue 01 (2016-10-10)                Huawei Proprietary and Confidential                                   9
                                  Copyright © Huawei Technologies Co., Ltd.


ARDCM-1PHT Three-Phase PLC Module
User Manual                                                                                2 Installation Guide




                               DANGER
                  Installation and commissioning of the module must be performed by trained personnel. Before
                  the replacement, turn off the power.

                  This device complies with part 15 of the FCC Rules. Operation is subject to the following two
                  conditions: (1) This device may not cause harmful interference, and (2) this device must
                  accept any interference received, including interference that may cause undesired operation.
                  Changes or modifications not expressly approved by the party responsible for compliance
                  could void the user's authority to operate the
                  equipment.




Issue 01 (2016-10-10)                Huawei Proprietary and Confidential                                    10
                                  Copyright © Huawei Technologies Co., Ltd.



Document Created: 2016-10-28 15:15:34
Document Modified: 2016-10-28 15:15:34

© 2024 FCC.report