Test Report

FCC ID: ZZH-ZW2P

Test Report

Download: PDF
FCCID_1544959

                                  FCC PART 15.249
       EMI MEASUREMENT AND TEST REPORT
                                              For

WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.
             Tiancheng Industrial Zone,Yueqing, Zhejiang 325608, China



                            FCC ID: ZZH-ZW2P

                                    September 13, 2011

   This Report Concerns:                      Equipment Type:
   Original Report                            Wireless Switch

   Test Engineer:
                            Eric Li
   Report No.:
                            SHBST2011083107Y-1ER-3
   Receive EUT
   Date/Test Date:          September 7, 2011/ September 8-12, 2011
     Reviewed By:
                            Christina
                                             Shenzhen BST Technology Co.,Ltd.
                                             3F,Weames Technology Building,
                                             No. 10 Kefa Road, Science Park,
       Prepared By:                          Nanshan District,Shenzhen,Guangdong,China
                                             Tel: 0755-26747751~3
                                             Fax: 0755-26747751~3 ext.826



  Note: The test report is specially limited to the above company and this particular sample only.
  It may not be duplicated without prior written consent of Shenzhen BST Technology Co.,Ltd.
  This report must not be used by the client to claim product certification,approval,or
  endorsement by NVLAP, NIST or any agency of the US Government.


WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                                                                     FCC ID: ZZH-ZW2P




                                                  TABLE OF CONTENTS

1.     GENERAL INFORMATION ....................................................................................................3
       1.1.   Report information............................................................................................................3
       1.2.   Measurement Uncertainty.................................................................................................3
2.     PRODUCT DESCRIPTION ......................................................................................................4
       2.1.   EUT Description ...............................................................................................................4
       2.2.   Block Diagram of EUT Configuration..............................................................................4
       2.3.   Support Equipment List ....................................................................................................4
       2.4.   Test Conditions .................................................................................................................4
3.     FCC ID LABEL...........................................................................................................................5
4.     TEST RESULTS SUMMARY ...................................................................................................6
       Modifications ................................................................................................................................6
5.     TEST EQUIPMENT USED .......................................................................................................7
6.     ANTENNA REQUIREMENT ...................................................................................................8
       6.1.   STANDARD APPLICABLE............................................................................................8
       6.2.   ANTENNA CONNECTED CONSTRUCTION ..............................................................8
       6.3.   Result ................................................................................................................................8
7.     CONDUCTED POWER LINE TEST .......................................................................................9
       7.1.   Test Equipment .................................................................................................................9
       7.2.   Test Procedure ..................................................................................................................9
       7.3.   Test Setup..........................................................................................................................9
       7.4.   Conducted Power line Emission Limits............................................................................9
       7.5.   Conducted Power Line Test Result.................................................................................10
8.     RADIATED EMISSION TEST ...............................................................................................12
       8.1.   Test Equipment ...............................................................................................................12
       8.2.   Test Procedure ................................................................................................................12
       8.3.   Radiated Test Setup ........................................................................................................12
       8.4.   Radiated Emission Limit.................................................................................................13
       8.5.   Radiated Emission Test Result .......................................................................................14
9.     BAND EDGE .............................................................................................................................17
       9.1.   Test Equipment ...............................................................................................................17
       9.2.   Test Procedure ................................................................................................................17
       9.3.   Band Edge FCC 15.249(d) Limit....................................................................................17
       9.4.   Band Edge Test Result....................................................................................................17




FCC ID REPORT: SHBST2011083107Y-1ER-3                                                                                                     Page 2/19


WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                               FCC ID: ZZH-ZW2P




   1. GENERAL INFORMATION

   1.1. Report information

     1.1.1.This report is not a certificate of quality; it only applies to the sample of the specific
          product/equipment given at the time of its testing. The results are not used to indicate or imply
          that they are application to the similar items. In addition, such results must not be used to
          indicate or imply that BST approves recommends or endorses the manufacture, supplier or use
          of such product/equipment, or that BST in any way guarantees the later performance of the
          product/equipment.

     1.1.2.The sample/s mentioned in this report is/are supplied by Applicant, BST therefore
          assumes no responsibility for the accuracy of information on the brand name, model number,
          origin of manufacture or any information supplied.
          Additional copies of the report are available to the Applicant at an additional fee. No third
           part can obtain a copy of this report through BST, unless the applicant has authorized BST
           in writing to do so.

          Test Facility -
          The test site used to collect the radiated data is located on the address of
          SinTek Laboratory Co.,Ltd.
          (FCC Registered Test Site Number: 963441) on
          No.7, Xinshidai Industrial, Guantian Village, Shiyan Town, Baoan District, Shenzhen,
          Guangdong 518108, China
          The Test Site is constructed and calibrated to meet the FCC requirements.

   1.2. Measurement Uncertainty
          Available upon request.




FCC ID REPORT: SHBST2011083107Y-1ER-3                                                            Page 3/19


WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                             FCC ID: ZZH-ZW2P




   2. PRODUCT DESCRIPTION

   2.1. EUT Description
         Description               : Wireless Switch

         Applicant                 : WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.
                                     Tiancheng Industrial Zone,Yueqing, Zhejiang 325608, China

         Model Number              : ZW2P, ZWN-RS3AA, ZWN-NS3AAA, ZWN-RS1,
                                     ZWN-RS2, ZWN-RS3, ZWNP-R, ZW15S, ZW15R,
                                     MWS-RSC

         Trade Name                : MTLC

         Frequency                 : 908.42MHz

         Number of Channels        : 1

         Power Supply              : AC 120V/60Hz



   2.2. Block Diagram of EUT Configuration


                AC 120V/60Hz
                                         EUT            Incandescent lamp



                              Figure 1 EUT Setup
   2.3. Support Equipment List
                                                                                           Used
         Name             Model No                     S/N              Manufacturer
                                                                                           “√”
           --


   2.4. Test Conditions
          Temperature: 20∼25℃
          Relative Humidity: 50∼63 %




FCC ID REPORT: SHBST2011083107Y-1ER-3                                                         Page 4/19


WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                        FCC ID: ZZH-ZW2P




   3. FCC ID LABEL



                                  FCC ID: ZZH-ZW2P

          This device complies with Part 15 of the FCC Rules.Operation is subject to the
          following two conditions:1. This device may not cause harmful interference, and
          2. This device must accept any interference received, including
          interference that may cause undesired operation.



                                         Label Location on EUT

                                    EUT View/ FCC ID Label Location




FCC ID REPORT: SHBST2011083107Y-1ER-3                                                       Page 5/19


WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                           FCC ID: ZZH-ZW2P




   4. TEST RESULTS SUMMARY
                                  FCC 15 Subpart C, Paragraph 15.249
           FCC Rules              Description of Test          Result
           Section 15.207         Conducted Emission               Compliant
           Section 15.249(a)      The fundamental field strength   Compliant
                                  and the harmonics
           Section 15.209         Radiated Emission                Compliant
           Section 15.249(d)
           Section 15.249(d)      Band Edge                        Compliant
           Section 15.203         Antenna Requirement              Compliant
          Remark: “N/A” means “Not applicable”.

          Statement: All testing was performed using the test procedures found in ANSI C63.4 20003.

          Modifications

          No modification was made.




FCC ID REPORT: SHBST2011083107Y-1ER-3                                                       Page 6/19


WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                                           FCC ID: ZZH-ZW2P




   5. TEST EQUIPMENT USED

                                                                                           Date of           Cal.
            Equipment/Facilities          Manufacturer          Model﹟      Serial no.
                                                                                            Cal.           Interval
                     Cable                  Resenberger           N/A         NO.1       Mar 10,2011        1 Year
                     Cable                SCHWARZBECK             N/A         NO.2       Mar 10,2011        1 Year
                     Cable                SCHWARZBECK             N/A         NO.3       Mar 10,2011        1 Year
                      LISN                Rohde&Schwarz         ESH3-Z5       100305     Mar 10,2011        1 Year
              50Ω Coaxial Switch          ANRITSU CORP           MP59B      6200283933   Mar 10,2011        1 Year
               EMI Test Receiver          Rohde&Schwarz          ESP13        100180     Oct.11,2010        1 Year
               Spectrum Analyzer          Rohde&Schwarz          FSP40        100273     Sep.10,2011        1 Year
               3m Semi-Anechoic           Albatross Projects   9m×6m×6m        N/A       Feb.20,2011        1 Year
                   Chamber
                Signal Generator               FLUKE           PM5418﹢Y/C   LO747012     Feb.20,2011        1 Year
                Signal Generator               FLUKE            PM5418TX    LO738007     Feb.20,2011        1 Year
                 Loop Antenna             SCHWARZBECK           FMZB1516       113       Jan.30,2011        1 Year
         Trilog-Super Broadband Antenna   SCHWARZBECK           VULB9161    9161-4079    Sep.22,2010        1 Year
                Broad-Band Horn           SCHWARZBECK          BBHA9120D    9120D-564    Sep.22,2010        1 Year
                    Antenna
           Ultra Broadband Antenna        Rohde&Schwarz          HL-562       100110     June.15,2011       1 Year
                      AMN                 Rohde&Schwarz         ESH3-Z5       100196     Oct.11,2010        1 Year
                      AMN                 Rohde&Schwarz         ESH3-Z5       100197     Oct.11,2010        1 Year
                  Pulse Limiter           Rohde&Schwarz         ESH3-Z2        N/A           N/A             N/A
                  Power Meter             Rohde&Schwarz          NRVD         100041     Feb.20,2011        1 Year
               EMI Test Receiver          Rohde&Schwarz          ESCS30       100003     Feb.20,2011        1 Year
               Coaxial Cable with         SCHWARZBECK           AK9515H       95549      Sep.22,2010        1 Year
                 N-connectors
             Radio Communication          Rohde&Schwarz          CMS 54     846621/024   Feb.20,2011        1 Year
                    Test Set
              Modulation Analyzer         Hewlett-Packard        8901B      2303A00362   Feb.20,2011        1 Year
                Absorbing clamp           Rohde&Schwarz          MDS-21        N/A       Oct.11,2010        1 Year




FCC ID REPORT: SHBST2011083107Y-1ER-3                                                                       Page 7/19


WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                               FCC ID: ZZH-ZW2P




   6. ANTENNA REQUIREMENT

   6.1. STANDARD APPLICABLE
     For intentional device, according to FCC 47 CFR Section 15.203, an intentional
     radiator shall be designed to ensure that no antenna other than that furnished by
     the responsible party shall be used with the device.
   6.2. ANTENNA CONNECTED CONSTRUCTION
     According to § 15.203, An intentional radiator shall be designed to ensure that no antenna other
     than that furnished by the responsible party shall be used with the device. The use of a permanently
     attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be
     considered sufficient to comply with the provisions of this section. The manufacturer may design
     the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack
     or electrical connector is prohibited.

     The antenna used in this product is PCB antenna. The antenna is permanently attached. Refer to the
     product photo.
   6.3. Result
     Compliance




FCC ID REPORT: SHBST2011083107Y-1ER-3                                                           Page 8/19


WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                              FCC ID: ZZH-ZW2P




   7. CONDUCTED POWER LINE TEST

   7.1. Test Equipment
     Please refer to section 5 this report.
   7.2. Test Procedure
     The EUT and simulators are connected to the main power through a line impedance stabilization
     network (L.I.S.N.).This provides a 50ohm/50uh coupling inpedance for the measuring
     equipment.The peripheral devices are also connected to the main power through a LISN that
     provides a 50ohm/50uh coupling inpedance with 50ohm termination.
     Both sides of A.C. Line are check for maximum conducted interference.In order to find the
     maximum emission,the relative positions of equipment and al of the interface cables must be
     changed according to ASIN C63.4:2003 on conducted measurement .Conducted emissions were
     invested over the frequency range from 0.15MHz to 30MH z using a receiver bandwidth of 9Khz.
   7.3. Test Setup




For the actual test configuration,Please refer to the related items-Photos of testing
   7.4. Conducted Power line Emission Limits

      FCC Part 15 Paragraph 15.207 (dBuV)
      Frequency Range            Class A                Class B
      (MHZ)                      QP/AV                  QP/AV
      0.15-0.5                   79/66                  65-56/56-46
      0.5-5.0                    73/60                  56-46
      5.0-3.0                    73/60                  60-50
Note: In the above table, the tighter limit applies at the band edges.




FCC ID REPORT: SHBST2011083107Y-1ER-3                                                          Page 9/19


WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.   FCC ID: ZZH-ZW2P




   7.5. Conducted Power Line Test Result
          Pass




FCC ID REPORT: SHBST2011083107Y-1ER-3               Page 10/19


WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.   FCC ID: ZZH-ZW2P




FCC ID REPORT: SHBST2011083107Y-1ER-3               Page 11/19


WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                               FCC ID: ZZH-ZW2P




  8. RADIATED EMISSION TEST

    8.1. Test Equipment
Please refer to section 5 this report.
    8.2. Test Procedure
1. The EUT was tested according C63.4-2003.The radiated test was performed at FCC Registration
laboratory .
2. The EUT,peripherals were put on the turntable which table size od 1m×1.5m,table high 0.8m.All set
up is according to ANSI C63.4-2003.
3. The frequency spectrum from 30MHZ to 1 GHZ was investigated.All readings from 30MHZ to 1
GHZ are quasi-peak values with a resolution bandwidth of 120 KHZ. All readings are above
1GHZ ,prak values with a resolution bandwidth of 1 MHZ.Measurements were made at 3 merers.
4. The antenna high is varied from 1m to 4m high to find the maximum emission for each frequency.
5. Maximizing procedure was performed on the six(6)highest emissions to ensure EUT compliance is
with all installation combinations.All data was recorded in the peak detection mode.Quasi-peak
readings was performed only when an emission was found to be marginal (within -4 Db of
            specification
limit),and are distinguished with a “QP”in the data table.
6. The antenna polarization:Vertical polarization and Horizontal polarization.
7. Through three orthogonal axes to determine which attitude and equipment arrangement produces the
highest emission relative to the limit.
    8.3. Radiated Test Setup




For the accrual test configuration,pleas refer to the related items-photos of Testing.




FCC ID REPORT: SHBST2011083107Y-1ER-3                                                           Page 12/19


WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                              FCC ID: ZZH-ZW2P




   8.4. Radiated Emission Limit
All emission from a digital device,including any network of conductors and apparatus connected
thereto,shall not exceed the level of field strength specified below :

A.FCC Part 15 Subpart C Paragraph 15.249(a) Limit
            Frequency                Distance              Field Strength
             (MHZ)                     (m)                   (dBuV/m)
              30-88                     3                       40.0
             88-*216                    3                       43.5
             216-960                    3                       46.0
           ABOVE 960                    3                       54.0
Note:     (1) RF Voltage (dBuV)=20 log Voltage(uV)
         (2) Distance refers to the distance in meters between the measuring instrument antenna and the
             closed point of any part of the device or system.
         (3) The emission limit in this paragraph os based on measurement instrumentation employing
             an average detector.Measurement using instrumentation with a peak detector
             function,corresponding to 20dB above the maximum permitted average limit.

B.Frequencies in restricted band are complied to limit on Paragraph 15.209.

    Fundamental         Field as trength of Fundamental(3m)       Field as trength of Harmonics(3m)
     Frequency
      (MHZ)            mV/m              dBuV/m                   uV/m              dBuV/m
                                               114(Peak
        902~928          50         94(AV)                         500        54(AV)       74(Peak)
                                                              )
                                                   114(Peak
    2400~2483.5          50         94(AV)                         500        54(AV)       74(Peak)
                                                              )

Note: (1) RF Voltage (dBuV)=20 log Voltage(uV)
      (2) In the Above Table,the tighter limit applies at the band edges.
      (3) Distaqnce refers to the distance in meters between the measuring instrument antenna
          and the closed point of any part of the device or system.




FCC ID REPORT: SHBST2011083107Y-1ER-3                                                           Page 13/19


WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                            FCC ID: ZZH-ZW2P




   8.5. Radiated Emission Test Result
        Pass

A. Fundamental Radiated Emissions Data




  Note:
  1. Measurement Level = Reading Level + Correct Factor.
  2. Correct Factor = Antenna Factor + Cable Loss – PreAMP.
  3. The average measurement was not performed when the peak measured data under the limit of
     average detection. If the readings given are average, peak measurement should also be supplied.




FCC ID REPORT: SHBST2011083107Y-1ER-3                                                         Page 14/19


WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                            FCC ID: ZZH-ZW2P




B.Harmonics Radiated Emissions Data




  Note:
  1. Measurement Level = Reading Level + Correct Factor.
  2. Correct Factor = Antenna Factor + Cable Loss – PreAMP.
  3. The average measurement was not performed when the peak measured data under the limit of
     average detection. If the readings given are average, peak measurement should also be supplied.
  4. Emissions attenuated more than 20 dB below the permissible value are not reported.




FCC ID REPORT: SHBST2011083107Y-1ER-3                                                         Page 15/19


WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                        FCC ID: ZZH-ZW2P




C. General Radiated Emissions Data




  Note:
  1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or average
      measurements as necessary.
  2. Measurement Level = Reading Level + Correct Factor
  3. Emissions attenuated more than 20 dB below the permissible value are not reported.




FCC ID REPORT: SHBST2011083107Y-1ER-3                                                       Page 16/19


WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                                FCC ID: ZZH-ZW2P




9. BAND EDGE

   9.1. Test Equipment
Please refer to Section 5 this report.
   9.2. Test Procedure
1. The EUT was tested according C63.4-2003.The radiated test was performed at FCC Registration
laboratory .
2. The transmitter output was connected to the spectrum analyzer via a low lose cable.
Set both RBW and VBW of spectrum analyzer to 100 kHz with suitable frequency
span including 100 MHz bandwidth from band edge. The band edges was measured
and recorded.
3.As the radiation test ,set the Lowest and Highest Transmitting Channel,observed the outside band of
2400MHz to 2438.5MHz,than mark the higher-level emission for comparing with the FCC rules.
   9.3. Band Edge FCC 15.249(d) Limit
In any 100kHz bandwidth outside the frequency band in which the spread spectrum intentional radiator
is operating,the radio frequency power that is produced by the intentional radiator shall be at least
            50dB
below that in the 100kHz bandwidth within the band that contains the desired power,based on either an
RF conducted or a radited measurement,Attenuation below the general limits specified in Section
15.209(a) is not required. In addition,radiated emissions which fall in the restricted bands as defined in
Section 15.205(a),must also comply with the radiated emission limits specitfied in Section 15.209(a)
(see Section 15.205(c)).
   9.4. Band Edge Test Result
   Pass




FCC ID REPORT: SHBST2011083107Y-1ER-3                                                             Page 17/19


WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                     FCC ID: ZZH-ZW2P




Note:
1. Quasi-Peak measurements: RBW=100kHz,VBW=1MHz,Sweep: Auto.
2. Measurement Level = Reading Level + Correct Factor.




FCC ID REPORT: SHBST2011083107Y-1ER-3                                 Page 18/19


WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                       FCC ID: ZZH-ZW2P




Note:
1. Quasi-Peak measurements: RBW=100kHz, VBW=1MHz, Sweep: Auto.
2. Measurement Level = Reading Level + Correct Factor.




FCC ID REPORT: SHBST2011083107Y-1ER-3                                   Page 19/19



Document Created: 2011-09-15 14:00:29
Document Modified: 2011-09-15 14:00:29

© 2024 FCC.report