USERS MANUAL

FCC ID: ZZH-MWS

Users Manual

Download: PDF
FCCID_1686293

INSTALLATION INSTRUCTIONS
                                                              MWS-120,MWS-240                                                                                                             time. LED blinking rapidly, solid On and Off . After 5 minutes , LED
                                                                                                                   COMPONENTS                                                              becomes solid On , Self Test Mode is finished. If LED is off at this time,
             Smart AC Switching Control Receptacle                                                                                                                                         open or close the door ,LED turns On.
                                                                                                            Smart Decorator Duplex Receptacle
                                                                                                                                                                                           Confirming Test:
                                                                                                            (MWS-RSC-120, and MWS-RSC-240)
                                                                                                                                                                                           Make sure transmit device is not detecting anyone, close and open the
                                                                                                                                                                                           door , keep the door open for the next 15 minutes , LED turns Off
                                                                                                                                                                                           between 10 to 15 minutes.Test complete.

                                                                                                                                                                         Indicator
                                                                                                                                                                         Function Button          CODE LEARNING MODE
                                                                                                          Controlled Receptacle                                                            Factory Default:
                   MWS-120                                     MWS-240
                                                                                                                                                                                           The codes are factory preset in a package. However, if there is a need
                                                                                                                                                                    120 Vac                of code match, push the Function button for more than 5 seconds, LED
                                                                                                                                                                                           will become blinking, in the next 30 seconds, transmit device's LED
                                                                                                                                                                     Smart                 turns solid,code is matched.
        SPECIFICATION                                                                                                                                             Receptacle
                                                                                                                                                                                           Note: once a new code in , the old code will be erased in the Smart
 Voltage(MWS-120)............................................................120VAC,60Hz                                                                                                   receptacle.
 Voltage(MWS-240)............................................................240VAC,60Hz
 Load Rating........................................................................................20A                                                                                            TROUBLE SHOOTING
 Operating temperature........................................................30°F to 120°F                                                                             Indicator
 Relative Humidity........................................20% to 90% non-condensing                                                                                     Function Button
                                                                                                                                                                                           LED on Receptacle keep flashing:
 Operating Frequency...................................................................315MHz
                                                                                                          Controlled Receptacle                                                            Run Self Test Mode, if end of batteries , replace them.
 Reception Sensitivity..................................................................-105dBm
 Wireless Transmitting current.........................................................40 mA                                                                                               Power Off 15 minutes even if occupancy:
 Max Wireless Range(direct)................................................within 20 feet                                                                           240 Vac                RF signal is blocked from the transmit device to the receptacle
                                                                                                                                                                     Smart
                                                                                                                                                                   Receptacle              Power On 10-15 minutes even if vacancy:
                                                                                                                   Figure 1                                                                RF signal is blocked from the transmit device to the receptacle
        FEATURE
                                                                                                                                                                                           Receptacle can not recognize signals from Sensor:
          Flush mount 20A Smart Receptacle                                                                  This flush wall mount wiring device meets all the fire and building code       Refer to the CODE LEARNING MODE.
          Constant System Self Testing                                                                      as a receptacle for air conditioner , electric heater, and fan coil for air
          Side wired only                                                                                   conditioning . It receives and processes signals from transmit device,
                                                                                                            make and break the circuit base on occupancy or vacancy of the room.
          Have code function to ensure the uniqueness of device control                                                                                                                             WARRANTY INFORMATION
          One controlled receptacle                                                                         Installation : Connect Hot Line wire to Black screw terminal,Neutral to
          Both are tamper resistant receptacles                                                             White screw Terminal, Ground to Green screw terminal.                          Our company warranties its products to be free of defects in materials
                                                                                                                                                                                           and workmanship for a period of two (2) years. There are no obligations
                                                                                                                                                                                           or liabilities on the part of our company for consequential damages
        DESCRIPTION                                                                                                                                                                       arising out of or in connection with the use or performance of this product
                                                                                                                 TESTING
                                                                                                                                                                                           or other indirect damages with respect to loss of property, revenue , or
 Energy is the basic power for ensuring the working of all machines.To                                     Warming Up:                                                                     profit ,or cost of removal, installation or reinstallation.
 save energy and decrease the daily consumption means that the oper-
 -ation cost will be reduced and the profit will raise. The air conditioner’s                              After connecting power to Smart Receptacle , there are 40 seconds
 energy consumption takes up a majority of the total energy consumption.                                   warming up time.
                                                                                                                                                                                                                                                          Feb,2012
 Therefore s set of energy-saving air conditioning control system is fairly                                 When both LEDs of Smart Receptacle and transmit devices flash twice.
  essential.                                                                                                If not, go to Code Learn Mode.
 The air conditioning auto control system is made up of three parts: two                                   Self Test Mode:
 transmit devices and one receive smart receptacle, each of which
 communicates wireless with the receptacle in a single room, to control                                     Push the Function button on Smart Receptacle only once, LED blinks
 the air conditioning auto on/auto off, then can save energy and make                                       once , the system is now Self Test mode, do not plug in the load at this
 the air conditioner more intelligent.




                                            -01-                                                                                               -02-                                                                        -03-


FCC STATEMENT
1. This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
2. Changes or modifications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-- Consult the dealer or an experienced radio/TV technician for help.