TEST REPORT

FCC ID: ZZH-MWS

Test Report

Download: PDF
FCCID_1686291

                             FCC PART 15 CLASS B
       EMI MEASUREMENT AND TEST REPORT
                                             For

WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.
            Tiancheng Industrial Zone,Yueqing, Zhejiang 325608, China




                             FCC ID: ZZH-MWS

                                     April 24, 2012

  This Report Concerns:                      Equipment Type:
  Original Report                            Receptacle

    Test Engineer:
                           Eric Li
        Report No.:        BST12040063Y-1ER-3
   Receive EUT
                           April 18, 2012/ April 19-23, 2012
  Date/Test Date:
    Reviewed By:
                           Christina
                                            Shenzhen BST Technology Co.,Ltd.
                                            3F,Weames Technology Building,
                                            No. 10 Kefa Road,Science Park,
      Prepared By:                          Nanshan District,Shenzhen,Guangdong,China
                                            Tel: 0755-26747751~3
                                            Fax: 0755-26747751~3 ext.826




 Note: The test report is specially limited to the above company and this particular sample only.
 It may not be duplicated without prior written consent of Shenzhen BST Technology Co.,Ltd.
 This report must not be used by the client to claim product certification,approval,or
 endorsement by NVLAP, NIST or any agency of the US Government.


  WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                                                                   FCC ID: ZZH-MWS



                                                   TABLE OF CONTENTS

1.     GENERAL INFORMATION ....................................................................................................3
       1.1.   Report information............................................................................................................3
       1.2.   Measurement Uncertainty.................................................................................................3
2.     PRODUCT DESCRIPTION ......................................................................................................4
       2.1.   EUT Description ...............................................................................................................4
       2.2.   Block Diagram of EUT Configuration .............................................................................4
       2.3.   Support Equipment List ....................................................................................................4
       2.4.   Test Conditions .................................................................................................................4
3.     FCC ID LABEL...........................................................................................................................5
4.     TEST RESULTS SUMMARY ...................................................................................................6
       Modifications ................................................................................................................................6
5.     TEST EQUIPMENT USED .......................................................................................................7
6.     CONDUCTED EMISSION TEST.............................................................................................8
       6.1.   Block Diagram of Test Setup............................................................................................8
       6.2.   Test Standard ....................................................................................................................8
       6.3.   Conducted Emission Limit(Class B) ................................................................................9
       6.4.   EUT Configuration on Test ..............................................................................................9
       6.5.   Operating Condition of EUT ............................................................................................9
       6.6.   Test Procedure ..................................................................................................................9
       6.7.   Test Result ........................................................................................................................9
7.     RADIATED EMISSION MEASUREMENT .........................................................................12
       7.1.   Block Diagram of EUT Configuration ...........................................................................12
       7.2.   Test Standard ..................................................................................................................13
       7.3.   Radiated Emission Limit(Class B) .................................................................................13
       7.4.   EUT Configuration on Test ............................................................................................14
       7.5.   Operating Condition of EUT ..........................................................................................14
       7.6.   Test Procedure ................................................................................................................14
       7.7.   Test Result ......................................................................................................................14




BST FCC ID REPORT: BST12040063Y-1ER-3                                                                                                        Page 2/16


 WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                               FCC ID: ZZH-MWS




     1. GENERAL INFORMATION

   1.1. Report information

     1.1.1.This report is not a certificate of quality; it only applies to the sample of the specific
          product/equipment given at the time of its testing. The results are not used to indicate or imply
          that they are application to the similar items. In addition, such results must not be used to
          indicate or imply that BST approves recommends or endorses the manufacture, supplier or use
          of such product/equipment, or that BST in any way guarantees the later performance of the
          product/equipment.

     1.1.2.The sample/s mentioned in this report is/are supplied by Applicant, BST therefore
          assumes no responsibility for the accuracy of information on the brand name, model number,
          origin of manufacture or any information supplied.
          Additional copies of the report are available to the Applicant at an additional fee. No third part
          can obtain a copy of this report through BST, unless the applicant has authorized BST in
          writing to do so.

          Test Facility -
          The test site used to collect the radiated data is located on the address of
          SinTek Laboratory Co.,Ltd.
          (FCC Registered Test Site Number: 963441) on
          No.7, Xinshidai Industrial, Guantian Village, Shiyan Town, Baoan District, Shenzhen,
          Guangdong 518108, China
          The Test Site is constructed and calibrated to meet the FCC requirements.

   1.2. Measurement Uncertainty
          Available upon request.




BST FCC ID REPORT: BST12040063Y-1ER-3                                                               Page 3/16


 WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                         FCC ID: ZZH-MWS




     2. PRODUCT DESCRIPTION

   2.1. EUT Description

      Applicant               :    WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.

      Address                 :    Tiancheng Industrial Zone,Yueqing, Zhejiang 325608, China

      Manufacturer            :    WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.

      Address                 :    Tiancheng Industrial Zone,Yueqing, Zhejiang 325608, China

      EUT Description         :    Receptacle

      Model Number            :    MWS

      Frequency               :    315MHz

      Power Supply            :    AC 100-277V, 50/60Hz


   2.2. Block Diagram of EUT Configuration

                AC 120V/60Hz
                                        EUT             Incandescent lamp



                  Figure 1 EUT Setup

     2.3. Support Equipment List
                                                                                     Used
                   Name                 Model No         S/N        Manufacturer
                                                                                     “√”
                    N/A                   N/A            N/A            N/A           N/A


     2.4. Test Conditions
             Temperature: 20∼25℃
             Relative Humidity: 50∼63 %




BST FCC ID REPORT: BST12040063Y-1ER-3                                                          Page 4/16


 WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                       FCC ID: ZZH-MWS




     3. FCC ID LABEL



                                   FCC ID: ZZH-MWS

          This device complies with Part 15 of the FCC Rules. Operation is subject to the
          following two conditions: 1. This device may not cause harmful interference, and
          2. This device must accept any interference received, including
          interference that may cause undesired operation.



                                             Label Location on EUT

                                        EUT View/ FCC ID Label Location




BST FCC ID REPORT: BST12040063Y-1ER-3                                                        Page 5/16


 WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                          FCC ID: ZZH-MWS




     4. TEST RESULTS SUMMARY
                                            Table 1 Test Results Summary
                             Test Items                             Test Results
                       Conducted disturbance                           Pass
                        Radiated disturbance                           Pass

          Remark: “N/A” means “Not applicable.”

          Statement: All testing was performed using the test procedures found in ANSI C63.4-2003.



          Modifications

          No modification was made.




BST FCC ID REPORT: BST12040063Y-1ER-3                                                         Page 6/16


 WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                                          FCC ID: ZZH-MWS




     5. TEST EQUIPMENT USED

                                                                                           Date of          Cal.
            Equipment/Facilities          Manufacturer          Model﹟      Serial no.
                                                                                            Cal.          Interval
                     Cable                  Resenberger           N/A          NO.1      Mar 10,2012       1 Year
                     Cable                SCHWARZBECK             N/A          NO.2      Mar 10,2012       1 Year
                     Cable                SCHWARZBECK             N/A          NO.3      Mar 10,2012       1 Year
                      LISN                Rohde&Schwarz         ESH3-Z5       100305     Mar 10,2012       1 Year
              50Ω Coaxial Switch          ANRITSU CORP           MP59B      6200283933   Mar 10,2012       1 Year
               EMI Test Receiver          Rohde&Schwarz          ESP13        100180     Oct.11,2011       1 Year
               Spectrum Analyzer          Rohde&Schwarz          FSP40        100273     Sep.10,2011       1 Year
               Spectrum Analyzer               Agilent           E4446A     US44300459   Sep.10,2011       1 Year
               3m Semi-Anechoic           Albatross Projects   9m×6m×6m        N/A       Feb.20,2012       1 Year
                   Chamber
                Signal Generator               FLUKE           PM5418﹢Y/C   LO747012     Feb.20,2012       1 Year
                Signal Generator               FLUKE            PM5418TX    LO738007     Feb.20,2012       1 Year
                 Loop Antenna             SCHWARZBECK           FMZB1516       113       Jan.30,2012       1 Year
         Trilog-Super Broadband Antenna   SCHWARZBECK           VULB9161    9161-4079    Sep.22,2011       1 Year
                Broad-Band Horn           SCHWARZBECK          BBHA9120D    9120D-564    Sep.22,2011       1 Year
                    Antenna
           Ultra Broadband Antenna        Rohde&Schwarz          HL-562       100110     June.15,2011      1 Year
                      AMN                 Rohde&Schwarz         ESH3-Z5       100196     Oct.11,2011       1 Year
                      AMN                 Rohde&Schwarz         ESH3-Z5       100197     Oct.11,2011       1 Year
                  Pulse Limiter           Rohde&Schwarz         ESH3-Z2        N/A           N/A            N/A
                  Power Meter             Rohde&Schwarz          NRVD         100041     Feb.20,2012       1 Year
               EMI Test Receiver          Rohde&Schwarz          ESCS30       100003     Feb.20,2012       1 Year
               Coaxial Cable with         SCHWARZBECK           AK9515H       95549      Sep.22,2011       1 Year
                 N-connectors
             Radio Communication          Rohde&Schwarz          CMS 54     846621/024   Feb.20,2012       1 Year
                    Test Set
              Modulation Analyzer         Hewlett-Packard        8901B      2303A00362   Feb.20,2012       1 Year
                Absorbing clamp           Rohde&Schwarz          MDS-21        N/A       Oct.11,2011       1 Year




BST FCC ID REPORT: BST12040063Y-1ER-3                                                                        Page 7/16


 WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                   FCC ID: ZZH-MWS




     6. CONDUCTED EMISSION TEST

     6.1. Block Diagram of Test Setup

       6.1.1.Block Diagram of connection between the EUT and the simulators

              AC 120V/60Hz
                                        EUT           Incandescent lamp



                Figure 1 EUT Setup


       6.1.2.Test Setup Diagram




     6.2. Test Standard
             FCC Part 15 CLASS B
             ANSI C63.4 2003




BST FCC ID REPORT: BST12040063Y-1ER-3                                                Page 8/16


 WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                           FCC ID: ZZH-MWS




     6.3. Conducted Emission Limit(Class B)


                  Frequency                                    Limits dB(µV)
                    MHz                 Quasi-peak Level             Average Level
           0.15      ~     0.50             66 ~ 56*                   56 ~ 46*
           0.50      ~     5.00                56                        46
           5.00      ~    30.00                60                        50

             Notes: 1. *Decreasing linearly with logarithm of frequency.

     6.4. EUT Configuration on Test
             The following equipments are installed on conducted emission test to meet FCC Part 15
             requirement and operating in a manner, which tends to maximize its emission characteristics
             in a normal application.
     6.5. Operating Condition of EUT

       6.5.1.Setup the EUT and simulators as shown in Section 6.1.

       6.5.2.Turn on the power of all equipments.

       6.5.3.Let the EUT work in test mode (RX) and test it.

     6.6. Test Procedure
             The EUT is put on a table of non-conducting material that is 80cm high. The vertical
             conducting wall of shielding is located 40cm to the rear of the EUT. The power line of the
             EUT is connected to the AC mains through a Artificial Mains Network (A.M.N.). A EMI test
             receiver (R&S Test Receiver ESCS30) is used to test the emissions form both sides of AC
             line. The bandwidth of EMI test receiver is set at 9kHz.

     6.7. Test Result
             Pass




BST FCC ID REPORT: BST12040063Y-1ER-3                                                          Page 9/16


 WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.   FCC ID: ZZH-MWS




      N Line




BST FCC ID REPORT: BST12040063Y-1ER-3                Page 10/16


 WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.   FCC ID: ZZH-MWS




      L Line




BST FCC ID REPORT: BST12040063Y-1ER-3                Page 11/16


 WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                   FCC ID: ZZH-MWS




     7. RADIATED EMISSION MEASUREMENT

     7.1. Block Diagram of EUT Configuration

       7.1.1.Block Diagram of connection between the EUT and the simulators

              AC 120V/60Hz
                                        EUT           Incandescent lamp


                Figure 1 EUT Setup

       7.1.2.Radiated Test Setup Diagram
          1) Radiated Emission Test Set-Up, Frequency Below 30MHz




          2) Radiated Emission Test Set-Up, Frequency Below 1000MHz




BST FCC ID REPORT: BST12040063Y-1ER-3                                                Page 12/16


 WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                          FCC ID: ZZH-MWS




          3) Radiated Emission Test Set-Up, Frequency above 1000MHz




     7.2. Test Standard
                FCC Part 15 CLASS B
                ANSI C63.4 2003

     7.3. Radiated Emission Limit(Class B)
                                                        Limit
   Frequency        Field Strength of   Field Strength of                             The final
                                                                Measurement
     (MHz)          Quasi-peak Value    Quasi-peak Value                        measurement in band
                                                                distance (m)
                     (microvolts/m)        (dBµV/m)                                   9-90kHz,
                                                                                  110-490kHz and
  0.009 - 0.490        2400/F(kHz)              /                   300
                                                                                 above 1000MHz is
  0.490 - 1.705        24000/F(kHz)             /                    30            performed with
                                                                                  Average detector.
    1.705-30               30                  29.5                  30             Except those
                                                                                  frequency bands
     30 - 88               100                  40                   3
                                                                                 mention above, the
     88 - 216              150                 43.5                  3           final measurement
                                                                                   for frequencies
    216 - 960              200                  46                   3           below 1000MHz is
                                                                                   performed with
   Above 960               500                  54                   3          Quasi Peak detector.
Note: (1) RF Voltage (dBuV)=20 log Voltage(uV)
(2) In the Above Table,the tighter limit applies at the band edges.
(3) Distaqnce refers to the distance in meters between the measuring instrument antenna and the closed
point of any part of the device or system.




BST FCC ID REPORT: BST12040063Y-1ER-3                                                         Page 13/16


 WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.                                            FCC ID: ZZH-MWS




     7.4. EUT Configuration on Test
             The following equipment are installed on Radiated Emission Measurement to meet the
             Commission requirements and operating regulations in a manner which tends to maximize
             Its emission characteristics in normal application.
     7.5. Operating Condition of EUT

       7.5.1.Setup the EUT as shown on Section 7.1

       7.5.2.Turn on the power of all equipments.

       7.5.3.Let the EUT work in test mode (RX) and measure it.


     7.6. Test Procedure
             The EUT and its simulators are placed on a turntable, which is 0.8 meter high above ground.
             The turntable can rotate 360 degrees to determine the position of the maximum emission level.
             EUT is set 3.0 meters away from the receiving antenna, which is mounted on an antenna
             tower. The antenna can be moved up and down between 1.0 meter and 4 meters to find out
             the maximum emission level.

             Calibrated Loop antenna is used as receiving antenna for frequencies below 30MHz,
             Calibrated Bilog antenna is used as receiving antenna for frequencies between 30 MHz and 1
             GHz, Calibrated Horn antenna is used as receiving antenna for frequencies above 1000MHz.
             Both horizontal and vertical polarizations of the antenna are set on measurement. In order to
             find the maximum emission levels, all of the interface cables must be manipulated according
             to ANSI C63.4: 2003 on radiated emission measurement.

             The bandwidth of test receiver is set at 9kHz in below 30MHz. and set at 120kHz in
             30-1000MHz, and 1MHz in above 1000MHz.

             The frequency range from 9kHz to 2GHz is checked.

             The final measurement in band 9-90kHz, 110-490kHz and above 1000MHz is performed with
             Peak detector and Average detector. Except those frequency bands mention above, the final
             measurement for frequencies below 1000MHz is performed with Quasi Peak detector.

             Through three orthogonal axes to determine which attitude and equipment arrangement
             produces the

     7.7. Test Result
             PASS




BST FCC ID REPORT: BST12040063Y-1ER-3                                                             Page 14/16


 WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.   FCC ID: ZZH-MWS



 Below 1GHz

 Horizontal polarization




 Vertical polarization




BST FCC ID REPORT: BST12040063Y-1ER-3                Page 15/16


 WENZHOU MTLC ELECTRIC APPLIANCES CO., LTD.   FCC ID: ZZH-MWS



 Above 1GHz

 Horizontal polarization




 Vertical polarization




BST FCC ID REPORT: BST12040063Y-1ER-3                Page 16/16



Document Created: 2012-04-24 19:03:56
Document Modified: 2012-04-24 19:03:56

© 2024 FCC.report