RF Exposure Info

FCC ID: ZZ2-AMC057

RF Exposure Info

Download: PDF
FCCID_4494137

                                            SGS-CSTC Standards Technical Services Co.,
                                            Ltd. Shanghai Branch
                                                                                        Report No.: SHEM190801658802
                                                                                        Page:       1 of 8


  1       Cover Page

                    RF Exposure Evaluation Report
  Application No.:                       SHEM1908016588CR
  FCC ID:                                ZZ2-AMC057
  IC:                                    21923-AMC057
  Applicant:                             Amcrest Technologies LLC
  Address of Applicant:                  16727 Park Row Dr, Houston, TX 77084
  Manufacturer:                          Amcrest Technologies LLC
  Address of Manufacturer:               16727 Park Row Dr, Houston, TX 77084
  Equipment Under Test (EUT):
  EUT Name:                1080P Pan/Tilt wireless IP Camera
  Model No.:               IP2M-841W-V3
  Add Model No.:           IP2M-841B-V3
                           FCC Rules 47 CFR §2.1091
  Standard(s) :            KDB447498  D01 General RF Exposure Guidance v06
                           RSS-102 Issue 5 (March 2015)
  Date of Receipt:                       2019-08-26
  Date of Test:                          2019-08-29 to 2019-09-09
  Date of Issue:                         2019-09-09
  Test Result:                     Pass*
  * In the configuration tested, the EUT complied with the standards specified above.




               Parlam Zhan
            E&E Section Manager
The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report.
If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new
system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS
International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by
SGS International Electrical Approvals in writing.


               SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
               Branch
                                                          Report No.: SHEM190801658802
                                                          Page:       2 of 8




                                   Revision Record
  Version        Description                    Date                     Remark

      00           Original                  2019-09-09                     /




Authorized for issue
by:




                              Micheal Niu / Project Engineer




                              Parlam Zhan / Reviewer


                                    SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                                    Branch
                                                                                                         Report No.: SHEM190801658802
                                                                                                         Page:       3 of 8




2         Contents
                                                                                                                                                             Page
1     COVER PAGE ................................................................................................................................................ 1
2     CONTENTS ..................................................................................................................................................... 3
3     GENERAL INFORMATION .......................................................................................................................... 4
    3.1       GENERAL DESCRIPTION OF E.U.T. ......................................................................................................... 4
    3.2       TECHNICAL SPECIFICATIONS ................................................................................................................... 4
    3.3       TEST LOCATION ....................................................................................................................................... 5
    3.4       TEST FACILITY.......................................................................................................................................... 5
4     TEST STANDARDS AND LIMITS ............................................................................................................... 6
    4.1       FCC RADIOFREQUENCY RADIATION EXPOSURE LIMITS: ......................................................................... 6
    4.2       IC RADIOFREQUENCY RADIATION EXPOSURE LIMITS: ............................................................................. 6
5     MEASUREMENT AND CALCULATION .................................................................................................... 7
    5.1       MAXIMUM TRANSMIT POWER.................................................................................................................... 7
    5.2       MPE CALCULATION ................................................................................................................................. 8


                      SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                      Branch
                                                        Report No.: SHEM190801658802
                                                        Page:       4 of 8




3    General Information

3.1 General Description of E.U.T.
                             AC 120V/50Hz By Adapter
                             Adapter: Model: E010-1D050150VUU
    Product Description:
                             Input:100~240V, 50/60Hz,0.3A
                             Output: DC 5.0V/1.5A
    Test voltage:            AC 120V/60Hz
    Cable:                   DC-DC Cable: Unshielding 280cm

3.2 Technical Specifications
    Antenna Gain             0.92dBi
    Antenna Type             Chip Antenna
    Channel Spacing          5MHz
                             802.11b: DSSS (CCK, DQPSK, DBPSK)
    Modulation Type
                             802.11g/n: OFDM (64QAM, 16QAM, QPSK, BPSK)
                             802.11b/g/n(HT20):11
    Number of Channels
                             802.11n(HT40):7
                             802.11b/g/n(HT20): 2412MHz to 2462MHz
    Operation Frequency
                             802.11n(HT40): 2422MHz to 2452MHz


                       SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                       Branch
                                                                     Report No.: SHEM190801658802
                                                                     Page:       5 of 8




3.3 Test Location
      All tests were performed at:
      SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch
      588 West Jindu Road, Xinqiao, Songjiang, 201612 Shanghai, China.
      Tel: +86 21 6191 5666
      Fax: +86 21 6191 5678

3.4 Test Facility
      The test facility is recognized, certified, or accredited by the following organizations:
      • CNAS (No. CNAS L0599)
      CNAS has accredited SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. to ISO/IEC
      17025:2005 General Requirements for the Competence of Testing and Calibration Laboratories
      (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration Laboratories) for
      the competence in the field of testing.
      • NVLAP (Certificate No. 201034-0)
      SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. is accredited by the National
      Voluntary Laboratory Accreditation Program(NVLAP). Certificate No. 201034-0.
      • FCC –Designation Number: CN5033
      SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. has been recognized as an
      accredited testing laboratory.
      Designation Number: CN5033. Test Firm Registration Number: 479755.
      • Innovation, Science and Economic Development Canada
      SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. EMC Laboratory has been
      recognized by ISED as an accredited testing laboratory.
      IC Registration No.: 8617A-1. CAB Identifier: CN0020.
      • VCCI (Member No.: 3061)
      The 3m Semi-anechoic chamber and Shielded Room of SGS-CSTC Standards Technical Services
      (Shanghai) Co., Ltd. has been registered in accordance with the Regulations for Voluntary Control
      Measures with Registration No.: R-13868, C-14336, T-12221, G-10830 respectively.


                        SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                        Branch
                                                                     Report No.: SHEM190801658802
                                                                     Page:       6 of 8




4    Test Standards and Limits

4.1 FCC Radiofrequency radiation exposure limits:
 According to§1.1310, the limit for general population/uncontrolled exposures

         Frequency              Power density(mW/cm2)         Averaging time(minutes)

     300MHz~1.5GHz                        f/1500                          30

      1.5GHz~100GHz                        1.0                            30


4.2 IC Radiofrequency radiation exposure limits:
 According to RSS-102 section 2.5.2, RF exposure evaluation is required if the separation distance
 between the user and/or bystander and the device’s radiating element is greater than 20 cm, except
 when the device operates as follows:
 below 20 MHz and the source-based, time-averaged maximum e.i.r.p. of the device is equal to or less
 than 1 W (adjusted for tune-up tolerance);
 • at or above 20 MHz and below 48 MHz and the source-based, time-averaged maximum e.i.r.p. of the
 device is equal to or less than 4.49/ƒ0.5 W (adjusted for tune-up tolerance), where ƒ is in MHz;
 • at or above 48 MHz and below 300 MHz and the source-based, time-averaged maximum e.i.r.p. of
 the device is equal to or less than 0.6 W (adjusted for tune-up tolerance);
 • at or above 300 MHz and below 6 GHz and the source-based, time-averaged maximum e.i.r.p. of the
 device is equal to or less than 1.31 x 10-2 ƒ0.6834 W (adjusted for tune-up tolerance), where ƒ is in MHz;
 • at or above 6 GHz and the source-based, time-averaged maximum e.i.r.p. of the device is equal to or
 less than 5 W (adjusted for tune-up tolerance).
 For 2.4G device, the limit of worse case is 2.68 W


                    SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                    Branch
                                                          Report No.: SHEM190801658802
                                                          Page:       7 of 8




5     Measurement and Calculation

5.1 Maximum transmit power
 The Power Data is based on the RF Test Report SHEM190801658801
       Test               Test                          Power             Power
                                          Ant
      Mode              Channel                         [dBm]             [mW]
                        2412           Ant1            17.05               50.70
       802.11b          2437           Ant1            16.83               48.19
                        2462           Ant1            17.00               50.12
                        2412           Ant1            16.76               47.42
       802.11g          2437           Ant1            16.57               45.39
                        2462           Ant1            16.84               48.31
                        2412           Ant1            16.63               46.03
    802.11n(HT20)       2437           Ant1            16.46               44.26
                        2462           Ant1            16.60               45.71
                        2422           Ant1            16.45               44.16
    802.11n(HT40)       2437           Ant1            16.58               45.50
                        2452           Ant1            16.77               47.53


                          SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                          Branch
                                                                     Report No.: SHEM190801658802
                                                                     Page:       8 of 8




5.2 MPE Calculation
For FCC:
   According to the formula S=PG/4πR², we can calculate S which is MPE.
   Note:
   1)     P (mW)
   2)     R = distance to the center of radiation of antenna (in meter) = 20cm
   3)     MPE limit = 1mW/cm²

  The max. antenna gain is           0.92     dBi
     Max.
            Gain in Linear        Operation      Power
  Conducted                                               Limit
                Scale             Distance      Density                 Result
    Power                                               (mW/cm2)
                  G                R(cm)       (mW/cm2)
   P(mW)
        50.7         1.236            20       0.01247         1         Pass


 For IC:
 E.I.R.P.= P*G= 0.0507×1.236=0.063W<2.68W
So the device is exclusion from SAR test.

                                           --End of the Report--



Document Created: 2019-10-29 15:23:48
Document Modified: 2019-10-29 15:23:48

© 2024 FCC.report