RF test report

FCC ID: ZY4CM16

Test Report

Download: PDF
FCCID_4149116

Report Number: 68.910.18.0063.01




                                                               FCC - TEST REPORT




Report Number                                          : 68.910.18.0063.01                               Date of Issue:                    December 28, 2018


Model                                                  : CM-16

Product Type                                           : 4 Channel Wall remote

Applicant                                              : Coulisse B.V.

Address                                                : Vonderweg 48, 7468 DC Enter, THE NETHERLANDS

Production Facility                                    : Ningbo Dooya Mechanic & Electronic Technology Co., Ltd.

Address                                                : No.168 Shengguang Road, Luotuo, Zhenhai 315202 Ningbo,

                                                       : Zhejiang province, PEOPLE'S REPUBLIC OF CHINA




Test Result                                            : n Positive                    o Negative



Total pages including
Appendices                                             : 15




TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in
ISO 17025.


TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test conditions. Construction of
the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with
identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the
production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch shall have no
liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
issued reports.


This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be
reproduced except in full without our written approval




EMC_SZ_FR_21.00 FCC                                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                               Page 1 of 15
                                           Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0063.01




1      Table of Contents
1      Table of Contents ........................................................................................................................................................... 2
2      Details about the Test Laboratory.................................................................................................................................... 3
3      Description of the Equipment Under Test ........................................................................................................................ 4
4      Summary of Test Standards ............................................................................................................................................ 5
5      Summary of Test Results ................................................................................................................................................ 6
6      General Remarks ............................................................................................................................................................ 7
7      Systems test configuration .............................................................................................................................................. 8
8      Test Setups ..................................................................................................................................................................... 9
9      Test Methodology......................................................................................................................................................... 10
     9.1      Radiated Emission ................................................................................................................................................ 10
     9.2      Bandwidth Measurement ...................................................................................................................................... 12
     9.3      Deactivation Time ................................................................................................................................................ 13
10     Test Equipment List...................................................................................................................................................... 14
11     System Measurement Uncertainty ................................................................................................................................. 15




EMC_SZ_FR_21.00 FCC                                        TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                                       Page 2 of 15
                                             Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                                  Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0063.01




2   Details about the Test Laboratory
Details about the Test Laboratory
Test Site 1

Company name:         TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
                      Building 12&13, Zhiheng Wisdomland Business Park,
                      Nantou Checkpoint Road 2, Nanshan District,
                      Shenzhen City, 518052,
                      P. R. China

FCC Registration      514049
Number:

Telephone:            86 755 8828 6998
Fax:                  86 755 8828 5299




EMC_SZ_FR_21.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 3 of 15
                         Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0063.01




3   Description of the Equipment Under Test


Product:                    4 Channel Wall remote

Model no.:                  CM-16

FCC ID:                     ZY4CM16

Rating:                     3VDC (Supplied by 3*CR2430 battery in parallel)

RF Transmission             433.925MHz
Frequency:

Modulation:                 FSK

Antenna Type:               PCB Antenna

Antenna Gain:               1.0dBi

Description of the EUT: The Equipment Under Test (EUT) is a 4 Channel Wall remote
                        operated at 433.925MHz




EMC_SZ_FR_21.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 4 of 15
                         Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0063.01




4   Summary of Test Standards

                                         Test Standards
FCC Part 15 Subpart C       PART 15 - RADIO FREQUENCY DEVICES
10-1-2017 Edition           Subpart C - Intentional Radiators

All the test methods were according to ANSI C63.10.




EMC_SZ_FR_21.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 5 of 15
                         Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0063.01




5   Summary of Test Results

                                             Technical Requirements
    FCC Part 15 Subpart C
    Test Condition                                                                     Pages         Test Site              Test Result
    §15.207                                     Conducted emission                      N/A            N/A                      Not
                                                AC power port                                                               Applicable
    §15.205, §15.209,                           Radiated Emission,                        10            Site 1                 Pass
    15.35 (c)§15.231 (b)                        30MHz to 4.5GHz
    §15.231(c)                                  Bandwidth                                 12            Site 1                 Pass
                                                Measurement
    §15.231(a) (1)                              Deactivation Time                         13            Site 1                 Pass


Note 1: N/A=Not Applicable.
Note 2: The EUT uses a PCB Antenna, which gain is 1.0dBi. In accordance to §15.203, It is considered
sufficiently to comply with the provisions of this section.




EMC_SZ_FR_21.00 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                    Page 6 of 15
                           Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0063.01




6    General Remarks
Remarks

This submittal(s) (test report) is intended for FCC ID: ZY4CM16 complies with Section 15.209,
15.231 of the FCC Part 15.

SUMMARY:

All tests according to the regulations cited on page 5 were

n - Performed

o - Not Performed

The Equipment Under Test

n - Fulfills the general approval requirements.

o - Does not fulfill the general approval requirements.


Sample Received Date:                       August 31, 2018

Testing Start Date:                         August 31, 2018

Testing End Date:                        September 17, 2018

TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch


Reviewed by:                           Prepared by:                                    Tested by:




    _______________________                 _______________________                           _______________________
        Phoebe Hu                             Mark Chen                                              Tree Zhan
    EMC Section Manager                   EMC Project Engineer                                    EMC Test Engineer




EMC_SZ_FR_21.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 7 of 15
                         Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0063.01



7   Systems test configuration

Auxiliary Equipment Used during Test:

            DESCRIPTION            MANUFACTURER                     MODEL NO.(SHIELD)                    S/N(LENGTH)
                   --                          --                                 --                          --




EMC_SZ_FR_21.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 8 of 15
                         Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0063.01



8     Test Setups

7.1 Radiated test setups

Below 1GHz




Above 1GHz




7.2 Conducted RF test setups


    Measuring                 EUT
    Receiver




EMC_SZ_FR_21.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 9 of 15
                         Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0063.01



9   Test Methodology

9.1 Radiated Emission

Test Method

    1: The EUT was place on a turn table which is 1.5m above ground plane for above 1GHz
    and 0.8m above ground for below 1GHz at 3 meter chamber room for test. The table was
    rotated 360 degrees to determine the position of the highest radiation.
    2: The EUT was set 3 meters away from the interference – receiving antenna, which was
    mounted on the top of a variable – height antenna tower.
    3: The height of antenna is varied from one meter to four meters above the ground to
    determine the maximum value of the field strength. Both horizontal and vertical polarizations
    of the antenna are set to make the measurement.
    4: For each suspected emission, the EUT was arranged to its worst case and then the
    antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was turned
    from 0 degrees to 360 degrees to find the maximum reading.
    5: Use the following spectrum analyzer settings According to C63.10:
    For Above 1GHz
        Span = wide enough to capture the peak level of the in-band emission and all spurious
        RBW = 1MHz, VBW≥RBW for peak measurement and VBW = 10Hz for average
        measurement, Sweep = auto, Detector function = peak, Trace = max hold.
    For Below 1GHz
    Use the following spectrum analyzer settings:
        Span = wide enough to capture the peak level of the in-band emission and all spurious
        RBW = 100 KHz, VBW≥RBW for peak measurement, Sweep = auto, Detector function =
        peak, Trace = max hold.

Limit

According to §15.231 (b), the field strength of emissions from intentional radiators operated
under this section shall not exceed the following:

            Fundamental frequency                Field Strength of                      Field Strength of spurious
                                              Fundamental (Microvolts                     emissions ((Microvolts
                   (MHz)
                                                      /meter)                                     /meter)
                  40.66-40.70                          2,250                                        225
                     70-130                            1,250                                        125
                    130-174                       1,250 to 3,370 *                              125 to 375 *
                    174-260                            3,750                                        375
                   260-470 √                     3,750 to 12, 500*                             375 to 1,250*
                  Above 470                           12,500                                       1,250




EMC_SZ_FR_21.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 10 of 15
                         Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0063.01



Spurious radiated emissions for transmitter
According to C63.10, if the peak (or quasi-peak) measured value complies with the average limit, it is unnecessary to perform an
average measurement, so AV emission value did not show in below table if the peak value complies with average limit.

                                                              Radiated Emissions
    Value   Emissions             E-Field        Field       Average       Net Field         Limit         Margin             Emission
            Frequency             Polarity      at 3m         Factor        at 3m                                              Type
               MHz                             dBµV/m          dB          dBµV/m          dBµV/m
    Below 1GHz
      PK     433.925                 H           77.02          0.00         77.02          100.83          23.81           Fundamental
      AV     433.925                 H           77.02          0.00         77.02          80.83            3.81           Fundamental
      PK     433.925                 V           55.60          0.00         55.60          100.83          45.23           Fundamental
      AV     433.925                 V           55.60          0.00         55.60          80.83           25.23           Fundamental
      PK     867.910                 H           43.31          0.00         43.31          80.83           37.52             Spurious
      AV     867.910                 H           43.31          0.00         43.31          60.83           17.52             Spurious
      PK     867.910                 V           32.48          0.00         32.48          80.83           48.35             Spurious
      AV     867.910                 V           32.48          0.00         32.48          60.83           28.35             Spurious
    Above 1GHz
      PK      1239.3                 H           45.82          0.00         45.82             74           28.18              Spurious
      AV      1239.3                 H           45.82           0           45.82             54            8.18              Spurious
      PK      1752.9                 V           47.97          0.00         47.97             74           26.03              Spurious
      AV      1752.9                 V           47.97           0           47.97             54            6.03              Spurious

Remark:
1: AV Emission Level= PK Emission Level+20log(dutycycle)
2: Data of measurem ent within this frequency range shown “/” in the table above means the reading of emissions are attenuated more than 20db
below the permissible limits or the field strength is too small to be measured.
3: “*” means the emission(s) appear within the restrict bands shall follow the requirement of section 15.205.

Duty Cycle =100(ms)/100 (ms) =100%
Duty Cycle Factor =20log (Duty Cycle) =0




EMC_SZ_FR_21.00 FCC                             TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 11 of 15
                                  Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                       Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0063.01




9.2 Bandwidth Measurement

Test Method

   1. Check the calibration of the measuring instrument using either an internal calibrator or a
      known signal from an external generator.
   2. Position the EUT without connection to measurement instrument. Turn on the EUT and
      connect it to measurement instrument. Then set it to any one convenient frequency within
      its operating range. Set a reference level on the measuring instrument equal to the
      highest peak value.
   3. Measure the frequency difference of two frequencies that were attenuated 20 dB from the
      reference level. Record the frequency difference as the emission bandwidth.
   4. Repeat above procedures until all frequencies measured were complete.

Limit

The bandwidth of the emission shall be no wider than 0.25% of the center frequency for
devices operating above 70MHz and below 900MHz. For devices operating above 900MHz,
the emission shall be no wider than 0.5% of the center frequency. Bandwidth is determined at
the points 20dB down from the modulated carrier.
The limit for the EUT = 0.25% * 433.925 MHz = 1084 kHz

Test Result
        Channel          20dB Bandwidth (KHz)                    99% bandwidth (KHz)                  Limit (KHz)
        1                81.04KHz                                77.86KHz                             1085KHz




EMC_SZ_FR_21.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 12 of 15
                         Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0063.01




9.3 Deactivation Time

Test Method

   1.   Place the EUT in the chamber and set it in transmitting mode.
   2.   Set center frequency of spectrum analyzer=operating frequency.
   3.   Set the spectrum analyzer as RBW=120 KHz, VBW=1MHz, Span=0Hz.
   4.   4. Repeat above procedures until all frequency measured was complete.

Limit

According to FCC Part 15.231 (a), the transmitter shall be complied the following requirements:
(√) (1) A manually operated transmitter shall employ a switch that will automatically deactivate
the transmitter within not more than 5 seconds of being released.
(2) A transmitter activated automatically shall cease transmission within 5 seconds after
activation.
(3) Periodic transmissions at regular predetermined intervals are not permitted. However, polling
or supervision transmissions, including data, to determine system integrity of transmitters used
in security or safety applications are allowed if the total duration of transmissions does not
exceed more than two seconds per hour for each transmitter. There is no limit on the number of
individual transmissions, provided the total transmission time does not exceed two seconds per
hour.

Test Result
        Channel          Frequency                               Deactivation Time                  Result
        1                433.925MHz                              252.17ms                           Pass




EMC_SZ_FR_21.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 13 of 15
                         Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0063.01



10 Test Equipment List

                                            List of Test Instruments

                Description              Manufacturer                Model no.              Serial no.          CAL. DUe DATE

       C     Signal Analyzer          Rohde & Schwarz                 FSV40                  101031                  2019-7-6
            EMI Test Receiver         Rohde & Schwarz                 ESR 26                 101269                  2019-7-6
               Trilog Super
             Broadband Test              Schwarzbeck                VULB 9163                   707                 2019-6-28
                 Antenna
              Horn Antenna            Rohde & Schwarz                 HF907                102294                   2019-6-28
      RE       Pre-amplifier          Rohde & Schwarz                 SCU 18               102230                   2019-7-6
               Pre-amplifier          Rohde & Schwarz                 SMY01              839369/005                 2019-7-6
             Signal Generator         Rohde & Schwarz                 8491A              MY39264334                 2019-7-6
            3m Semi-anechoic                                                                                        2020-7-7
                                               TDK                     9X6X6                    ----
                 chamber
                                                                                             Version                       N/A
               Test software          Rohde & Schwarz                 EMC32
                                                                                             9.15.00

C - Conducted RF tests
  • 20dB bandwidth and 99% bandwidth
  • Deactivation Time




EMC_SZ_FR_21.00 FCC                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 14 of 15
                          Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0063.01




11 System Measurement Uncertainty

For a 95% confidence level, the measurement expanded uncertainties for defined systems, in
accordance with the recommendations of ISO 17025 were:

                               System Measurement Uncertainty
                          Items                         Extended Uncertainty
       Uncertainty for Radiated Spurious Emission                                       Horizontal: 4.80dB;
                      25MHz-3000MHz                                                      Vertical: 4.87dB;
       Uncertainty for Radiated Spurious Emission                                       Horizontal: 4.59dB;
                    3000MHz-18000MHz                                                     Vertical: 4.58dB;
       Uncertainty for Radiated Spurious Emission                                       Horizontal: 5.05dB;
                   18000MHz-40000MHz                                                     Vertical: 5.04dB;
       Uncertainty for Conducted RF test with TS 8997                               RF Power Conducted: 1.16dB
                                                                                      Frequency test involved:
                                                                                          0.6×10-7 or 1%




EMC_SZ_FR_21.00 FCC                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 15 of 15
                          Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299



Document Created: 2019-03-28 16:24:34
Document Modified: 2019-03-28 16:24:34

© 2024 FCC.report