FCC part 15C test report

FCC ID: ZY4CM08

Test Report

Download: PDF

Report Number: 68.910.18.0065.01




                                                               FCC - TEST REPORT



Report Number                                          : 68.910.18.0065.01                               Date of Issue:                         May 27, 2019


Model                                                  : CM-08

Product Type                                           : Honeycomb motor

Applicant                                              : Coulisse B.V.

Address                                                : Vonderweg 48, 7468 DC Enter, THE NETHERLANDS

Production Facility                                    : Ningbo Dooya Mechanic & Electronic Technology Co., Ltd.

Address                                                : No.168 Shengguang Road, Luotuo, Zhenhai 315202 Ningbo,

                                                       : Zhejiang province, PEOPLE'S REPUBLIC OF CHINA




Test Result                                            : n Positive                    o Negative



Total pages including
Appendices                                             : 18




TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in
ISO 17025.


TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test conditions. Construction of
the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with
identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the
production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch shall have no
liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
issued reports.


This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be
reproduced except in full without our written approval




EMC_SZ_FR_21.00 FCC                                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                                 Page 1 of 18
                                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0065.01




1 Table of Contents
1      Table of Contents ........................................................................................................................................................... 2
2      Details about the Test Laboratory.................................................................................................................................... 3
3      Description of the Equipment Under Test ........................................................................................................................ 4
4      Summary of Test Standards ............................................................................................................................................ 5
5      Summary of Test Results ................................................................................................................................................ 6
6      General Remarks ............................................................................................................................................................ 7
7      Systems test configuration .............................................................................................................................................. 8
8      Test Setups ..................................................................................................................................................................... 9
9      Test Methodology......................................................................................................................................................... 10
     9.1       Conducted Emission ............................................................................................................................................. 10
     9.2       Radiated Emission ................................................................................................................................................ 13
     9.3       Bandwidth Measurement ...................................................................................................................................... 15
     9.4       Deactivation Time ................................................................................................................................................ 16
10     Test Equipment List...................................................................................................................................................... 17
11     System Measurement Uncertainty ................................................................................................................................. 18




EMC_SZ_FR_21.00 FCC                                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                                        Page 2 of 18
                                             Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                                  Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0065.01




2 Details about the Test Laboratory
Details about the Test Laboratory
Test Site 1

Company name:         TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
                      Building 12&13, Zhiheng Wisdomland Business Park,
                      Nantou Checkpoint Road 2, Nanshan District,
                      Shenzhen City, 518052,
                      P. R. China

FCC Registration      514049
Number:

Telephone:            86 755 8828 6998
Fax:                  86 755 8828 5299




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 3 of 18
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0065.01




3 Description of the Equipment Under Test

Product:                    Honeycomb motor

Model no.:                  CM-08

FCC ID:                     ZY4CM08

Rating:                     5VDC, 7W (Supplied by USB Port)
                            11.1VDC (Supplied By rechargeable Li-ion Battery)

RF Transmission             433.925MHz
Frequency:

Modulation:                 FSK

Antenna Type:               Integrated Antenna

Antenna Gain:               0.5dBi

Description of the EUT: The Equipment Under Test (EUT) is a Honeycomb motor
                        operated at 433.925MHz




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 4 of 18
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0065.01




4 Summary of Test Standards

                                         Test Standards
FCC Part 15 Subpart C       PART 15 - RADIO FREQUENCY DEVICES
10-1-2017 Edition           Subpart C - Intentional Radiators

All the test methods were according to ANSI C63.10.




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 5 of 18
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0065.01




5 Summary of Test Results

                                            Technical Requirements
   FCC Part 15 Subpart C
   Test Condition                                                                    Pages          Test Site             Test Result
   §15.207                                     Conducted emission                     10             Site 1                  Pass
                                               AC power port
   §15.205, §15.209,                           Radiated Emission,                       13            Site 1                 Pass
   15.35 (c)§15.231 (b)                        30MHz to 4.5GHz
   §15.231(c)                                  Bandwidth                                15            Site 1                 Pass
                                               Measurement
   §15.231(a) (1)                              Deactivation Time                        16            Site 1                 Pass


Note 1: N/A=Not Applicable.
Note 2: The EUT uses an integrated Antenna, which gain is 0.5dBi. In accordance to §15.203, It is
considered sufficiently to comply with the provisions of this section.




EMC_SZ_FR_21.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                    Page 6 of 18
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0065.01




6 General Remarks
Remarks

This submittal(s) (test report) is intended for FCC ID: ZY4CM08 complies with Section 15.207,
15.209, 15.231 of the FCC Part 15.

SUMMARY:

All tests according to the regulations cited on page 5 were

n - Performed

o - Not Performed

The Equipment Under Test

n - Fulfills the general approval requirements.

o - Does not fulfill the general approval requirements.


Sample Received Date:                       August 31, 2018

Testing Start Date:                         August 31, 2018

Testing End Date:                         February 27, 2019

TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch



Reviewed by:                           Prepared by:                                    Tested by:




  _______________________                   _______________________                           _______________________
      Laurent Yuan                            Mark Chen                                             Carry Cai
   EMC Project Manager                    EMC Project Engineer                                   EMC Test Engineer




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 7 of 18
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0065.01




7 Systems test configuration
Auxiliary Equipment Used during Test:

            DESCRIPTION            MANUFACTURER                    MODEL NO.(SHIELD)                     S/N(LENGTH)
                   --                          --                                --                           --




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 8 of 18
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0065.01



8 Test Setups

7.1 Radiated test setups

Below 1GHz




Above 1GHz




7.2 Conducted RF test setups


  Measuring                   EUT
  Receiver


7.3 AC Power Line Conducted Emission test setups




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 9 of 18
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0065.01



9 Test Methodology

9.1 Conducted Emission

Test Method
   1. The EUT was placed on a table, which is 0.8m above ground plane
   2. The power line of the EUT is connected to the AC mains through a Artificial Mains
      Network (A.M.N.).
   3. Maximum procedure was performed to ensure EUT compliance
   4. A EMI test receiver is used to test the emissions from both sides of AC line

Limit

                           Frequency                         QP Limit                        AV Limit
                              MHz                             dBμV                            dBμV
                           0.150-0.500                        66-56*                          56-46*
                             0.500-5                            56                              46
                              5-30                              60                              50

*Decreases with the logarithm of the frequency.




EMC_SZ_FR_21.00 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 10 of 18
                            Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                 Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0065.01




Product Type                          :    Honeycomb motor
M/N                                   :    CM-08
Operating Condition                   :    Charging+ Wireless Link
Test Specification                    :    Line
Comment                               :    5VDC (Supplied by USB Port)



                               80

                               70

                               60
               Level in dBµV




                               50

                               40

                               30

                               20

                               10

                               0
                               150k           300 400 500        800 1M             2M       3M 4M 5M 6          8 10M            20M        30M
                                                                              Frequency in Hz


Critical_Freqs
 Frequency     MaxPeak                    Average      Limit     Margin     Line     Corr.
   (MHz)        (dBµV)                     (dBµV)     (dBµV)      (dB)               (dB)
    0.222000       49.11                        ---     62.74      13.64    L1        10.2
    0.342000       42.95                        ---     59.15      16.21    L1        10.2
    0.530000       42.02                        ---     56.00      13.98    L1        10.3
    0.750000       39.67                        ---     56.00      16.33    L1        10.3
    1.602000       35.71                        ---     56.00      20.29    L1        10.3
    7.882000       32.86                        ---     60.00      27.14    L1        10.6



Remark:
*Level=Reading Level + Correction Factor
**Correction Factor=Cable Loss + LISN Factor
(The Reading Level is recorded by software which is not shown in the sheet)




EMC_SZ_FR_21.00 FCC                                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                  Page 11 of 18
                                             Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                                  Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0065.01



Product Type                          :    Honeycomb motor
M/N                                   :    CM-08
Operating Condition                   :    Charging+ Wireless Link
Test Specification                    :    Neutral
Comment                               :    5VDC (Supplied by USB Port)


                               80

                               70

                               60
               Level in dBµV




                               50

                               40

                               30

                               20

                               10

                               0
                               150k           300 400 500        800 1M             2M       3M 4M 5M 6          8 10M            20M        30M
                                                                                Frequency in Hz


Critical_Freqs
 Frequency     MaxPeak                    Average      Limit     Margin     Line     Corr.
   (MHz)        (dBµV)                     (dBµV)     (dBµV)      (dB)               (dB)
    0.218000       47.93                        ---     62.89      14.97    N         10.2
    0.386000       40.66                        ---     58.15      17.49    N         10.3
    0.534000       40.41                        ---     56.00      15.59    N         10.3
    0.650000       40.88                        ---     56.00      15.12    N         10.3
    1.402000       33.89                        ---     56.00      22.11    N         10.3
    8.006000       32.41                        ---     60.00      27.59    N         10.6



Remark:
*Level=Reading Level + Correction Factor
**Correction Factor=Cable Loss + LISN Factor
(The Reading Level is recorded by software which is not shown in the sheet)




EMC_SZ_FR_21.00 FCC                                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                  Page 12 of 18
                                             Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                                  Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0065.01


9.2 Radiated Emission

Test Method

   1: The EUT was place on a turn table which is 1.5m above ground plane for above 1GHz
   and 0.8m above ground for below 1GHz at 3 meter chamber room for test. The table was
   rotated 360 degrees to determine the position of the highest radiation.
   2: The EUT was set 3 meters away from the interference – receiving antenna, which was
   mounted on the top of a variable – height antenna tower.
   3: The height of antenna is varied from one meter to four meters above the ground to
   determine the maximum value of the field strength. Both horizontal and vertical polarizations
   of the antenna are set to make the measurement.
   4: For each suspected emission, the EUT was arranged to its worst case and then the
   antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was turned
   from 0 degrees to 360 degrees to find the maximum reading.
   5: Use the following spectrum analyzer settings According to C63.10:
   For Above 1GHz
       Span = wide enough to capture the peak level of the in-band emission and all spurious
       RBW = 1MHz, VBW≥RBW for peak measurement and VBW = 10Hz for average
       measurement, Sweep = auto, Detector function = peak, Trace = max hold.
   For Below 1GHz
   Use the following spectrum analyzer settings:
       Span = wide enough to capture the peak level of the in-band emission and all spurious
       RBW = 100 KHz, VBW≥RBW for peak measurement, Sweep = auto, Detector function =
       peak, Trace = max hold.

Limit

According to §15.231 (b), the field strength of emissions from intentional radiators operated
under this section shall not exceed the following:

                                                 Field Strength of                     Field Strength of spurious
            Fundamental frequency
                   (MHz)                      Fundamental (Microvolts                    emissions ((Microvolts
                                                      /meter)                                    /meter)
                  40.66-40.70                           2,250                                      225
                     70-130                             1,250                                      125
                    130-174                       1,250 to 3,370 *                             125 to 375 *
                    174-260                             3,750                                      375
                   260-470 √                     3,750 to 12, 500*                            375 to 1,250*
                   Above 470                           12,500                                     1,250




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 13 of 18
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0065.01



Spurious radiated emissions for transmitter
According to C63.10, if the peak (or quasi-peak) measured value complies with the average limit, it is unnecessary to perform an
average measurement, so AV emission value did not show in below table if the peak value complies with average limit.

                                                              Radiated Emissions
    Value   Emissions            E-Field          Field Average Net Field                    Limit        Margin             Emission
            Frequency            Polarity        at 3m   Factor  at 3m                                                         Type
               MHz                              dBµV/m    dB    dBµV/m                    dBµV/m
    Below 1GHz
     PK      433.925                 H           97.14         0.00          97.14         100.83           3.69           Fundamental
     AV      433.925                 H           97.14        -21.97         75.17         80.83            5.66           Fundamental
     PK      433.925                 V           83.84         0.00          83.84         100.83          16.99           Fundamental
     AV      433.925                 V           83.84        -21.97         61.87         80.83           18.96           Fundamental
     PK      867.910                 H           58.37         0.00          58.37         80.83           22.46             Spurious
     AV      867.910                 H           58.37        -21.97         36.40         60.83           24.43             Spurious
     PK      867.910                 V           49.18         0.00          49.18         80.83           31.65             Spurious
     AV      867.910                 V           49.18        -21.97         27.21         60.83           33.62             Spurious
    Above 1GHz
     PK       2603.6                 H           49.62         0.00          49.62            74           24.38              Spurious
     AV       2603.6                 H           40.69        -21.97         18.72            54           35.28              Spurious
     PK       2603.6                 V           40.39         0.00          40.39            74           33.61              Spurious
     AV       2603.6                 V           40.39        -21.97         18.42            54           35.58              Spurious

Remark:
1: AV Emission Level= PK Emission Level+20log(dutycycle)
Below 1GHz: Level=Reading Level + Correction Factor
             Correction Factor=Antenna Factor + Cable Loss
Above 1GHz: Level=Reading Level + Correction Factor
              Correction Factor=Antenna Factor + Cable Loss – Pre-amplifier
(The Reading Level is recorded by software which is not shown in the sheet)
3: Data of measurement within this frequency range shown “/” in the table above m eans the reading of emissions are attenuated more than 20db
below the permissible limits or the field strength is too small to be measured.
4: “*” means the emission(s) appear within the restrict bands shall follow the requirement of section 15.205.

Duty Cycle =7.101(ms)/100 (ms) =7.101%
Duty Cycle Factor =20log (Duty Cycle) =-21.97




EMC_SZ_FR_21.00 FCC                            TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 14 of 18
                                  Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                       Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0065.01




9.3 Bandwidth Measurement

Test Method

   1. Check the calibration of the measuring instrument using either an internal calibrator or a
      known signal from an external generator.
   2. Position the EUT without connection to measurement instrument. Turn on the EUT and
      connect it to measurement instrument. Then set it to any one convenient frequency within
      its operating range. Set a reference level on the measuring instrument equal to the
      highest peak value.
   3. Measure the frequency difference of two frequencies that were attenuated 20 dB from the
      reference level. Record the frequency difference as the emission bandwidth.
   4. Repeat above procedures until all frequencies measured were complete.

Limit

The bandwidth of the emission shall be no wider than 0.25% of the center frequency for
devices operating above 70MHz and below 900MHz. For devices operating above 900MHz,
the emission shall be no wider than 0.5% of the center frequency. Bandwidth is determined at
the points 20dB down from the modulated carrier.
The limit for the EUT = 0.25% * 433.925 MHz = 1084 kHz

Test Result
        Channel          20dB Bandwidth (KHz)                    99% bandwidth (KHz)                 Limit (KHz)
        1                81.33KHz                                79.01KHz                            1085KHz




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 15 of 18
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0065.01




9.4 Deactivation Time

Test Method

   1.   Place the EUT in the chamber and set it in transmitting mode.
   2.   Set center frequency of spectrum analyzer=operating frequency.
   3.   Set the spectrum analyzer as RBW=120 KHz, VBW=1MHz, Span=0Hz.
   4.   4. Repeat above procedures until all frequency measured was complete.

Limit

According to FCC Part 15.231 (a), the transmitter shall be complied the following requirements:
(√) (1) A manually operated transmitter shall employ a switch that will automatically deactivate
the transmitter within not more than 5 seconds of being released.
(2) A transmitter activated automatically shall cease transmission within 5 seconds after
activation.
(3) Periodic transmissions at regular predetermined intervals are not permitted. However, polling
or supervision transmissions, including data, to determine system integrity of transmitters used
in security or safety applications are allowed if the total duration of transmissions does not
exceed more than two seconds per hour for each transmitter. There is no limit on the number of
individual transmissions, provided the total transmission time does not exceed two seconds per
hour.

Test Result
        Channel          Frequency                               Deactivation Time                 Result
        1                433.925MHz                              269.57ms                          Pass




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 16 of 18
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0065.01



10 Test Equipment List

                                            List of Test Instruments

                Description              Manufacturer               Model no.              Serial no.          CAL. DUe DATE

      C      Signal Analyzer         Rohde & Schwarz                  FSV40                  101031                 2019-7-6
            EMI Test Receiver        Rohde & Schwarz                  ESR 3                  101782                 2019-7-6
                  LISN               Rohde & Schwarz                ENV4200                  100249                 2019-7-6
                  LISN               Rohde & Schwarz                 ENV432                  101318                 2019-7-6
                  LISN               Rohde & Schwarz                 ENV216                  100326                 2019-7-6
                   ISN               Rohde & Schwarz                 ENY81                   100177                 2019-7-6
                   ISN               Rohde & Schwarz               ENY81-CA6                 101664                 2019-7-6
      CE
                                                                   TK9420(VT9
            High Voltage Probe       Rohde & Schwarz                                       9420-584                2019-6-30
                                                                       420)
             RF Current Probe        Rohde & Schwarz                  EZ-17                100816                  2019-6-30
                Attenuator          Shanghai Huaxiang               TS2-26-3             080928189                 2019-7-6
                                                                                        Version9.15.0                 N/A
               Test software         Rohde & Schwarz                  EMC32
                                                                                              0
            EMI Test Receiver        Rohde & Schwarz                  ESR 26               101269                   2019-7-6
               Trilog Super
             Broadband Test              Schwarzbeck               VULB 9163                   707                 2019-6-28
                 Antenna
              Horn Antenna           Rohde & Schwarz                  HF907                102294                  2019-6-28
      RE       Pre-amplifier         Rohde & Schwarz                  SCU 18               102230                  2019-7-6
               Pre-amplifier         Rohde & Schwarz                  SMY01              839369/005                2019-7-6
             Signal Generator        Rohde & Schwarz                  8491A              MY39264334                2019-7-6
            3m Semi-anechoic                                                                                       2020-7-7
                                               TDK                     9X6X6                    ----
                 chamber
                                                                                            Version                       N/A
               Test software         Rohde & Schwarz                  EMC32
                                                                                            9.15.00

C - Conducted RF tests
  • 20dB bandwidth and 99% bandwidth
  • Deactivation Time




EMC_SZ_FR_21.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 17 of 18
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0065.01




11 System Measurement Uncertainty
For a 95% confidence level, the measurement expanded uncertainties for defined systems, in
accordance with the recommendations of ISO 17025 were:

                              System Measurement Uncertainty
                         Items                         Extended Uncertainty
                                                                              Horizontal: 4.80dB;Vertical: 4.87dB;
                                                                                       (30MHz~3GHz)
                Radiated spurious emission
                                                                              Horizontal: 4.59dB;Vertical: 4.58dB
                                                                                        3GHz~18GHz)
      Uncertainty for Conducted RF test with TS 8997                            RF Power Conducted: 1.16dB
                                                                                   Frequency test involved:
                                                                                        0.6×10-7 or 1%




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 18 of 18
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299



Document Created: 2019-06-12 10:16:09
Document Modified: 2019-06-12 10:16:09

© 2019 FCC.report
This site is not affiliated with or endorsed by the FCC