Test Report

FCC ID: ZVG2600KL

Test Report

Download: PDF
FCCID_1521452

                                                     Page: 1 of 25




                                    FCC TEST REPORT
FCC ID                   : ZVG2600KL

Applicant                 : Pelstar LLC/Health o meter® Professional Scales
Address                   : 11800 South Austin Avenue. Alsip, IL 60803 USA

Equipment Under Test (EUT) :

Product Name               : Digital Medical Scale
Model No.                  : Refers to clause 3.2 of this test report for more details

Standards                  :    FCC PART15 SUBPART B

Date of Test              :     August 4~9, 2011
Date of Issue             :     August 10, 2011

Prepared By                :    Zero Zhou/Preject Engineer

Reviewed By               :     Philo.Zhong/General Manager

Test Result :                  PASS *


                                             Prepared By:
                                Waltek Services (Shenzhen) Co., Ltd.
               1/F, Fukangtai Building, West Baima Rd., Songgang Street, Baoan District,
                                        Shenzhen 518105, China

                                              Tel :+86-755-27553488
                                              Fax:+86-755-27553868
* The sample detailed above has been tested to the requirements of Council Directives ANSI C63.4:2003.
  The test results have been reviewed against the Directives above and found to meet their essential
  requirements.




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                       Reference No.: WT11073974-E-E-F


                                                     Page:2 of 25




1 Test Summary
         Test                       Test Requirement               Test Method             Class / Severity       Result
         Radiated Emission          FCC PART 15,
                                                                ANSI C63.4: 2003           FCC Part15.109         PASS
         (30MHz to 1GHz)           SUBPART B: 2007
         Conducted Emission         FCC PART 15,
                                                                ANSI C63.4: 2003           FCC Part15.107         PASS
         (150KHz to 30MHz)         SUBPART B: 2007




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                     Reference No.: WT11073974-E-E-F


                                                                             Page:3 of 25




2         Contents
1       COVER PAGE ......................................................................................................................................................... 1

1 TEST SUMMARY........................................................................................................................................................ 2

2       CONTENTS............................................................................................................................................................. 3

3       GENERAL INFORMATION ................................................................................................................................ 4
    3.1     CLIENT INFORMATION ........................................................................................................................................... 4
    3.2     GENERAL DESCRIPTION OF E.U.T. ........................................................................................................................ 4
    3.3     DETAILS OF E.U.T................................................................................................................................................. 4
    3.4     DESCRIPTION OF SUPPORT UNITS .......................................................................................................................... 4
    3.5     STANDARDS APPLICABLE FOR TESTING ................................................................................................................ 5
    3.6     TEST FACILITY ...................................................................................................................................................... 5
    3.7     TEST LOCATION .................................................................................................................................................... 5
4       EQUIPMENT USED DURING TEST .................................................................................................................. 6

5       EMISSIONS TEST RESULTS .............................................................................................................................. 8
    5.1 CONDUCTED EMISSION DATA ............................................................................................................................... 8
       5.1.1 E.U.T. Operation ........................................................................................................................................ 8
       5.1.2 Measurement Uncertainty........................................................................................................................... 8
       5.1.3 EUT Setup................................................................................................................................................... 9
       5.1.4 Conducted Emission Test Result............................................................................................................... 10
       5.1.5 Photograph- Test Setup for Conducted Emission..................................................................................... 12
    5.2 RADIATION EMISSION DATA ............................................................................................................................... 13
       5.2.1 Measurement Uncertainty......................................................................................................................... 13
       5.2.2 EUT Setup................................................................................................................................................. 13
       5.2.3 Spectrum Analyzer Setup .......................................................................................................................... 14
       5.2.4 Test Procedure.......................................................................................................................................... 14
       5.2.5 Corrected Amplitude & Margin Calculation ............................................................................................ 14
       5.2.6 Summary of Test Results ........................................................................................................................... 15
       5.2.7 Photograph – Radiation Emission Test Setup .......................................................................................... 17
6       PHOTOGRAPHS - CONSTRUCTIONAL DETAILS...................................................................................... 18
    6.1     EUT –COMPONENTS VIEW.................................................................................................................................. 18
    6.2     EUT – OPEN VIEW .............................................................................................................................................. 18
    6.3     EUT –PCB- FRONT VIEW ................................................................................................................................... 19
    6.4     EUT – PCB-BACK VIEW..................................................................................................................................... 19
    6.5     ADAPTER – LABEL VIEW ..................................................................................................................................... 23
    6.6     ADAPTER –PCB FRONT VIEW ............................................................................................................................. 23
    6.7     ADAPTER –PCB BACK VIEW............................................................................................................................... 24
7       FCC LABEL.......................................................................................................................................................... 25




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                                                           Reference No.: WT11073974-E-E-F


                                                     Page:4 of 25




3      General Information

3.1   Client Information
      Applicant:                           Pelstar LLC/Health o meter® Professional Scales
      Address of Applicant:                11800 South Austin Avenue. Alsip, IL 60803 USA

       Manufacturer:                      GOLDEN BOW (FU YONG) MANUFACTORY
       Address of Manufacturer:           INDUSTRIAL ROAD, TANG WEI VILLAGE,FU YONG
                                          TOWN, BAO AN COUNTY,SHENZHEN, CHINA


3.2   General Description of E.U.T.

         Product Name :                  Digital Medical Scale
         Model No.    :
          Model                       customer                    Measurement range(kg or Ib)
          2650KL                      HS5096.001.00                 700LB
          2500KL                      HS5097.001.00                 1000LB
          1100KL                      HS5098.001.00                 1000LB
          2400KL                      HS5099.001.00                 800LB
          2000KL                      HS5100.001.00                 400LB
          2700KL                      HS5101.001.00                 1000LB
          2101KL                      HS5102.001.00                 1000LB
          2600KL                      HS5057.001.00                 1000LB

         Model Description:              All the models are identical in interior structure,electrical circuits,
                                         and components with different measurement range. 2600KL is the
                                         test sample.

3.3   Details of E.U.T.

         Power supply:                    DC 9V 0.5A from AC adapter(input:100-240V~, 50/60Hz)


3.4   Description of Support Units
      The EUT has been tested as independent unit.



The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                     Reference No.: WT11073974-E-E-F


                                                     Page:5 of 25




3.5    Standards Applicable for Testing
       The customer requested FCC tests for a Digital Medical Scale. The standards used were FCC
       PART 15 SUBPART B.

3.6    Test Facility
       The test facility is recognized, certified, or accredited by the following organizations:

•      IC – Registration No.: 7760A
       Waltek Services(Shenzhen) Co., Ltd. has been registered and fully described in a report filed
       with the Industry Canada. The acceptance letter from the Industry Canada is maintained in our
       files. Registration No.:7760A, August 3,2010.

•     FCC – Registration No.: 880581
       Waltek Services(Shenzhen) Co., Ltd. EMC Laboratory has been registered and fully
       described in a report filed with the (FCC) Federal Communications Commission. The
       acceptance letter from the FCC is maintained in our files. Registration 880581, May 26,2011


3.7    Test Location
        All Emission tests were performed at:
         Waltek Services(Shenzhen) Co., Ltd. at 1/F, Fukangtai Building, West Baima Rd.,Songgang
         Street, Baoan District, Shenzhen, China




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                     Reference No.: WT11073974-E-E-F


                                                      Page:6 of 25




 4      Equipment Used during Test
Equipment        Manufacturer      Equipmen                                     Cal.       Due        Cert.
                                                 Internal No    Specification                                    Uncertainty
Name             Model             t No                                         Date       Date       No
EMC              Agilent/          MY45114                                      Aug.23     Aug.23     Wws20
                                                 W2008001       9k-26.5GHz                                       ±1dB
Analyzer         E7405A            943                                          -2010      -2011      081596
Trilog           SCHWARZB          336
Broadband        ECK MESS-                                      30-3000         Aug.23     Aug.23
                                                 W2008002                                                        ±1dB
Antenne 30-      ELEKTROM/                                      MHz             -2010      -2011
3000 MHz         VULB9163
Broad-band       SCHWARZB          667                                                                           f<10
Horn Antenna     ECK MESS-                                                                                       GHz:
1-18 GHz         ELEKTROM/                                                                                       ±1dB
                                                                                Aug.23     Aug.23
                 BBHA9120D                       W2008003       1-18GHz                                          10GHz<f
                                                                                -2010      -2011
                                                                                                                 <18
                                                                                                                 GHz:
                                                                                                                 ±1.5dB
Broadband        SCHWARZB          9718-148
Preamplifier     ECK MESS-                                                      Aug.23     Aug.23
                                                 W2008004       0.5-18GHz                                        ±1.2dB
0.5-18 GHz       ELEKTROM/                                                      -2010      -2011
                 BBV 9718
10m Coaxial      SCHWARZB          -
Cable with N-    ECK MESS-
male             ELEKTROM/                                                      Aug.23     Aug.23
                                                 -              -                                                -
Connectors       AK 9515 H                                                      -2010      -2011
usable up to
18GHz,
10m 50 Ohm       SCHWARZB
Coaxial Cable    ECK MESS-
with N-plug,     ELEKTROM/
individual       AK 9513                                                        Aug.23     Aug.23
length,                                                                         -2010      -2011
usable up to
3(5)GHz,
Connector
Positioning      C&C LAB/
                                                                                N/A        N/A
Controller       CC-C-IF
Color Monitor    SUNSPO/ SP-
                 14C                                                            N/A        N/A

Test Receiver    ROHDE&SC          101155
                                                                                Aug.23     Aug.23     Wws20
                 HWARZ/                          W2005001           9k-3GHz                                      ±1dB
                                                                                -2010      -2011      080942
                 ESPI
EMI Receiver     Beijingkehuan     KH3931                                       Aug.23     Aug.23
                                                                9k-1GHz
                                                                                -2010      -2011
Two-Line V-       ROHDE&SC          100115
                                                                    50Ω/50μ       Aug.23 Aug.23 Wws20
Network           HWARZ/                          W2005002                                                       ±10%
                                                                 Η                -2010      -2011     080941
                  ENV216
V-LISN            SCHWARZB NSLK                   8128-259
                                                                 9k-30MHz
                  ECK MESS 8128                                                   Aug.23 Aug.23
                  -                                                               -2010      -2011
                  ELEKTRONI
 The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
 full, without prior written permission of the Company
 WALTEK SERVICES                                                                      Reference No.: WT11073974-E-E-F


                                                     Page:7 of 25




Equipment       Manufacturer      Equipmen                                     Cal.       Due        Cert.
                                                Internal No    Specification                                    Uncertainty
Name            Model             t No                                         Date       Date       No
                K
Absorbing       ROHDE&SC          100205        W2005003       impandance
Clamp           HWARZ/                                         50Ω             Aug.23     Aug.23     Wws20
                MDS-21                                                                                          ±1dB
                                                               loss            -2010      -2011      080943
                                                               :17 dB
10m 50 Ohm      SCHWARZB
Coaxial Cable   ECK MESS-
with N-plug,    ELEKTROM/
individual      AK 9514                                                        Aug.23     Aug.23
length,                                                                        -2010      -2011
usable up to
3(5)GHz,
Connectors
PC              Lenovo            T4900         -              -               -          -          -          -
Laptop          IBM               T30




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                       Reference No.: WT11073974-E-E-F


                                                     Page:8 of 25




5       Emissions Test Results

5.1     Conducted Emission Data
        Test Requirement:                    FCC Part15.107
        Test Method:                         ANSI C63.4:2003
        Test Result:                         PASS
        Frequency Range:                     150kHz to 30MHz
        Class:                               Class B
        Limit:                               66-56 dBμV between 0.15MHz & 0.5MHz
                                             56 dBμV between 0.5MHz & 5MHz
                                             60 dBμV between 5MHz & 30MHz
        Detector:                            Peak for pre-scan (9kHz Resolution Bandwidth)
                                             Quasi-Peak & Average if maximised peak within 6dB of
                                             Average Limit



5.1.1    E.U.T. Operation
        Operating Environment:
        Temperature:           25.5 °C
        Humidity:              51 % RH
        Atmospheric Pressure:  1012 mbar


        EUT Operation :
        The EUT was tested according to ANSI C63.4:2003. The frequency spectrum from 150kHz
        to 30MHz was investigated.
        The maximised peak emissions from the EUT was scanned and measured for both the Live
        and Neutral Lines. Quasi-peak & average measurements were performed if peak emissions
        were within 6dB of the average limit line.



5.1.2 Measurement Uncertainty
        Based on CISPR16-4-2, The Treatment of Uncertainty in EMC Measurements, the best
        estimate of the uncertainty of conducted emission measurement at Waltek Lab is +3.64dB.




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                     Reference No.: WT11073974-E-E-F


                                                     Page:9 of 25




5.1.3    EUT Setup
        The conducted emission tests were performed using the setup accordance with the ANSI
        C63.4:2003, The specification used in this report was the FCC Part15 B 15.107 limits.




         The EUT was placed on the test table in working mode connected with PC.Then the
         measurement value will show on the monitor by PC.A USB cable is used for linking
         between PC and the EUT ,but can not be used for interchanging data.




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                     Reference No.: WT11073974-E-E-F


                                                    Page:10 of 25




5.1.4    Conducted Emission Test Result

        An initial pre-scan was performed on the live and neutral lines.


        Live line:




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                     Reference No.: WT11073974-E-E-F


                                                    Page:11 of 25




Neutral line:




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                     Reference No.: WT11073974-E-E-F


                                                    Page:12 of 25




5.1.5    Photograph- Test Setup for Conducted Emission




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                     Reference No.: WT11073974-E-E-F


                                                    Page:13 of 25




5.2   Radiation Emission Data
      Test Requirement:                      FCC Part15.109
      Test Method:                           ANSI C63.4:2003
      Test Result:                           PASS
      Frequency Range:                       30MHz to 1GHz
      Measurement Distance:                  3m
      Class:                                 Class B
      Limit:                                 40.0 dBμV/m between 30MHz & 88MHz
                                             43.5 dBμV/m between 88MHz & 216MHz
                                             46.0 dBμV/m between 216MHz & 960MHz
                                             54.0 dBμV/m zbove 960MHz
       Detector:                             Peak for pre-scan (120kHz resolution bandwidth)
                                             Quasi-Peak if maximised peak within 6dB of limit


5.2.1 Measurement Uncertainty
       All measurements involve certain levels of uncertainties, especially in the field of EMC. The
       factors contributing to uncertainties are spectrum analyzer, cable loss, antenna factor
       calibration, antenna directivity, antenna factor variation with height, antenna phase center
       variation, antenna factor frequency interpolation, measurement distance variation, site
       imperfections, mismatch (average), and system repeatability.


       Based on NIS 81, The Treatment of Uncertainty in EMC Measurements, the best estimate of
       the uncertainty of a radiation emissions measurement at Waltek EMC Lab is +5.03dB.


5.2.2 EUT Setup
       The radiated emission tests were performed in the 3m Semi- Anechoic Chamber test site,
       using the setup accordance with the ANSI C63.4:2003, The specification used in this report
       was the FCC Part15 B limits.
       The EUT was placed on the test table in working mode,the worst data were shown as follow.




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                     Reference No.: WT11073974-E-E-F


                                                     Page:14 of 25




5.2.3 Spectrum Analyzer Setup
       According to FCC Part15 B Rules, the system was tested from 30 to 1000MHz.

                        Start Frequency.............................................. 30 MHz
                        Stop Frequency..............................................1000MHz
                        Sweep Speed Auto
                         IF Bandwidth................................................120 KHz
                        Video Bandwidth...........................................100KHz
                        Quasi-Peak Adapter Bandwidth .................... 120 KHz
                        Quasi-Peak Adapter Mode ............................Normal
                        Resolution Bandwidth ...................................100KHz


5.2.4 Test Procedure

       The radiated emissions test.

       Maximizing procedure was performed on the six (6) highest emissions to ensure EUT is
       compliant with all installation combinations.

       All data was recorded in the peak detection mode. Quasi-peak readings was performed only
       when an emission was found to be marginal (within -4 dBμV of specification limits), and are
       distinguished with a "Qp" in the data table.
       The EUT was under normal mode during the final qualification test and the configuration was
       used to represent the worst case results.


5.2.5 Corrected Amplitude & Margin Calculation
       The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Factor, and
       subtracting the Amplifier Gain from the Amplitude reading. The basic equation is as follows:


             Corr. Ampl. = Indicated Reading + Antenna Factor + Cable Factor - Amplifier Gain


       The “Margin” column of the following data tables indicates the degree of compliance with
       the applicable limit. For example, a margin of -7dBμV means the emission is 7dBμV below
       the maximum limit for Class B. The equation for margin calculation is as follows:
       Margin = Corr. Ampl. – Class B Limit


The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                     Reference No.: WT11073974-E-E-F


                                                    Page:15 of 25




5.2.6 Summary of Test Results
       According to the data in this section, the EUT complied with the FCC Part15 B standards.

       Antenna polarization:Horizontal




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                     Reference No.: WT11073974-E-E-F


                                                    Page:16 of 25




Antenna polarization:Vertical




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                     Reference No.: WT11073974-E-E-F


                                                    Page:17 of 25




5.2.7 Photograph – Radiation Emission Test Setup




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                     Reference No.: WT11073974-E-E-F


                                                    Page:18 of 25




6      Photographs - Constructional Details

6.1    EUT –Front View




6.2    EUT – Back View




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                     Reference No.: WT11073974-E-E-F


                                                    Page:19 of 25




6.3    EUT –Control Panel- Front View




6.4    EUT –Control Panel -Back View




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                     Reference No.: WT11073974-E-E-F


                                                    Page:20 of 25




6.5    EUT –PCB1- Front View




6.6    EUT –PCB1 -Back View




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                     Reference No.: WT11073974-E-E-F


                                                    Page:21 of 25




6.7    EUT –PCB2- Front View




6.8    EUT –PCB2 -Back View




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                     Reference No.: WT11073974-E-E-F


                                                    Page:22 of 25




6.9    EUT –PCB3- Front View




6.10 EUT –PCB3 -Back View




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                     Reference No.: WT11073974-E-E-F


                                                    Page:23 of 25




6.11 Adapter – Appearance View




6.12 Adapter –PCB Front View




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                     Reference No.: WT11073974-E-E-F


                                                    Page:24 of 25




6.13 Adapter –PCB Back View




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                     Reference No.: WT11073974-E-E-F


                                                    Page:25 of 25




7      FCC Label
       This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
       conditions:(1)this device may not cause harmful interference,and (2) this device must accept
       any interference received, including interference that may cause undesired operation
       The Label must not be a stick-on paper. The Label on these products must be permanently
       affixed to the product and readily visible at the time of purchase and must last the expected
       lifetime of the equipment not be readily detachable.




                                                     FCC ID: ZVG2600KL
                                                     This device complies with Part 15 of the FCC Rules. Operation
                                                     is subject to the following two conditions:(1)this device may not
                                                     cause harmful interference,and (2) this device must accept any
                                                     interference received, including interference that may cause
                                                     undesired operation




The results shown in this test report refer only to the sample(s) tested , This Test report cannot be reproduced, except in
full, without prior written permission of the Company
WALTEK SERVICES                                                                                                          Reference No.: WT11073974-E-E-F



Document Created: 2011-08-11 13:56:19
Document Modified: 2011-08-11 13:56:19

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC