Circuit Description

FCC ID: ZVG2600KL

Operational Description

Download: PDF
FCCID_1521446

2600KL Circuit Description


Theory of the Electronic Scale as below:
Once placing an objects on the platform, pressure pass to the sensor and make the
sensor transformed, so that the impedance changed. In the mean time, using the
excitation voltage to output an analog signal. The signal will be outputted to the
converter by using the amplifier and converter will convert the signal to be the digital
signal and pass the signal to the CPU for calculation. CPU,employed a 8MHz crystal,
will follow with the command and the application to output the signal to the display.

Key function as following:
Key function specification (9keys, not including PRINT):
1    ON/OFF;
2   HOLD/RELEASE/RIGHT;
3   REWEIGH;
4   ENTER;
5   KG/LB/UP;
6   ZERO;
7   TARE/PRETARE;
8   BMI;
9   RECALL