Test Report

FCC ID: ZUE0550

Test Report

Download: PDF
FCCID_2519671

                                                                                                              ONE WORLD         OUR APPROVAL




    Test report

     274831-1R1TRFWL
     Date of issue:    January 12, 2015




     Applicant:
     Standard Innovation Corporation
     Product:
     We-Vibe Classic Massager
     Model:
     0550
     FCC ID:                              IC Registration number:
     ZUE0550                              9804A-0550

     Specifications:
      FCC 47 CFR Part 15 Subpart C, §15.249
                Operation in the 902–928 MHz, 2400–2483.5 MHz, 5725–5875 MHz and 24.0–24.25 GHz

      RSS-210, Issue 8, December 2010, Annex 2.9
                Devices operating in frequency bands 902–928, 2400–2483.5 and 5725–5875 MHz for any application




www.nemko.com                                                                     Nemko Canada Inc., a testing laboratory, is     SCC Accredited
                                                                                                                                      LAB
                                                                                     accredited by the Standards Council of
                                                                                    Canada. The tests included in this report
                                                                                   are within the scope of this accreditation
                                                                                                                                        LAB
                                                                                                                                   Accrédité CCN
                                                                    FCC 15.249 and RSS-210 A2.9.docx; Date: September 2013                         TM


Test location

Company name:        Nemko Canada Inc.
Address:             303 River Road
City:                Ottawa
Province:            Ontario
Postal code:         K1V 1H2
Country:             Canada
Telephone:           +1 613 737 9680
Facsimile:           +1 613 737 9691
Toll free:           +1 800 563 6336
Website:             www.nemko.com
Site number:         FCC: 176392; IC: 2040A-4 (3 m semi anechoic chamber)




Tested by:           David Duchesne, Senior EMC/Wireless Specialist
Reviewed by:         Andrey Adelberg, Senior Wireless/EMC Specialist
Date:                January 12, 2015

Signature:




Limits of responsibility

Note that the results contained in this report relate only to the items tested and were obtained in the period between the date of initial receipt of samples
and the date of issue of the report.
This test report has been completed in accordance with the requirements of ISO/IEC 17025. All results contain in this report are within Nemko Canada’s
ISO/IEC 17025 accreditation.
Copyright notification

Nemko Canada Inc. authorizes the applicant to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only.
Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties.
Nemko Canada Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report.
© Nemko Canada Inc.




 Report reference ID: 274831-1R1TRFWL                                                                                                     Page 2 of   21


Table of Contents
Section 1          Report summary ................................................................................................................................................................................. 4
  1.1       Applicant .................................................................................................................................................................................................................. 4
  1.2       Manufacturers .......................................................................................................................................................................................................... 4
  1.3       Test specifications .................................................................................................................................................................................................... 4
  1.4       Statement of compliance ......................................................................................................................................................................................... 4
  1.5       Exclusions ................................................................................................................................................................................................................. 4
  1.6       Test report revision history ...................................................................................................................................................................................... 4
Section 2          Summary of test results ....................................................................................................................................................................... 5
  2.1       FCC Part 15 Subpart C – general requirements, test results ..................................................................................................................................... 5
  2.2       FCC Part 15 Subpart C – Intentional Radiators, test results ...................................................................................................................................... 5
  2.3       IC RSS-GEN, Issue 4, test results ............................................................................................................................................................................... 5
  2.4       RSS-210, Issue 8, test results .................................................................................................................................................................................... 5
Section 3          Equipment under test (EUT) details ..................................................................................................................................................... 6
  3.1       Sample information .................................................................................................................................................................................................. 6
  3.2       EUT information ....................................................................................................................................................................................................... 6
  3.3       Technical information .............................................................................................................................................................................................. 6
  3.4       Product description and theory of operation ........................................................................................................................................................... 6
  3.5       EUT exercise details.................................................................................................................................................................................................. 6
  3.6       EUT setup Figure ...................................................................................................................................................................................................... 7
  3.7       EUT sub assemblies .................................................................................................................................................................................................. 7
Section 4          Engineering considerations .................................................................................................................................................................. 8
  4.1       Modifications incorporated in the EUT .................................................................................................................................................................... 8
  4.2       Technical judgment .................................................................................................................................................................................................. 8
  4.3       Deviations from laboratory tests procedures ........................................................................................................................................................... 8
Section 5          Test conditions .................................................................................................................................................................................... 9
  5.1       Atmospheric conditions ........................................................................................................................................................................................... 9
  5.2       Power supply range .................................................................................................................................................................................................. 9
Section 6          Measurement uncertainty ................................................................................................................................................................. 10
  6.1       Uncertainty of measurement ................................................................................................................................................................................. 10
Section 7          Test equipment ................................................................................................................................................................................. 11
  7.1       Test equipment list ................................................................................................................................................................................................. 11
Section 8          Testing data ...................................................................................................................................................................................... 12
  8.1       FCC Clause 15.207(a) and RSS-Gen Clause 8.8 AC power line conducted emissions limits ..................................................................................... 12
  8.2       FCC Clause 15.215© Emission bandwidth and RSS-Gen Clause 6.6 Occupied bandwidth ...................................................................................... 15
  8.3       FCC Clause 15.249(a) and RSS-210 A2.9(a) Field strength of fundamental and harmonics emissions .................................................................... 17
  8.4       FCC Clause 15.249(d) and RSS-210 A2.9(b) Spurious emissions (except for harmonics) ........................................................................................ 19
Section 9          Block Figures of test set-ups .............................................................................................................................................................. 21
  9.1       Radiated emissions set-up...................................................................................................................................................................................... 21
  9.2       Conducted emissions set-up .................................................................................................................................................................................. 21




 Report reference ID: 274831-1R1TRFWL                                                                                                                                                                              Page 3 of   21


Section 1                  Report summary




Section 1              Report summary

1.1       Applicant

Company name :                      Standard Innovation Corporation
Address :                           Suite 330, 1130 Morrison Drive
City :                              Ottawa
Province/State :                    Ontario
Postal/Zip code :                   K2H 9N6
Country :                           Canada

1.2       Manufacturers

Company name                         Able-One Technology Ltd                                 Info Tronic International Ltd.
Company address                      9/F, Guang Ying Building, No. 88 Di Hao Road            528 Jinbi Rd., Biling Village, Pingshan Town, Longgang District
                                     ZhangMuTao Town, Dong Guan, China                       Shenzhen City, Guangdong Province, China



1.3       Test specifications

FCC 47 CFR Part 15, Subpart C, Clause 15.249      Operation in the 902–928 MHz, 2400–2483.5 MHz, 5725–5875 MHz and 24.0–24.25 GHz
RSS-210, Issue 8 Annex 2.9                        Devices operating in frequency bands 902–928, 2400–2483.5 and 5725–5875 MHz for any application

1.4       Statement of compliance

In the configuration tested, the EUT was found compliant.
Testing was completed against all relevant requirements of the test standard. Results obtained indicate that the product under test complies in full with the
requirements tested. The test results relate only to the items tested.
See “Summary of test results” for full details.

1.5       Exclusions

None

1.6       Test report revision history

      Revision #       Details of changes made to test report
         TRF           Original report issued
         R1            Correction to model.




 Report reference ID: 274831-1R1TRFWL                                                                                                       Page 4 of   21


Section 2:                   Summary of test results




Section 2                Summary of test results

2.1       FCC Part 15 Subpart C – general requirements, test results

Part                   Test description                                                                                                                   Verdict
§15.207(a)             Conducted limits                                                                                                                    Pass
§15.215(c)             20 dB emission bandwidth                                                                                                            Pass



2.2       FCC Part 15 Subpart C – Intentional Radiators, test results

Part                   Test description                                                                                                                   Verdict
§15.249(a)             Field strength of fundamental and harmonics emissions                                                                               Pass
§15.249(d)             Spurious emissions (except harmonics)                                                                                               Pass



2.3       IC RSS-GEN, Issue 4, test results

Clause                 Test description                                                                                                                  Verdict
6.6                    Occupied bandwidth                                                                                                                  Pass
7.1.2                  Receiver Radiated Limits                                                                                                       Not applicable
7.1.3                  Receiver Conducted Limits                                                                                                      Not applicable
8.8                    AC power lines conducted emission limits                                                                                            Pass
Note: 1 According to sections 5.2 and 5.3 of RSS-Gen, Issue 4 the EUT does not have a stand-alone receiver neither scanner receiver, therefore exempt from receiver requirements.



2.4       RSS-210, Issue 8, test results

Part                   Test description                                                                                                                   Verdict
§A2.9a                 Field strength of fundamental and harmonics emissions                                                                               Pass
§A2.9b                 Spurious emissions (except harmonics)                                                                                               Pass




 Report reference ID: 274831-1R1TRFWL                                                                                                                       Page 5 of   21


Section 3:               Equipment under test (EUT) details




Section 3             Equipment under test (EUT) details

3.1     Sample information

Receipt date                            December 8, 2014
Nemko sample ID number                  1



3.2     EUT information

Product name                            We-Vibe Classic Massager
Model                                   0550



3.3     Technical information

Operating band                          2400–2483.5 MHz
Operating frequency                     2402–2480 MHz
Modulation type                         GFSK
Occupied bandwidth (99 %)               1.145 MHz
Emission designator                     F1D
Power requirements                      Lithium ion re-chargeable internal battery. Charging voltage 5 VDC (via USB interface of a charger base)
                                        Internal wire antenna
Antenna information
                                        The EUT uses a unique antenna coupling/ non-detachable antenna to the intentional radiator.



3.4     Product description and theory of operation

The EUT is a personal massager. The EUT communicate with remote controller at 2.4 GHz ISM frequency band. The EUT uses 3 advertising channels for BLE
protocol.



3.5     EUT exercise details

EUT was specially modified for RF testing to transmit continuously on the low, mid and high channels. Freshly charged battery was used throughout the
assessment.




 Report reference ID: 274831-1R1TRFWL                                                                                                     Page 6 of   21


Section 3:             Equipment under test (EUT) details




3.6     EUT setup Figure




                                         USB cable 1.2m         Charging Base                 Massager
                AC-DC adapter MN#
               RIM-C0004ADUUS-001




               AC input


                                                                                                         Support

                                                                          Remote

                                                              Figure 3.6-1: Setup diagram



3.7     EUT sub assemblies


                                                            Table 3.7-1: EUT sub assemblies

Description                                    Brand name                        Model/Part number         Serial number
Charger base                                   We-Vibe                           0537                      –
USB Power supply                               RIM                               RIM-C0004ADUUS-001        –




 Report reference ID: 274831-1R1TRFWL                                                                              Page 7 of   21


Section 4:               Engineering consideration




Section 4            Engineering considerations

4.1     Modifications incorporated in the EUT

There were no modifications performed to the EUT during this assessment.

4.2     Technical judgment

None

4.3     Deviations from laboratory tests procedures

No deviations were made from laboratory procedures.




 Report reference ID: 274831-1R1TRFWL                                      Page 8 of   21


Section 5:                Test conditions




Section 5             Test conditions

5.1     Atmospheric conditions

Temperature               15–30 °C
Relative humidity         20–75 %
Air pressure              860–1060 mbar
When it is impracticable to carry out tests under these conditions, a note to this effect stating the ambient temperature and relative humidity during the
tests shall be recorded and stated.

5.2     Power supply range

The normal test voltage for equipment to be connected to the mains shall be the nominal mains voltage. For the purpose of the present document, the
nominal voltage shall be the declared voltage, or any of the declared voltages ±5 %, for which the equipment was designed.




 Report reference ID: 274831-1R1TRFWL                                                                                                       Page 9 of   21


Section 6:               Measurement uncertainty




Section 6            Measurement uncertainty

6.1     Uncertainty of measurement

Nemko Canada Inc. has calculated measurement uncertainty and is documented in EMC/MUC/001 “Uncertainty in EMC measurements.” Measurement
uncertainty was calculated using the methods described in CISPR 16-4 Specification for radio disturbance and immunity measuring apparatus and methods –
Part 4: Uncertainty in EMC measurements; as well as described in UKAS LAB34: The expression of Uncertainty in EMC Testing. Measurement uncertainty
calculations assume a coverage factor of K=2 with 95% certainty.




 Report reference ID: 274831-1R1TRFWL                                                                                                 Page 10 of   21


Section 7:                   Test equipment




Section 7                Test equipment

7.1       Test equipment list

Equipment                                     Manufacturer             Model no.    Asset no.   Cal cycle     Next cal.
3 m EMI test chamber                          TDK                      SAC-3        FA002047    1 year        Mar. 18/15
Power source                                  California Instruments   5001ix       FA002494    1 year        Oct. 22/14
Receiver/spectrum analyzer                    Rohde & Schwarz          ESU 26       FA002043    1 year        Dec. 23/14
Bilog antenna (20–3000 MHz)                   Sunol                    JB3          FA002108    1 year        Mar. 12/15
50 Ω coax cable                               C.C.A.                   None         FA002555    1 year        June 23/15
50 Ω coax cable                               Huber + Suhner           None         FA002074    1 year        June 23/15
Horn antenna (1–18 GHz)                       EMCO                     3115         FA000825    1 year        Mar. 10/15
Pre-amplifier (1–18 GHz)                      JCA                      JCA118-503   FA002091    1 year        June 23/15
LISN                                          Rohde & Schwarz          ENV216       FA002023    1 year        Dec. 28/14
Power source                                  California Instruments   3001i        FA001021    1 year        June 27/15
50 Ω coax cable                               C.C.A.                   None         FA002556    1 year        June 23/15
Receiver/spectrum analyzer                    Rohde & Schwarz          ESU 40       FA002071    1 year        Mar. 20/15
Note: NCR - no calibration required




 Report reference ID: 274831-1R1TRFWL                                                                       Page 11 of   21


Section 8                 Testing data
Test name                 FCC Clause 15.207(a) and RSS-Gen Clause 8.8 AC power line conducted emissions limits
Specification             FCC Part 15 Subpart C and RSS-Gen, Issue 4



Section 8             Testing data

8.1       FCC Clause 15.207(a) and RSS-Gen Clause 8.8 AC power line conducted emissions limits


 8.1.1      Definitions and limits

FCC:
Except as shown in paragraphs (b) and (c) of this section, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the
radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies, within the band 150 kHz to 30 MHz, shall not exceed
the limits in the following table, as measured using a 50 μH/50 Ω line impedance stabilization network (LISN). Compliance with the provisions of this
paragraph shall be based on the measurement of the radio frequency voltage between each power line and ground at the power terminal. The lower limit
applies at the boundary between the frequency ranges.

RSS-Gen Clause 8.8 AC Power Line Conducted Emissions Limits for Licence-Exempt Radio Apparatus
A radio apparatus that is designed to be connected to the public utility (AC) power line shall ensure that the radio frequency voltage, which is conducted back
onto the AC power line on any frequency or frequencies within the band 150 kHz-30 MHz, shall not exceed the limits in Table 8.1–1 below.
Unless the requirements applicable to a given device state otherwise, for any radio apparatus equipped to operate from the public utility AC power supply
either directly or indirectly (such as with a battery charger), the radio frequency voltage of emissions conducted back onto the AC power lines in the
frequency range of 0.15 MHz to 30 MHz shall not exceed the limits shown in Table 8.1–1 below. The more stringent limit applies at the frequency range
boundaries.


                                                              Table 8.1-1: Conducted emissions limit

            Frequency of emission,                                                             Conducted limit, dBµV
                     MHz                                              Quasi-peak                                                Average
                   0.15–0.5                                            66 to 56*                                                56 to 46*
                     0.5–5                                                 56                                                       46
                     5–30                                                  60                                                       50
Note: * - Decreases with the logarithm of the frequency.



 8.1.2      Test summary


Verdict                               Pass
Test date                             December 11, 2014                                       Temperature                            24.4 °C
Test engineer                         David Duchesne                                          Air pressure                           991.5 mbar
Test location                         Ottawa                                                  Relative humidity                      32.1 %




 Report reference ID: 274831-1R1TRFWL                                                                                                          Page 12 of   21


Section 8                 Testing data
Test name                 FCC Clause 15.207(a) and RSS-Gen Clause 8.8 AC power line conducted emissions limits
Specification             FCC Part 15 Subpart C and RSS-Gen, Issue 4




 8.1.3      Observations, settings and special notes

Port under test                      AC port of AC-to-USB adapter
EUT setup configuration              Table top
Measurement details                  A preview measurement was generated with the receiver in continuous scan mode. Emissions detected within 6 dB or
                                     above limit were re-measured with the appropriate detector against the correlating limit and recorded as the final
                                     measurement.

Receiver settings:
Resolution bandwidth                 9 kHz
Video bandwidth                      30 kHz
Detector mode                        Peak and Average (preview measurement); Quasi-peak and Average (final measurement)
Trace mode                           Max Hold
Measurement time                     100 ms (preview measurement); 1000 ms (final measurement)




 Report reference ID: 274831-1R1TRFWL                                                                                                 Page 13 of   21


Section 8                                           Testing data
Test name                                           FCC Clause 15.207(a) and RSS-Gen Clause 8.8 AC power line conducted emissions limits
Specification                                       FCC Part 15 Subpart C and RSS-Gen, Issue 4




 8.1.4                  Test data


                                         75

                                         70

                                         65

                                         60

                                         55

                                         50

                                         45
                        Level in dBµV




                                         40

                                         35

                                         30

                                         25

                                         20

                                         15

                                         10

                                             5

                                             0
                                             150k          300    400    500       800    1M             2M           3M    4M    5M       6       8    10M    20M           30M

                                                                                                    Frequency in Hz

    120V AC /60H z, Ph ase (Ch arg in g State )
                         C ISPR 22 M ain s Q P C lass B
                         C ISPR 22 M ain s A V C lass B
                         Pre view Re sult 1-PK+
                         Pre view Re sult 2-A VG



                                                                                 Plot 8.1-1: Conducted emissions on phase line



                                        75

                                        70

                                        65

                                        60

                                        55

                                        50

                                        45
             Level in dBµV




                                        40

                                        35

                                        30

                                        25

                                        20

                                        15

                                        10

                                        5

                                        0
                                        150k              300    400    500      800     1M            2M            3M    4M    5M    6       8       10M    20M       30M

                                                                                                   Frequency in Hz

    120V AC 60Hz, Ne u tral (Ch arg ing )
              CISPR 22 M ain s Q P Class B
              CISPR 22 M ain s A V Class B
              Pre view Re sult 1-PK+
              Pre view Re sult 2-A VG



                                                                                Plot 8.1-2: Conducted emissions on neutral line




 Report reference ID: 274831-1R1TRFWL                                                                                                                           Page 14 of   21


Section 8                 Testing data
Test name                 FCC Clause 15.215(c) Emission Bandwidth and RSS Gen Clause 6.6 Occupied bandwidth
Specification             FCC Part 15 Subpart C and RSS-Gen, Issue 4



8.2       FCC Clause 15.215(c) Emission bandwidth and RSS-Gen Clause 6.6 Occupied bandwidth


 8.2.1      Definitions and limits

FCC Part 15.215(c)
Intentional radiators operating under the alternative provisions to the general emission limits, as contained in §§15.217 through 15.257 and in Subpart E of
this part, must be designed to ensure that the 20 dB bandwidth of the emission, or whatever bandwidth may otherwise be specified in the specific rule
section under which the equipment operates, is contained within the frequency band designated in the rule section under which the equipment is
operated. The requirement to contain the designated bandwidth of the emission within the specified frequency band includes the effects from frequency
sweeping, frequency hopping and other modulation techniques that may be employed as well as the frequency stability of the transmitter over expected
variations in temperature and supply voltage. If frequency stability is not specified in the regulations, it is recommended that the fundamental emission be
kept within at least the central 80 % of the permitted band in order to minimize the possibility of out-of-band operation.
RSS-Gen Clause 6.6 Occupied bandwidth
When an occupied bandwidth value is not specified in the applicable RSS, the transmitted signal bandwidth to be reported is to be its 99 percent emission
bandwidth, as calculated or measured.
The transmitter shall be operated at its maximum carrier power measured under normal test conditions.
The span of the analyzer shall be set to capture all products of the modulation process, including the emission skirts. The resolution bandwidth shall be set
to as close to 1 percent of the selected span as is possible without being below 1 percent. The video bandwidth shall be set to 3 times the resolution
bandwidth. Video averaging is not permitted. Where practical, a sampling detector shall be used since a peak or, peak hold, may produce a wider
bandwidth than actual.
The trace data points are recovered and are directly summed in linear terms. The recovered amplitude data points, beginning at the lowest frequency, are
placed in a running sum until 0.5 percent of the total is reached and that frequency recorded. The process is repeated for the highest frequency data points.
This frequency is recorded.
The span between the two recorded frequencies is the occupied bandwidth.


 8.2.2      Test summary


Verdict                               Pass
Test date                             December 17, 2014                                      Temperature                           25.1 °C
Test engineer                         David Duchesne                                         Air pressure                          995.0 mbar
Test location                         Ottawa                                                 Relative humidity                     35.3 %



 8.2.3      Observations, settings and special notes

Spectrum analyzer settings:
Resolution bandwidth:           100 kHz
Video bandwidth:                300 kHz
Detector mode:                  Peak
Trace mode:                     Max Hold
Function:                       20 dB BW (for FCC); 99 % bandwidth (for IC)




 Report reference ID: 274831-1R1TRFWL                                                                                                        Page 15 of   21


Section 8                              Testing data
Test name                              FCC Clause 15.215(c) Emission Bandwidth and RSS Gen Clause 6.6 Occupied bandwidth
Specification                          FCC Part 15 Subpart C and RSS-Gen, Issue 4




 8.2.4            Test data

                                                     * RBW   100 kHz   Marker 1 [T1 ]                                                                            * RBW   100 kHz   Marker 1 [T1 ]
                                                        VBW 300 kHz                -8.00 dBm                                                                      VBW 300 kHz                  -8.02 dBm
       Ref   10 dBm              Att    35 dB           SWT 2.5 ms          2.402283654 GHz                        Ref   10 dBm               Att   15 dB         SWT 2.5 ms             2.402280449 GHz

       10                                                              ndB [T1]    20.00 dB                        10                                                              OBW   1.145833333 MHz
                                                                       BW   1.258012821 MHz                                                                                        Temp 1 [T1 OBW]
                                                                       Temp 1 [T1 ndB]           A                                                                                           -22.61 dBm      A
       0                                                                                                           0
                                                                                  -27.96 dBm                                                                                             2.401503205 GHz
1 PK                                                1                                                       1 PK                                                  1
                                                                            2.401426282 GHz                                                                                        Temp 2 [T1 OBW]
VIEW                                                                                                        MAXH
       -10                                                             Temp 2 [T1 ndB]                             -10                                                                       -25.81 dBm
                                                                                  -27.97 dBm                                                                                             2.402649038 GHz
                                                                            2.402684295 GHz
       -20                                                                                                         -20                              T1
                                                                                                                                                                          T2
                                  T1                         T2
                                                                                                 PS                                                                                                          PS
       -30                                                                                                         -30




       -40                                                                                                         -40


                                                                                                 3DB                                                                                                         3DB
       -50                                                                                       AC                -50                                                                                       AC




       -60                                                                                                         -60




       -70                                                                                                         -70




       -80                                                                                                         -80



       -90                                                                                                         -90

       Center   2.40224359 GHz                  500 kHz/                          Span   5 MHz                     Center   2.402080128 GHz                 500 kHz/                         Span    5 MHz




Date: 17.DEC.2014     09:46:37                                                                              Date: 17.DEC.2014     09:41:27




                            Plot 8.2-1: 20 dB bandwidth example                                                                   Plot 8.2-2: 99 % occupied bandwidth example



                                                                                         Table 8.2-1: 20 dB bandwidth results

 Lower 20 dBc Freq.,                     Lower 20 dBc Freq.                   Lower margin, MHz              Upper 20 dBc Freq.,                     Upper 20 dBc Freq.                    Upper margin, MHz
        MHz                                 limit, MHz                                                              MHz                                 limit, MHz
      2401.42                                 2400.00                                      1.42                   2480.67                                 2483.50                                      2.83


                                                                                          Table 8.2-2: 99% bandwidth results

                                                 Frequency                                                                                               99 % bandwidth
                                                   (MHz)                                                                                                      (MHz)
                                                    2402                                                                                                      1.145
                                                    2440                                                                                                      1.137
                                                    2480                                                                                                      1.098




 Report reference ID: 274831-1R1TRFWL                                                                                                                                                               Page 16 of     21


Section 8                  Testing data
Test name                  FCC Clause 15.249(b) and RSS Gen 7.2.5 Field strength of fundamental and harmonics emissions
Specification              FCC Part 15 Subpart C and RSS-210 A2.9



8.3         FCC Clause 15.249(a) and RSS-210 A2.9(a) Field strength of fundamental and harmonics emissions


    8.3.1     Definitions and limits

In addition to the provisions of §15.205 and RSS Gen the field strength of emissions from intentional radiators operated under this section shall not exceed
the following:
                                                               Table 8.3-1: Field strength limits

  Fundamental frequencies                         Field strength of fundamental                                 Field strength of harmonics
             (MHz)                            (mV/m)                      (dBµV/m)                         (µV/m)                      (dBµV/m)
            902–928                              50                           94                             500                            54
         2400–2483.5                             50                           94                             500                            54
          5725–5875                              50                           94                             500                            54
          24.0–24.25*                           250                          108                            2500                            68
Note: * - Only FCC band.

(e) As shown in §15.35(b), for frequencies above 1000 MHz, the field strength limits in paragraphs (a) and (b) of this section are based on average limits.
However, the peak field strength of any emission shall not exceed the maximum permitted average limits specified above by more than 20 dB under any
condition of modulation. For point-to-point operation under paragraph (b) of this section, the peak field strength shall not exceed 2500 millivolts/meter (128
dBµV/m) at 3 meters along the antenna azimuth.



    8.3.2     Test summary


Verdict                                Pass
Test date                              December 18, 2014                                     Temperature                          26.2 °C
Test engineer                          David Duchesne                                        Air pressure                         998.7 mbar
Test location                          Ottawa                                                Relative humidity                    33.8 %



    8.3.3     Observations, settings and special notes


                                                         th
      The spectrum was searched from 2.4 GHz to the 10 harmonic at a distance of 3 m.
     The test was performed with vertical and horizontal antenna polarizations and the EUT was measured on three orthogonal axis, only the highest
      emissions were reported.

Spectrum analyzer/receiver settings:
Resolution bandwidth:          1 MHz
Video bandwidth:               3 MHz
Detector mode:                 Peak
Trace mode:                    Max Hold
Average measurements:          Duty cycle/average factor was used for calculation of the average level.




    Report reference ID: 274831-1R1TRFWL                                                                                                    Page 17 of   21


Section 8                                  Testing data
Test name                                  FCC Clause 15.249(b) and RSS Gen 7.2.5 Field strength of fundamental and harmonics emissions
Specification                              FCC Part 15 Subpart C and RSS-210 A2.9




 8.3.4               Test data, continued

Duty cycle correction factor measurement:

                                                       RBW 1 MHz      Marker 1 [T1 ]                                                                                RBW 1 MHz         Delta 2 [T1 ]
                                                       VBW   3 MHz              -50.65 dBm                                                                          VBW   3 MHz                   0.22 dB
         Ref   -20 dBm               Att    5 dB       SWT 100 ms           128.205128 µs                              Ref   -20 dBm              Att    5 dB       SWT 300 µs              201.442308 µs

         -20                                                          Delta 2 [T1 ]                                    -20                                                            Marker 1 [T1 ]
                                                                                 -0.30 dB                                                                                                       -53.16 dBm
                                                                            83.173077 ms     A                                                                                                1.538462 µs    A
         -30                                                                                                           -30

1 PK *                                                                                                        1 PK *
VIEW                                                                                         TRG              VIEW                                                                                           TRG
         -40                                                                                                           -40


               1                                                                2
         -50                                                                                                             1
                                                                                                                       -50                                                        2




         -60                                                                                                           -60



                   TRG -68 dBm                                                                                                  TRG -68 dBm
         -70                                                                                                           -70


                                                                                             3DB                                                                                                             3DB
         -80                                                                                                           -80




         -90                                                                                                           -90




         -100                                                                                                          -100




         -110                                                                                                          -110



         -120                                                                                                          -120

         Center 2.425 GHz                          10 ms/                                                              Center 2.425 GHz                         30 µs/




Date: 20.SEP.2013        15:47:28   Plot 8.3-1: 100 ms transmissions                                          Date: 20.SEP.2013             Plot 8.3-2: Single transmission duration
                                                                                                                                       15:49:03




Duty cycle calculation: 20 × log10 (Tx100 ms / 100 ms) = 20 × log10 (2 × 201.4 µs / 100 ms) = −47.89 dB


                                                                     Table 8.3-2: Field strength of fundamental measurement results

                                                      Peak field                                                                                                                         Average
                           Frequency,                                      Peak limit,                                         Duty cycle                  Average field                                           Margin,
  Channel                                              strength,                                   Margin, (dB)                                                                           limit,
                             (MHz)                                         (dBµV/m)                                           factor, (dB)              strength, (dBµV/m)                                          (dB)
                                                      (dBµV/m)                                                                                                                          (dBµV/m)
       Low                       2402                    90.57                114.00                  23.43                      -47.89                         42.68                     94.00                     51.32
       Mid                       2440                    87.71                114.00                  26.29                      -47.89                         39.82                     94.00                     54.18
       High                      2480                    85.27                114.00                  28.73                      -47.89                         37.38                     94.00                     56.62
Note: Field strength includes correction factor of antenna, cable loss, amplifier, and attenuators where applicable. Average field strength was calculated as follows:
Peak field strength (dBµV/m) + duty cycle factor (dB).


                                                                      Table 8.3-3: Field strength of harmonics measurement results

                                                      Peak field                                                                                                                         Average
                           Frequency,                                      Peak limit,                                         Duty cycle                  Average field                                           Margin,
  Channel                                              strength,                                   Margin, (dB)                                                                           limit,
                             (MHz)                                         (dBµV/m)                                           factor, (dB)              strength, (dBµV/m)                                          (dB)
                                                      (dBµV/m)                                                                                                                          (dBµV/m)
       Low                       4804                    57.25                 74.00                  16.75                      -47.89                          9.36                     54.00                     44.64
       Mid                       4880                    58.94                 74.00                  15.06                      -47.89                         11.05                     54.00                     42.95
       High                      4960                    59.23                 74.00                  14.77                      -47.89                         11.34                     54.00                     42.66
Note: Field strength includes correction factor of antenna, cable loss, amplifier, and attenuators where applicable. Average field strength was calculated as follows:
Peak field strength (dBµV/m) + duty cycle factor (dB).




 Report reference ID: 274831-1R1TRFWL                                                                                                                                                                 Page 18 of   21


Section 8                 Testing data
Test name                 FCC Clause 15.249(d) and RSS 210 A2.9 Spurious emissions (except for harmonics)
Specification             FCC Part 15 Subpart C and RSS-210 A2.9



8.4       FCC Clause 15.249(d) and RSS-210 A2.9(b) Spurious emissions (except for harmonics)


 8.4.1      Definitions and limits

Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated by at least 50 dB below the level of the fundamental
or to the general radiated emission limits in FCC §15.209 and RSS-Gen, whichever is the lesser attenuation.

                                                        Table 8.4-1: Field strength of spurious emissions

             Frequency                                                  Field strength                                       Measurement distance
               (MHz)                                    (µV/m)                                (dBµV/m)                              (m)
               30–88                                      100                                    40.0                                3
               88–216                                     150                                    43.5                                3
              216–960                                     200                                    46.0                                3
             above 960                                    500                                    54.0                                3
Notes:
   In the emission table above, the tighter limit applies at the band edges.
   For frequencies above 1 GHz the limit on peak RF emissions is 20 dB above the maximum permitted average emission limit applicable to the
    equipment under test.


 8.4.2      Test summary


Verdict                              Pass
Test date                            December 18, 2014                                       Temperature                        26.2 °C
Test engineer                        David Duchesne                                          Air pressure                       998.7 mbar
Test location                        Ottawa                                                  Relative humidity                  33.8 %



 8.4.3      Observations, settings and special notes

                                                   th
The spectrum was searched from 30 MHz to the 10 harmonic at a distance of 3 m.
The test was performed with vertical and horizontal antenna polarizations and the EUT was measured on three orthogonal axis, only the highest emissions
were reported.
For duty cycle factor calculation please refer to section 8.3.


Spectrum analyzer/receiver settings for frequencies below 1 GHz:
Resolution bandwidth:          120 kHz
Video bandwidth:               300 kHz
Detector mode:                 Quasi-Peak
Trace mode:                    Max Hold

Spectrum analyzer/receiver settings for frequencies above 1 GHz:
Resolution bandwidth:          1 MHz
Video bandwidth:               3 MHz
Detector mode:                 Peak
Trace mode:                    Max Hold
Average measurements:          Duty cycle/average factor was used for calculation of the average level.




 Report reference ID: 274831-1R1TRFWL                                                                                                     Page 19 of   21


Section 8                                Testing data
Test name                                FCC Clause 15.249(d) and RSS 210 A2.9 Spurious emissions (except for harmonics)
Specification                            FCC Part 15 Subpart C and RSS-210 A2.9




 8.4.4             Test data

                                                        * RBW   1 MHz           Marker 2 [T1 ]                                                                                    * RBW   1 MHz   Marker 2 [T1 ]
                                                         VBW 3 MHz                        69.24 dBµV                                                                               VBW 3 MHz                62.69 dBµV
       Ref    100 dBµV           * Att    0 dB           SWT 2.5 ms                  2.400000000 GHz                              Ref   100 dBµV           * Att    0 dB           SWT 2.5 ms          2.483500000 GHz

        100                                                                     Marker 1 [T1 ]                                    100                                                             Marker 1 [T1 ]
                                                                                          89.33 dBµV                                                                                                        85.66 dBµV
                                                                            1
                                                                                     2.402307692 GHz      A                                                                                            2.479782051 GHz      A
        90                                                                                                                        90        1

1 PK                                                                                                                       1 PK
MAXH                                                                                                                       VIEW
        80                                                                                                                        80


                 D1 74 dBµV                                                                                                                D1 74 dBµV
                                                   2                                                      TDS                                                                                                               TDS
        70                                                                                                                        70
                                                                                                                                                                             2
                                                                                                          PS                                                                                                                PS
        60                                                                                                                        60




        50                                                                                                                        50


                                                                                                          3DB                                                                                                               3DB
        40                                                                                                AC                      40                                                                                        AC




        30                                                                                                                        30




        20                                                                                                                        20




        10                                                                                                                        10

                                                   F1                                                                                                                        F1
        0                                                                                                                         0

        Center   2.4 GHz                         1 MHz/                                 Span     10 MHz                           Center   2.4835 GHz                      1 MHz/                         Span     10 MHz




Date: 18.DEC.2014     14:36:54                                                                                             Date: 18.DEC.2014    14:40:14




                           Plot 8.4-1: Lower band edge measurement                                                                                 Plot 8.4-2: Upper band edge measurement



                                                                        Table 8.4-2: Field strength of spurious emissions measurement results

                                                        Peak field                                                                                                                                   Average
                           Frequency,                                                Peak limit,                                         Duty cycle                   Average field                                               Margin,
  Channel                                                strength,                                              Margin, (dB)                                                                          limit,
                             (MHz)                                                   (dBµV/m)                                           factor, (dB)               strength, (dBµV/m)                                              (dB)
                                                        (dBµV/m)                                                                                                                                    (dBµV/m)
       Low                    2400.0                       69.24                         74.00                      4.76                   -47.89                           21.35                     54.00                        32.65
       High                   2483.5                       62.69                         74.00                     11.31                   -47.89                           14.80                     54.00                        39.20
Note: Field strength includes correction factor of antenna, cable loss, amplifier, and attenuators where applicable. Average field strength was calculated as follows:
Peak field strength (dBµV/m) + duty cycle factor (dB).




 Report reference ID: 274831-1R1TRFWL                                                                                                                                                                            Page 20 of       21


Section 9:            Block diagrams of test set-ups




Section 9          Block Figures of test set-ups

9.1     Radiated emissions set-up



                                                 Radio absorbing material
                                                                                                          Antenna
                                                                                                           mast



                                                                     Test
                                                                   antenna




                                                                                                                       4m




                                                       3m



                                                                     Test
                                EUT                                antenna

                                  Non-
                               conducting
                                 table                                                                                1m
                    0.8 m

                                                                Metal ground
                                                                   plane
                              Turn table

                                                                                          Receiver




9.2     Conducted emissions set-up


                                                                                                      Vertical ground plane
                                                                                                        40 cm from EUT


                                                                                             EUT
                                                                               0.8 m
                                 Power supply
                                                                                                      Non-
                                                                     LISN                          conducting
                                                                                                      table         0.8 m


                                                                                       Horizontal ground plane
                                                        Receiver




 Report reference ID: 274831-1R1TRFWL                                                                                         Page 21 of   21



Document Created: 2015-01-12 14:48:38
Document Modified: 2015-01-12 14:48:38

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC