Applicant‘s declaration concerning RF Radiation Exposure



We hereby indicate that the product
Product description: High Power Compact AC Wi—Fi Range Extender
Model No: REC1SA


The equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled
environment. The integralaritennas used for this transmitter must not be co—located or
operating in conjunction with any other antenna or transmitter within the host device.

A safety statement concerning minimum separation distances from enclosure ofthe
Product : High Power Compact AC Wi—Fi Range Extender
will be integrated in the user‘s manual to provide end—users with transmitter operating
conditions for satisfying RF exposure compliance.

The appropriate information can be drawn from the test report no: W6M21401—13774—C—1
and the accompanying calculations.



Company: Amped Wireless
Address: 13089 Peyton Dr. #C307 Chino Hills California 91709 United States


Date: 2014/02/06


Sigywr( —2

Jason    en
CEO
Amped Wireless


Registration number: W6M21401-13774-C-1
FCC ID: ZTT-REC15A
3.2    Equivalent isotropic radiated power

FCC Rule: 15.247(b)(3)
EIRP = max. conducted output power + antenna gain

5.8GHz:802.11a
EIRP = 22.78 dBm + 2 dBi
     = 24.78 dBm
5.8GHz:802.11n(20MHz), 802.11n(40MHz)
EIRP = 22.71 dBm + 2 dBi
     = 24.71 dBm
5.8GHz:802.11ac
EIRP = 23.23 dBm + 2 dBi
     = 25.23 dBm
2.4GHz:802.11b/g
EIRP = 25.62 dBm + 2 dBi
     = 27.62 dBm
2.4GHz: 802.11n(20MHz), 802.11n(40MHz)
EIRP = 21.41 dBm + 2 dBi
     = 23.41 dBm


Limit: EIRP = +36 dBm                for Antenna gain <6dBi

Test equipment used: ETSTW-RE 055

3.3    RF Exposure Compliance Requirements

FCC OET Bulletin 65 Edition 97.01 determines the equations for predicting RF fields and applicable
limits.
The prediction for power density in the far-field but will over-predict power density in the near field,
where it could be used for walking a “worst case” or conservative prediction.
                                                   PG
                                              S = ---------
                                                   4πR2
S – Power Density
P – Output power ERP
R – Distance
D – Cable Loss
AG – Antenna Gain

5.8GHz:802.11a
        Item                       Unit                   Value                   Remarks
          P                        mW                    189.6706                 Peak value
          D                        dB
         AG                        dBi                        2
          G                                                1.5849              Calculated Value
          R                        cm                        20                 Assumed value
          S                      mW/cm2                    0.0598              Calculated value




Worldwide Testing Services(Taiwan) Co., Ltd.                                          Page 25 of 83


Registration number: W6M21401-13774-C-1
FCC ID: ZTT-REC15A
5.8GHz:802.11n(20MHz), 802.11n(40MHz)
        Item                  Unit                     Value                 Remarks
          P                   mW                      186.6380               Peak value
          D                    dB
         AG                    dBi                        2
          G                                            1.5849             Calculated Value
          R                    cm                        20                Assumed value
          S                 mW/cm2                     0.0588             Calculated value

5.8GHz:802.11ac
         Item                  Unit                    Value                 Remarks
           P                   mW                     210.3778               Peak value
           D                   dB
          AG                   dBi                        2
           G                                           1.5849             Calculated Value
           R                   cm                        20                Assumed value
           S                 mW/cm2                    0.0663             Calculated value
802.11b/g
         Item                  Unit                    Value                 Remarks
           P                   mW                     364.7539               Peak value
           D                   dB
          AG                   dBi                        2
           G                                           1.5849             Calculated Value
           R                   cm                        20                Assumed value
           S                 mW/cm2                    0.1150             Calculated value
2.4G:802.11n(20MHz), 802.11n(40MHz)
         Item                  Unit                    Value                 Remarks
           P                   mW                     138.3566               Peak value
           D                   dB
          AG                   dBi                        2
           G                                           1.5849             Calculated Value
           R                   cm                        20                Assumed value
           S                 mW/cm2                    0.0436             Calculated value

Limits:
                     Limit for General Population / Uncontrolled Exposure
                    Frequency                                    Power Density
                      (MHz)                                        (mW/cm2)
                  1500 – 100.000                                     1.0