I19Z61557-SEM01_SAR_Rev0_7

FCC ID: ZNFX540EMW

RF Exposure Info

Download: PDF
FCCID_4462402

Dipole Calibration for Body Tissue/Pin=100mW, dist=10mm, £=5300 MHz/Zoom Scan,
dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 68.18 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 29.0 W/kg
SAR(I g) =7.52 W/kg; SAR(10 g) = 2.13 W/kg
Maximum value of SAR (measured) = 17.4 W/kg

Dipole Calibration for Body Tissue/Pin=100mW, dist=10mm, £=5500 MHz/Zoom Scan,
dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 69.45 V/m; Power Drift = 0.00 dB
Peak SAR (extrapolated) = 32.7 W/kg
SAR(I g) = 8 W/kg; SAR(10 g) = 2.23 W/kg
Maximum value of SAR (measured) = 19.1 W/kg

Dipole Calibration for Body Tissue/Pin=100mW, dist=10mm, £=5600 MHz/Zoom Scan,
dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 68.13 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 32.9 W/kg
SAR(1 g) =7.87 W/kg; SAR(10 g) = 2.22 W/kg
Maximum value of SAR (measured) = 18.8 W/kg

Dipole Calibration for Body Tissue/Pin=100mW, dist=10mm, £=5750 MHz/Zoom Scan,
dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 67.49 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 34.1 W/kg
SAR(1 g) = 7.79 W/kg; SAR(10 g) = 2.18 W/kg
Maximum value of SAR (measured) = 19.0 W/kg

Dipole Calibration for Body Tissue/Pin=100mW, dist=10mm, £=5800 MHz/Zoom Scan,
dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 66.59 V/m; Power Drift =0.01 dB
Peak SAR (extrapolated) = 32.0 W/kg
SAR(I g) =7.51 W/kg; SAR(10 g) = 2.09 W/kg
Maximum value of SAR (measured) = 18.0 W/kg




Certificate No: D5GHzV2—1060_Jul19           Page 20 of 23


        —12.00


        —18.00


        —24.00


        —30.00
                   0 dB = 18.0 W/kg = 12.55 dBW/kg




Certificate No: D5GHzV2—1060_Jul19            Page 21 of 23


)
(I
     Impedance Measurement Plot for Body TSL (5200, 5250, 5300, 5500, 5600 MHz)


               File    View   Channel       Sweep Calibration   Trace Scale Marker System Window Help
                                                                                                        5.200000 GHz      48.986 0
                                                                                                            5.4607 pF    —5.6049 N
                                                                                                        5.250000 GHz      47.977 0
                                                                                                            14.071 pF    —2.1544 N1
                                                                                                        5.300000 GHz      46.926 a
                                                                                                            9.9366 pF    30221 0
                                                                                                        5500000 GHz       50.168
                                                                                                            13.131 pF    22038 n
                                                                                                        5.600000 GHz      55.522 0
                                                                                                            27.781pH    97751 m0




                              Ch1Aug= 20
                      Ch1: Start 5.00000 GHa     ———                                                              Stop £.00000 GHz


                                                                                                                              T7

                                                                                                                 GHz    —29.089 dB




                      00       ChiAvg=
                      Ch1: Start 5.00000 GHz

                 State        —_Cai:—cBir   0o {cCuiron                             Avg=20 Delay                        LCL




     Certificate No: D5GHzV2—1060_Jul19                             Page 22 of 23


                   ®




I||I>
    TTL                                                                                                           ty o     n — 9    ~>     > —




(       Impedance Measurement Plot for Body TSL (5750, 5800 MHz)



                  File     View    Channel Sweep    Calibration Trace     Scale   Marker   System Window   Help
                                                                                                                   5.750000 GHz      52.337 A
                                                                                                                       22.141pH    799.92m0
                                                                                                                   5.900000 GHz      §2.094 N
                                                                                                                       14.931 pF    —1.8378 a




                                  Ch1Aug= 20
                         Ch1 : Start 5,00000 GHa   ——                                                                        Stop 6.00000 GHz

                    to.00
                    5.00
                                  _____|                                                                           5.{50000 GHz
                                                                                                                      oncos on

                    0.00
                    F5.00
                    F10.00
                    F15.00
                    F20.00

                    F25.00
                    F30.00
                    F35.00
                    +40.00        Ch 1 Avg= |20
                        Ch1 : Start 5.00000 GHa    ——                                                                        Stop £.00000 GHz


                                  CH 1:                        C*1—Port




        Certificate No: D5GHzV2—1060_Jul19                              Page 23 of 23


                                                                     No.I19Z61557-SEM01
                                                                        Page 188 of 192


ANNEX I        Sensor Triggering Data Summary




                                                 .

According to the above description, this device was tested by the manufacturer to determine the
SAR sensor triggering distances for the rear and bottom edge of the device. The measured power
state within ±5mm of the triggering points (or until touching the phantom) is included for rear and
each applicable edge.

To ensure all production units are compliant it is necessary to test SAR at a distance 1mm less
than the smallest distance from the device and SAR phantom with the device at maximum output
power without power reduction.




                                                                 ©Copyright. All rights reserved by CTTL.


                                                                             No.I19Z61557-SEM01
                                                                                Page 189 of 192

We tested the power and got the different proximity sensor triggering distances for front, rear and
bottom edge. But the manufacturer has declared 2mm is the most conservative triggering distance
for main antenna. So base on the most conservative triggering distance of 2mm, additional SAR
measurements were required at 1mm from the highest SAR position.

Front
Moving device toward the phantom:
                                                The power state
         Distance
                           7            6          5          4          3         2        1          0
           [mm]
           Main
                       Normal        Normal     Normal      Normal     Normal    Low       Low     Low
          antenna


Moving device away from the phantom:
                                                The power state
         Distance
                       0         1          2           3         4          5         6           7
           [mm]
          Main
                      Low       Low     Normal     Normal     Normal    Normal     Normal        Normal
         antenna


Rear
Moving device toward the phantom:
                                                The power state
         Distance
                            7           6           5         4          3        2         1          0
           [mm]
           Main
                       Normal         Normal     Normal     Normal    Normal     Low       Low     Low
          antenna


Moving device away from the phantom:
                                                The power state
         Distance
                       0         1          2           3         4          5         6           7
           [mm]
          Main
                      Low       Low     Normal     Normal     Normal    Normal     Normal        Normal
         antenna


Bottom Edge
Moving device toward the phantom:
                                                The power state
         Distance
                            7           6           5         4          3        2         1          0
           [mm]
           Main
                       Normal         Normal     Normal     Normal    Normal     Low       Low     Low
          antenna



                                                                        ©Copyright. All rights reserved by CTTL.


                                                                     No.I19Z61557-SEM01
                                                                        Page 190 of 192


Moving device away from the phantom:
                                           The power state
         Distance
                       0      1        2         3           4      5          6          7
           [mm]
          Main
                      Low    Low    Normal    Normal   Normal    Normal     Normal     Normal
         antenna

The influence of table tilt angles to proximity sensor triggering is determined by positioning each
edge that contains a transmitting antenna, perpendicular to the flat phantom, at the smallest sensor
triggering test distance by rotating the device around the edge next to the phantom in ≤ 10°
increments until the tablet is ±45°or more from the vertical position at 0°.




                             The Front evaluation for main antenna




                              The rear evaluation for main antenna
                                                                 ©Copyright. All rights reserved by CTTL.


                                                                    No.I19Z61557-SEM01
                                                                       Page 191 of 192




                          The bottom edge evaluation for main antenna
Based on the above evaluation, we come to the conclusion that the sensor triggering is not released
and normal maximum output power is not restored within the ±45°range at the smallest sensor
triggering test distance declared by manufacturer.




                                                                ©Copyright. All rights reserved by CTTL.


                                          No.I19Z61557-SEM01
                                             Page 192 of 192


ANNEX J   Accreditation Certificate




                                      ©Copyright. All rights reserved by CTTL.



Document Created: 2019-09-25 16:24:11
Document Modified: 2019-09-25 16:24:11

© 2024 FCC.report