I19Z61557-SEM01_SAR_Rev0_6

FCC ID: ZNFX540EMW

RF Exposure Info

Download: PDF
FCCID_4462401

Measurement Conditions
    DASY system configuration, as far as not given on page 1.
      DASY Version                                              DASYS                              V52.10.2
      Extrapolation                                   Advanced Extrapolation
      Phantom                                       Modular Flat Phantom V5.0
      Distance Dipole Center — TSL                              10 mm                             with Spacer
     Zoom Scan Resolution                         dx, dy = 4.0 mm, dz =1.4 mm         Graded Ratio = 1.4 (Z direction)
                                                        5200    MHz + 1   MHz
                                                        5250    MHz +1    MHz
                                                        5300    MHz + 1   MHz
      Frequency                                         5500    MHz + 1   MHz
                                                        5600    MHz + 1   MHz
                                                        5750    MHz + 1   MHz
                                                        5800    MHz + 1   MHz



Head TSL parameters at 5200 MHz
   The following parameters and calculations were applied.
                                                                Temperature       Permittivity         Conductivity
      Nominal Head TSL parameters                                  22.0 °C            36.0              4.66 mho/m
      Measured Head TSL parameters                              (22.0 + 0.2) °C    35.5 16 %         4.46 mho/m + 6 %
      Head TSL temperature change during test                      <0.5 °C

SAR result with Head TSL at 5200 MHz

      SAR averaged over 1 cm* (1 g) of Head TSL                  Condition
      SAR measured                                        100 mW input power                     8.06 W/kg
      SAR for nominal Head TSL parameters                    normalized to 1W          80.3 W/kg * 19.9 % (k=2)

      SAR averaged over 10 cm* (10 g) of Head TSL                condition
      SAR measured                                        100 mW input power                     2.32 Wikg
      SAR for nominal Head TSL parameters                    normalized to 1W          23.0 W/kg * 19.5 % (k=2)




Certificate No: D5GHzV2—1060_Jul19                    Page 3 of 23




                                                                                  n un en n mn n e ewne e menener e mev wn n


                                                                                                                      wo cce w on

                                                                                                   wmyy     rvxe vn       r ui




Head TSL parameters at 5250 MHz
   The following parameters and calculations were applied.
                                                               Temperature          Permittivity          Conductivity
     Nominal Head TSL parameters                                  22.0 °C               35.9               4.71 mho/m
      Measured Head TSL parameters                             (22.0 + 0.2) °C       35.5 26 %         4.51 mho/m + 6 %
      Head TSL temperature change during test                     «05 °C                 ~——                   ==—

SAR result with Head TSL at 5250 MHz

     SAR averaged over 1 cm* (1 g) of Head TSL                  Condition
     SAR measured                                        100 mW input power                     8.07 W/kg
     SAR for nominal Head TSL parameters                     normalized to 1W            80.4 Wikg + 19.9 % (k=2)

      SAR averaged over 10 cm* (10 g) of Head TSL                condition
      SAR measured                                       100 mW input power                      2.33 W/kg
      SAR for nominal Head TSL parameters                    normalized to 1W             23.2 Wikg * 19.5 % (k=2)


Head TSL parameters at 5300 MHz
   The following parameters and calculations were applied.
                                                               Temperature          Permittivity          Conductivity
      Nominal Head TSL parameters                                 22.0 °C               35.9               4.76 mho/m
      Measured Head TSL parameters                             (22.0 £ 0.2) °C       35.4 +6 %         4.56 mho/m + 6 %
      Head TSL temperature change during test                     <0.5 °C

SAR result with Head TSL at 5300 MHz

      SAR averaged over 1 cm* (1 g) of Head TSL                 Condition
      SAR measured                                       100 mW input power                        8.23 W/kg
      SAR for nominal Head TSL parameters                    normalized to 1W             82.0 W/kg * 19.9 %(k=2)

      SAR averaged over 10 cm* (10 g) of Head TSL                condition
      SAR measured                                       100 mW input power                      2.37 Wikg
      SAR for nominal Head TSL parameters                    normalized to 1W             23.5 Wikg + 19.5 % (k=2)




Certificate No: D5GHzV2—1060_Jul19                   Page 4 of 23




                                                                                 Eo cpyeagie s ragr cez n nenever n vzne wny   vee e k.


                                                                                     «ow se e n se ne n w nz         n en an w

                                                                                                y         esns sn        avk




Head TSL parameters at 5500 MHz
   The following parameters and calculations were applied.
                                                               Temperature       Permittivity           Conductivity
     Nominal Head TSL parameters                                  22.0°C              35.6               4.96 mho/m
     Measured Head TSL parameters                              (22.0 + 0.2) °C    35.1 +6 %          4.76 mho/m + 6 %
     Head TSL temperature change during test                      <0.5 °C

SAR result with Head TSL at 5500 MHz

     SAR averaged over 1 cm* (1 g) of Head TSL                  Condition
     SAR measured                                        100 mW input power                   8.51 Wikg
     SAR for nominal Head TSL parameters                     normalized to 1W          84.7 Wikg + 19.9 % (k=2)

     SAR averaged over 10 cm* (10 g) of Head TSL                 condition
     SAR measured                                        100 mW input power                   2.43 W/kg
     SAR for nominal Head TSL parameters                     normalized to 1W          24.2 Wikg * 19.5 % (k=2)


Head TSL parameters at 5600 MHz
   The following parameters and calculations were applied.
                                                               Temperature       Permittivity           Conductivity
      Nominal Head TSL parameters                                 22.0 °C             35.5               5.07 mho/m
     Measured Head TSL parameters                              (22.0 + 0.2) °C    35.0 +6 %          4.86 mho/m + 6 %
      Head TSL temperature change during test                     <0.5 °C


SAR result with Head TSL at 5600 MHz

     SAR averaged over 1 cm* (1 g) of Head TSL                  Condition
      SAR measured                                       100 mW input power                     8.49 W/kg
      SAR for nominal Head TSL parameters                    normalized to 1W          84.5 Wikg + 19.9 % (k=2)

      SAR averaged over 10 cm* (10 g) of Head TSL                condition
      SAR measured                                       100 mW input power                     2.43 W/kg
      SAR for nominal Head TSL parameters                    normalized to 1W          24.1 Wikg * 19.5 %(k=2)




Certificate No: D5GHzV2—1060_Jul19                   Page 5 of 23




                                                                                 t acnge en e e rrggr en e ns ner e neve weg n + n


                                                                                     «ow se e n se ne n w nz         n en an w

                                                                                                mg y      6k w se        k vk




Head TSL parameters at 5750 MHz
   The following parameters and calculations were applied.
                                                               Temperature       Permittivity           Conductivity
     Nominal Head TSL parameters                                  22.0 °C             35.4               5.22 mho/m
     Measured Head TSL parameters                              (22.0 + 0.2) °C    34.8 +6 %          5.02 mho/m + 6 %
     Head TSL temperature change during test                      <0.5 °C

SAR result with Head TSL at 5750 MHz

     SAR averaged over 1 cm* (1 g) of Head TSL                  Condition
     SAR measured                                        100 mW input power                   8.08 Wikg
     SAR for nominal Head TSL parameters                     normalized to 1W          80.4 Wikg + 19.9 % (k=2)

     SAR averaged over 10 cm* (10 g) of Head TSL                condition
      SAR measured                                       100 mW input power                   2.31 W/kg
      SAR for nominal Head TSL parameters                    normalized to 1W          23.0 W/kg + 19.5 % (k=2)

Head TSL parameters at 5800 MHz
   The following parameters and calculations were applied.
                                                               Temperature       Permittivity           Conductivity
      Nominal Head TSL parameters                                 22.0 °C             35.3               5.27 mho/m
      Measured Head TSL parameters                             (22.0 + 0.2) °C    34.7 26 %          5.07 mho/m + 6 %
      Head TSL temperature change during test                     <0.5 °C

SAR result with Head TSL at 5800 MHz

      SAR averaged over 1 cm* (1 g) of Head TSL                 Condition
      SAR measured                                       100 mW input power                     8.14 W/kg
      SAR for nominal Head TSL parameters                    normalized to 1W          80.9 W/kg * 19.9 % (k=2)

      SAR averaged over 10 cm‘ (10 g) of Head TSL                condition
      SAR measured                                       100 mW input power                     2.30 W/kg
      SAR for nominal Head TSL parameters                    normalized to 1W          22.9 W/kg * 19.5 % (k=2)




Certificate No: D5GHzV2—1060_Jul19                   Page 6 of 23




                                                                                 t acnge en e e rrggr en e ns ner e neve weg n + n


Body TSL parameters at 5200 MHz
   The following parameters and calculations were applied.
                                                               Temperature       Permittivity         Conductivity
     Nominal Body TSL parameters                                  22.0 °C           49.0               5.30 mho/m
     Measured Body TSL parameters                              (22.0 + 0.2) °C   47.3 16 %          5.43 mho/m + 6 %
     Body TSL temperature change during test                      <0.5 °C                                   «++


SAR result with Body TSL at 5200 MHz

     SAR averaged over 1 cm* (1 g) of Body TSL                  Condition
     SAR measured                                        100 mW input power                     741 W/kg
     SAR for nominal Body TSL parameters                     normalized to 1W        73.6 W/kg + 19.9 % (k=2)

     SAR averaged over 10 cm* (10 g) of Body TSL                condition
      SAR measured                                       100 mW input power                 2.08 W/kg
      SAR for nominal Body TSL parameters                    normalized to 1W        20.6 Wikg * 19.5 % (k=2)


Body TSL parameters at 5250 MHz
   The following parameters and calculations were applied.
                                                               Temperature       Permittivity         Conductivity
      Nominal Body TSL parameters                                 22.0 °C           48.9               5.36 mho/m
      Measured Body TSL parameters                             (22.0 + 0.2) °C   47.2 +6 %          5.49 mho/m + 6 %
      Body TSL temperature change during test                     <0.5 °C

SAR result with Body TSL at 5250 MHz

      SAR averaged over 1 cm* (1 g) of Body TSL                 Condition
      SAR measured                                       100 mW input power                     7.67 Wikg
      SAR for nominal Body TSL parameters                    normalized to 1W         76.2 Wikg * 19.9 % (k=2)

      SAR averaged over 10 cm* (10 g) of Body TSL                condition
      SAR measured                                       100 mW input power                     2.15 W/kg
      SAR for nominal Body TSL parameters                    normalized to 1W         21.3 Wikg * 19.5 % (k=2)




Certificate No: D5GHzV2—1060_Jul19                   Page 7 of 23


Body TSL parameters at 5300 MHz
   The following parameters and calculations were applied.
                                                               Temperature         Permittivity           Conductivity
      Nominal Body TSL parameters                                 22.0 °C              48.9                5.42 mho/m
      Measured Body TSL parameters                             (22.0 + 0.2) °C      47.1 16 %           5.56 mho/m + 6 %
      Body TSL temperature change during test                     <0.5 °C


SAR result with Body TSL at 5300 MHz

      SAR averaged over 1 cm* (1 g) of Body TSL                 Condition
      SAR measured                                       100 mW input power                        7.52 Wi/kg
      SAR for nominal Body TSL parameters                    normalized to 1W           74.7 Wikg * 19.9 % (k=2)

      SAR averaged over 10 cm* (10 g) of Body TSL               condition
      SAR measured                                       100 mW input power                    2.13 W/kg
      SAR for nominal Body TSL parameters                    normalized to 1W           21.1 Wikg £ 19.5 % (k=2)

Body TSL parameters at 5500 MHz
   The following parameters and calculations were applied.
                                                               Temperature          Permittivity          Conductivity
      Nominal Body TSL parameters                                 22.0 °C              48.6                5.65 mho/m
      Measured Body TSL parameters                             (22.0 + 0.2) °C      46.7 +6 %           5.83 mho/m + 6 %
      Body TSL temperature change during test                     <0.5 °C

SAR result with Body TSL at 5500 MHz

      SAR averaged over 1 cm* (1 g) of Body TSL                 Condition
      SAR measured                                       100 mW input power                        8.00 W/kg
      SAR for nominal Body TSL parameters                    normalized to 1W           79.5 W/kg + 19.9 % (k=2)


      SAR averaged over 10 cm* (10 g) of Body TSL                condition
      SAR measured                                       100 mW input power                        2.23 W/kg
      SAR for nominal Body TSL parameters                    normalized to 1W           22.1 Wikg + 19.5 % (k=2)




Certificate No: D5GHzV2—1060_Jul19                   Page 8 of 23




                                                                                 C o epegrsgme n m rngrrve n e e e e en e n es


()
~
S
Body TSL parameters at 5600 MHz
   The following parameters and calculations were applied.


     Nominal Body TSL parameters
     Measured Body TSL parameters
                                                               Temperature
                                                                  22.0 °C
                                                               (22.0 + 0.2) °C
                                                                                  Permittivity
                                                                                      48.5
                                                                                  46.6 +6 %
                                                                                                        Conductivity
                                                                                                         5.77 mho/m
                                                                                                      5.97 mho/m + 6 %
     Body TSL temperature change during test                      <0.5 °C                                     «en


SAR result with Body TSL at 5600 MHz

     SAR averaged over 1 cm* (1 g) of Body TSL                  Condition
     SAR measured                                        100 mW input power                      7.87 Wi/kg
      SAR for nominal Body TSL parameters                    normalized to 1W          78.2 Wikg * 19.9 % (k=2)

     SAR averaged over 10 cm* (10 g) of Body TSL                 condition
      SAR measured                                       100 mW input power                   2.22 Wikg
     SAR for nominal Body TSL parameters                     normalized to 1W          22.0 Wikg # 19.5 % (k=2)

Body TSL parameters at 5750 MHz
   The following parameters and calculations were applied.
                                                               Temperature        Permittivity          Conductivity
      Nominal Body TSL parameters                                 22.0 °C             48.3               5.94 mho/m
      Measured Body TSL parameters                             (22.0 + 0.2) °C    46.3 +6 %           6.17 mho/m + 6 %
      Body TSL temperature change during test                     <0.5 °C


SAR result with Body TSL at 5750 MHz

      SAR averaged over 1 cm* (1 g) of Body TSL                 Condition
      SAR measured                                       100 mW input power                      7.79 Wikg
      SAR for nominal Body TSL parameters                    normalized to 1W          77.4 Wikg * 19.9 % (k=2)

      SAR averaged over 10 cm* (10 g) of Body TSL                condition
      SAR measured                                       100 mW input power                   2.18 W/kg
      SAR for nominal Body TSL parameters                    normalized to 1W          21.5 Wikg * 19.5 % (k=2)




Certificate No: D5GHzV2—1060_Jul19                   Page 9 of 23




                                                                                 =ooma n n n e n n n cez snn ner n neve meg n ns


Body TSL parameters at 5800 MHz
   The following parameters and calculations were applied.
                                                               Temperature       Permittivity         Conductivity
      Nominal Body TSL parameters                                 22.0 °C           48.2               6.00 mho/m
      Measured Body TSL parameters                             (22.0 + 0.2) °C   46.2 £ 6 %         6.24 mho/m + 6 %
      Body TSL temperature change during test                     <0.5 °C            ~——

SAR result with Body TSL at 5800 MHz

      SAR averaged over 1 cm* (1 g) of Body TSL                 Condition
      SAR measured                                       100 mW input power                     7.51 W/kg
      SAR for nominal Body TSL parameters                    normalized to 1W        74.6 W/kg x 19.9 % (k=2)


      SAR averaged over 10 cm* (10 g) of Body TSL                condition
      SAR measured                                       100 mW input power                     2.09 W/kg
      SAR for nominal Body TSL parameters                    normalized to 1W        20.7 Wikg + 19.5 %(k=2)




Certificate No: D5GHzV2—1060_Jul19                   Page 10 of 23


—mm»..__>
i‘/"/‘/,                                                                    ~3g—   _2 _   _—_
prir




   Appendix (Additional assessments outside the scope of SCS 0108)

   Antenna Parameters with Head TSL at 5200 MHz

        Impedance, transformed to feed point                 48.7 Q — 5.5 jQ
        Return Loss                                            — 24.9 dB

   Antenna Parameters with Head TSL at 5250 MHz

        Impedance, transformed to feed point                 48.6 Q — 4.0 jQ
        Return Loss                                             —27.5 dB


   Antenna Parameters with Head TSL at 5300 MHz

        Impedance, transformed to feed point                 47.7 Q — 3.3 jQ
        Return Loss                                             —27.7 dB


   Antenna Parameters with Head TSL at 5500 MHz

         Impedance, transformed to feed point                50.9 Q — 3.9 jQ
         Return Loss                                            —28.2 dB


   Antenna Parameters with Head TSL at 5600 MHz

         Impedance, transformed to feed point                54.2 Q + 0.3 jQ
         Return Loss                                            —27.9 dB


   Antenna Parameters with Head TSL at 5750 MHz

         Impedance, transformed to feed point                51.7 Q — 0.8 jQ
         Return Loss                                            — 34.7 dB

   Antenna Parameters with Head TSL at 5800 MHz

         Impedance, transformed to feed point                52.1 Q — 24 jQ
         Return Loss                                            — 30.1 dB




   Certificate No: D5GHzV2—1060_Jul19




                                                             fon un n n n e n n n e n en y e >


                                                                     6 ww en n se cz n a se     k un   e q

                                                                              6oviys   ra v   on   yc




Antenna Parameters with Body TSL at 5200 MHz

      Impedance, transformed to feed point                      48.9 Q — 5.6 jQ
      Return Loss                                                 — 24.8 dB


Antenna Parameters with Body TSL at 5250 MHz

      Impedance, transformed to feed point                      48.0 Q — 2.2 jQ
      Return Loss                                                 — 30.4 dB

Antenna Parameters with Body TSL at 5300 MHz

      Impedance, transformed to feed point                      48.3 Q — 3.0 jQ
      Return Loss                                                 —29.1 dB


Antenna Parameters with Body TSL at 5500 MHz

      Impedance, transformed to feed point                      50.2 Q — 2.2 jQ
      Return Loss                                                  — 33.1 dB


Antenna Parameters with Body TSL at 5600 MHz

      Impedance, transformed to feed point                      55.5 Q + 1.0 jQ
      Return Loss                                                 —25.5 dB

Antenna Parameters with Body TSL at 5750 MHz

      Impedance, transformed to feed point                      52.3 Q + 0.8 jQ
      Return Loss                                                 — 32.3 dB

Antenna Parameters with Body TSL at 5800 MHz

      Impedance, transformed to feed point                      52.9 Q — 1.8 jQ
      Return Loss                                                 —29.5 dB




Certificate No: D5GHzV2—1060_Jul19           Page 12 of 23




                                                             @vv,yl..:,--.. «m engires ruour y ou wy U rd L.


©
General Antenna Parameters and Design

      Electrical Delay (one direction)                                                   1.201 ns

After long term use with 100W radiated power, only a slight warming of the dipole near the feedpoint can be measured.

The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the
second arm of the dipole. The antenna is therefore short—circuited for DC—signals. On some of the dipoles, small end caps
are added to the dipole arms in order to improve matching when loaded according to the position as explained in the
"Measurement Conditions" paragraph. The SAR data are not affected by this change. The overall dipole length is still
according to the Standard.
No excessive force must be applied to the dipole arms, because they might bend or the soldered connections near the
feedpoint may be damaged.

Additional EUT Data

      Manufactured by                                                                    SPEAG




Certificate No: D5GHzV2—1060_Jul19                      Page 13 of 23


3S
({I
      DASY5 Validation Report for Head TSL

                                                                                          Date: 22.07.2019

      Test Laboratory: SPEAG, Zurich, Switzerland

      DUT: Dipole DSGHzV2; Type: D5SGHzV2; Serial: D5SGHzV2 — SN:1060

      Communication System: UID 0 — CW; Frequency: 5200 MHz, Frequency: 5250 MHz, Frequency: 5300
      MHz, Frequency: 5500 MHz, Frequency: 5600 MHz, Frequency: 5750 MHz, Frequency: 5800 MHz
      Medium parameters used: f = 5200 MHz; 0 = 4.46 S/m:; &, = 35.5; p = 1000 kg/m* ,
      Medium parameters used: £ = 5250 MHz; 0 = 4.51 S/m:; & = 35.5; p = 1000 kg/m* ,
      Medium parameters used: f = 5300 MHz; 0 = 4.56 $/m:; &, = 35.4; p = 1000 kg/m* ,
      Medium parameters used: f = 5500 MHz; 0 = 4.76 $/m; & = 35.1; p = 1000 kg/m3 s
      Medium parameters used: £ = 5600 MHz; 0 = 4.86 S/m; &, = 35; p = 1000 kg/m3 s
      Medium parameters used: f = 5750 MHz; o = 5.02 $/m:; &, = 34.8; p = 1000 kg/m* ,
      Medium parameters used: £ = 5800 MHz; 0 = 5.07 S$/m; &, = 34.7; p = 1000 kg/m3
      Phantom section: Flat Section
      Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19—2011)

      DASY52 Configuration:

         e   Probe: EX3DV4 — SN3503; ConvF(5.64, 5.64, 5.64) @ 5200 MHz, ConvF(5.4, 5.4, 5.4) @ 5250
             MHz, ConvF(5.39, 5.39, 5.39) @ 5300 MHz, ConvF(5.1, 5.1, 5.1) @ 5500 MHz, ConvF(4.95, 4.95,
             4.95) @ 5600 MHz, ConvF(4.98, 4.98, 4.98) @ 5750 MHz, ConvF(4.96, 4.96, 4.96) @ 5800 MHz;
             Calibrated: 25.03.2019

         e    Sensor—Surface: 1.4mm (Mechanical Surface Detection)

         e   Electronics: DAE4 Sn601; Calibrated: 30.04.2019

         *    Phantom: Flat Phantom 5.0 (front); Type: QD 000 P50 AA; Serial: 1001

         e    DASY532 52.10.2(1504); SEMCAD X 14.6.12(7470)


      Dipole Calibration for Head Tissue/Pin=100mW, dist=10mm, £=5200 MHz/Zoom Scan,
      dist=1.4mm (8x8x7)/Cube 0: Measurementgrid: dx=4mm, dy=4mm, dz=1.4mm
      Reference Value = 74.16 V/m; Power Drift = 0.09 dB
      Peak SAR (extrapolated) = 28.1 W/kg
      SAR(1 g) = 8.06 W/kg; SAR(10 g) = 2.32 W/kg
      Maximum value of SAR (measured) = 17.8 W/kg

      Dipole Calibration for Head Tissue/Pin=100mW, dist=10mm, £=5250 MHz/Zoom Scan,
      dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
      Reference Value = 74.71 V/m; Power Drift = 0.07 dB
      Peak SAR (extrapolated) = 27.3 W/kg
      SAR(I g) = 8.07 W/kg; SAR(10 g) = 2.33 W/kg
      Maximum value of SAR (measured) = 17.8 W/kg




      Certificate No: D5GHzV2—1060_Jul19            Page 14 of 23


Dipole Calibration for Head Tissue/Pin=100mW, dist=10mm, £=5300 MHz/Zoom Scan,
dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 75.07 V/m; Power Drift = 0.08 dB
Peak SAR (extrapolated) = 28.8 W/kg
SAR(1 g) = 8.23 W/kg; SAR(10 g) = 2.37 W/kg
Maximum value of SAR (measured) = 18.5 W/kg

Dipole Calibration for Head Tissue/Pin=100mW, dist=10mm, £=5500 MHz/Zoom Scan,
dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 74.21 V/m; Power Drift = 0.7 dB
Peak SAR (extrapolated) = 32.1 W/kg
SAR(1 g) = 8.51 W/kg; SAR(10 g) = 2.43 W/kg
Maximum value of SAR (measured) = 19.6 W/kg

Dipole Calibration for Head Tissue/Pin=100mW, dist=10mm, £=5600 MHz/Zoom Scan,
dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 75.03 V/m; Power Drift = 0.06 dB
Peak SAR (extrapolated) = 31.0 W/kg
SAR(1 g) = 8.49 W/kg; SAR(10 g) = 2.43 W/kg
Maximum value of SAR (measured) = 19.4 W/kg

Dipole Calibration for Head Tissue/Pin=100mW, dist=10mm, £=5750 MHz/Zoom Scan,
dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 71.89 V/m; Power Drift = 0.09 dB
Peak SAR (extrapolated) =31.1 W/kg
SAR(I g) = 8.08 W/kg; SAR(10 g) = 2.31 W/kg
Maximum value of SAR (measured) = 18.8 W/kg

Dipole Calibration for Head Tissue/Pin=100mW, dist=10mm, £=5800 MHz/Zoom Scan,
dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 72.69 V/m; Power Drift = 0.09 dB
Peak SAR (extrapolated) = 31.8 W/kg
SAR(I g) = 8.14 W/kg; SAR(10 g) = 2.30 W/kg
Maximum value of SAR (measured) = 19.0 W/kg




Certificate No: D5GHzV2—1060_Jul19           Page 15 of 23


        —12.00


        —18.00


        —24.00


        —30.00
                   0 dB = 19.0 W/kg = 12.79 dBW/kg




Certificate No: D5GHzV2—1060_Jul19            Page 16 of 23


©
Impedance Measurement Plot for Head TSL (5200, 5250, 5300, 5500, 5600 MHz)



     File View     Channel   Sweep   Calibration   Trace Scale   Marker System Window   Help
                                                                                          »1
                                                                                                   uons
                                                                                               5.200000 GHz       48.730 0
                                                                                                   5.6041 pF     54615 2
                                                                                           2   5.250000 GHz       48.649 N
                                                                                                   7.6569 pF     —3.9595 n
                                                                                           3   5.300000 GHz       47.726 0
                                                                                                   9.0677 pF     33117 0
                                                                                           4   5.500000 GHz       50.970 n
                                                                                                   7.5146 pF     —3.8508 N
                                                                                           5   5.600000 GHz       54.204 N
                                                                                                  9.1876 pH     323.27 m0




                  Ch1Aug= 20
         Ch1: Start 5.00000 GHa   ——                                                                     Stop 6,00000 GHz




                                                                                                        GHz     —27.727 4B




         .00

         00
         00
         00
         .0 0      Ch 1
         C h1: Start 5.                                                                                        6.00000 GHz

                                                                        Avg=20 Delay




Certificate No: D5GHzV2—1060_Jul19                          Page 17 of 23


                                                                                                               ~o —




Impedance Measurement Plot for Head TSL (5750, 5800 MHz)



          File        View    Channel   Sweep   Calibration   Trace      Scale   Marker System Window   Help
                                                                                                           6    5.750000 GHz    §1.675 n
                                                                                                                    3S13pF     44352m0
                                                                                                          >7    5.200000 GHz    §2.138 0
                                                                                                                    11.515pF   23630 a




                             Ch1Aug= 20
                  Ch1: Start 5.00000 GHa   ——                                                                            Stop 600000 GHz

             0.00                                                                                                       GHe    34.681 dB
            5.00
            0.00
                 00




                 00

                 00
                 00
                 00
                 .00         1     =
                 Ch1: Start 5,00000 GHe    ——

            Status           CH 1:                            C*1—Port                  Avg=20 Delay                           tCE




Certificate No: D5GHzV2—1060_Jul19                                    Page 18 of 23


({Ifll
         &
        DASY5 Validation Report for Body TSL

                                                                                            Date: 22.07.2019

        Test Laboratory: SPEAG, Zurich, Switzerland

        DUT: Dipole DSGHzV2; Type: D5GHzV2; Serial: D5GHzV2 — SN:1060

        Communication System: UID 0 — CW; Frequency: 5200 MHz, Frequency: 5250 MHz, Frequency: 5300
        MHz, Frequency: 5500 MHz, Frequency: 5600 MHz, Frequency: 5750 MHz, Frequency: 5800 MHz
        Medium parameters used: f = 5200 MHz; 0 = 5.43 S/m; & = 47.3; p = 1000 kg/m3 ,
        Medium parameters used: £ = 5250 MHz; 0 = 5.49 $/m; & = 47.2; p = 1000 kg/m3 s
        Medium parameters used: £ = 5300 MHz; 0 = 5.56 $/m; & = 47.1; p = 1000 kg/m* ,
        Medium parameters used: £ = 5500 MHz; 0 = 5.83 S/m; & = 46.7; p = 1000 kg/m* ,
        Medium parameters used: £ = 5600 MHz; 0 = 5.97 S/m; &, = 46.6; p = 1000 kg/m3 s
        Medium parameters used: £ = 5750 MHz; 0 = 6.17 $/m; & = 46.3; p = 1000 kg/m* ,
        Medium parameters used: £ = 5800 MHz; 0 = 6.24 S/m; & = 46.2; p = 1000 kg/m3
        Phantom section: Flat Section
        Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19—2011)

        DASY52 Configuration:

            e   Probe: EX3DV4 — SN3503; ConvF(5.14, 5.14, 5.14) @ 5200 MHz, ConvF(5.26, 5.26, 5.26) @ 5250
                MHz, ConvF(5.25, 5.25, 5.25) @ 5300 MHz, ConvF(4.79, 4.79, 4.79) @ 5500 MHz, ConvF(4.74,
                4.74, 4.74) @ 5600 MHz, ConvF(4.62, 4.62, 4.62) @ 5750 MHz, ConvF(4.62, 4.62, 4.62) @ 5800
                MHz; Calibrated: 25.03.2019

            e   Sensor—Surface: 1.4mm (Mechanical Surface Detection)

            e   Electronics: DAE4 Sn601; Calibrated: 30.04.2019

            &   Phantom: Flat Phantom 5.0 (back); Type: QD 000 P50 AA; Serial: 1002

            e   DASY52 52.10.2(1504); SEMCAD X 14.6.12(7470)


        Dipole Calibration for Body Tissue/Pin=100mW, dist=10mm, £=5200 MHz/Zoom Scan,
        dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
        Reference Value = 68.89 V/m; Power Drift = —0.00 dB
        Peak SAR (extrapolated) = 27.5 W/kg
        SAR(I g) = 7.41 W/kg; SAR(10 g) = 2.08 W/kg
        Maximum value of SAR (measured) = 17.2 W/kg

        Dipole Calibration for Body Tissue/Pin=100mW, dist=10mm, £=5250 MHz/Zoom Scan,
        dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
        Reference Value = 69.26 V/m; Power Drift = 0.00 dB
        Peak SAR (extrapolated) = 29.2 W/kg
        SAR(I g) = 7.67 W/kg; SAR(10 g) = 2.15 W/kg
        Maximum value of SAR (measured) = 17.9 W/kg




        Certificate No: D5GHzV2—1060_Jul19            Page 19 of 23



Document Created: 2019-09-25 16:24:11
Document Modified: 2019-09-25 16:24:11

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC