Test Report

FCC ID: ZNFX440IM

Test Report

Download: PDF
FCCID_4420129

                                                                                                  REPORT No.:SZ19060060E01




                                          TEST REPORT

                                 APPLICANT                               : LG Electronics USA,Inc.

                                 PRODUCT NAME                            : Smartphone

                                 MODEL NAME                              : LM-X440IM

                                 BRAND NAME                              : LG

                                 FCC ID                                  : ZNFX440IM

                                 STANDARD(S)                             : 47 CFR Part 15 Subpart B

                                 RECEIPT DATE                            : 2019-06-05

                                 TEST DATE                               : 2019-06-22 to 2019-08-07

                                 ISSUE DATE                              : 2019-08-13




                                                                  Edited by:
                                                                                               Zeng Jianqing(Rapporteur)


                                                                  Approved by:
                                                                                               Andy Yeh(Technical Director)



NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the
company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for
validation and information confirmed at our website.


 MORLAB
                         SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                      Tel: 86-755-36698555   Fax: 86-755-36698525
                         FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China      Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                                 Page1of 20


                                                                                           REPORT No.:SZ19060060E01


                                                         DIRECTORY
1. Technical Information········································································································ 3
1.1. Applicant and Manufacturer Information····································································· 3
1.2. Equipment Under Test (EUT) Description ··································································· 3
2. Test Results ························································································································ 5
2.1. Applied Reference Documents ····················································································· 5
2.2. EUT Setup and Operating Conditions ·········································································· 6
3. 47 CFR Part 15B Requirements ······················································································· 7
3.1. Conducted Emission ······································································································ 7
3.2. Radiated Disturbance ··································································································· 11
Annex A Photographs of Test Setup ················································································· 16
Annex B Test Uncertainty ··································································································· 18
Annex C Testing Laboratory Information ········································································· 19




                                                               Change History
           Version                                  Date                                     Reason for change
              1.0                             2019-08-13                                             First edition




MORLAB
                     SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                     FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                     Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                          Page2of 20


                                                                                     REPORT No.:SZ19060060E01

1. Technical Information
Note: Provide by applicant

1.1. Applicant and Manufacturer Information

 Applicant:                             LG Electronics USA,Inc.
 ApplicantAddress:                      1000 Sylvan Ave.Englewood Cliffs,New Jersey,United States
                                        07632
 Manufacturer:                          OPTIEMUS ELECTRONICS LIMITED .
 ManufacturerAddress:                   D-348, Sector 63, Gautam Budh Nagar, Noida, Uttar Pradesh
                                        201307 India


1.2. Equipment Under Test (EUT) Description

 EUT Type:                     Smartphone
 Serial No:                    (N/A, marked #1 by test site)
 Hardware Version:             V0.10
 Software Version:             LG_IM-X440IM_Software
 Tx Frequency:                 GSM850: 824 MHz ~ 849 MHz
                               GSM1900: 1850 MHz ~ 1910 MHz
                               LTE Band 5: 824 MHz ~ 849 MHz
                               LTE Band 40: 2300 MHz ~2400 MHz
                               LTE Band 41: 2535 MHz ~2655MHz
                               802.11b/g/n-20: 2412 MHz ~ 2462 MHz
                               Bluetooth: 2402 MHz ~ 2480 MHz
 Rx Frequency:                 GSM850: 869 MHz ~ 894 MHz
                               GSM1900: 1930 MHz ~ 1990 MHz
                               LTE Band 5: 869 MHz ~ 894 MHz
                               LTE Band 40: 2300 MHz ~2400 MHz
                               LTE Band 41: 2535 MHz ~2655MHz
                               802.11b/g/n-20: 2412 MHz ~ 2462 MHz
                               Bluetooth: 2402 MHz ~ 2480 MHz
 Ancillary                     AC Adapter 1
 Equipment:                    Brand Name:                                N/A
                               Model No.:                                 TN-050200U4
                               Serial No.:                                (N/A, marked #1 by test site)
                               Rated Input:                               100-240V 50/60Hz, 0.35A
                               Rated Output:                              5V 2A



MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page3of 20


                                                                                     REPORT No.:SZ19060060E01

                               Manufacturer:                              Shenzhen BMT Electronics Co., Ltd.
                               AC Adapter 2
                               Brand Name:                                N/A
                               Model No.:                                 LG2AUKPA-1
                               Serial No.:                                (N/A, marked #1 by test site)
                               Rated Input:                               100-240V 50/60Hz, 0.35A
                               Rated Output:                              5V 2A
                               Manufacturer:                              UKB ELECTRONICS PVT LTD
                               Battery
                               Brand Name:                                LG
                               Model No.:                                 LG4000STCL02
                               Serial No.:                                (N/A, marked #1 by test site)
                               Capacity:                                  3900mAh
                               Rated Voltage:                             3.85V
                               Charge Limit:                              4.40V


Note:


1. The Smartphone supports GSM850MHz, 1900MHz, EDGE, WCDMA Band 5, Band 40, Band

   41. Bluetoothband, WIFI (802.11b/g/n-20) band.

2. There are two types of adapters, both adapters have been tested, only the worst case

   (TN-050200U4) is recorded in this report.

3. For a more detailed description, please refer to specification or user’s manual supplied by the

   applicant and/or manufacturer.




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page4of 20


                                                                                      REPORT No.:SZ19060060E01

2. Test Results
2.1. Applied Reference Documents
The objective of the report is to perform testing according to 47 CFR Part 15 Subpart B:

         No.   Identity                                                   Document Title
         1     47 CFR Part 15                                             Radio Frequency Devices

Test detailed items/section required by FCC rules andresults are as below:

     No.     Section         Description                             Test Date        Test Engineer              Result
     1       15.107          Conducted Emission                      2019.06.22       Peng Xuewei                PASS
     2       15.109          Radiated Emission                       2019.07.10       Peng Xuewei                PASS

NOTE: The tests were performed according to the method of measurements prescribed in ANSI
C63.4-2014.




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                     Page5of 20


                                                                                      REPORT No.:SZ19060060E01

2.2. EUT Setup and Operating Conditions

Test Item
Radiated Emission
Mode 1      : Adapter#1(TN-050200U4) +EUT + earphone + Camera recording + GSM idle
              +LTE idle + WIFI idle + Bluetooth idle
Mode 2  : Adapter#2(LG2AUKPA-1) +EUT + earphone + Camera recording + GSM idle + LTE
          idle +WIFI idle + Bluetooth idle
Mode 3 : NB Adapter + NB +EUT + data transmission + GSM idle + LTE idle +WIFI idle +
          Bluetooth idle
Conducted Emission
Mode 1      : Adapter#1(TN-050200U4) +EUT + earphone + Camera recording + GSM idle
              +LTE idle + WIFI idle + Bluetooth idle
Mode 2      : Adapter#2(LG2AUKPA-1) +EUT + earphone + Camera recording + GSM idle + LTE
              idle +WIFI idle + Bluetooth idle
Mode 3      : NB Adapter + NB +EUT + data transmission + GSM idle + LTE idle +WIFI idle +
              Bluetooth idle
Remark:
The above test modes (mode 1) in boldface were the worst case of conducted emission, Radiated
Emissiontests; only the result in the boldface mode (mode 1) is recorded in this report.

During the measurement, the environmental conditions were within the listed ranges:

 Temperature (°C):                                                        15 - 35
 Relative Humidity (%):                                                   30 - 60
 Atmospheric Pressure (kPa):                                              86 - 106




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                     Page6of 20


                                                                                          REPORT No.:SZ19060060E01


3.        47 CFR Part 15B Requirements
3.1. Conducted Emission
3.1.1.    Requirement
According to FCC section 15.107, the radio frequency voltage that is conducted back onto the
ACpower line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in
thefollowing table, as measured using a 50µH/50Ω line impedance stabilization network (LISN).

   Frequency range                                                          Conducted Limit (dBµV)
        (MHz)                                            Quasi-peak                                              Average
         0.15 - 0.50                                        66 to 56                                             56 to 46
          0.50 - 5                                               56                                                 46
           5 - 30                                                60                                                 50
     NOTE:
     a) The limit subjects to the Class B digital device.
     b) The lower limit shall apply at the band edges.
     c) The limit decreases linearly with the logarithm of the frequency in the range 0.15 -
     0.50MHz.


3.1.2.    Test Setup

Please refer to Annex A for the photographs of the Test Configuration.




MORLAB
                    SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555    Fax: 86-755-36698525
                    FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                    Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn    E-mail: service@morlab.cn

                                                                                                                                          Page7of 20


                                                                                     REPORT No.:SZ19060060E01

The EUT is placed on a 0.8m high insulating table, which stands on the grounded conducting floor,
and keeps 0.4m away from the grounded conducting wall. The EUT is connected to the power
mains through a LISN which provides 50Ω/50µH of coupling impedance for the measuring
instrument. A Pulse Limiter is used to protect the measuring instrument. The factors of the whole
test system are calibrated to correct the reading.

The power strip or extension cord has been investigated to make sure that the LISN integrity inma
intained with respect to the impedance characteristics as prescribed in ANSI C63.4-2014 at
Clause 4.3.


3.1.3.   Test Result

The maximum conducted interference is searched using Peak (PK), Quasi-peak (QP) and Average
(AV) detectors; the emission levels more than the AV and QP limits, and that have narrow margins
from the AV and QP limits will be re-measured with AV and QP detectors.Tests for both L phase
and N phase lines of the power mains connected to the EUT are performed. All test modes are
considered, refer to recorded points and plots below.




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page8of 20


                                                                                      REPORT No.:SZ19060060E01

A. Test Plot and Suspicious Points:




                                                           (Plot A:L Phase)




        Fre.         Emission Level (dBµV)                                    Limit (dBµV)
 NO.                                                                                                         Power-line            Verdict
       (MHz)         Quai-peak                Average                Quai-peak        Average
  1    0.4197            35.60                   28.83                    57.45          47.45                                        PASS
  2    0.5015            44.63                   37.29                    56.00          46.00                                        PASS
  3    0.9379            35.43                   26.92                    56.00          46.00                                        PASS
                                                                                                                Line
  4    1.2074            34.46                   25.49                    56.00          46.00                                        PASS
  5    4.8292            37.96                   29.37                    56.00          46.00                                        PASS
  6    13.1161           43.65                   35.14                    60.00          50.00                                        PASS




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555     Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                       Page9of 20


                                                                                      REPORT No.:SZ19060060E01




                                                         (Plot B: N Phase)




        Fre.        Emission Level (dBµV)                                     Limit (dBµV)
 NO.                                                                                                         Power-line            Verdict
       (MHz)        Quai-peak                 Average                Quai-peak        Average
  1    0.2489           38.95                    29.82                    61.79          51.79                                        PASS
  2    0.3567           35.08                    25.68                    58.81          48.81                                        PASS
  3    0.5007           43.41                    39.07                    56.00          46.00                                        PASS
                                                                                                              Neutral
  4    0.7894           34.86                    27.10                    56.00          46.00                                        PASS
  5    0.9966           35.84                    29.20                    56.00          46.00                                        PASS
  6    1.2528           33.80                    25.23                    56.00          46.00                                        PASS




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555     Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                      Page10of 20


                                                                                      REPORT No.:SZ19060060E01

3.2. Radiated Disturbance

3.2.1. Requirement

According to FCC section 15.109 (a), the field strength of radiated emissions from
unintentionalradiators at a distance of 3 meters shall not exceed the following values:

              Frequency                 Field Strength Limitation at 3m Measurement Dist
             range (MHz)                              (µV/m)                                  (dBµV/m)
              30.0 - 88.0                                100                                  20log 100
             88.0 - 216.0                                150                                  20log 150
            216.0 - 960.0                                200                                  20log 200
             Above 960.0                                 500                                  20log 500

As shown in FCC section 15.35(b), for frequencies above 1000MHz, the field strength limits are
based on average detector. When average radiated emission measurements are specified in this
part, including emission measurements below 1000MHz, there also is a limit on the radio
frequency emissions, as measured using instrumentation with a peak detector function,
corresponding to 20dB above the maximum permitted average limit for the frequency being
investigated unless a different peak emission limit is otherwise specified in the rules.

Note:

1)   The tighter limit shall apply at the boundary between two frequency range.
2)   Limitation expressed in dBµV/m is calculated by 20log Emission Level(µV/m).


3.2.2. Frequency range of measurement

According to 15.33(b)(1), the frequency range of radiated measurement for the EUT is listed in the
following table:




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page11of 20


                                                                                     REPORT No.:SZ19060060E01

3.2.3. Test Setup

1)   For radiated emissions from 30MHz to1GHz




2)   For radiated emissions above 1GHz




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page12of 20


                                                                                      REPORT No.:SZ19060060E01

The test is performed in a 3m Semi-Anechoic Chamber; the antenna factor, cable loss and so on of
the site (factors) is calculated to correct the reading.The EUT is placed on a 0.8m high insulating
Turn Table, and keeps 3m away from theTest Antenna, which is mounted onavariable-height
antenna master tower.

For the test Antenna:

In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) and Horn
TestAntenna (above 1GHz)are used. Test Antenna is 3m away from the EUT. Test Antenna height
is varied from 1m to 4m above the ground to determine the maximum value of the field strength.
The emission levels at both horizontal and vertical polarizations should be tested.


3.2.4.   Test Result

The maximum radiated emission is searched using PK, QP and AV detectors; the emission levels
more than the limits, and that have narrow margins from the limits will be re-measured with AV and
QP detectors. Both the vertical and the horizontal polarizations of the Test Antenna are considered
to perform the tests. All test modes are considered, refer to recorded points and plots below.

The amplitude of emissions which (6GHz-13GHz) are attenuated more than 20 dB below the
permissible value need not be reported.

Note: All radiated emission tests were performed in X, Y, Z axis direction, and only the worst axis
test condition was recorded in this test report.




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page13of 20


                                                                                       REPORT No.:SZ19060060E01




                                          (Plot A: ANT-Vertical,30MHz - 6GHz)




         Fre.               Pk               QP                AV           Limit-PK   Limit-QP           Limit-AV
 No.                                                                                                                      ANT          Verdict
         MHz            dBµV/m           dBµV/m            dBµV/m            dBµV/m    dBµV/m             dBµV/m
 1      30.003            37.31             32.27             N.A               N.A      40.00                N.A            V         PASS
 2     105.660            27.14              N.A              N.A               N.A      40.00                N.A            V         PASS
 3     1768.000           44.51              N.A              N.A              70.00       N.A                50.00          V         PASS
 4     2450.667           46.20              N.A              N.A              70.00       N.A                50.00          V         PASS
 5     3900.480           43.74              N.A              N.A              74.00       N.A                54.00          V         PASS
 6     5404.480           45.32              N.A              N.A              74.00       N.A                54.00          V         PASS




MORLAB
                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555     Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                        Page14of 20


                                                                                       REPORT No.:SZ19060060E01




                                       (Plot B:ANT- Horizontal, 30MHz - 6GHz)




         Fre.               Pk               QP                AV           Limit-PK   Limit-QP          Limit-AV
 No.                                                                                                                      ANT          Verdict
         MHz           dBµV/m            dBµV/m           dBµV/m            dBµV/m     dBµV/m             dBµV/m
 1      37.760            29.78              N.A              N.A               N.A      40.00                N.A           H          PASS
 2     100.810            26.55              N.A              N.A               N.A      40.00                N.A           H          PASS
 3     334.580            27.45              N.A              N.A               N.A      47.00                N.A           H          PASS
 4     2405.867           47.23              N.A              N.A             70.00       N.A                 50.00         H          PASS
 5     3694.400           44.14              N.A              N.A             74.00       N.A                 54.00         H          PASS
 6     5702.720           46.44              N.A              N.A             74.00       N.A                 54.00         H          PASS




MORLAB
                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555     Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                        Page15of 20


                                                                                      REPORT No.:SZ19060060E01



Annex A Photographs of Test Setup
1.   Mains Terminal Disturbance Voltage Measurement




2.   Conducted emission main’s port side view




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page16of 20


                                                                                     REPORT No.:SZ19060060E01

3.   Radiated Field Strength Measurement(30MHz-1GHz)




4.   Radiated Field Strength Measurement(above 1GHz)




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page17of 20


                                                                                    REPORT No.:SZ19060060E01

Annex B Test Uncertainty
The uncertainty is calculated using the methods suggested in the "Guide to the Expression of
Uncertainty in Measurement" (GUM) published by ISO.

Uncertainty of Conducted Emission Measurement

 Measuring Uncertainty for 9kHz-150kHz                                                   ±4.1 dB
 a Level of Confidence of 150kHz-30MHz                                                   ±3.7dB
 95%(U=2Uc(y))

Uncertainty of Radiated Emission Measurement

 Measuring Uncertainty for 30MHz-200MHz                                                  ±5.06dB
 a Level of Confidence of 200MHz-1000MHz                                                 ±5.24dB
 95%(U=2Uc(y))             1GHz-6GHz                                                     ±5.18dB
                                      6GHz-18GHz                                         ±5.48dB




MORLAB
              SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                  Page18of 20


                                                                                     REPORT No.:SZ19060060E01

Annex C Testing Laboratory Information
1. Identification of the Responsible Testing Laboratory

 Laboratory Name:                             Shenzhen Morlab Communications Technology Co., Ltd.
                                              Morlab Laboratory
 Laboratory Address:                          FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                              Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                              Province, P. R. China
 Telephone:                                   +86 755 36698555
 Facsimile:                                   +86 755 36698525

2. Identification of the Responsible Testing Location

                                               Shenzhen Morlab Communications Technology Co., Ltd.
 Name:
                                               Morlab Laboratory
                                               FL.3, Building A, FeiYang Science Park, No.8 LongChang
 Address:                                      Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                               Province, P. R. China

3. Accreditation Certificate

 AccreditedTesting                             The FCC designation number is CN1192.
 Laboratory:                                   Test firm registration number is 226174.
                                               (Shenzhen Morlab Communications Technology Co., Ltd.)

4. Test Software Utilized

              Model                                      Version Number                                     Producer
     MORLAB EMCR V1.2                                          Version 1.0                                  MORLAB
        TS+ -[ JS32-CE]                                     Version2.5.0.0                                  Tonscend




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page19of 20


                                                                                             REPORT No.:SZ19060060E01

5. Test Equipments Utilized

  Description           Manufacturer                        Model                       Serial No.           Cal. Date            Due. Date
   MXE EMI
                              Agilent                      N9038A                  MY54130016               2019.04.09           2020.04.08
   Receiver
  Test Receiver                 R&S                          ESPI                        101052             2018.08.04           2019.08.03
      LISN               Schwarzbeck                    NSLK 8127                        812744             2019.05.08           2020.05.07
  Pulse Limiter
                               VTSD                         9561D                         9537              2019.05.08           2020.05.07
     (20dB)
 Test Antenna -
                         Schwarzbeck                    VULB 9163                       9163-519            2019.05.08           2020.05.07
     Bi-Log
 Test Antenna -
                         Schwarzbeck                  BBHA 9120D                          1774              2019.05.08           2020.05.07
      Horn
   Radiated
                                                      S020180L320
  Disturbance                  rflight                                              61171/61172             2019.07.12           2020.07.11
                                                           3
  Preamplifier
   Radiated
                                                      S10M100L38
  Disturbance                  rflight                                                   46732              2019.07.12           2020.07.11
                                                          02
  Preamplifier
 Semi-Anechoic
                                CRT                     9m*6m*6m                           N/A              2017.01.12           2020.01.11
   Chamber

                                                           END OF REPORT




MORLAB
                  SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                        Tel: 86-755-36698555   Fax: 86-755-36698525
                  FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                  Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China        Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                           Page20of 20



Document Created: 2019-08-22 13:19:35
Document Modified: 2019-08-22 13:19:35

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC