detailed test result SAR

FCC ID: ZNFX430EMW

Test Report

Download: PDF
FCCID_4435311

              SGS-CSTC Standards Technical Services Co., Ltd.
              Shenzhen Branch
                                      Report No.: ZR/2019/7002105




               Appendix B
             Detailed Test Results
1. GSM
GSM850 for Head & Body
GSM1900 for Head & Body
2. WCDMA
WCDMA Band II for Head & Body
WCDMA Band V for Head & Body
3.WIFI
WIFI 2.4G for Head & Body
4.BT
BT for Head


                                                                           Date: 2019—08—16

Test Laboratory: SGS—SAR Lab

LM—X430EMW GSM850 GSM 190CH Right cheek

DUT: LM—X430EMW; Type: Mobile Handset; Serial: 907HUPZ0001560

Communication System: UID 0, GSM Only Communication System (0); Frequency: 836.6
MHz;Duty Cycle: 1:8.3

Medium: HSL835;Medium parameters used: {= 837 MHz; a = 0.893 S/m; & = 43.207; p= 1000
kg/m>
Phantom section: Right Section

DASY 5 Configuration:

   * Probe: EX3DV4 — SN3793; ConvF(.04, 9.04, 9.04), Calibrated: 2019—03—25;
   * Sensor—Surface: 1.4mm (Mechanical Surface Detection)
   * Electronics: DAE3 Sn414; Calibrated: 2018—12—03
   * Phantom: SAM 2; Type: SAM; Serial: 1913
   * DASY52 52.8.8(1222), SEMCAD X 14.6.10(7331)


Configuration/Head/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=1 5mm
Maximum value of SAR (measured) =0.263 W/kg

Configuration/Head/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 6.841 V/m; Power Drift=—0.14 dB
Peak SAR (extrapolated) = 0.284 W/kg
SAR( g) = 0.211 W/kg; SAR(10 g) = 0.162 W/g
Maximum value of SAR (measured) =0.251 W/kg




   41.92

   —3.04

   5.77

   —7.569

   —9.61
            0 dB =0.251 W/kg =—6.00 dBW/kg


                                                                            Date: 2019—08—16

Test Laboratory: SGS—SAR Lab

LM—X430EMW GSM850 GPRS 4TS 190CH Right side 10mm

DUT: LM—X430EMW; Type: Mobile Handset; Serial: 907HUPZ0001560

Communication System: UID 0, GPRS/EGPRS Mode(4up) Communication System (0); Frequency:
836.6 MHz,Duty Cycle: 1:2.075

Medium: HSL835;Medium parameters used: {= 837 MHz; a = 0.893 S/m; & = 43.207; p= 1000
kg/m>
Phantom section: Flat Section

DASY 5 Configuration:

    * Probe: EX3DV4 — SN3793; ConvF(.04, 9.04, 9.04), Calibrated: 2019—03—25;
    * Sensor—Surface: 1.4mm (Mechanical Surface Detection)
    * Electronics: DAE3 Sn414; Calibrated: 2018—12—03
    * Phantom: SAM 2; Type: SAM; Serial: 1913
    * DASY52 52.8.8(1222), SEMCAD X 14.6.10(7331)


Configuration/Body/Area Scan (5x13x1): Measurement grid: dx=15mm, dy=1 5mm
Maximum value of SAR (measured) =0.616 W/kg

Configuration/Body/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value= 22.75 V/m; Power Drift=0.05 dB
Peak SAR (extrapolated) = 0.732 W/kg
SAR( g) = 0.454 W/kg; SAR(10 g) = 0.313 W/g
Maximum value of SAR (measured) =0.621 W/kg




   —1.94

   —3.08

   —5.81

   —1.T5

   —9.69
             0 dB =0.621 W/ke =—2.07 dBW/kg


                                                                             Date: 2019—08—15

Test Laboratory: SGS—SAR Lab

LM—X430EMW GSM1900 GSM 661CH Left cheek

DUT: LM—X430EMW; Type: Mobile Handset; Serial: 907HUPZ0001560

Communication System: UID 0, GSM Only Communication System (0); Frequency: 1880
MHz;Duty Cycle: 1:8.3

Medium: H$L1900;Medium parameters used: f= 1880 MHz; a= 1.36 S/m; e =40.732; p= 1000
kg/m>
Phantom section: Left Section

DASY 5 Configuration:

    * Probe: EX3DV4 — SN3923; ConvF(®.51, 8.51, 8.51); Calibrated: 2018—09—30;
    * Sensor—Surface: 1.4mm (Mechanical Surface Detection)
    * Electronics: DAE4 Sn1428; Calibrated: 2019—01—11
    * Phantom: SAM 3; Type: SAM; Serial: 1912
    * DASY52 52.8.8(1222), SEMCAD X 14.6.10(7331)


Configuration/Head/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=1 5mm
Maximum value of SAR (measured) = 0.0924 W/kg

Configuration/Head/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value= 2.559 V/m; Power Drift=0.04 dB
Peak SAR (extrapolated) = 0.130 W/kg
SAR( g) = 0.078 W/kg; SAR(10 g) = 0.048 W/g
Maximum value of SAR (measured) =0.110 W/kg




   —4.09

   —8.19

   12.28

   16.38

   —20.47
             0 dB =0.110 W/ke =—9.59 dBW/kg


                                                                             Date: 2019—08—15

Test Laboratory: SGS—SAR Lab

LM—X430EMW GSM1900 GPRS 4TS 661CH Back side 10mm

DUT: LM—X430EMW; Type: Mobile Handset; Serial: 907HUPZ0001560

Communication System: UID 0, GPRS/EGPRS Mode(4up) Communication System (0);
Frequency: 1880 MHz;Duty Cycle: 1:2.075

Medium: H$L1900;Medium parameters used: f= 1880 MHz; a= 1.36 S/m; e =40.732; p= 1000
kg/m>
Phantom section: Flat Section

DASY 5 Configuration:

    * Probe: EX3DV4 — SN3923; ConvF(®.51, 8.51, 8.51); Calibrated: 2018—09—30;
    * Sensor—Surface: 1.4mm (Mechanical Surface Detection)
    * Electronics: DAE4 Sn1428; Calibrated: 2019—01—11
    * Phantom: SAM 3; Type: SAM; Serial: 1912
    * DASY52 52.8.8(1222), SEMCAD X 14.6.10(7331)


Configuration/Body/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=1 5mm
Maximum value of SAR (measured) =0.671 W/kg

Configuration/Body/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value= 12.10 V/m; Power Drift=0.03 dB
Peak SAR (extrapolated) = 0.882 W/kg
SAR( g) = 0.466 W/kg; SAR(10 g) = 0.249 W/g
Maximum value of SAR (measured) = 0.669 W/kg




   ~4.26

   —8.53

   12.79

   —17.06

   —21.32
             0 dB =0.669 W/kg =—1.75 dBW/kg


                                                                             Date: 2019—08—15

Test Laboratory: SGS—SAR Lab

LM—X430EMW WCDMA Band II 9400CH Left cheek

DUT: LM—X430EMW; Type: Mobile Handset; Serial: 907HUPZ0001560

Communication System: UID 0, WCDMA (0); Frequency: 1880 MHz;Duty Cycle: 1:1

Medium: H$L1900;Medium parameters used: f= 1880 MHz; a= 1.36 S/m; e =40.732; p= 1000
kg/m>
Phantom section: Left Section

DASY 5 Configuration:

    * Probe: EX3DV4 — SN3923; ConvF(®.51, 8.51, 8.51); Calibrated: 2018—09—30;
    * Sensor—Surface: 1.4mm (Mechanical Surface Detection)
    * Electronics: DAE4 Sn1428; Calibrated: 2019—01—11
    * Phantom: SAM 3; Type: SAM; Serial: 1912
    * DASY52 52.8.8(1222), SEMCAD X 14.6.10(7331)


Configuration/Head/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=1 5mm
Maximum value of SAR (measured) = 0.250 W/kg

Configuration/Head/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 3.990 V/m; Power Drift=0.06 dB
Peak SAR (extrapolated) = 0.357 W/kg
SAR( g) = 0.220 W/kg; SAR(10 g) = 0.138 W/g
Maximum value of SAR (measured) =0.307 W/kg




   ~4.01

   —8.02

   12.02

   16.03

   —20.04
             0 dB =0.307 We =—5.13 dBW/kg


                                                                             Date: 2019—08—15

Test Laboratory: SGS—SAR Lab

LM—X430EMW WCDMA Band II 9538CH Back side 10mm

DUT: LM—X430EMW; Type: Mobile Handset; Serial: 907HUPZ0001560

Communication System: UID 0, WCDMA (0); Frequency: 1907.6 MHz;Duty Cycle: 1:1

Medium: H$L1900;Medium parameters used: £= 1908 MHz; a= 1.381 S/m; & = 40.629; p= 1000
kg/m>
Phantom section: Flat Section

DASY 5 Configuration:

    * Probe: EX3DV4 — SN3923; ConvF(®.51, 8.51, 8.51); Calibrated: 2018—09—30;
    * Sensor—Surface: 1.4mm (Mechanical Surface Detection)
    * Electronics: DAE4 Sn1428; Calibrated: 2019—01—11
    * Phantom: SAM 3; Type: SAM; Serial: 1912
    * DASY52 52.8.8(1222), SEMCAD X 14.6.10(7331)


Configuration/Body/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=1 5mm
Maximum value of SAR (measured) =1.11 W/kg

Configuration/Body/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value= 11.35 V/m; Power Drift=—0.08 dB
Peak SAR (extrapolated) = 1.56 W/kg
SAR( g) = 0.815 W/kg; SAR(10 g) = 0.437 W/g
Maximum value of SAR (measured) =1.15 W/kg




   —4.42

   —8.84

   13.26

   —17.68

   —22.10
             0 dB =1.15 We =0.61 dBW/kg


                                                                           Date: 2019—08—16

Test Laboratory: SGS—SAR Lab

LM—X430EMW WCDMA Band V 4182CH Right cheek

DUT: LM—X430EMW; Type: Mobile Handset; Serial: 907HUPZ0001560

Communication System: UID 0, WCDMA (0); Frequency: 836.4 MHz;Duty Cycle: 1:1

Medium: HSL835;Medium parameters used (interpolated): £= 836.4 MHz; a = 0.892 S/m; s;=
43.21; p= 1000 kg/m?
Phantom section: Right Section

DASY 5 Configuration:

   * Probe: EX3DV4 — SN3793; ConvF(.04, 9.04, 9.04), Calibrated: 2019—03—25;
   * Sensor—Surface: 1.4mm (Mechanical Surface Detection)
   * Electronics: DAE3 Sn414; Calibrated: 2018—12—03
   * Phantom: SAM 2; Type: SAM; Serial: 1913
   * DASY52 52.8.8(1222), SEMCAD X 14.6.10(7331)


Configuration/Head/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=1 5mm
Maximum value of SAR (measured) =0.315 W/kg

Configuration/Head/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value= 5.867 V/m; Power Drift=0.18 dB
Peak SAR (extrapolated) = 0.360 W/kg
SAR( g) = 0.258 W/kg; SAR(10 g) = 0.199 W/g
Maximum value of SAR (measured) =0.318 W/kg




   41.91

   —3.81

   5.72

   ~1.62

   —1.53
            0 dB =0.318 W/ke =—4.98 dBW/kg


                                                                           Date: 2019—08—16

Test Laboratory: SGS—SAR Lab

LM—X430EMW WCDMA Band V 4182CH Right side 10mm

DUT: LM—X430EMW; Type: Mobile Handset; Serial: 907HUPZ0001560

Communication System: UID 0, WCDMA (0); Frequency: 836.4 MHz;Duty Cycle: 1:1

Medium: HSL835;Medium parameters used (interpolated): £= 836.4 MHz; a = 0.892 S/m; s;=
43.21; p= 1000 kg/m?
Phantom section: Flat Section

DASY 5 Configuration:

   * Probe: EX3DV4 — SN3793; ConvF(.04, 9.04, 9.04), Calibrated: 2019—03—25;
   * Sensor—Surface: 1.4mm (Mechanical Surface Detection)
   * Electronics: DAE3 Sn414; Calibrated: 2018—12—03
   * Phantom: SAM 2; Type: SAM; Serial: 1913
   * DASY52 52.8.8(1222), SEMCAD X 14.6.10(7331)


Configuration/Body/Area Scan (5x13x1): Measurement grid: dx=15mm, dy=1 5mm
Maximum value of SAR (measured) =0.470 W/kg

Configuration/Body/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 17.70 V/m; Power Drift=0.03 dB
Peak SAR (extrapolated) = 0.561 W/kg
SAR( g) = 0.356 W/kg; SAR(10 g) = 0.244 W/g
Maximum value of SAR (measured) =0.481 W/kg




   —1.94

   —3.89

   5.03

   —7.178

   —0.72
             0 dB =0.481 We =—3.18 dBW/kg


                                                                             Date: 2019—08—26

Test Laboratory: SGS—SAR Lab

LM—X430EMW WIFI 2.4G 802.11b 1CH Left cheek

DUT: LM—X430EMW; Type: Mobile Handset; Serial: 358854100123551

Communication System: UID 0, WI—FI(2.4GHz) (0), Frequency: 2412 MHz;Duty Cycle: 1:1.012

Medium: H$L2450;Medium parameters used: {= 2412 MHz; 0 = 1.747 S/m; & = 40.85; p= 1000
kg/m>
Phantom section: Left Section

DASY 5 Configuration:

    * Probe: EX3DV4 — SN3793; ConvF(6.93, 6.93, 6.93), Calibrated: 2019—03—25;
    * Sensor—Surface: 1.4mm (Mechanical Surface Detection)
    * Electronics: DAE3 Sn414; Calibrated: 2018—12—03
    * Phantom: SAM 1; Type: SAM; Serial: 1283
    * DASY52 52.8.8(1222), SEMCAD X 14.6.10(7331)


Configuration/Head/Area Scan (Ox16x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) =0.981 W/kg

Configuration/Head/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=Smm,
dz=5mm
Reference Value = 9.994 V/m; Power Drift=0.17 dB
Peak SAR (extrapolated) = 1.46 W/kg
SAR( g) = 0.584 W/kg; SAR(10 g) = 0.242 W/g
Maximum value of SAR (measured) = 1.06 W/hkg




   ~4.07

   8.13

   12.20

   16.26

   —20.33
             0 dB =1.06 Whkg=0.25 dBW/kg


                                                                             Date: 2019—08—26

Test Laboratory: SGS—SAR Lab

LM—X430EMW WIFI 2.4G 802.11b 6CH Back side 10mm

DUT: LM—X430EMW; Type: Mobile Handset; Serial: 358854100121852

Communication System: UID 0, WI—FI(2.4GHz) (0), Frequency: 2437 MHz;Duty Cycle: 1:1.012

Medium: H$L2450;Medium parameters used: £= 2437 MHz; a= 1.775 S/m; & = 40.762; p= 1000
kg/m>
Phantom section: Flat Section

DASY 5 Configuration:

    * Probe: EX3DV4 — SN3793; ConvF(6.93, 6.93, 6.93), Calibrated: 2019—03—25;
    * Sensor—Surface: 1.4mm (Mechanical Surface Detection)
    * Electronics: DAE3 Sn414; Calibrated: 2018—12—03
    * Phantom: SAM 1; Type: SAM; Serial: 1283
    * DASY52 52.8.8(1222), SEMCAD X 14.6.10(7331)


Configuration/Body/Area Scan (9x16x1): Measurement grid: dx=12mm, dy=1 2mm
Maximum value of SAR (measured) =0.346 W/kg

Configuration/Body/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=Smm, dy=5mm,
dz=5mm
Reference Value= 4.112 V/m; Power Drift=—0.06 dB
Peak SAR (extrapolated) = 0.606 W/kg
SAR(L g) = 0.270 W/kg; SAR(10 g) = 0.124 W/zg
Maximum value of SAR (measured) =0.471 W/kg

  dB
  0

   —3.00

   —7.59

   11.39

   —15.18

   —18.98
             0 dB =0.471 We =—3.27 dBW/kg


                                                                             Date: 2019—08—26

Test Laboratory: SGS—SAR Lab

LM—X430EMW Bluetooth DHS 0CH Left cheek

DUT: LM—X430EMW; Type: Mobile Handset; Serial: 907HUYNO001538

Communication System: UID 0, Bluetooth (0); Frequency: 2402 MHz;Duty Cycle: 1:1.306

Medium: H$L2450;Medium parameters used: £= 2402 MHz; a = 1.736 S/m; & = 40.885; p= 1000
kg/m>
Phantom section: Left Section

DASY 5 Configuration:

    * Probe: EX3DV4 — SN3793; ConvF(6.93, 6.93, 6.93), Calibrated: 2019—03—25;
    * Sensor—Surface: 1.4mm (Mechanical Surface Detection)
    * Electronics: DAE3 Sn414; Calibrated: 2018—12—03
    * Phantom: SAM 1; Type: SAM; Serial: 1283
    * DASY52 52.8.8(1222), SEMCAD X 14.6.10(7331)


Configuration/Head/Area Scan (Ox16x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) =0.111 W/kg

Configuration/Head/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=Smm,
dz=5mm
Reference Value=3.127 V/m; Power Drift=0.05 dB
Peak SAR (extrapolated) = 0.145 W/kg
SAR( g) = 0.068 W/kg; SAR(10 g) = 0.034 W/g
Maximum value of SAR (measured) =0.113 W/kg




   —3.04

   —6.07

   9.11

   1214

   —15.18
             0 dB =0.113 We =—9.47 dBW/kg