I18Z60493-SEM01_SAR_Rev0_part6

FCC ID: ZNFX410FTW

RF Exposure Info

Download: PDF
FCCID_3846641

im©
777                                                                                             ty s      n        c        n > ~
=‘-/




     &       &                                                  w‘ ty
 Callbl.'atlon Laboratory of                                  i\‘\\\\ij///'/';         S    Schweizerischer Kalibrierdienst
 Schmid & Partner                                            M                         c    Service suisse d‘étalonnage
    Engineering AG                                           o o mf                         Servizio svizzero di taratura
 Zeughausstrasse 43, 8004 Zurich, Switzerland                 * ///'\\\ y              S    Swiss Calibration Service
                                                                Carhitabe®®

 Accredited by the Swiss Accreditation Service (SAS)                                    Accreditation No.: SCS 0108
 The Swiss Accreditation Service is one of the signatories to the EA
 Multilateral Agreement for the recognition of calibration certificates



 Glossary
 DAE                          data acquisition electronics
 Connector angle              information used in DASY system to align probe sensor X to the robot
                              coordinate system.

 Methods Applied and Interpretation of Parameters
    e  DC Voltage Measurement: Calibration Factor assessed for use in DASY system by
      comparison with a calibrated instrument traceable to national standards. The figure given
      corresponds to the full scale range of the voltmeter in the respective range.
     e    Connector angle: The angle of the connector is assessed measuring the angle
          mechanically by a tool inserted. Uncertainty is not required.
     e    The following parameters as documented in the Appendix contain technical information as a
          result from the performance test and require no uncertainty.
                 DC Voltage Measurement Linearity: Verification of the Linearity at +10%and —10% of
                 the nominal calibration voltage. Influence of offset voltage is included in this
                 measurement.
                 Common mode sensitivity: Influence of a positive or negative common mode voltage on
                 the differential measurement.
                 Channel separation: Influence of a voltage on the neighbor channels not subject to an
                 input voltage.
                 AD Converter Values with inputs shorted: Values on the internal AD converter
                 corresponding to zero input voltage
                 Input Offset Measurement. Output voltage and statistical results over a large number of
                 zero voltage measurements.
                 Input Offset Current: Typical value for information; Maximum channel input offset
                 current, not considering the input resistance.
                 Input resistance: Typical value for information: DAE input resistance at the connector,
                 during internal auto—zeroing and during measurement.
                 Low Battery Alarm Voltage: Typical value for information. Below this voltage, a battery
                 alarm signal is generated.
                 Power consumption: Typical value for information. Supply currents in various operating
                 modes.




 Certificate No : DAE4—1525_Oct17                                 Page 2 of 5




                                                                                 wervopg n ne a io rgn rewr a vewruer e cona wmz


DC Voltage Measurement
   A/D — Converter Resolution nominal
       High Range:          1LSB =          6.1uV ,     full range =    —100...+300 mV
       Low Range:           1LSB =           61nV ,     full range =     —~1....... +3mV
   DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec

     Calibration Factors                X                           ¥                           Z
     High Range             405.912 + 0.02% (k=2)     405.954 £0.02% (k=2)        405.400 £ 0.02% (k=2)
     Low Range              8.99166 £ 1.50% (k=2)     4.00980 + 1.50% (k=2)       3.99550 £1.50% (k=2)


Connector Angle

     Connector Angle to be used in DASY system                                             sG56°%1°          J




Certificate No: DAE4—1525_Oct17                       Page 3 of 5




                                                                                Ne n veperg n rag en e mb n ng eene n nene se n en meg n nc


()
 S
 Appendix (Additional assessments outside the scope of SCS0O108)

 1. DC Voltage Linearity
      High Range
      Channel X
      Channel X
                      + Input
                      + Input
                                                 Reading (uV)
                                                  200030.95
                                                   20004.11
                                                                      Difference (1V)
                                                                             242
                                                                              —0.05
                                                                                                  Error (%)
                                                                                                  —0.00
                                                                                                  —0.00
      Channel X       — Input                     —20003.75                   2.02                0.01
      Channel Y       + Input                     200031.20                  —2.23                 0.00
      Channel Y       + Input                      20001.46                   ~2.74               —0.01
      Channel Y       — Input                     ~20005.92                   —0.05                0.00
      Channel Z       + Input                     200032.03                   ~1.05                0.00
      Channel Z       + Input                      20001.94                   «2241                —0.01
      Channel Z       = Input                     —20006.15                   —0.20                0.00


      Low Range                                  Reading (V)          Difference (LV)             Error (%)
      Channel X       + Input                      2000.66                    0.19                 0.01
      Channel X       + Input                       200.40                    —0.18                —0.09
      Channel X       = Input                      ~198.67                    0.81                 —0.40
      Channel Y       + Input                      2000.90                    0.48                 0.02
      Channel Y       + Input                       199.98                    —0.58                —0.29
      Channel Y       — Input                       —200.18                   —0.62                0.31
      Channel Z       + Input                      2000.68                    0.32                 0.02
      Channel Z       + Input                       199.07                    ~1.45                —0.72

      Channel Z       — Input                       +201.14                   ~1.52                0.76



 2. Common mode sensitivity
    DASY measurement parameters: Auto Zero Time: 3 sec; Measuringtime: 3 sec
                         Common mode                         High Range                        Low Range
                         Input Voltage (mV)              Average Reading (1V)             Average Reading (1V)

     Channel X                            200                      18.92                        16.76
                                         — 200                     —15.78                       —17.08
     Channel Y                            200                      —20.47                       —20.86
                                         — 200                     20.66                        20.31
     Channel Z                            200                      18.43                        18.46
                                         ~ 200                     ~15.65                       ~15.97



 3. Channel separation
     DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec
                        Input Voltage (mV)           Channel X (uV)         Channel Y (uV)     Channel Z (uV)

     Channel X                     200                        —                  0.08               —3.66
     Channel Y                     200                       712                      —              1.80
     Channel Z                     200                    10.44                  4.52                    —


 Certificate No: DAE4—1525_Oct17                              Page 4 of 5




                                                                                          Nn epgrge en n c nnges


()
 S
 4. AD—Converter Values with inputs shorted
    DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec



     Channel X

     Channel Y
                                                    High Range (LSB)

                                                            15817

                                                            16329
                                                                                      Low Range (LSB)

                                                                                             15005

                                                                                             14457
     Channel Z                                              15576                            15478



 5. Input Offset Measurement
    DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec
    Input 10MQ

                            Average (1V)        min. Offset (V)       max. Offset (uV)        Sid: [():\\’l;atlon

     Channel X                   0.63                 »0.54                 2.27                     0.51
     Channel Y                   ~2.07                ~3.42                ~1.02                     0.49
     Channel Z                   —0.89                —2.38                 0.83                     0.54



 6. Input Offset Current
     Nominal Input circuitry offset current on all channels: <25fA


 7. Input Resistance (Typical values for information)
                                                  Zeroing (kOhm)                      Measuring (MOhm)
     Channel X                                             200                                200
     Channel Y                                             200                                200
     Channel Z                                             200                                200



 8. Low Battery Alarm Voltage (Typical values for information)
     Typical values                                Alarm Level (VDC)
     Supply (+ Vee)                                                            +7.9
     Supply (— Vee)                                                            76



 9. Power Consumption (Typical values for information)
     Typical values                         Switched off (mA)        Stand by (mA)        Transmitting (mA)
     Supply (+ Vee)                                +0.01                  +6                        +14
     Supply (— Vec)                                —0.01                  —8                         —9




 Certificate No: DAE4—1525_Oct17                            Page 5 of 5




                                                                                       Ns eperg n ragi esn n en n nge ie >


                                         No. I18Z60493-SEM01
                                             Page 186 of 186


ANNEX J   Accreditation Certificate




                                      ©Copyright. All rights reserved by CTTL.



Document Created: 2018-05-09 13:34:23
Document Modified: 2018-05-09 13:34:23

© 2024 FCC.report