Part 90 Test Report

FCC ID: ZNFX320PM

Test Report

Download: PDF
FCCID_4427940

                                        PCTEST ENGINEERING LABORATORY, INC.
                                                        7185 Oakland Mills Road, Columbia, MD 21046 USA
                                                              Tel. 410.290.6652 / Fax 410.290.6654
                                                                      http://www.pctest.com
                                                               MEASUREMENT REPORT
                                                                             FCC Part 22 & 90

  Applicant Name:                                                                                Date of Testing:
  LG Electronics USA, Inc.                                                                       7/22 - 8/12/2019
  1000 Sylvan Avenue                                                                             Test Site/Location:
  Englewood Cliffs, NJ 07632                                                                     PCTEST Lab. Columbia, MD, USA
  United States                                                                                  Test Report Serial No.:
                                                                                                 1M1907220127-04.ZNF


  FCC ID:                                                            ZNFX320PM
  APPLICANT:                                                         LG Electronics USA, Inc.




  Application Type:                                                  Class II Permissive Change
  Model:                                                             LM-X320PM
  Additional Model(s):                                               LMX320PM, X320PM
  EUT Type:                                                          Portable Handset
  FCC Classification:                                                PCS Licensed Transmitter Held to Ear (PCE)
  FCC Rule Part:                                                     §2.1049, §22(H), §90(S)
  Test Procedure(s):                                                 ANSI C63.26-2015, ANSI/TIA-603-E-2016, KDB 971168 D01 v03r01
  Class II Permissive Change:                                        Please see FCC change document
  Original Grant Date:                                               8/09/2019




  This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report
  and was tested in accordance with the measurement procedures specified in §2.947. Test results reported herein relate only to the item(s)
  tested.

  I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are
  correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the
  qualifications of all persons taking them.




                                                                              MEASUREMENT REPORT                                                                Approved by:
FCC ID: ZNFX320PM
                                                                           (CLASS II PERMISSIVE CHANGE)                                                         Quality Manager
Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                Page 1 of 17
1M1907220127-04.ZNF                    7/22 - 8/12/2019               Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                                               T A B L E                        O F             C O N T E N T S

1.0          INTRODUCTION ........................................................................................................................................... 4
             1.1        Scope ................................................................................................................................................................. 4
             1.2        PCTEST Test Location....................................................................................................................................... 4
             1.3        Test Facility / Accreditations ............................................................................................................................... 4
2.0          PRODUCT INFORMATION........................................................................................................................... 5
             2.1        Equipment Description ....................................................................................................................................... 5
             2.2        Device Capabilities ............................................................................................................................................. 5
             2.3        Test Configuration .............................................................................................................................................. 5
             2.4        EMI Suppression Device(s)/Modifications .......................................................................................................... 5
3.0          DESCRIPTION OF TESTS ........................................................................................................................... 6
             3.1        Evaluation Procedure ......................................................................................................................................... 6
             3.2        Radiated Power and Radiated Spurious Emissions ........................................................................................... 6
4.0          MEASUREMENT UNCERTAINTY ................................................................................................................ 7
5.0          TEST EQUIPMENT CALIBRATION DATA ................................................................................................... 8
6.0          SAMPLE CALCULATIONS ........................................................................................................................... 9
7.0          TEST RESULTS .......................................................................................................................................... 10
             7.1        Summary .......................................................................................................................................................... 10
             7.2        Radiated Power (ERP) ..................................................................................................................................... 11
             7.3        Radiated Spurious Emissions Measurements .................................................................................................. 13
8.0          CONCLUSION ............................................................................................................................................. 17




                                                                               MEASUREMENT REPORT                                                                  Approved by:
FCC ID: ZNFX320PM
                                                                            (CLASS II PERMISSIVE CHANGE)                                                           Quality Manager
Test Report S/N:                       Test Dates:                     EUT Type:
                                                                                                                                                                   Page 2 of 17
1M1907220127-04.ZNF                    7/22 - 8/12/2019               Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                                                         MEASUREMENT REPORT
                                                                        FCC Part 22(H) & 90

                                                                                                                    Max.              Max.
                                                           Tx Frequency
                                Mode                                                    Measurement                Power             Power           Modulation
                                                               (MHz)
                                                                                                                    (W)              (dBm)
                          LTE Band 26                             821.5                 ERP                         0.094            19.71              QPSK
                          LTE Band 26                             821.5                 ERP                         0.079            18.97             16-QAM
                          LTE Band 26                             821.5                 ERP                         0.064            18.08             64-QAM
                                                                                  EUT Overview




                                                                              MEASUREMENT REPORT                                                                Approved by:
FCC ID: ZNFX320PM
                                                                           (CLASS II PERMISSIVE CHANGE)                                                         Quality Manager
Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                Page 3 of 17
1M1907220127-04.ZNF                    7/22 - 8/12/2019               Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


1.0           INTRODUCTION

 1.1           Scope
 Measurement and determination of electromagnetic emissions (EMC) of radio frequency devices including
 intentional and/or unintentional radiators for compliance with the technical rules and regulations of the Federal
 Communications Commission and the Innovation, Science and Economic Development Canada.

 1.2           PCTEST Test Location
 These measurement tests were conducted at the PCTEST Engineering Laboratory, Inc. facility located at 7185
 Oakland Mills Road, Columbia, MD 21046. The measurement facility is compliant with the test site requirements
 specified in ANSI C63.4-2014 and KDB 414788 D01 v01.

 1.3           Test Facility / Accreditations
 Measurements were performed at PCTEST Engineering Lab located in Columbia, MD 21046, U.S.A.

 •     PCTEST is an ISO 17025-2005 accredited test facility under the American Association for Laboratory
       Accreditation (A2LA) with Certificate number 2041.02 for Specific Absorption Rate (SAR), Hearing Aid
       Compatibility (HAC) testing, where applicable, and Electromagnetic Compatibility (EMC) testing for FCC and
       Innovation, Science, and Economic Development Canada rules.

 •     PCTEST TCB is a Telecommunication Certification Body (TCB) accredited to ISO/IEC 17065-2012 by A2LA
       (Certificate number 2041.03) in all scopes of FCC Rules and ISED Standards (RSS).

 •     PCTEST facility is a registered (2451B) test laboratory with the site description on file with ISED.




                                                                               MEASUREMENT REPORT                                                                Approved by:
 FCC ID: ZNFX320PM
                                                                            (CLASS II PERMISSIVE CHANGE)                                                         Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 4 of 17
 1M1907220127-04.ZNF                    7/22 - 8/12/2019               Portable Handset
 © 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
 All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
 microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
 rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


2.0           PRODUCT INFORMATION

 2.1           Equipment Description
 The Equipment Under Test (EUT) is the LG Portable Handset FCC ID: ZNFX320PM. The test data contained in
 this report pertains only to the emissions due to the EUT’s licensed transmitters that operate under the provisions
 of Part 22(H) and 90(S).

 Test Device Serial No.: 13574

 2.2           Device Capabilities
 This device contains the following capabilities:

 800/850/1900 CDMA (BC0, BC1, BC10), 850/1900 GSM/GPRS/EDGE, 850/1700/1900 WCDMA/HSPA, Multi-
 band LTE, 802.11b/g/n WLAN, Bluetooth (1x, EDR, LE)

 2.3              Test Configuration
 The EUT was tested per the guidance of ANSI/TIA-603-E-2016 and KDB 971168 D01 v03r01. See Section 7.0 of
 this test report for a description of the radiated tests.

 2.4           EMI Suppression Device(s)/Modifications
 No EMI suppression device(s) were added and no modifications were made during testing.




                                                                               MEASUREMENT REPORT                                                                Approved by:
 FCC ID: ZNFX320PM
                                                                            (CLASS II PERMISSIVE CHANGE)                                                         Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 5 of 17
 1M1907220127-04.ZNF                    7/22 - 8/12/2019               Portable Handset
 © 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
 All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
 microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
 rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


3.0           DESCRIPTION OF TESTS

 3.1           Evaluation Procedure
 The measurement procedures described in the document titled “Land Mobile FM or PM – Communications
 Equipment – Measurements and Performance Standards” (ANSI/TIA-603-E-2016) and “Procedures for
 Compliance Measurement of the Fundamental Emission Power of Licensed Wideband (> 1 MHz) Digital
 Transmission Systems” (KDB 971168 D01 v03r01) were used in the measurement of the EUT.

 3.2           Radiated Power and Radiated Spurious Emissions
 §2.1053, §90.635, §90(S)
 The radiated test facilities consisted of an indoor 3 meter semi-anechoic chamber used for final measurements
 and exploratory measurements, when necessary. The measurement area is contained within the semi-anechoic
 chamber which is shielded from any ambient interference. The test site inside the chamber is a 6m x 5.2m
 elliptical, obstruction-free area in accordance with Figure 5.7 of Clause 5 in ANSI C63.4-2014. Absorbers are
 arranged on the floor between the turn table and the antenna mast in such a way so as to maximize the reduction
 of reflections for measurements above 1GHz. For measurements below 1GHz, the absorbers are removed. A
 raised turntable is used for radiated measurement. The turn table is a continuously rotatable, remote-controlled,
 metallic turntable and 2 meters (6.56 ft.) in diameter. The turn table is flush with the raised floor of the chamber in
 order to maintain its function as a ground plane. An 80cm tall test table made of Styrodur is placed on top of the
 turn table. A Styrodur pedestal is placed on top of the test table to bring the total table height to 1.5m.
 The equipment under test was transmitting while connected to its integral antenna and is placed on a wooden
 turntable 80cm above the ground plane and 3 meters from the receive antenna. The receive antenna height is
 adjusted between 1 and 4 meter height, the turntable is rotated through 360 degrees, and the EUT is manipulated
 through all orthogonal planes representative of its typical use to achieve the highest reading on the receive
 spectrum analyzer. Radiated power levels are also investigated with the receive antenna horizontally and
 vertically polarized. The maximized power level is recorded using the spectrum analyzer “Channel Power”
 function with the integration band set to the emissions’ occupied bandwidth, a RMS detector, RBW = 100kHz,
 VBW = 300kHz, and a 1 second sweep time over a minimum of 10 sweeps, per the guidelines of KDB 971168
 D01 v03r01.
 Per the guidance of ANSI/TIA-603-E-2016, a half-wave dipole is then substituted in place of the EUT. For
 emissions above 1GHz, a horn antenna is substituted in place of the EUT. The substitute antenna is driven by a
 signal generator with the level of the signal generator being adjusted to obtain the same receive spectrum
 analyzer level previously recorded from the spurious emission from the EUT. The power of the emission is
 calculated using the following formula:
                                                   Pd [dBm] = Pg [dBm] – cable loss [dB] + antenna gain [dBd/dBi]
 Where, Pd is the dipole equivalent power, Pg is the generator output into the substitution antenna, and the
 antenna gain is the gain of the substitute antenna used relative to either a half-wave dipole (dBd) or an isotropic
 source (dBi). The substitute level is equal to Pg [dBm] – cable loss [dB].
 The calculated Pd levels are then compared to the absolute spurious emission limit of -13dBm which is equivalent
 to the required minimum attenuation of 43 + 10 log10(Power [Watts]) specified in 90(S).
 For fundamental radiated power measurements, the guidance of KDB 971168 D01 v03r01 is used to record the
 EUT power level that is subsequently matched via the aforementioned substitution method given in ANSI/TIA-
 603-E-2016.

 All radiated measurements are performed in a chamber that meets the site requirements per ANSI C63.4-2014.
 Additionally, radiated emissions below 30MHz are also validated on an Open Area Test Site to assert correlation
 with the chamber measurements per the requirements of KDB 474788 D01.


                                                                               MEASUREMENT REPORT                                                                Approved by:
 FCC ID: ZNFX320PM
                                                                            (CLASS II PERMISSIVE CHANGE)                                                         Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 6 of 17
 1M1907220127-04.ZNF                    7/22 - 8/12/2019               Portable Handset
 © 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
 All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
 microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
 rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


4.0           MEASUREMENT UNCERTAINTY

 The measurement uncertainties shown below were calculated in accordance with the requirements of
 ANSI C63.4-2014. All measurement uncertainty values are shown with a coverage factor of k = 2 to indicate a
 95% level of confidence. The measurement uncertainty shown below meets or exceeds the UCISPR measurement
 uncertainty values specified in CISPR 16-4-2 and, thus, can be compared directly to specified limits to determine
 compliance.


                                                   Contribution                                        Expanded Uncertainty (±dB)

                                     Radiated Disturbance (<1GHz)                                                            4.98

                                     Radiated Disturbance (>1GHz)                                                            5.07

                                    Radiated Disturbance (>18GHz)                                                            5.09




                                                                               MEASUREMENT REPORT                                                                Approved by:
 FCC ID: ZNFX320PM
                                                                            (CLASS II PERMISSIVE CHANGE)                                                         Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 7 of 17
 1M1907220127-04.ZNF                    7/22 - 8/12/2019               Portable Handset
 © 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
 All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
 microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
 rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


5.0            TEST EQUIPMENT CALIBRATION DATA

Test Equipment Calibration is traceable to the National Institute of Standards and Technology (NIST).
Measurements antennas used during testing were calibrated in accordance to the requirements of ANSI C63.5-
2017.

     Manufacturer                      Model                               Description                             Cal Date       Cal Interval         Cal Due        Serial Number

        Agilent                      N9020A                           MXA Signal Analyzer                         4/20/2019          Annual           4/20/2020 US46470561
        Agilent                       N9030A                      PXA Signal Analyzer (44GHz)                     6/12/2019          Annual           6/12/2020 MY52350166
     Com-Power                        AL-130                     9kHz - 30MHz Loop Antenna                       10/10/2017          Biennial        10/10/2019    121034
     Com-Power                       PAM-103                      Pre-Amplifier (1-1000MHz)                       8/8/2018           Annual           8/8/2019     441128
         Emco                          3115                         Horn Antenna (1-18GHz)                        3/28/2018          Biennial         3/28/2020  9704-5182
        EMCO                         3160-09                       Small Horn (18 - 26.5GHz)                      8/9/2018           Biennial         8/9/2020     135427
     ETS Lindgren                    3164-08                       Quad Ridge Horn Antenna                        2/22/2019          Biennial         2/22/2021    128338
   Rohde & Schwarz                   CMW500                      Radio Communication Tester                                            N/A                         100976
   Rohde & Schwarz                   TS-PR26                       18-26.5 GHz Pre-Amplifier                      9/19/2018          Annual           9/19/2019    100040
   Rohde & Schwarz                    ESU26                      EMI Test Receiver (26.5GHz)                      6/5/2019           Annual           6/5/2020     100342
   Rohde & Schwarz                    ESU40                        EMI Test Receiver (40GHz)                      8/9/2018           Annual           8/9/2019     100348
       Seekonk                        NC-100                         Torque Wrench (8" lb)                        5/10/2018          Biennial         5/10/2020     N/A
        Sunol                        DRH-118                        Horn Antenna (1-18GHz)                        8/11/2017          Biennial         8/11/2019   A050307
        Sunol                           JB5                      Bi-Log Antenna (30M - 5GHz)                      4/19/2018          Biennial         4/19/2020   A051107
        Sunol                        DRH-118                        Horn Antenna (1-18 GHz)                       8/11/2017          Biennial         8/11/2019   A042511
                                                                      Table 5-1. Test Equipment

  Notes:

        1. For equipment listed above that has a calibration date or calibration due date that falls within the test date
           range, care was taken to ensure that this equipment was used after the calibration date and before the
           calibration due date.

        2. Equipment with a calibration date of “N/A” shown in this list was not used to make direct calibrated
           measurements.




                                                                                MEASUREMENT REPORT                                                                Approved by:
  FCC ID: ZNFX320PM
                                                                             (CLASS II PERMISSIVE CHANGE)                                                         Quality Manager
  Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                  Page 8 of 17
  1M1907220127-04.ZNF                    7/22 - 8/12/2019               Portable Handset
  © 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
  All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
  microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
  rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


6.0           SAMPLE CALCULATIONS


 Emission Designator
 QPSK Modulation

        Emission Designator = 8M62G7D

        LTE BW = 8.62 MHz
        G = Phase Modulation
        7 = Quantized/Digital Info
        D = Data transmission, telemetry, telecommand

 16QAM Modulation

        Emission Designator = 8M45W7D

        LTE BW = 8.45 MHz
        W = Amplitude/Angle Modulated
        7 = Quantized/Digital Info
        D = Data transmission, telemetry, telecommand

 Spurious Radiated Emission – LTE Band
 Example: Middle Channel LTE Mode 2nd Harmonic (1564 MHz)

 The average spectrum analyzer reading at 3 meters with the EUT on the turntable was –81.0 dBm. The gain of
 the substituted antenna is 8.1 dBi. The signal generator connected to the substituted antenna terminals is
 adjusted to produce a reading of –81.0 dBm on the spectrum analzyer. The loss of the cable between the signal
 generator and the terminals of the substituted antenna is 2.0 dB at 1564 MHz. So 6.1 dB is added to the signal
 generator reading of –30.9 dBm yielding –24.80 dBm. The fundamental EIRP was 25.501 dBm so this harmonic
 was 25.501 dBm – (-24.80).




                                                                               MEASUREMENT REPORT                                                                Approved by:
 FCC ID: ZNFX320PM
                                                                            (CLASS II PERMISSIVE CHANGE)                                                         Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 9 of 17
 1M1907220127-04.ZNF                    7/22 - 8/12/2019               Portable Handset
 © 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
 All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
 microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
 rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.0           TEST RESULTS

 7.1            Summary

           Company Name:                          LG Electronics USA, Inc.
           FCC ID:                                ZNFX320PM
           FCC Classification:                    PCS Licensed Transmitter Held to Ear (PCE)
           Mode(s):                               CDMA / EvDo / LTE
           Band:                                  Band Class 10 / Band 26



             FCC Part                                                                                                          Test                 Test
                                          Test Description                                 Test Limit                                                              Reference
             Section(s)                                                                                                      Condition             Result

                                    Effective Radiated Power
           22.913(a.2)                                                        < 7 Watts max. ERP                                                    PASS            Section 7.2
                                    (Band 26)
                                                                              > 43 + 10 log10 (P[Watts]) for all
                                                                              out-of-band emissions except                   RADIATED
           2.1053
                                    Radiated Spurious                         > 50 + 10 log10 (P[Watts]) at
           90(S)                                                                                                                                    PASS            Section 7.3
                                    Emissions                                 Band Edge and for all out-of-
           90(R)
                                                                              band emissions within 37.5kHz
                                                                              of Block Edge
                                                                Table 7-1. Summary of Test Results

           Notes:

           1)     All modes of operation and data rates were investigated. The test results shown in the following sections represent
                  the worst case emissions.




                                                                               MEASUREMENT REPORT                                                                Approved by:
 FCC ID: ZNFX320PM
                                                                            (CLASS II PERMISSIVE CHANGE)                                                         Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 10 of 17
 1M1907220127-04.ZNF                    7/22 - 8/12/2019               Portable Handset
 © 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
 All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
 microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
 rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.2          Radiated Power (ERP)
§22.913(a.2) §90.542(a)(7)

Test Overview

Effective Radiated Power (ERP) measurements are performed using the substitution method described in
ANSI/TIA-603-E-2016 with the EUT transmitting into an integral antenna. Measurements on signals operating
below 1GHz are performed using vertically and horizontally polarized tuned dipole antennas. All measurements
are performed as RMS average measurements while the EUT is operating at its maximum duty cycle, at
maximum power, and at the appropriate frequencies.

Test Procedures Used

KDB 971168 D01 v03r01 – Section 5.2.1

ANSI/TIA-603-E-2016 – Section 2.2.17

Test Settings

      1. Radiated power measurements are performed using the signal analyzer’s “channel power” measurement
             capability for signals with continuous operation.
      2. RBW = 1 – 5% of the expected OBW, not to exceed 1MHz

      3. VBW ≥ 3 x RBW

      4. Span = 1.5 times the OBW

      5. No. of sweep points > 2 x span / RBW

      6. Detector = RMS

      7. Trigger is set to “free run” for signals with continuous operation with the sweep times set to “auto”.

      8. The integration bandwidth was roughly set equal to the measured OBW of the signal for signals with

             continuous operation.

      9. Trace mode = trace averaging (RMS) over 100 sweeps

      10. The trace was allowed to stabilize




                                                                              MEASUREMENT REPORT                                                                Approved by:
FCC ID: ZNFX320PM
                                                                           (CLASS II PERMISSIVE CHANGE)                                                         Quality Manager
Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                Page 11 of 17
1M1907220127-04.ZNF                    7/22 - 8/12/2019               Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Test Setup

The EUT and measurement equipment were set up as shown in the diagram below.




                                                            Figure 7-1. Radiated Test Setup <1GHz


Test Notes

      1) The EUT was tested in three orthogonal planes and in all possible test configurations and positioning.
         The worst case emissions are reported with the EUT positioning, modulations, RB sizes and offsets, and
         channel bandwidth configurations shown in the tables below.

      2) This unit was tested with its standard battery.

            Channel                             Ant.     Antenna Turntable             Substitute Ant.
 Frequency                                                                     RB                                            ERP Limit                                            Margin
           Bandwidth               Mod.         Pol.      Height  Azimuth                 Level   Gain ERP [dBm] ERP [Watts]
   [MHz]                                                                   Size/Offset                                        [dBm]                                                [dB]
             [MHz]                             [H/V]       [cm]   [degree]               [dBm]    [dBi]

    821.50            15          QPSK           H          243           285            1/0            15.16        6.70        19.71             0.094            38.45          -18.74

    821.50            15         16-QAM          H          243           285            1/0            14.42        6.70        18.97             0.079            38.45          -19.48

    821.50            15         64-QAM          H          243           285            1/0            13.53        6.70        18.08             0.064            38.45          -20.37

    821.50            15          QPSK           V          236           266            1/0            13.14        6.70        17.69             0.059            38.45          -20.76

                                                                    Table 7-1. ERP Data (Band 26)




                                                                              MEASUREMENT REPORT                                                                Approved by:
FCC ID: ZNFX320PM
                                                                           (CLASS II PERMISSIVE CHANGE)                                                         Quality Manager
Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                Page 12 of 17
1M1907220127-04.ZNF                    7/22 - 8/12/2019               Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.3           Radiated Spurious Emissions Measurements
§2.1053 §90(S)

Test Overview

Radiated spurious emissions measurements are performed using the substitution method described in ANSI/TIA-
603-E-2016 with the EUT transmitting into an integral antenna. Measurements on signals operating below 1GHz
are performed using horizontally and vertically polarized tuned dipole antennas. Measurements on signals
operating above 1GHz are performed using vertically and horizontally polarized broadband horn antennas. All
measurements are performed as peak measurements while the EUT is operating at maximum power, and at the
appropriate frequencies.

Test Procedures Used

KDB 971168 D01 v03r01 – Section 5.8

ANSI/TIA-603-E-2016 – Section 2.2.12

Test Settings

      1. RBW = 100kHz for emissions below 1GHz and 1MHz for emissions above 1GHz

      2. VBW ≥ 3 x RBW

      3. Span = 1.5 times the OBW

      4. No. of sweep points > 2 x span / RBW

      5. Detector = RMS

      6. Trace mode = Average (Max Hold for pulsed emissions)

      7. The trace was allowed to stabilize




                                                                              MEASUREMENT REPORT                                                                Approved by:
FCC ID: ZNFX320PM
                                                                           (CLASS II PERMISSIVE CHANGE)                                                         Quality Manager
Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                Page 13 of 17
1M1907220127-04.ZNF                    7/22 - 8/12/2019               Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Test Setup

The EUT and measurement equipment were set up as shown in the diagram below.




                                                  Figure 7-2. Test Instrument & Measurement Setup

Test Notes

      1. For CDMA mode, this device was tested under all R.C.s and S.O.s and the worst case is reported with
         RC3/SO55 with "All Up" power control bits.

      2. For LTE mode, the device was tested under all modulations, RB sizes and offsets, and channel
         bandwidth configurations and the worst case emissions are reported with 1 RB.

      3. This unit was tested with its standard battery.

      4. The EUT was tested in three orthogonal planes and in all possible test configurations and positioning.
         The worst case setup is reported in the tables below.

      5. The "-" shown in the following RSE tables are used to denote a noise floor measurement.




                                                                              MEASUREMENT REPORT                                                                Approved by:
FCC ID: ZNFX320PM
                                                                           (CLASS II PERMISSIVE CHANGE)                                                         Quality Manager
Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                Page 14 of 17
1M1907220127-04.ZNF                    7/22 - 8/12/2019               Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                                   OPERATING FREQUENCY:                                                 817.90                          MHz
                                                               CHANNEL:                                    476
                                          MODULATION SIGNAL:                             CDMA
                                                              DISTANCE:                       3          meters
                                                                       LIMIT:            -13.00           dBm

                                                                  Level at
                                   Ant.        Antenna Turntable                                             Substitute                     Spurious
           Frequency                                              Antenna                                                                                                  Margin
                                   Pol.         Height  Azimuth                                             Antenna Gain                  Emission Level
             [MHz]                                               Terminals                                                                                                  [dB]
                                  [H/V]          [cm]   [degree]                                                [dBi]                         [dBm]
                                                                   [dBm]
              1635.80                H            160     129      -50.13                                           3.59                          -46.54                     -33.5
              2453.70                H              166                 136              -60.81                     4.17                          -56.64                     -43.6
              3271.60                H                 -                  -              -62.12                     5.69                          -56.43                     -43.4
              4089.50                H            -         -      -67.46         7.52            -59.94                                                                     -46.9
                                             Table 7-2. CDMA BC10 Radiated Spurious Data (Ch.476)

                                OPERATING FREQUENCY:                                                 823.10                          MHz
                                                           CHANNEL:                                    684
                                      MODULATION SIGNAL:                             CDMA
                                                           DISTANCE:                      3          meters
                                                                   LIMIT:            -13.00          dBm

                                                               Level at
                               Ant.         Antenna Turntable                                            Substitute                      Spurious
        Frequency                                              Antenna                                                                                                 Margin
                               Pol.          Height  Azimuth                                            Antenna Gain                   Emission Level
          [MHz]                                               Terminals                                                                                                 [dB]
                              [H/V]           [cm]   [degree]                                               [dBi]                          [dBm]
                                                                [dBm]
          1646.20                H             156     270      -51.41                                           3.60                          -47.81                    -34.8
          2469.30                H              163                 314              -65.56                      4.21                          -61.35                    -48.4
          3292.40                H                 -                  -              -60.86                      5.76                          -55.11                    -42.1
          4115.50                H             -          -      -69.67        7.58             -62.09                                                                   -49.1
                                            Table 7-3. CDMA BC10 Radiated Spurious Data (Ch. 684)




                                                                                 MEASUREMENT REPORT                                                             Approved by:
FCC ID: ZNFX320PM
                                                                              (CLASS II PERMISSIVE CHANGE)                                                      Quality Manager
Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                Page 15 of 17
1M1907220127-04.ZNF                    7/22 - 8/12/2019               Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                                   OPERATING FREQUENCY:                                                 816.50                           MHz
                                      MODULATION SIGNAL:                                 QPSK
                                                          BANDWIDTH:                        5.0          MHz
                                                              DISTANCE:                      3           meters
                                                                       LIMIT:            -13.00           dBm

                                                                  Level at
                                  Ant.         Antenna Turntable                                             Substitute                     Spurious
           Frequency                                              Antenna                                                                                                  Margin
                                  Pol.          Height  Azimuth                                             Antenna Gain                  Emission Level
             [MHz]                                               Terminals                                                                                                  [dB]
                                 [H/V]           [cm]   [degree]                                                [dBi]                         [dBm]
                                                                   [dBm]
              1633.00                H            117     310      -51.92                                           8.83                           -43.09                    -30.1
              2449.50                H              132                325               -62.48                     9.53                           -52.95                    -40.0
              3266.00                H              122                 57               -67.52                     9.53                           -57.99                    -45.0
              4082.50                H                -                   -              -73.23                    10.01                           -63.22                    -50.2
              4899.00                H          -           -      -72.81        10.81           -62.01                                                                      -49.0
                                         Table 7-4. Radiated Spurious Data (LTE Band 26 – Low Channel)

                                   OPERATING FREQUENCY:                                                 821.50                           MHz
                                          MODULATION SIGNAL:                             QPSK
                                                          BANDWIDTH:                        5.0          MHz
                                                              DISTANCE:                      3           meters
                                                                       LIMIT:            -13.00          dBm

                                                                  Level at
                                  Ant.         Antenna Turntable                                             Substitute                     Spurious
           Frequency                                              Antenna                                                                                                  Margin
                                  Pol.          Height  Azimuth                                             Antenna Gain                  Emission Level
             [MHz]                                               Terminals                                                                                                  [dB]
                                 [H/V]           [cm]   [degree]                                                [dBi]                         [dBm]
                                                                   [dBm]
              1643.00                H            111     306      -50.62                                           8.93                           -41.69                    -28.7
              2464.50                H              121                319               -65.23                     9.63                           -55.60                    -42.6
              3286.00                H              124                320               -66.84                     9.57                           -57.27                    -44.3
              4107.50                H                -                   -              -72.90                    10.16                           -62.74                    -49.7
              4929.00                H           -          -       -72.47        10.89           -61.58                                                                     -48.6
                                         Table 7-5. Radiated Spurious Data (LTE Band 26 – High Channel)




                                                                                 MEASUREMENT REPORT                                                             Approved by:
FCC ID: ZNFX320PM
                                                                              (CLASS II PERMISSIVE CHANGE)                                                      Quality Manager
Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                Page 16 of 17
1M1907220127-04.ZNF                    7/22 - 8/12/2019               Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


8.0           CONCLUSION

 The data collected relate only to the item(s) tested and show that the LG Portable Handset
 FCC ID: ZNFX320PM complies with all the requirements of Parts 22(H) and 90 of the FCC rules.




                                                                               MEASUREMENT REPORT                                                                Approved by:
 FCC ID: ZNFX320PM
                                                                            (CLASS II PERMISSIVE CHANGE)                                                         Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 17 of 17
 1M1907220127-04.ZNF                    7/22 - 8/12/2019               Portable Handset
 © 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
 All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
 microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
 rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.



Document Created: 2019-09-04 12:01:49
Document Modified: 2019-09-04 12:01:49

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC