ZNFX240DS_TestRpt_RFExp_20170329

FCC ID: ZNFX240DS

RF Exposure Info

Download: PDF
FCCID_3349762

          FCC SAR Test Report                                                        Report No. : FA6D1019




                            FCC SAR Test Report

                         APPLICANT            : LG Electronics Mobile Comm USA
                         EQUIPMENT            : Smart phone
                         BRAND NAME           : LG
                         MODEL NAME           : LG-X240ds
                         FCC ID               : ZNFX240DS
                         STANDARD             : FCC 47 CFR Part 2 (2.1093)
                                                ANSI/IEEE C95.1-1992
                                                IEEE 1528-2013

      We, SPORTON INTERNATIONAL INC., would like to declare that the tested sample has been
      evaluated in accordance with the procedures and had been in compliance with the
      applicable technical standards.

      The test results in this report apply exclusively to the tested model / sample. Without
      written approval of SPORTON INTERNATIONAL INC., the test report shall not be
      reproduced except in full.




           Reviewed by: Eric Huang / Manager




           Approved by: Jones Tsai / Manager



                                  SPORTON INTERNATIONAL INC.
No.52, Hwa Ya 1st Rd., Hwa Ya Technology Park, Kwei-Shan District, Taoyuan City, Taiwan (R.O.C.)




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                   Issued Date : Mar. 29, 2017
FCC ID : ZNFX240DS                                   Page 1 of 12            Form version. : 160427


              FCC SAR Test Report                                                                                                                 Report No. : FA6D1019

                                                                Table of Contents
1. Statement of Compliance ............................................................................................................................................. 4
2. Administration Data ...................................................................................................................................................... 4
3. Guidance Applied .......................................................................................................................................................... 5
4. Equipment Under Test (EUT) Information ................................................................................................................... 5
     4.1 General Information ............................................................................................................................................... 5
     4.2 Spot Check Evaluation ........................................................................................................................................... 6
5. Antenna Location .......................................................................................................................................................... 9
6. Uncertainty Assessment .............................................................................................................................................10
7. References ....................................................................................................................................................................12
Appendix A. Reference Report
Appendix B. SAR Spot Check Data
Appendix C. SAR Test Setup Photos




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                                                                            Issued Date : Mar. 29, 2017
FCC ID : ZNFX240DS                                                                   Page 2 of 12                                     Form version. : 160427


          FCC SAR Test Report                                                      Report No. : FA6D1019



                                              Revision History
   REPORT NO.           VERSION                              DESCRIPTION              ISSUED DATE

     FA6D1019             Rev. 01       Initial issue of report                        Mar. 23, 2017

     FA6D1019             Rev. 02       Revised typo on page 7                         Mar. 29, 2017




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                 Issued Date : Mar. 29, 2017
FCC ID : ZNFX240DS                                         Page 3 of 12    Form version. : 160427


            FCC SAR Test Report                                                                  Report No. : FA6D1019
1. Statement of Compliance
The maximum results of Specific Absorption Rate (SAR) found during testing for LG Electronics Mobile
Comm USA, Smart phone, LG-X240ds, are as follows.


                                                             Highest SAR Summary                          Highest
    Equipment            Frequency                 Head            Body-worn          Hotspot          Simultaneous
      Class                Band               (Separation 0mm) (Separation 15mm) (Separation 10mm)     Transmission
                                                                 1g SAR (W/kg)                        1g SAR (W/kg)
                          GSM850                    0.61              0.63              0.83
                         GSM1900                    0.14              0.18              0.32
     Licensed
                         WCDMA V                    0.46              0.54              0.64                1.59
                        LTE Band 7                  0.59              1.13              0.57
       DTS             2.4GHz WLAN                  0.98              0.05              0.12

This device is in compliance with Specific Absorption Rate (SAR) for general population/uncontrolled
exposure limits (1.6 W/kg) specified in FCC 47 CFR part 2 (2.1093) and ANSI/IEEE C95.1-1992, and had
been tested in accordance with the measurement methods and procedures specified in IEEE 1528-2013 and
FCC KDB publications




2. Administration Data
                                                   Testing Laboratory
Test Site                          SPORTON INTERNATIONAL INC.
                                   No.52, Hwa Ya 1st Rd., Hwa Ya Technology Park, Kwei-Shan District, Taoyuan City,
                                   Taiwan (R.O.C.)
Test Site Location
                                   TEL: +886-3-327-3456
                                   FAX: +886-3-328-4978

                                                          Applicant
Company Name                      LG Electronics Mobile Comm USA
Address                           LG Twin Towers 20, Yeouido-Dong Youngdeungpo-Gu, Seoul 150-721, Republic Of
                                  Korea

                                                        Manufacturer
Company Name                      Arima Communications Corp.
Address                           6F,No.866,Jhongjheng Rd., Jhonghe Dist., New Taipei City 23586, Taiwan




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                               Issued Date : Mar. 29, 2017
FCC ID : ZNFX240DS                                          Page 4 of 12                 Form version. : 160427


seorrow cas._FCC SAR Test Report                                                                      Report No. : FA6D1019
  3. Guidance Applied
       The Specific Absorption Rate (SAR) testing specification, method, and procedure for this device is in accordance with
       the following standards:
       >     FCC 47 CFR Part 2 (2.1093)
             ANSVIEEE C95.1—1992
             IEEE 1528—2013
             FCC KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz v01r04
             FCC KDB 865664 D02 SAR Reporting v01r02
             FCC KDB 447498 DO1 General RF Exposure Guidance v06
             FCC   KDB   648474   D04   SAR Evaluation Considerations for Wireless Handsets v01r03
             FCC   KDB   248227   D01   802.11 Wi—Fi SAR v02r02
             FCC   KDB   941225   D01   3G SAR Procedures v08r01
             FCC   KDB   941225   DO5   SAR for LTE Devices v02r05
             FCC   KDB   941225   D06   Hotspot Mode SAR v02r01



  4. Equipment Under Test (EUT) Information

  4.1 General Information
                                                Product Feature & Specification
  Equipment Name                  Smart phone
  Brand Name                      LG
  Model Name                      LG—X240ds
  FCC ID                          ZNFX240DS
                                  GSMB50: 824.2 MHz ~ 848.8 MHz
                                  GSM1900: 1850.2 MHz ~ 1909.8 MHz
  WUbS C—OMUCe ieR pELCIWCDMA Band V: 826.4 MHz ~ 846.6 MHz
  Frequency Range       LTE Band 7: 2502.5 MHz ~ 2567.5 MHz
                       WLAN 2.4GHz Band: 2412 MHz ~ 2462 MHz
                        Bluetooth: 2402 MHz ~ 2480 MHz
                       GSMGPRS/EGPRS
                        RMC/AMR 12.2Kbps




                                  LTE: QPSK, 16QAM
                                  802.11b/g/n HT20/HT4O
                                  Bluetooth BR/EDR/LE
  HW Version                      DV
  SW Version                      LGX240dsAT—00—V08a—CIS—XX— NOV—17—2016+0
  lesil in (3)|el al stsMibe hSi(zil Class B — EUT cannot support Packet Switched and Circuit Switched Network
  mode                            simultaneously but can automatically switch between Packet and Circuit Switched Network.
  EUT Stage                       Production Unit
  Remark:
  1.   The device has two SIM slots and supports Dual SIM Dual Standby. The WWAN radio transmission will be enabled by
       either one SIM at a time (Single active).
       This device 2.4GHz WLAN supports Hotspot operation.
       When hotspot mode is enabled, power reduction will be activated to limit the maximum power of LTE band 7.
       In this report,
       (a) GSMB50/1900, UMTS B5 and LTE B7 test results are referred to LG—X240YK (FCC ID: ZNFX240YK}, Sporton
           Report No: FAGD1013 or Appendix A—1/A—2, and spot checks were performed on LG—X240ds to ensure that the
           SAR measurements for both devices are the same.
       (b) WLAN / BT SAR test results are referred to LG—X240H (FCC ID: ZNFX240H), Sporton Report No: FA6O1802 or
           Appendix A—3/A—4/A—5, and spot checks were performed on LG—X240ds to ensure that the SAR measurements for
           both devices are the same.


  SPORTON INTERNATIONAL INC.
  TEL : 886—3—327—3456 / FAX : 886—3—328—4978                                                 Issued Date : Mar. 29, 2017
  FCC ID : ZNFX240D8                                          Page 5 of 12                   Form version. : 160427


      FCC SAR Test Report                                                                    Report No. : FA6D1019
4.2 Spot Check Evaluation

1. Introduction Section
    For WWAN :
       This report referenced from the FCC ID: ZNFX240YK
       (GSM 850 / 1900, WCDMA Band 5 and LTE Band 7)

    For WLAN/BT :
       This report referenced from the FCC ID: ZNFX240H
       (DTS and DSS)

    The applicant takes full responsibility that the test data as referenced in this report represent compliance
    for this FCC ID (FCC ID: ZNFX240DS).


2. Difference Section
    For WWAN:
    (FCC ID: ZNFX240DS, model: LG-X240ds) is a variant model of (FCC ID: ZNFX240YK, model:
    LG-X240YK) with removed LTE Band 5, and all the divergent bands have been properly tested to ensure
    compliance. The detailed comparison of (FCC ID: ZNFX240DS, model: LG-X240ds) and (FCC ID:
    ZNFX240YK, model: LG-X240YK) is included in the OpDes_Data Reuse.


    For WLAN/BT:
    The original model (FCC ID: ZNFX240H) and the variant model (FCC ID: ZNFX240DS) has identical PCB
    layout, antenna, SW implementation for Bluetooth/Wi-Fi. The details comparison can be found in the
    Produce Equality Declaration.


    The product specification is outlined in the following table:

FCC ID                                              ZNFX240H                 ZNFX240YK             ZNFX240DS
Wireless Tech         Mode                                                Frequency (MHz)
GSM                   GSM Voice     Multi-Slot      850/1900                 850/1900              850/1900
                      GPRS          Class 12
                      (GMSK)        DTM: No
                      EDGE
                      (8PSK)
UMTS                  AMR/RCM12.2Kbps               B2/B4/B5                 B5                    B5
                      HSDPA/HSUPA/DC-HSDPA
LTE (FDD)             QPSK                          B2/B4/B5/B7/B13/B17      B5/B7                 B7
                      16QAM
Wi-Fi                 11b/11g/11n(HT20/HT40)        2412-2462
Bluetooth             BR/EDR/LE                     2402-2480 MHz




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                           Issued Date : Mar. 29, 2017
FCC ID : ZNFX240DS                                    Page 6 of 12                   Form version. : 160427


                  FCC SAR Test Report                                                                                              Report No. : FA6D1019
            3. Spot Check Verification Data Section
            <Head SAR>
                                                                                Original Model(FCC ID: X240YK)    Spot Check Mode(FCC ID: X240DS)
                                           Test        Gap             Freq. Average Tune-Up Measured Reported Average Tune-Up Measured Reported
     Band                Mode                                Ch.                                                                                   Deviation
                                          Position    (mm)             (MHz) Power      Limit   1g SAR 1g SAR Power       Limit   1g SAR 1g SAR
                                                                              (dBm) (dBm)       (W/kg)    (W/kg) (dBm) (dBm)      (W/kg)    (W/kg)
   GSM850          GPRS (4 Tx slots)     Right Cheek 0mm     251       848.8 27.93     28.00     0.603     0.613  28.00   28.00    0.541     0.541  -11.7%
   GSM1900         GPRS (4 Tx slots)     Left Cheek 0mm      810 1909.8        24.92     25.00     0.138     0.141     25.00     25.00     0.136     0.136    -3.5%
   WCDMA V          RMC 12.2Kbps         Right Cheek 0mm 4233 846.6            24.98     25.00     0.459     0.461     25.00     25.00     0.407     0.407    -11.7%
  LTE Band 7       20M_QPSK_1_0          Left Cheek 0mm 20850 2510             23.24     23.30     0.579     0.587     23.18     23.30     0.458     0.471    -19.8%

                                                        Original Model (FCC ID: ZNFX240H)        Spot Check Mode(FCC ID: X240DS)
                                 Test Gap     Freq. Average Tune-Up Duty Measured Reported Average Tune-Up Duty Measured Reported
   Band        Mode                       Ch.                                                                                       Deviation
                                Position
                                     (mm)     (MHz) Power     Limit Cycle 1g SAR 1g SAR Power          Limit Cycle 1g SAR 1g SAR
                                                     (dBm) (dBm)        %    (W/kg)   (W/kg) (dBm) (dBm)       %   (W/kg)    (W/kg)
WLAN2.4GHz 802.11b 1Mbps Right Cheek 0mm 6 2437 16.97         17.00   100     0.970    0.977  16.97   17.00   100   0.936     0.942  -3.6%


            <Hotspot SAR>
                                                                                Original Model(FCC ID: X240YK)   Spot Check Mode(FCC ID: X240DS)
                                 Test     Gap  Power                   Freq. Average Tune-Up Measured Reported Average Tune-Up Measured Reported
   Band           Mode                                  Ch.                                                                                       Deviation
                                Position (mm) Reduction                (MHz) Power      Limit   1g SAR 1g SAR Power      Limit   1g SAR 1g SAR
                                                                              (dBm) (dBm)       (W/kg)    (W/kg) (dBm) (dBm)     (W/kg)    (W/kg)
 GSM850     GPRS (4 Tx slots)    Back     10mm       OFF         251   848.8   27.93     28.00     0.819     0.832     28.00     28.00     0.742     0.742    -10.8%
 GSM1900 GPRS (4 Tx slots)       Front    10mm       OFF         810 1909.8    24.92     25.00     0.315     0.321     25.00     25.00     0.264     0.264    -17.8%
WCDMA V        RMC 12.2Kbps      Back     10mm       OFF     4233 846.6        24.98     25.00     0.638     0.641     25.00     25.00     0.624     0.624    -2.7%
LTE Band 7 20M_QPSK_50_0         Back     10mm       ON      20850 2510        18.27     18.30     0.565     0.569     18.26     18.30     0.470     0.474    -16.7%

                                                     Original Model (FCC ID: ZNFX240H)        Spot Check Mode(FCC ID: X240DS)
                          Test     Gap     Freq. Average Tune-Up Duty Measured Reported Average Tune-Up Duty Measured Reported
    Band        Mode                   Ch.                                                                                       Deviation
                         Position (mm)     (MHz) Power     Limit Cycle 1g SAR 1g SAR Power          Limit Cycle 1g SAR 1g SAR
                                                  (dBm) (dBm)        %    (W/kg)   (W/kg) (dBm) (dBm)       %   (W/kg)    (W/kg)
 WLAN2.4GHz 802.11b 1Mbps Front 10mm 6 2437 16.97          17.00   100     0.123    0.124  16.97   17.00   100   0.111     0.112  -9.7%


            <Body-Worn SAR>
                                                                            Original Model(FCC ID: X240YK)    Spot Check Mode(FCC ID: X240DS)
                                        Test       Gap             Freq. Average Tune-Up Measured Reported Average Tune-Up Measured Reported
    Band              Mode                                 Ch.                                                                                 Deviation
                                       Position   (mm)             (MHz) Power      Limit   1g SAR 1g SAR Power        Limit  1g SAR 1g SAR
                                                                          (dBm)    (dBm)    (W/kg)    (W/kg) (dBm)    (dBm)   (W/kg)    (W/kg)
   GSM850       GPRS (4 Tx slots)        Back     15mm 251         848.8 27.93      28.00    0.619     0.629  28.00    28.00   0.546     0.546  -13.2%
  GSM1900       GPRS (4 Tx slots)        Front    15mm 810 1909.8          24.92       25.00     0.177     0.180     25.00     25.00     0.148     0.148     -17.8%
  WCDMA V        RMC 12.2Kbps            Back     15mm 4233 846.6          24.98       25.00     0.540     0.542     25.00     25.00     0.527     0.527     -2.8%
  LTE Band 7     20M_QPSK_1_0            Back     15mm 21350 2560          21.92       22.00     1.110     1.131     21.99     22.00     0.920     0.922     -18.5%

                                                     Original Model (FCC ID: ZNFX240H)        Spot Check Mode(FCC ID: X240DS)
                          Test     Gap     Freq. Average Tune-Up Duty Measured Reported Average Tune-Up Duty Measured Reported
    Band            Mode               Ch.                                                                                       Deviation
                         Position (mm)     (MHz) Power     Limit Cycle 1g SAR 1g SAR Power          Limit Cycle 1g SAR 1g SAR
                                                  (dBm) (dBm)        %    (W/kg)   (W/kg) (dBm) (dBm)       %   (W/kg)    (W/kg)
 WLAN2.4GHz 802.11b 1Mbps Back 15mm 6 2437 16.97           17.00   100     0.051    0.051  16.97   17.00   100   0.045     0.045  -11.8%

            Note:
            1. The spot check verification shows the WWAN SAR performance of X240YK represents the performance of X240DS.
            2. The spot check verification shows the WLAN SAR performance of ZNFX240H represents the performance of X240DS.




            SPORTON INTERNATIONAL INC.
            TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                                                   Issued Date : Mar. 29, 2017
            FCC ID : ZNFX240DS                                                     Page 7 of 12                          Form version. : 160427


      FCC SAR Test Report                                                                       Report No. : FA6D1019
4. Reference detail Section

  Rule    Frequency Band       Wireless       Reference        Reference        Reference          Reference
  Part        (MHz)           Technology       FCC ID          Report Title     Report No.       Report Sections

                                                                                                Sections related to
   22      824.2 ~ 848.8       GSM 850        ZNFX240YK   FCC SAR Test Report   FA6D1013
                                                                                                GSM 850 test data
                                                                                                Sections related to
   24     1850.2 ~ 1909.8     GSM 1900        ZNFX240YK   FCC SAR Test Report   FA6D1013
                                                                                               GSM 1900 test data
                                                                                                Sections related to
   22      826.4 ~ 846.6     WCDMA B5         ZNFX240YK   FCC SAR Test Report   FA6D1013
                                                                                               WCDMA B5 test data
                                                                                                Sections related to
   27     2502.5 ~ 2567.5       LTE B7        ZNFX240YK   FCC SAR Test Report   FA6D1013
                                                                                                 LTE B7 test data
                                                                                                Sections related to
  15C        2402~2480         Bluetooth      ZNFX240H    FCC SAR Test Report   FA6O1802
                                                                                                Bluetooth test data
                                                                                                Sections related to
  15C        2412~2462           Wi-Fi        ZNFX240H    FCC SAR Test Report   FA6O1802
                                                                                                  WiFi test data




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                              Issued Date : Mar. 29, 2017
FCC ID : ZNFX240DS                                        Page 8 of 12                  Form version. : 160427


          FCC SAR Test Report                                                                                Report No. : FA6D1019
5. Antenna Location
<Mobile Phone>
                                                             Top Side
                                                               73mm

                                                  WLAN/BT
                                                  Antenna




                                                       Display screen




                        Left                                                                        Right
                                 147mm
                        Side                                                                        Side
                                                  WWAN
                                                 Antenna 2




                                                 157mm                       127mm


                                                                                                    Overall diagonal: 157mm
                                                              WWAN
                                                             Antenna 1                              Display diagonal: 127mm



                                                         Bottom Side                                              Front View


                                     WWAN Antenna                  Support Band
                                                         GSM 850 / 1900,
                                    WWAN Antenna 1
                                                         WCDMA B5
                                    WWAN Antenna 2       LTE B7


                                        Distance of the Antenna to the EUT surface/edge
           Antennas                  Back            Front            Top Side        Bottom Side      Right Side       Left Side
       WWAN Antenna 1              ≤ 25mm           ≤ 25mm            138 mm           ≤ 25mm           ≤ 25mm          ≤ 25mm
       WWAN Antenna 2              ≤ 25mm           ≤ 25mm              75 mm           35 mm            66 mm          ≤ 25mm
          BT / WLAN                ≤ 25mm           ≤ 25mm            ≤ 25mm           130 mm            64 mm          ≤ 25mm


                                              Positions for SAR tests; Hotspot mode
           Antennas                  Back            Front            Top Side        Bottom Side      Right Side       Left Side
       WWAN Antenna 1                Yes              Yes                No              Yes                Yes           Yes
       WWAN Antenna 2                Yes              Yes                No               No                No            Yes
          BT / WLAN                  Yes              Yes                Yes              No                No            Yes
General Note:
1.  Referring to KDB 941225 D06 v02r01, when the overall device length and width are ≥ 9cm*5cm, the test distance is
    10 mm. SAR must be measured for all sides and surfaces with a transmitting antenna located within 25mm from that
    surface or edge



SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                                          Issued Date : Mar. 29, 2017
FCC ID : ZNFX240DS                                            Page 9 of 12                          Form version. : 160427


          FCC SAR Test Report                                                                         Report No. : FA6D1019
6. Uncertainty Assessment
    The component of uncertainly may generally be categorized according to the methods used to evaluate them. The
    evaluation of uncertainly by the statistical analysis of a series of observations is termed a Type An evaluation of
    uncertainty. The evaluation of uncertainty by means other than the statistical analysis of a series of observation is
    termed a Type B evaluation of uncertainty. Each component of uncertainty, however evaluated, is represented by an
    estimated standard deviation, termed standard uncertainty, which is determined by the positive square root of the
    estimated variance.

    A Type A evaluation of standard uncertainty may be based on any valid statistical method for treating data. This
    includes calculating the standard deviation of the mean of a series of independent observations; using the method of
    least squares to fit a curve to the data in order to estimate the parameter of the curve and their standard deviations; or
    carrying out an analysis of variance in order to identify and quantify random effects in certain kinds of measurement.

    A type B evaluation of standard uncertainty is typically based on scientific judgment using all of the relevant
    information available. These may include previous measurement data, experience, and knowledge of the behavior
    and properties of relevant materials and instruments, manufacture’s specification, data provided in calibration reports
    and uncertainties assigned to reference data taken from handbooks. Broadly speaking, the uncertainty is either
    obtained from an outdoor source or obtained from an assumed distribution, such as the normal distribution,
    rectangular or triangular distributions indicated in table below.

       Uncertainty Distributions              Normal             Rectangular           Triangular            U-Shape
                                 (a)                  (b)
           Multi-plying Factor                  1/k                   1/√                  1/√6                 1/√
    (a) standard uncertainty is determined as the product of the multiplying factor and the estimated range of
        variations in the measured quantity
    (b) κ is the coverage factor
                             Table 6.1. Standard Uncertainty for Assumed Distribution

    The combined standard uncertainty of the measurement result represents the estimated standard deviation of the
    result. It is obtained by combining the individual standard uncertainties of both Type A and Type B evaluation using
    the usual “root-sum-squares” (RSS) methods of combining standard deviations by taking the positive square root of
    the estimated variances.

    Expanded uncertainty is a measure of uncertainty that defines an interval about the measurement result within which
    the measured value is confidently believed to lie. It is obtained by multiplying the combined standard uncertainty by a
    coverage factor. Typically, the coverage factor ranges from 2 to 3. Using a coverage factor allows the true value of a
    measured quantity to be specified with a defined probability within the specified uncertainty range. For purpose of this
    document, a coverage factor two is used, which corresponds to confidence interval of about 95 %. The DASY
    uncertainty Budget is shown in the following tables.




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                                    Issued Date : Mar. 29, 2017
FCC ID : ZNFX240DS                                          Page 10 of 12                     Form version. : 160427


          FCC SAR Test Report                                                                    Report No. : FA6D1019

                                     Uncertainty                                           Standard         Standard
                                                                           (Ci)   (Ci)
        Error Description              Value       Probability   Divisor                  Uncertainty     Uncertainty
                                                                            1g    10g
                                        (±%)                                               (1g) (±%)       (10g) (±%)
      Measurement System
         Probe Calibration               6.00           N          1        1      1           6.0             6.0
           Axial Isotropy                4.70           R        1.732     0.7    0.7          1.9             1.9
      Hemispherical Isotropy             9.60           R        1.732     0.7    0.7          3.9             3.9
         Boundary Effects                1.00           R        1.732      1      1           0.6             0.6
             Linearity                   4.70           R        1.732      1      1           2.7             2.7
     System Detection Limits             1.00           R        1.732      1      1           0.6             0.6
      Modulation Response                4.68           R        1.732      1      1           2.7             2.7
       Readout Electronics               0.30           N          1        1      1           0.3             0.3
          Response Time                  0.00           R        1.732      1      1           0.0             0.0
         Integration Time                2.60           R        1.732      1      1           1.5             1.5
        RF Ambient Noise                 3.00           R        1.732      1      1           1.7             1.7
     RF Ambient Reflections              3.00           R        1.732      1      1           1.7             1.7
         Probe Positioner                0.40           R        1.732      1      1           0.2             0.2
        Probe Positioning                2.90           R        1.732      1      1           1.7             1.7
          Max. SAR Eval.                 2.00           R        1.732      1      1           1.2             1.2
      Test Sample Related
        Device Positioning               3.03           N          1        1      1           3.0             3.0
          Device Holder                  3.60           N          1        1      1           3.6             3.6
            Power Drift                  5.00           R        1.732      1      1           2.9             2.9
          Power Scaling                  0.00           R        1.732      1      1           0.0             0.0
       Phantom and Setup
       Phantom Uncertainty               6.10           R        1.732      1      1           3.5            3.5
          SAR correction                 0.00           R        1.732      1     0.84         0.0            0.0
Liquid Conductivity Repeatability        0.03           N          1       0.78   0.71         0.0            0.0
   Liquid Conductivity (target)          5.00           R        1.732     0.78   0.71         2.3            2.0
    Liquid Conductivity (mea.)           2.50           R        1.732     0.78   0.71         1.1            1.0
    Temp. unc. - Conductivity            3.68           R        1.732     0.78   0.71         1.7            1.5
 Liquid Permittivity Repeatability       0.02           N          1       0.23   0.26         0.0            0.0
    Liquid Permittivity (target)         5.00           R        1.732     0.23   0.26         0.7            0.8
     Liquid Permittivity (mea.)          2.50           R        1.732     0.23   0.26         0.3            0.4
     Temp. unc. - Permittivity           0.84           R        1.732     0.23   0.26         0.1            0.1
                                 Combined Std. Uncertainty                                    11.6%          11.6%
                                  Coverage Factor for 95 %                                     K=2            K=2
                                 Expanded STD Uncertainty                                     23.2%          23.1%
                      Table 6.2. Uncertainty Budget for frequency range 300 MHz to 3 GHz




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                               Issued Date : Mar. 29, 2017
FCC ID : ZNFX240DS                                      Page 11 of 12                    Form version. : 160427


          FCC SAR Test Report                                                         Report No. : FA6D1019
7. References
       [1]   FCC 47 CFR Part 2 “Frequency Allocations and Radio Treaty Matters; General Rules and
             Regulations”
       [2]   ANSI/IEEE Std. C95.1-1992, “IEEE Standard for Safety Levels with Respect to Human Exposure
             to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz”, September 1992
       [3]   IEEE Std. 1528-2013, “IEEE Recommended Practice for Determining the Peak Spatial-Average
             Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices:
             Measurement Techniques”, Sep 2013
       [4]   SPEAG DASY System Handbook
       [5]   FCC KDB 248227 D01 v02r02, “SAR Guidance for IEEE 802.11 (WiFi) Transmitters”, Oct 2015.
       [6]   FCC KDB 447498 D01 v06, “Mobile and Portable Device RF Exposure Procedures and
             Equipment Authorization Policies”, Oct 2015
       [7]   FCC KDB 648474 D04 v01r03, “SAR Evaluation Considerations for Wireless Handsets”, Oct
             2015.
       [8]   FCC KDB 941225 D01 v03r01, “3G SAR MEAUREMENT PROCEDURES”, Oct 2015
       [9]   FCC KDB 941225 D05 v02r05, “SAR Evaluation Considerations for LTE Devices”, Dec 2015
       [10] FCC KDB 941225 D06 v02r01, "SAR Evaluation Procedures for Portable Devices with Wireless
             Router Capabilities", Oct 2015.
       [11] FCC KDB 865664 D01 v01r04, "SAR Measurement Requirements for 100 MHz to 6 GHz", Aug
             2015.
       [12] FCC KDB 865664 D02 v01r02, “RF Exposure Compliance Reporting and Documentation
             Considerations” Oct 2015.




SPORTON INTERNATIONAL INC.