Test Report 2

FCC ID: ZNFX210APM

Test Report

Download: PDF
FCCID_3712391

     H.a-                     74, Seoicheon—ro 578beon—gil, Majang—myeon, Icheon—si, Gyeonggi—do, Korea
      HEFCOLETD                        TEL: +82—31—645—6300            FAX: +82—31—645—6401



                                   EMI TEST REPORT
                                       FCC CERTIFICATION

  Apolicent                                                   Date of Receipt: November 01, 2017
  LG Electronics MobileComm U.S.A., Inc.
  1000 Sylvan Avenue, Englewood Cliffs NJ 07632               Pate of Issue: January 05, 2018
  Unite States                                                Test Report No. HCT—EM—1801—FCOO2—R1



          FCC ID:                                     ZNFX210APM


  Rule Part(s) / Standard(s):               FCC CFR 47 PART 15 Subpart B Class B
  FCC Classification:                       JBP (Part 15 B—Class B Computing Device Peripheral)
  EUT Type:                                 GSM/WCDMA/LTE phone with Bluetooth and WLAN
  Model Name:                               LM—X210APM
  Additional Model Name:                    LMX210APM, X210APM, LM—X210CM, LMX210CM,
                                            X210CM, LM—X210CMR, LMX210CMR, X210CMR
  TA Model Name / Manufacturer:             MCS—02WDE / DONGDO

  Date of Test:                             November 06, 2017 — November 17, 2017


 The device bearing the trade name and model specified above, has been shown to comply with the
 applicable technical standards as indicated in the measurement report and was tested in accordance with
 the measurement procedures specified in ANSI C63.4—2014. (See Test Report if any modifications were
 made for compliance)
 I attest to the accuracy of data. All measurements reported herein were performed by me or were made
 under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility
 for the completeness of these measurements and vouch for the qualificationsof all persons taking them.
 HCT certifies that no party to application has been denial the FCC benefits pursuant to Section 5301 of the
 Anti—Drug Abuse Act of 1988, 21 U.S.C 862




 Tested By                                              Reviewed By




 Wook Yi                                                Jin—Pyo     Hong
 Test Engineer                                          Technical Manager
 EMC Team                                               EMC Team
 Certification Division                                 Certification Division

This report only responds to the tested sample and may not be reproduced, except in full, without written approval of
the HCT Co., Ltd.


 F—TP22—03 (Rev.00)                         —            1/ 23—                     |            HCTCO.,LTD.


Model: ZNFX210APM                                                         Report No.: HCT-EM-1801-FC002-R1




REVISION HISTORY
 The revision history for this document is shown in table.


         Report No.               Issue Date                         Information About Changes

                                                           Initial Release
 HCT-EM-1801-FC002             January 03, 2018            Reissue of Report No. HCT-E-1711-F009
                                                           Changed the additional model name
 HCT-EM-1801-FC002-R1          January 05, 2018            Added Additional Model Name




F-TP22-03 (Rev.00)                                2 / 23                                 HCT CO.,LTD.


Model: ZNFX210APM                                                                                             Report No.: HCT-EM-1801-FC002-R1




                                                     TABLE OF CONTENTS

                                                                                                                                              PAGE

 1. GENERAL INFORMATION ........................................................................................................ 4
    1.1 Description of EUT .................................................................................................................. 4
    1.2 Related Submittal(s) / Grant(s) ................................................................................................ 5
    1.3 Test Facility .............................................................................................................................. 5
    1.4 Instrument Calibration.............................................................................................................. 5
    1.5 Tested System Details .............................................................................................................. 6
    1.6 Cable Description ..................................................................................................................... 6
    1.7 Noise Suppression Parts on Cable. (I/O Cable) ....................................................................... 6
 2. MEASUREMENT UNCERTAINTY ............................................................................................ 7
 3. DESCRIPTION OF TEST ............................................................................................................. 8
    3.1 Measurement of Conducted Emission ...................................................................................... 8
    3.2 Measurement of Radiated Emission ......................................................................................... 9
 4. PRELIMINARY TEST................................................................................................................ 11
    4.1 Conducted Emission Test ....................................................................................................... 11
    4.2 Radiated Emission Test .......................................................................................................... 11
 5. CONDUCTED AND RADIATED EMISSION TEST SUMMARY ........................................... 12
    5.1 Conducted Emission Test ....................................................................................................... 12
    5.2 Radiated Emission Test .......................................................................................................... 19
 6. LIST OF TEST EQUIPMENT .................................................................................................... 21
 7. CONCLUSION ............................................................................................................................ 22
 8. APPENDIX A. TEST SETUP PHOTOGRAPHS ....................................................................... 23




F-TP22-03 (Rev.00)                                                        3 / 23                                                  HCT CO.,LTD.


 Model: ZNFX210APM                                                 Report No.: HCT-EM-1801-FC002-R1




1. GENERAL INFORMATION
1.1 Description of EUT
 Its basic purpose is used for communications.

   FCC ID                      ZNFX210APM
   Model                       LM-X210APM
   Additional Model            LMX210APM, X210APM
   EUT Type                    GSM/WCDMA/LTE phone with Bluetooth and WLAN


                               824.20 MHz to 848.80 MHz (GSM 850)
                               1 850.20 MHz to 1 909.80 MHz (GSM 1 900)
                               1 852.4 MHz to 1 907.6 MHz (WCDMA B2)
                               1712.4 MHz to 1752.6 MHz (WCDMA B4)
                               826.40 MHz to 846.60 MHz (WCDMA B5)
   TX Frequency                1 850 MHz to 1 910 MHz (LTE B2)
                               1 710 MHz to 1 755 MHz (LTE B4)
                               824 MHz to 849 MHz (LTE B5)
                               699 MHz to 716 MHz (LTE B12)
                               2 402 MHz to 2 480 MHz (Bluetooth)
                               2 412 MHz to 2 462 MHz (WiFi 2.4 GHz)



                               869.20 MHz to 893.80 MHz (GSM 850)
                               1 930.20 MHz to 1 989.80 MHz (GSM 1 900)
                               1 932.4 MHz to 1 987.6 MHz (WCDMA B2)
                               2 112.4 MHz to 2 152.6 MHz (WCDMA B4)
                               871.40 MHz to 891.60 MHz (WCDMA B5)
   RX Frequency                1 930 MHz to 1 990 MHz (LTE B2)
                               2 110 MHz to 2 155 MHz (LTE B4)
                               869 MHz to 894 MHz (LTE B5)
                               729 MHz to 746 MHz (LTE B12)
                               2 402 MHz to 2 480 MHz (Bluetooth)
                               2 412 MHz to 2 462 MHz (WiFi 2.4 GHz)




F-TP22-03 (Rev.00)                               4 / 23                         HCT CO.,LTD.


 Model: ZNFX210APM                                                       Report No.: HCT-EM-1801-FC002-R1




1.2 Related Submittal(s) / Grant(s)

 Original submittal only.


1.3 Test Facility
 Test site is located at 74, SEOICHEON-RO, 578BEON-GIL, MAJANG-MYEON, ICHEON-SI,
 GYEONGGI-DO, SOUTH KOREA. Those measurement facilities are constructed in conformance with
 the requirements of ANSI C63.4-2014.


                     Measurement Facilities                                Registration Number
   Radiated Field strength measurement facility
   3 m Semi Anechoic chamber
                                                                                  90661
   Radiated Field strength measurement facility
   10 m Semi Anechoic chamber


1.4 Instrument Calibration
 The measuring equipment, which was utilized in performing the tests documented herein, has
 been calibrated in accordance with the manufacturers recommendations for utilizing calibration
 equipments, which is traceable to recognized national standards.
 Espectially, all antenna for measurement is calibrated in accordance with the requirements of C63.5
 (Version : 2006).




F-TP22-03 (Rev.00)                                5 / 23                               HCT CO.,LTD.


 Model: ZNFX210APM                                                          Report No.: HCT-EM-1801-FC002-R1




1.5 Tested System Details
  All equipment descriptions used in the tested system (including inserted cards) are:

         Device Type               Model Name                Serial Number                Manufacturer
   EUT                       LM-X210APM                             -                LG

   Data cable                EAD62377922                            -                KSD

   Earphone                  EAB64168751                            -                I-Sound

   Travel adaptor            MCS-02WDE                              -                DONGDO
                             SanDisk Extreme
   Micro SD card                                                    -                SanDisk
                             32 GB SD Card



1.6 Cable Description

                                                 Power Cord        I/O Cable Shielded
     Product Name               Port                                                          Length (m)
                                                Shielded (Y/N)           (Y/N)
                          Micro USB                     Y                    Y                (P)1.0
          EUT
                          Earphone                   N/A                     Y                (D)1.2

* The marked "(D)" means the data cable and "(P)" means the power cable.


1.7 Noise Suppression Parts on Cable. (I/O Cable)
                                              Ferrite Bead                       Metal Hood
     Product Name               Port                             Location                        Location
                                                 (Y/N)                             (Y/N)
                          Micro USB                 N              N/A               Y         Both End
          EUT
                          Earphone                  N              N/A               Y         EUT End




 F-TP22-03 (Rev.00)                                6 / 23                                 HCT CO.,LTD.


Model: ZNFX210APM                                                     Report No.: HCT-EM-1801-FC002-R1




2. MEASUREMENT UNCERTAINTY

 The measurement uncertainties shown below were calculated in accordance with the requirements
 of ANSI C63.4-2014.
 All measurement uncertainty values are shown with a coverage factor of k = 2 to indicate a 95 %
 level of confidence. The measurement data shown herein meets or exceeds the UCISPR measurement
 uncertainty values specified in CISPR 16-4-2 and, thus, can be compared directly to specified limits to
 determine compliance.


                     Parameter                                  Expanded Uncertainty (dB)

   Conducted Emission (0.15 MHz to 30 MHz)                            1.82 dB (k = 2)

   Radiated Emissions (30 MHz to 1 GHz)                               5.20 dB (k = 2)

   Radiated Emissions (1 GHz to 18 GHz)                               5.24 dB (k = 2)

   Radiated Emissions (18 GHz to 40 GHz)                              5.40 dB (k = 2)




F-TP22-03 (Rev.00)                              7 / 23                              HCT CO.,LTD.


Model: ZNFX210APM                                                    Report No.: HCT-EM-1801-FC002-R1




3. DESCRIPTION OF TEST

3.1 Measurement of Conducted Emission

 The test procedure was in accordance with ANSI C63.4-2014

 a. The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being
    connected to the power mains through a line impedance stabilization network (LISN).
    If the EUT is connected to the PC through USB, the AC power-line adapter of the PC is directly
    connected to a line impedance stabilization network (LISN).
    Other support units were connected to the power mains through another LISN. The two LISNs provide
    50 Ohm/ 50uH of coupling impedance for the measuring instrument.
 b. Both conducted lines are measured in Quasi-Peak and Average mode, including the worst-case
    data points for each tested configuration.
 c. The frequency range from 150 kHz to 30 MHz was searched.



                                 [ Conducted Emission Limit ]


         Frequency            Resolution Bandwidth           Quasi-Peak              Average
           (MHz)                      (kHz)                   (dBμV)                 (dBμV)

     0.15 to 0.5                        9                    66 to 56*              56 to 46*

     0.5 to 5                           9                       56                     46

     5 to 30                            9                       60                     50

 *Decreases with the logarithm of the frequency.




F-TP22-03 (Rev.00)                             8 / 23                             HCT CO.,LTD.


Model: ZNFX210APM                                                       Report No.: HCT-EM-1801-FC002-R1




3.2 Measurement of Radiated Emission

 The test procedure was in accordance with ANSI C63.4-2014

 a. The EUT was placed on the top of a turn table 0.8 meters above the ground at a semi anechoic chamber.
    The table was rotated 360 degrees to determine the position of the highest radiation.
 b. The EUT was set 3 m away from the interference-receiving antenna, which was mounted on the top of a
    variable-height antenna tower.
 c. The antenna height is varied from 1 m to 4 m above the ground to determine the maximum value of the
    field strength. Both horizontal and vertical polarizations of the antenna are set to make the
    measurement.
 d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to
    heights from 1 m to 4 m and the turn table was turned from 0 degrees to 360 degrees to find the
    maximum reading.
 e. The test-receiver system was set to Quasi-Peak detect function and specified bandwidth with maximum
    hold mode when the test frequency is below 1 GHz.
 f. The test-receiver system was set to Peak and Average detects function and specified bandwidth with
    maximum hold mode when the test frequency is above 1 GHz.
 g. Place the measurement antenna away from each area of the EUT determined to be a source of emissions
    at the specified measurement distance, while keeping the measurement antenna aimed at the source of
    emissions at each frequency of significant emissions, with polarization oriented for maximum response.
    (1 GHz to 40 GHz)



                                    [ Radiated Emission Limits ]


        Frequency             Antenna Distance            Field Strength             Quasi-Peak
          (MHz)                     (m)                      (μV/m)                  (dBμV/m)

        30 to 88                      3                        100                       40.0

        88 to 216                     3                        150                       43.5

        216 to 960                    3                        200                       46.0

        Above 960                     3                        500                       54.0

        Frequency             Antenna Distance                Peak                     Average
          (MHz)                     (m)                     (dBμV/m)                  (dBμV/m)

       Above 1 000                    3                         74                        54




F-TP22-03 (Rev.00)                               9 / 23                              HCT CO.,LTD.


 Model: ZNFX210APM                                                         Report No.: HCT-EM-1801-FC002-R1




3.2.1 Frequency Range of Radiated Measurements
 An unintentional radiator, including a digital device, the spectrum shall be investigated from the lowest
 radio frequency signal generated or used in the device, without going below the lowest frequency for
 which a Radiated Emission limit is specified, up to the frequency shown in the following table

    Highest frequency generated or used in the device
                                                             Upper frequency of measurement range
        or on which the device operates or tunes
                                                                            (MHz)
                        (MHz)

                Below 1.705                                       30

                1.705 to 108                                      1 000

                108 to 500                                        2 000

                500 to 1 000                                      5 000

                                                                  5th harmonic of the highest frequency
                Above 1 000
                                                                  or 40 GHz, whichever is lower




3.3 Configuration of Tested System



                                                        Travel
                                      EUT               Adaptor




                                            Earphone



                                                                                    Non-Conductive Table
                                                                                      Power Line: 120 VAC




F-TP22-03 (Rev.00)                              10 / 23                                 HCT CO.,LTD.


 Model: ZNFX210APM                                                         Report No.: HCT-EM-1801-FC002-R1




4. PRELIMINARY TEST

4.1 Conducted Emission Test
During preliminary tests, the following operating mode was investigated:


    Operation Mode:        Camera (Front) & MP3 mode
    Operation Mod          Camera (Rear) & FM Radio mode
    Operation Mode:        Idle mode
                        NOTE. The worst-case emissions are reported.



4.2 Radiated Emission Test

During preliminary tests, the following operating mode was investigated:


    Operation Mode:        Camera (Front) & MP3 mode
    Operation Mod          Camera (Rear) & FM Radio mode
    Operation Mode:        Idle mode
                        NOTE. The worst-case emissions are reported.




 F-TP22-03 (Rev.00)                               11 / 23                               HCT CO.,LTD.


 Model: ZNFX210APM                                                  Report No.: HCT-EM-1801-FC002-R1




5. CONDUCTED AND RADIATED EMISSION TEST SUMMARY

5.1 Conducted Emission Test
The test results of conducted emission at mains ports provide the following information:


     Rule Part / Standard             FCC PART 15 Subpart B Class B

     Detector                         Quasi-Peak, CISPR-Average

     Bandwidth                        9 kHz (6 dB)

     Worst Case of Operation Mode     Camera (Front) & MP3 mode

     Kind of Test Site                EMI Shielded Room

     Temperature                      22.0 / 22.0 °C

     Relative Humidity                47.0 / 46.8 %

     Test Date                        November 15 / November 17,    2017




    ※ Calculation Formula:

        1. Conductor L1 = Hot, Conductor N = Neutral
        2. Corr. = LISN Factor + Cable Loss
        3. QuasiPeak or CAverage= Receiver Reading + Corr.
        4. Margin = Limit – QuasiPeak or CAverage




 F-TP22-03 (Rev.00)                           12 / 23                            HCT CO.,LTD.


 Model: ZNFX210APM                                                                             Report No.: HCT-EM-1801-FC002-R1




Figure 1: Conducted Emission (0.15 to 30) MHz, Line (L1)



                                                        FCC CLASS B_Exten Cable


                          90


                          80


                          70


                          60


                          50
           Level in dBμ




                          40


                          30


                          20


                          10


                           0


                          -10
                            150k     300   400 500   800 1M               2M   3M   4M 5M 6     8 10M        20M   30M
                                                                 Frequency in Hz

                    FCC CLASS B_QP                   FCC CLASS B_ AV                  Preview Result 1-PK+
                    Preview Result 2-AVG             Final Result 1-QPK               Final Result 2-CAV




F-TP22-03 (Rev.00)                                                13 / 23                                    HCT CO.,LTD.


 Model: ZNFX210APM                                              Report No.: HCT-EM-1801-FC002-R1




QuasiPeak Final Result, Line (L1)



      Frequency      QuasiPeak   Bandwidth              Corr.          Margin         Limit
                                                 Line
        (MHz)         (dBuV)       (kHz)                (dB)            (dB)         (dBuV)


      0.152000         47.2        9.000          L1     9.7             18.6         65.9

      0.172000         34.7        9.000          L1     9.7             30.2         64.9

      0.190000         42.5        9.000          L1     9.7             21.5         64.0

      0.204000         27.8        9.000          L1     9.7             35.7         63.4

      0.380000         39.3        9.000          L1     9.7             18.9         58.3

      0.384000         39.5        9.000          L1     9.7             18.7         58.2

      3.102000         33.2        9.000          L1     9.9             22.8         56.0

      3.110000         32.4        9.000          L1     9.9             23.6         56.0

      3.168000         33.8        9.000          L1     9.9             22.2         56.0

      3.360000         35.0        9.000          L1     9.9             21.0         56.0

      3.402000         34.0        9.000          L1     9.9             22.0         56.0

      3.634000         32.2        9.000          L1    10.0             23.8         56.0

     11.256000         32.4        9.000          L1    10.4             27.6         60.0

     11.380000         32.2        9.000          L1    10.4             27.8         60.0

     11.852000         32.8        9.000          L1    10.4             27.2         60.0

     12.082000         32.5        9.000          L1    10.4             27.5         60.0

     12.166000         32.3        9.000          L1    10.4             27.7         60.0

     12.484000         32.4        9.000          L1    10.4             27.6         60.0




F-TP22-03 (Rev.00)                           14 / 23                            HCT CO.,LTD.


 Model: ZNFX210APM                                             Report No.: HCT-EM-1801-FC002-R1




CAverage Final Result, Line (L1)



      Frequency      CAverage   Bandwidth              Corr.          Margin         Limit
                                                Line
        (MHz)         (dBuV)      (kHz)                (dB)            (dB)         (dBuV)


      0.152000         35.6       9.000          L1     9.7             20.2         55.9

      0.172000         11.3       9.000          L1     9.7             43.6         54.9

      0.192000         29.8       9.000          L1     9.7             24.1         53.9

      0.204000         9.3        9.000          L1     9.7             44.2         53.4

      0.230000         25.5       9.000          L1     9.7             26.9         52.4

      0.382000         33.4       9.000          L1     9.7             14.8         48.2

      3.102000         24.0       9.000          L1     9.9             22.0         46.0

      3.110000         23.2       9.000          L1     9.9             22.8         46.0

      3.168000         22.0       9.000          L1     9.9             24.0         46.0

      3.360000         23.8       9.000          L1     9.9             22.2         46.0

      3.402000         24.0       9.000          L1     9.9             22.0         46.0

      3.634000         24.2       9.000          L1    10.0             21.8         46.0

     11.424000         22.5       9.000          L1    10.4             27.5         50.0

     11.680000         22.8       9.000          L1    10.4             27.2         50.0

     11.698000         22.5       9.000          L1    10.4             27.5         50.0

     12.082000         22.7       9.000          L1    10.4             27.3         50.0

     12.484000         22.9       9.000          L1    10.4             27.1         50.0

     13.266000         22.1       9.000          L1    10.5             27.9         50.0




F-TP22-03 (Rev.00)                          15 / 23                            HCT CO.,LTD.


 Model: ZNFX210APM                                                                             Report No.: HCT-EM-1801-FC002-R1




Figure 2: Conducted Emission (0.15 to 30) MHz, Line (N)


                                                        FCC CLASS B_Exten Cable


                          90


                          80


                          70


                          60


                          50
           Level in dBμ




                          40


                          30


                          20


                          10


                           0


                          -10
                            150k     300   400 500   800 1M               2M   3M   4M 5M 6     8 10M        20M   30M
                                                                 Frequency in Hz

                    FCC CLASS B_QP                   FCC CLASS B_ AV                  Preview Result 1-PK+
                    Preview Result 2-AVG             Final Result 1-QPK               Final Result 2-CAV




F-TP22-03 (Rev.00)                                                16 / 23                                    HCT CO.,LTD.


 Model: ZNFX210APM                                              Report No.: HCT-EM-1801-FC002-R1




QuasiPeak Final Result, Line (N)



      Frequency      QuasiPeak   Bandwidth              Corr.          Margin         Limit
                                                 Line
        (MHz)         (dBμV)       (kHz)                (dB)            (dB)         (dBμV)


      0.152000         47.1        9.000          N      9.7             18.8         65.9

      0.166000         34.9        9.000          N      9.7             30.2         65.2

      0.172000         35.4        9.000          N      9.7             29.5         64.9

      0.180000         35.7        9.000          N      9.7             28.8         64.5

      0.188000         41.9        9.000          N      9.7             22.2         64.1

      0.192000         40.8        9.000          N      9.7             23.2         63.9

      0.380000         40.9        9.000          N      9.7             17.4         58.3

      1.102000         31.2        9.000          N      9.8             24.8         56.0

      3.282000         30.4        9.000          N      9.9             25.6         56.0

      3.300000         32.1        9.000          N      9.9             23.9         56.0

      3.318000         30.5        9.000          N      9.9             25.5         56.0

      3.526000         32.4        9.000          N      9.9             23.6         56.0

     11.586000         31.5        9.000          N     10.4             28.5         60.0

     12.016000         31.6        9.000          N     10.4             28.4         60.0

     12.058000         31.3        9.000          N     10.4             28.7         60.0

     12.268000         31.4        9.000          N     10.4             28.6         60.0

     12.280000         31.6        9.000          N     10.4             28.4         60.0

     14.104000         30.1        9.000          N     10.5             29.9         60.0




F-TP22-03 (Rev.00)                           17 / 23                            HCT CO.,LTD.


 Model: ZNFX210APM                                             Report No.: HCT-EM-1801-FC002-R1




CAverage Final Result, Line (N)



      Frequency      CAverage   Bandwidth              Corr.          Margin         Limit
                                                Line
        (MHz)         (dBμV)      (kHz)                (dB)            (dB)         (dBμV)


      0.152000         33.9       9.000          N      9.7             22.0         55.9

      0.166000         14.5       9.000          N      9.7             40.6         55.2

      0.172000         13.7       9.000          N      9.7             41.1         54.9

      0.188000         28.4       9.000          N      9.7             25.8         54.1

      0.192000         27.6       9.000          N      9.7             26.3         53.9

      0.378000         32.1       9.000          N      9.7             16.2         48.3

      1.060000         24.4       9.000          N      9.8             21.6         46.0

      1.290000         22.5       9.000          N      9.8             23.5         46.0

      3.526000         21.7       9.000          N      9.9             24.3         46.0

      3.566000         19.9       9.000          N      9.9             26.1         46.0

      3.620000         19.2       9.000          N      9.9             26.8         46.0

      3.752000         20.4       9.000          N      9.9             25.6         46.0

     11.586000         20.0       9.000          N     10.4             30.0         50.0

     12.016000         20.0       9.000          N     10.4             30.0         50.0

     12.268000         20.1       9.000          N     10.4             29.9         50.0

     12.280000         20.1       9.000          N     10.4             29.9         50.0

     12.454000         20.2       9.000          N     10.4             29.8         50.0

     14.104000         19.7       9.000          N     10.5             30.3         50.0




F-TP22-03 (Rev.00)                          18 / 23                            HCT CO.,LTD.


 Model: ZNFX210APM                                                    Report No.: HCT-EM-1801-FC002-R1




5.2 Radiated Emission Test

The test results of radiated emission provide the following information:


    -For Measurement Below 1 GHz

      Rule Part / Standard                   FCC PART 15 Subpart B Class B

      Detector                               Quasi-Peak

      Bandwidth                              120 kHz (6 dB)

      Worst Case of Operation Mode           Camera (Front) & MP3 mode t

      Kind of Test Site                      3 m semi anechoic chamber

      Temperature                            22.6 / 23.3 °C

      Relative Humidity                      50.1 / 49.8 %

      Test Date                              November 06 / November 08, 2017



                                   Antenna
      Frequency       Quasi Peak               POL.       Azimuth     Corr.     Margin       Limit
                                    Height
        (MHz)         (dBμV/m)                 (H/V)       (deg)      (dB)       (dB)      (dBμV/m)
                                     (cm)

      40.952800           23.5      150.0       V             105.0   22.8       16.5        40.0

      50.600000           22.4      100.0       V             48.0    23.4       17.6        40.0

      59.876000           20.8      150.0       V             277.0   22.8       19.2        40.0

      95.497600           17.4      100.0       V             169.0   18.2       26.1        43.5

     191.176000           27.3      100.0       V             34.0    21.0       16.2        43.5

     254.900800           29.6      100.0       V             168.0   22.4       16.4        46.0



  ※ Calculation Formula:
        1. POL. H: Horizontal, POL. V: Vertical
        2. Quasi Peak = Reading (Receiver Reading) + Corr.
        3. Corr. (Correction Factor) = Antenna Factor + Cable Loss
        4. Margin = Limit – Quasi Peak




 F-TP22-03 (Rev.00)                             19 / 23                            HCT CO.,LTD.


Model: ZNFX210APM                                                        Report No.: HCT-EM-1801-FC002-R1




   -For Measurement Above 1 GHz
    Rule Part / Standard                   FCC PART 15 Subpart B Class B
                                           Peak mode: Peak (RBW: 1 MHz, VBW: 3 MHz)
    Detector
                                           CISPR-Average mode: Peak (RBW: 1 MHz, VBW: 10 Hz)
    Highest Operating Frequency            2 480 MHz
    Upper Frequency                        1 GHz to 12.4 GHz
    Worst Case of Operation Mode           Camera (Front) & MP3 mode t
    Kind of Test Site                      3 m semi anechoic chamber
    Temperature                            21.3 / 21.5 / 21.8 °C
    Relative Humidity                      47.5 / 47.2 / 47.0 %
    Test Date                              November 14 / November 15 / November 16, 2017


                                  Antenna
     Frequency         Peak                       POL.       Azimuth     Corr.     Margin       Limit
                                   Height
       (MHz)         (dBμV/m)                     (H/V)       (deg)      (dB)       (dB)      (dBμV/m)
                                    (cm)
   1202.275000          34.2       334.3            V         228.0      -13.5      39.8        74.0
   1463.230000          34.1       215.7           H               0.0   -12.7      39.9        74.0
   2020.565000          34.7       248.6           H          173.0      -11.7      39.3        74.0
   2622.135000          35.9       360.4            V         124.0      -9.4       38.1        74.0
   4877.935000          39.6       139.5           H          160.0      -4.9       34.4        74.0
   5376.055000          43.0       99.7             V         193.0      -3.5       31.0        74.0


                                  Antenna
     Frequency       CAverage                     POL.       Azimuth     Corr.     Margin       Limit
                                   Height
       (MHz)         (dBμV/m)                     (H/V)       (deg)      (dB)       (dB)      (dBμV/m)
                                    (cm)
   1202.275000          20.7       334.3            V         228.0      -13.5      33.3        54.0
   1463.230000          21.0       215.7           H               0.0   -12.7      33.0        54.0
   2020.565000          21.4       248.6           H          173.0      -11.7      32.6        54.0
   2622.135000          23.3       360.4            V         124.0      -9.4       30.7        54.0
   4877.935000          27.0       139.5           H          160.0      -4.9       27.0        54.0
   5376.055000          32.5       99.7             V         193.0      -3.5       21.9        54.0



 ※ Calculation Formula:
       1. POL. H: Horizontal, POL. V: Vertical
       2. Peak or CAverage = Reading (Receiver Reading) + Corr.
       3. Corr. (Correction Factor) = Antenna Factor+ Cable Loss –Amplifier Gain
       4. Margin = Limit - Peak or CAverage




F-TP22-03 (Rev.00)                                 20 / 23                            HCT CO.,LTD.


Model: ZNFX210APM                                                          Report No.: HCT-EM-1801-FC002-R1




6. LIST OF TEST EQUIPMENT

                                                                                     Calibration
     Type                        Manufacturer      Model Name        Serial Number                     CAL Date
                                                                                     Cycle
Conducted Emission

     EMI Test Receiver           Rohde & Schwarz   ESCI              100584           1 year       06.20.2017
     EMI Test Receiver           Rohde & Schwarz   ESCI              100033           1 year       06.27.2017
     LISN                        Rohde & Schwarz   ESH3-Z5           100282           1 year       05.22.2017
     LISN                        Rohde & Schwarz   ENV216            100073           1 year       12.23.2016
     LISN                        Rohde & Schwarz   ENV216            100073           1 year       07.18.2017
     Software                    Rohde & Schwarz   EMC32 VER8.54.0   -                -            -

Radiated Emission

-For measurement below 1 GHz
     EMI Test Receiver           Rohde & Schwarz   ESU40             100524           1 year       08.16.2017
     Trilog Antenna              Schwarzbeck       VULB 9168         760              2 year       04.06.2017
     Antenna master              HD GmbH           MA240             240/520          N/A          -
     Antenna master controller   HD GmbH           HD 100            100/637          N/A          -
     Turn Table                  INNCO Systems     -                 -                N/A          -
     Turn Table controller       INNCO Systems     CO2000            -                N/A          -
     EMI Test Receiver           Rohde & Schwarz   ESU26             100241           1 year       08.16.2017
     Antenna master              INNCO Systems     MA4000-EP         MA4000/283       N/A          -
     Turn Table                  INNCO Systems     DT3000-3T         DT3000/69        N/A          -
     Software                    Rohde & Schwarz   EMC32 VER8.40.0   -                -            -
-For measurement above 1 GHz
     EMI Test Receiver           Rohde & Schwarz   ESU40             100524           1 year       08.16.2017
     Antenna master              HD GmbH           MA240             240/520          N/A          -
     Antenna master controller   HD GmbH           HD 100            100/637          N/A          -
     Antenna master              INNCO Systems     MA4000-XP-ET      48709515         N/A          -
                                                                     CO 3000/870/
     Antenna master controller INNCO Systems       CO 3000                            N/A          -
                                                                     35990515
     Turn Table                  INNCO Systems     -                 -                N/A          -
     Turn Table controller       INNCO Systems     CO2000            -                N/A          -
     Power Amplifier             CERNEX            CBLU5183530       24348            1 year       06.01.2017
     Power Amplifier             CERNEX            CBL18265035       21873            1 year       01.19.2017
     Power Amplifier             CERNEX            CBL26405040       19660            1 year       07.11.2017
     Horn Antenna                Schwarzbeck       BBHA 9120D        296              2 year       10.12.2016
     Power Amplifier             CERNEX            CBLU1183540       21691            1 year       06.28.2017
     Horn Antenna                Schwarzbeck       BBHA 9120D        1300             2 year       06.30.2017
     Horn Antenna                Schwarzbeck       BBHA 9170         BBHA9170124      2 year       04.25.2017
     EMI Test Receiver           Rohde & Schwarz   ESU26             100241           1 year       08.16.2017
     Turn Table                  INNCO Systems     DT3000-3T         DT3000/69        N/A          -
     Software                    Rohde & Schwarz   EMC32 VER8.40.0   -                -            -




F-TP22-03 (Rev.00)                                   21 / 23                             HCT CO.,LTD.


 Model: ZNFX210APM                                      Report No.: HCT-EM-1801-FC002-R1




7. CONCLUSION

The data collected shows that the EUT Type: GSM/WCDMA/LTE phone with Bluetooth and
WLAN, Model: LM-X210APM, FCC ID: ZNFX210APM complies with §15.107 and §15.109 of
the FCC rules.




F-TP22-03 (Rev.00)                    22 / 23                        HCT CO.,LTD.


Model: ZNFX210APM                                 Report No.: HCT-EM-1801-FC002-R1




8. APPENDIX A. TEST SETUP PHOTOGRAPHS

                     Please refer to Appendix A




F-TP22-03 (Rev.00)           23 / 23                           HCT CO.,LTD.



Document Created: 2018-01-12 16:49:49
Document Modified: 2018-01-12 16:49:49

© 2024 FCC.report