SAR Report

FCC ID: ZNFW200V

RF Exposure Info

Download: PDF
FCCID_2770793

                     SAR EVALUATION REPORT


                        FCC 47 CFR § 2.1093
                         IEEE Std 1528-2013

                               For
             LTE Watch + BLUETOOTH+WLAN b/g/n & NFC

                         FCC ID: ZNFW200V
Model Name: LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW


                   Report Number: 15I21799-S1V2
                       Issue Date: 9/30/2015

                           Prepared for
              LG ELECTRONICS MOBILECOMM USA, INC.
                      1000 SYLVAN AVENUE
            ENGLEWOOD CLIFFS, NEW JERSEY 07632, USA

                            Prepared by
                  UL VERIFICATION SERVICES INC.
                      47173 BENICIA STREET
                    FREMONT, CA 94538, U.S.A.
                        TEL: (510) 771-1000
                        FAX: (510) 661-0888




                      NVLAP LAB CODE 200065-0


Report No.: 15I21799-S1V2                                                                        Issue Date: 9/30/2015

Revision History
 Rev.    Date             Revisions                                                        Revised By
 V1      9/28/2015        Initial Issue                                                    --
 V2      9/30/2015        Report revised based on Reviewer’s comments:                     Kenneth Mak
                          1. Added Section 6.4.
                          2. Appendix A: Updated




                                                    Page 2 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                                                          Issue Date: 9/30/2015

                                                                  Table of Contents

1.          Attestation of Test Results ......................................................................................................... 5

2.          Test Specification, Methods and Procedures............................................................................ 6

3.          Facilities and Accreditation ........................................................................................................ 6

4.          SAR Measurement System & Test Equipment .......................................................................... 7
     4.1.      SAR Measurement System ........................................................................................................ 7
     4.2.      SAR Scan Procedures ............................................................................................................... 8
     4.3.      Test Equipment........................................................................................................................ 10

5.          Measurement Uncertainty ......................................................................................................... 11

6.          Device Under Test (DUT) Information ...................................................................................... 12
     6.1.      DUT Description ...................................................................................................................... 12
     6.2.      Wireless Technologies ............................................................................................................. 12
     6.3.      Nominal and Maximum Output Power from Tune-up Procedure .............................................. 13
     6.4.      Antenna Dimensions and Separation Distances ...................................................................... 13
     6.5.      General LTE SAR Test and Reporting Considerations............................................................. 14

7.          RF Exposure Conditions (Test Configurations) ...................................................................... 14

8.          Dielectric Property Measurements & System Check .............................................................. 15
     8.1.      Dielectric Property Measurements ........................................................................................... 15
     8.2.      System Check.......................................................................................................................... 17

9.          Conducted Output Power Measurements................................................................................ 19
     9.1.      LTE .......................................................................................................................................... 19
     9.2.      Wi-Fi 2.4GHz (DTS Band) ....................................................................................................... 21
     9.3.      Bluetooth ................................................................................................................................. 21

10.         Measured and Reported (Scaled) SAR Results ....................................................................... 22
     10.1.        LTE Band 13 (10MHz Bandwidth) ........................................................................................ 24
     10.2.        Wi-Fi (DTS Band) ................................................................................................................. 24
     10.3.        Standalone SAR Test Exclusion Considerations & Estimated SAR ...................................... 25

11.         SAR Measurement Variability ................................................................................................... 26

12.         Simultaneous Transmission SAR Analysis ............................................................................. 27
     12.1.        Sum of the SAR for WWAN & Wi-Fi & BT (Extremity) .......................................................... 27
     12.2.        Sum of the SAR for WWAN & Wi-Fi & BT (Next-to-Mouth) ................................................... 27

Appendixes .......................................................................................................................................... 28
     15I21799-S1V2 SAR_App A Photos & Ant. Locations (STC_180days) .............................................. 28
                                                    Page 3 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                                 Issue Date: 9/30/2015
  15I21799-S1V1 SAR_App B System Check Plots .............................................................................. 28
  15I21799-S1V1 SAR_App C Highest Test Plots ................................................................................. 28
  15I21799-S1V1 SAR_App D Tissue Ingredients................................................................................. 28
  15I21799-S1V1 SAR_App E Probe Cal. Certs ................................................................................... 28
  15I21799-S1V1 SAR_App F Dipole Cal. Certs ................................................................................... 28




                                                    Page 4 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                          Issue Date: 9/30/2015

1. Attestation of Test Results
Applicant Name                      LG ELECTRONICS MOBILECOMM USA, INC.
FCC ID                              ZNFW200V
Model Name                          LG-W200V, LGW200V, W200V, LG-W200VW, LGW200VW, W200VW
Applicable Standards                FCC 47 CFR § 2.1093
                                    Published RF exposure KDB procedures
                                    IEEE Std 1528-2013
                                                   SAR Limits (W/Kg)
                                    Peak spatial-average(1g of tissue)          Extremities (hands, wrists, ankles, etc.)
Exposure Category
                                                                                (10g of tissue)
General population /                                   1.6                                          4
Uncontrolled exposure
                                           The Highest Reported SAR (W/kg)
                                                                     Equipment Class
RF Exposure Conditions
                                        Licensed                 DTS                   U-NII              DSS (BT)
Extremity                                  1.414                 0.497
Next-to-Mouth                              0.273                 0.104
Simultaneous TX     Extremity                         1.911                                       N/A
                    Next-to-
                                                      0.377
                    Mouth
Date Tested                         9/18/2015 to 9/21/2015
Test Results                        Pass
 UL Verification Services Inc. tested the above equipment in accordance with the requirements set forth in the
 above standards. All indications of Pass/Fail in this report are opinions expressed by UL Verification Services Inc.
 based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into
 account and are published for informational purposes only. The test results show that the equipment tested is
 capable of demonstrating compliance with the requirements as documented in this report.
Note: The results documented in this report apply only to the tested sample, under the conditions and modes of
operation as described herein. This document may not be altered or revised in any way unless done so by UL
Verification Services Inc. and all revisions are duly noted in the revisions section. Any alteration of this document
not carried out by UL Verification Services Inc. will constitute fraud and shall nullify the document. This report must
not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any agency of
the Federal Government, or any agency of any government (NIST Handbook 150, Annex A). This report is written
to support regulatory compliance of the applicable standards stated above.
Approved & Released By:                                       Prepared By:




Bobby Bayani                                                  Henry Wong
Senior Engineer                                               Laboratory Technician
UL Verification Services Inc.                                 UL Verification Services Inc.




                                                    Page 5 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                        Issue Date: 9/30/2015

2. Test Specification, Methods and Procedures
The tests documented in this report were performed in accordance with FCC 47 CFR § 2.1093, IEEE STD 1528-
2013, the following FCC Published RF exposure KDB procedures:
   o 248227 D01 802.11 Wi-Fi SAR v02r01
   o 447498 D01 General RF Exposure Guidance v05r02
   o 447498 D03 Supplement C Cross-Reference v01
   o 690783 D01 SAR Listings on Grants v01r03
   o 865664 D01 SAR measurement 100 MHz to 6 GHz v01r04
   o 865664 D02 RF Exposure Reporting v01r01
   o 941225 D05 SAR for LTE Devices v02r03



3. Facilities and Accreditation
The test sites and measurement facilities used to collect data are located at

 47173 Benicia Street                             47266 Benicia Street
 SAR Lab A                                        SAR Lab 1
 SAR Lab B                                        SAR Lab 2
 SAR Lab C                                        SAR Lab 3
 SAR Lab D                                        SAR Lab 4
 SAR Lab E                                        SAR Lab 5
 SAR Lab F
 SAR Lab G
 SAR Lab H

UL Verification Services Inc. is accredited by NVLAP, Laboratory Code 200065-0.




                                                    Page 6 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                         Issue Date: 9/30/2015

4. SAR Measurement System & Test Equipment
4.1.    SAR Measurement System
The DASY5 system used for performing compliance tests consists of the following items:




   A standard high precision 6-axis robot with controller, teach pendant and software. An arm extension for
    accommodating the data acquisition electronics (DAE).
   An isotropic Field probe optimized and calibrated for the targeted measurement.
   A data acquisition electronics (DAE) which performs the signal amplification, signal multiplexing, AD-
    conversion, offset measurements, mechanical surface detection, collision detection, etc. The unit is battery
    powered with standard or rechargeable batteries. The signal is optically transmitted to the EOC.
   The Electro-optical converter (EOC) performs the conversion from optical to electrical signals for the digital
    communication to the DAE. To use optical surface detection, a special version of the EOC is required. The
    EOC signal is transmitted to the measurement server.
   The function of the measurement server is to perform the time critical tasks such as signal filtering, control of
    the robot operation and fast movement interrupts.
   The Light Beam used is for probe alignment. This improves the (absolute) accuracy of the probe positioning.
   A computer running WinXP or Win7 and the DASY5 software.
   Remote control and teach pendant as well as additional circuitry for robot safety such as warning lamps, etc.
   The phantom, the device holder and other accessories according to the targeted measurement.




                                                    Page 7 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                        Issue Date: 9/30/2015

4.2. SAR Scan Procedures
Step 1: Power Reference Measurement
The Power Reference Measurement and Power Drift Measurements are for monitoring the power drift of the device
under test in the batch process. The minimum distance of probe sensors to surface determines the closest
measurement point to phantom surface. The minimum distance of probe sensors to surface is 2.1 mm. This
distance cannot be smaller than the distance of sensor calibration points to probe tip as defined in the probe
properties.

Step 2: Area Scan
The Area Scan is used as a fast scan in two dimensions to find the area of high field values, before doing a fine
measurement around the hot spot. The sophisticated interpolation routines implemented in DASY software can find
the maximum locations even in relatively coarse grids. When an Area Scan has measured all reachable points, it
computes the field maximal found in the scanned area, within a range of the global maximum. The range (in dB) is
specified in the standards for compliance testing. For example, a 2 dB range is required in IEEE Standard 1528
and IEC 62209 standards, whereby 3 dB is a requirement when compliance is assessed in accordance with the
ARIB standard (Japan). If only one Zoom Scan follows the Area Scan, then only the absolute maximum will be
taken as reference. For cases where multiple maximums are detected, the number of Zoom Scans has to be
increased accordingly.
Area Scan Parameters extracted from KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz




                                                    Page 8 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                        Issue Date: 9/30/2015
Step 3: Zoom Scan
Zoom Scans are used to assess the peak spatial SAR values within a cubic averaging volume containing 1 g and
10 g of simulated tissue. The Zoom Scan measures points (refer to table below) within a cube whose base faces
are centered on the maxima found in a preceding area scan job within the same procedure. When the
measurement is done, the Zoom Scan evaluates the averaged SAR for 1 g and 10 g and displays these values
next to the job’s label.
Zoom Scan Parameters extracted from KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz




Step 4: Power drift measurement
The Power Drift Measurement measures the field at the same location as the most recent power reference
measurement within the same procedure, and with the same settings. The Power Drift Measurement gives the field
difference in dB from the reading conducted within the last Power Reference Measurement. This allows a user to
monitor the power drift of the device under test within a batch process. The measurement procedure is the same as
Step 1.

Step 5: Z-Scan (FCC only)
The Z Scan measures points along a vertical straight line. The line runs along the Z-axis of a one-dimensional grid.
In order to get a reasonable extrapolation the extrapolated distance should not be larger than the step size in Z-
direction.




                                                    Page 9 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                                   Issue Date: 9/30/2015

4.3. Test Equipment
The measuring equipment used to perform the tests documented in this report has been calibrated in accordance
with the manufacturers’ recommendations, and is traceable to recognized national standards.
Dielectric Property Measurements
Name of Equipment                            Manufacturer               Type/Model            Serial No.      Cal. Due Date
Network Analyzer                                 Agilent                 8753ES              MY40000980         4/17/2016
Dielectric Probe kit                            SPEAG                    DAK-3.5                1087            11/11/2015
Shorting block                                  SPEAG                  DAK-3.5 Short        SM DAK 200 BA          N/A
                                           Traceable Calibration
Thermometer                                    Control Co.
                                                                           4242               122529162         10/8/2015
System Check
Name of Equipment                             Manufacturer               Type/Model            Serial No.       Cal. Due Date
Synthesized Signal Generator                        HP                     8665B              3744A01084          5/8/2016
Power Meter                                       Agilent                 N1912A              MY55196004          7/1/2017
Power Sensor                                      Agilent                 E9323A              MY53070007          3/2/2016
Power Sensor                                      Agilent                 E9323A              MY53070005          4/29/2016
Amplifier                                         MITEQ            AMF-4D-00400600-50-30P      1795093              N/A
Directional coupler                            Werlatone                 C8060-102                2149              N/A
DC Power Supply                                 AMETEK                    XT 15-4             1319A02778            N/A
Synthesized Signal Generator                        HP                     8665B              3744A01155          3/18/2016
Power Meter                                         HP                      437B              3125U16345          6/15/2016
Power Meter                                         HP                      437B              3125U12345          7/31/2016
Power Sensor                                        HP                     8481A              2702A76223          9/3/2016
Power Sensor                                        HP                     8481A              1926A27048          8/3/2016
Amplifier                                         MITEQ            AMF-4D-00400600-50-30P       1795092             N/A
Directional coupler                            Werlatone                 C8060-102                2141              N/A
DC Power Supply                             BK PRECISION                    1611               215-02292            N/A
E-Field Probe (SAR Lab A)                        SPEAG                    EX3DV4                  3901            1/27/2016
E-Field Probe (SAR Lab B)                        SPEAG                    EX3DV4                  3751           11/14/2015
Data Acquisition Electronics (SAR Lab A)         SPEAG                     DAE4                   1357            2/20/2016
Data Acquisition Electronics (SAR Lab B)         SPEAG                     DAE4                   1360            3/12/2016
System Validation Dipole                         SPEAG                    D750V3                  1024            5/12/2016
System Validation Dipole                         SPEAG                    D2450V2                 748             2/20/2016
Other
Name of Equipment                            Manufacturer               Type/Model             Serial No.      Cal. Due Date
Power Sensor                                    Keysight                  N1921A              MY55200002          7/6/2016
Power Meter                                     Keysight                  N1911A              MY55196017          7/6/2016
Base Station Simulator                            R&S                    CMW500               137877-MS          8/10/2016




                                                   Page 10 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                        Issue Date: 9/30/2015

5. Measurement Uncertainty
Per KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz, when the highest measured 1-g SAR within a
frequency band is < 1.5 W/kg, the extensive SAR measurement uncertainty analysis described in IEEE Std 1528-
2013 is not required in SAR reports submitted for equipment approval.




                                                   Page 11 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                                                Issue Date: 9/30/2015

6. Device Under Test (DUT) Information
6.1.      DUT Description
 Intended Use                  This device should be restricted to wrist-worn and no other operation configuration should be used
 Device Dimension              Overall (Length x Width):54.1 mm x 44.7 mm
                               Overall Diagonal: 44 mm
                               Display Diagonal: 37 mm
 Back Cover                    The rechargeable battery is not user accessible.
 Battery Options               The rechargeable battery is not user accessible.
 Wireless Router (Hotspot)     Wi-Fi Hotspot mode permits the device to share its cellular data connection with other Wi-Fi-enabled devices.
                               ☐ Mobile Hotspot (Wi-Fi 2.4 GHz)
                               ☒ Not supported
 Wi-Fi Direct                  Wi-Fi Direct enabled devices transfer data directly between each other
                               ☐ Wi-Fi Direct (Wi-Fi 2.4 GHz)
                               ☒ Not supported

6.2.      Wireless Technologies
         Wireless                                                                                                     Duty Cycle used for SAR
                             Frequency bands                              Operating mode
       technologies                                                                                                           testing
                                                    QPSK
                                                    16QAM
 LTE                     FDD Band 13                ☒ Rel. 10 Does not support Carrier Aggregation (CA)              100% (FDD)
                                                    ☐ Rel. 10 Carrier Aggregation (1 Uplink and 2 Downlinks)
                                                    ☐ Rel. 11 Carrier Aggregation (2 Uplink and 2 Downlinks)
                                                    802.11b
 Wi-Fi                   2.4 GHz                    802.11g                                                          100%
                                                    802.11n (HT20)
 Bluetooth               2.4 GHz                    Version 4.1 LE                                                   N/A




                                                   Page 12 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                        Issue Date: 9/30/2015

6.3.     Nominal and Maximum Output Power from Tune-up Procedure
KDB 447498 sec.4.1.(3) at the maximum rated output power and within the tune-up tolerance range specified for
the product, but not more than 2 dB lower than the maximum tune-up tolerance limit

Upper limit (dB):   -1.5    ~     0.5   Max. RF Output Pow er (dBm)
                                                          Max. tune-up
RF Air interface           Mode         Target
                                                          tolerance limit
                           QPSK          23.2                  23.7
  LTE Band 13
                       16QAM             22.2                  22.7
Upper limit (dB):                 1.0   Max. RF Output Pow er (dBm)
                                                          Max. tune-up
RF Air interface           Mode         Target
                                                          tolerance limit
                       802.11b           16.5                  17.5
  WiFi 2.4 GHz         802.11g           12.5                  13.5
                    802.11n HT20         11.5                  12.5
             Bluetooth                    9.5                  10.5
            Bluetooth LE                  8.0                  9.0



6.4.     Antenna Dimensions and Separation Distances
Refer to separate filing document.




                                                   Page 13 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                                           Issue Date: 9/30/2015

6.5.     General LTE SAR Test and Reporting Considerations
 Item                                       Description
 Frequency range, Channel Bandwidth,                                             Frequency range: 777 - 787 MHz
 Numbers and Frequencies                     Band 13                                   Channel Bandwidth
                                                             20 MHz       15 MHz      10 MHz        5 MHz       3 MHz               1.4 MHz
                                                 Low                                               23205/
                                                                                                    779.5
                                                 Mid                                  23230/       23230/
                                                                                        782          782
                                                 High                                              23255/
                                                                                                    784.5
 LTE transmitter and antenna                LTE has one (1) TX/RX antenna and one (1) RX antenna
 implementation                             Refer to Appendix A for more details.
 Maximum power reduction (MPR)




                                            MPR Built-in by design
                                            A-MPR (additional MPR) was disabled during SAR testing
 Power reduction                            No
 Spectrum plots for RB configurations       A properly configured base station simulator was used for the SAR and power measurements;
                                            therefore, spectrum plots for each RB allocation and offset configuration are not included in the
                                            SAR report.



7. RF Exposure Conditions (Test Configurations)
A non-standard setup was used for SAR testing based on guidance from the FCC. The operational
description contains additional information.

     Wireless            RF Exposure          DUT-to-User                Test                Antenna-to-               SAR
                                                                                                                                      Note
   technologies           Conditions           Separation               Position            edge/surface             Required
                           Extremity
                                                        0                 Rear                  N/A                     Yes
        WWAN           (Hand/Wrist/Ankle)
                         Next to Mouth                  10                Front                 N/A                     Yes
                           Extremity
                                                        0                 Rear                  N/A                     Yes
        WLAN           (Hand/Wrist/Ankle)
                         Next to Mouth                  10                Front                 N/A                     Yes
The neck region of the SAM phantom was chosen for wrist-worn extremity SAR testing in accordance with KDB
447498 §6.2.




                                                   Page 14 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                         Issue Date: 9/30/2015


8. Dielectric Property Measurements & System Check
8.1.    Dielectric Property Measurements
The temperature of the tissue-equivalent medium used during measurement must also be within 18C to 25C and
within ± 2C of the temperature when the tissue parameters are characterized.
The dielectric parameters must be measured before the tissue-equivalent medium is used in a series of SAR
measurements. The parameters should be re-measured after each 3 – 4 days of use; or earlier if the dielectric
parameters can become out of tolerance; for example, when the parameters are marginal at the beginning of the
measurement series.
Tissue dielectric parameters were measured at the low, middle and high frequency of each operating frequency
range of the test device.

Tissue Dielectric Parameters
FCC KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz
                                                Head                                       Body
    Target Frequency (MHz)
                                       er                 s (S/m)                er                  s (S/m)
             150                      52.3                 0.76                 61.9                  0.80
             300                      45.3                 0.87                 58.2                  0.92
             450                      43.5                 0.87                 56.7                  0.94
             835                      41.5                 0.90                 55.2                  0.97
             900                      41.5                 0.97                 55.0                  1.05
             915                      41.5                 0.98                 55.0                  1.06
            1450                      40.5                 1.20                 54.0                  1.30
            1610                      40.3                 1.29                 53.8                  1.40
         1800 – 2000                  40.0                 1.40                 53.3                  1.52
            2450                      39.2                 1.80                 52.7                  1.95
            3000                      38.5                 2.40                 52.0                  2.73
            5000                      36.2                 4.45                 49.3                  5.07
            5100                      36.1                 4.55                 49.1                  5.18
            5200                      36.0                 4.66                 49.0                  5.30
            5300                      35.9                 4.76                 48.9                  5.42
            5400                      35.8                 4.86                 48.7                  5.53
            5500                      35.6                 4.96                 48.6                  5.65
            5600                      35.5                 5.07                 48.5                  5.77
            5700                      35.4                 5.17                 48.3                  5.88
            5800                      35.3                 5.27                 48.2                  6.00


IEEE Std 1528-2013
Refer to Table 3 within the IEEE Std 1528-2013




                                                   Page 15 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                                Issue Date: 9/30/2015
Dielectric Property Measurements Results:

SAR Lab A
     Date       Freq. (MHz)                  Liquid Parameters                       Measured   Target    Delta (%)   Limit ±(%)
                              e'   39.1300             Relative Permittivity (єr):    39.13     39.20       -0.18         5
                Head 2450
                              e"   13.7800                     Conductivity (σ):       1.88     1.80        4.29          5
                              e'   39.2600             Relative Permittivity (єr):    39.26     39.28       -0.05         5
   9/18/2015    Head 2410
                              e"   13.6900                     Conductivity (σ):       1.83     1.76        4.21          5
                              e'   39.0400             Relative Permittivity (єr):    39.04     39.17       -0.33         5
                Head 2475
                              e"   13.8300                     Conductivity (σ):       1.90     1.83        4.17          5
                              e'   51.8200             Relative Permittivity (єr):    51.82     52.70       -1.67         5
                Body 2450
                              e"   14.8900                     Conductivity (σ):       2.03     1.95        4.02          5
                              e'   51.9200             Relative Permittivity (єr):    51.92     52.76       -1.59         5
   9/18/2015    Body 2410
                              e"   14.8000                     Conductivity (σ):       1.98     1.91        3.97          5
                              e'   51.7500             Relative Permittivity (єr):    51.75     52.67       -1.74         5
                Body 2475
                              e"   14.9400                       Conductivity (σ):     2.06     1.99        3.57          5


SAR Lab B
     Date       Freq. (MHz)                  Liquid Parameters                       Measured   Target    Delta (%)   Limit ±(%)
                              e'   54.3100             Relative Permittivity (єr):    54.31     55.55       -2.23         5
                Body 750
                              e"   23.3000                     Conductivity (σ):       0.97     0.96        0.89          5
                              e'   54.8800             Relative Permittivity (єr):    54.88     55.74       -1.54         5
   9/18/2015    Body 700
                              e"   23.7800                     Conductivity (σ):       0.93     0.96        -3.51         5
                              e'   53.8900             Relative Permittivity (єr):    53.89     55.39       -2.71         5
                Body 790
                              e"   22.9700                     Conductivity (σ):       1.01     0.97        4.43          5
                              e'   54.9000             Relative Permittivity (єr):    54.90     55.55       -1.16         5
                Body 750
                              e"   23.2900                     Conductivity (σ):       0.97     0.96        0.85          5
                              e'   55.4600             Relative Permittivity (єr):    55.46     55.74       -0.50         5
   9/21/2015    Body 700
                              e"   23.7300                     Conductivity (σ):       0.92     0.96        -3.71         5
                              e'   54.5000             Relative Permittivity (єr):    54.50     55.39       -1.61         5
                Body 790
                              e"   22.9200                     Conductivity (σ):       1.01     0.97        4.21          5
                              e'   41.0600             Relative Permittivity (єr):    41.06     41.96       -2.15         5
                Head 750
                              e"   21.8300                     Conductivity (σ):       0.91     0.89        1.94          5
                              e'   41.7300             Relative Permittivity (єr):    41.73     42.22       -1.16         5
   9/21/2015    Head 700
                              e"   21.8400                     Conductivity (σ):       0.85     0.89        -4.40         5
                              e'   40.5300             Relative Permittivity (єr):    40.53     41.76       -2.94         5
                Head 790
                              e"   21.2000                       Conductivity (σ):     0.93     0.90        3.92          5




                                                   Page 16 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                         Issue Date: 9/30/2015

8.2.      System Check
SAR system verification is required to confirm measurement accuracy, according to the tissue dielectric media,
probe calibration points and other system operating parameters required for measuring the SAR of a test device.
The system verification must be performed for each frequency band and within the valid range of each probe
calibration point required for testing the device. The same SAR probe(s) and tissue-equivalent media combinations
used with each specific SAR system for system verification must be used for device testing. When multiple probe
calibration points are required to cover substantially large transmission bands, independent system verifications are
required for each probe calibration point. A system verification must be performed before each series of SAR
measurements using the same probe calibration point and tissue-equivalent medium. Additional system verification
should be considered according to the conditions of the tissue-equivalent medium and measured tissue dielectric
parameters, typically every three to four days when the liquid parameters are re-measured or sooner when
marginal liquid parameters are used at the beginning of a series of measurements.

System Performance Check Measurement Conditions:
     The measurements were performed in the flat section of the TWIN SAM or ELI phantom, shell thickness: 2.0
      ±0.2 mm (bottom plate) filled with Body or Head simulating liquid of the following parameters.
     The depth of tissue-equivalent liquid in a phantom must be ≥ 15.0 cm for SAR measurements ≤ 3 GHz and ≥
      10.0 cm for measurements > 3 GHz.
     The DASY system with an E-Field Probe was used for the measurements.
     The dipole was mounted on the small tripod so that the dipole feed point was positioned below the center
      marking of the flat phantom section and the dipole was oriented parallel to the body axis (the long side of the
      phantom). The standard measuring distance was 10 mm (above 1 GHz) and 15 mm (below 1 GHz) from dipole
      center to the simulating liquid surface.
     The coarse grid with a grid spacing of 15 mm was aligned with the dipole.
      For 5 GHz band - The coarse grid with a grid spacing of 10 mm was aligned with the dipole.
     Special 7x7x7 (below 3 GHz) and/or 8x8x7 (above 3 GHz) fine cube was chosen for the cube.
     Distance between probe sensors and phantom surface was set to 3 mm.
      For 5 GHz band - Distance between probe sensors and phantom surface was set to 2.5 mm
     The dipole input power (forward power) was 100 mW.
     The results are normalized to 1 W input power.

Reference Target SAR Values
The reference SAR values can be obtained from the calibration certificate of system validation dipoles
                                                                               Target SAR Values (W/kg)
    System Dipole     Serial No.      Cal. Date      Freq. (MHz)
                                                                      1g/10g           Head               Body
                                                                        1g             8.10               8.41
      D750V3            1024          5/12/2015          750
                                                                        10g            5.33               5.60
                                                                        1g             52.7               50.3
      D2450V2            748          2/20/2015         2450
                                                                        10g            24.6               23.5




                                                   Page 17 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                            Issue Date: 9/30/2015
System Check Results
The 1-g and 10-g SAR measured with a reference dipole, using the required tissue-equivalent medium at the test
frequency, must be within 10% of the manufacturer calibrated dipole SAR target.

SAR Lab A
                  System Dipole                               Measured Results
                                            T.S.                                       Target       Delta    Plot
 Date Tested                                              Zoom Scan to   Normalize
                Type        Serial #       Liquid                                    (Ref. Value)   ±10 %    No.
                                                            100 mW        to 1 W
                                                    1g        5.08         50.8         50.3        0.99
  9/18/2015    D2450V2        748        Body                                                                 1,2
                                                    10g       2.32         23.2         23.5        -1.28
                                                    1g        5.31         53.1         52.7        0.76
  9/18/2015    D2450V2        748        Head
                                                    10g       2.42         24.2         24.6        -1.63


SAR Lab B
                  System Dipole                               Measured Results
                                            T.S.                                       Target       Delta    Plot
 Date Tested                                              Zoom Scan to   Normalize
                Type        Serial #       Liquid                                    (Ref. Value)   ±10 %    No.
                                                            100 mW        to 1 W
                                                    1g       0.815         8.15         8.41        -3.09
  9/18/2015      750         1024        Body
                                                    10g      0.541         5.41         5.60        -3.39
                                                    1g       0.852         8.52         8.41        1.31
  9/21/2015      750         1024        Body
                                                    10g      0.566         5.66         5.60        1.07
                                                    1g       0.780         7.80         8.10        -3.70
  9/21/2015      750         1024        Head                                                                 3,4
                                                    10g      0.513         5.13         5.33        -3.75




                                                   Page 18 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                        Issue Date: 9/30/2015

9. Conducted Output Power Measurements
9.1.    LTE
The following tests were conducted according to the test requirements outlined in section 6.2 of the 3GPP
TS36.101 specification.
UE Power Class: 3 (23 +/- 2dBm). The allowed Maximum Power Reduction (MPR) for the maximum output power
due to higher order modulation and transmit bandwidth configuration (resource blocks) is specified in Table 6.2.3-1
of the 3GPP TS36.101.




The allowed A-MPR values specified below in Table 6.2.4.-1 of 3GPP TS36.101 are in addition to the allowed MPR
requirements. All the measurements below were performed with A-MPR disabled, by using Network Signalling
Value of “NS_01”.




                                                   Page 19 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                             Issue Date: 9/30/2015
LTE Band 13 Measured Results
                  BW                     RB        RB      Target    Avg Pwr (dBm)
     Band                   Mode
                 (MHz)               Allocation   offset    MPR        782 MHz
                                         1          0        0           23.3
                                         1         25        0           23.4
                                         1         49        0           23.4
                            QPSK        25          0        1           22.5
                                        25         12        1           22.6
                                        25         25        1           22.6
     LTE                                50          0        1           22.6
                   10
    Band 13                              1          0        1           22.3
                                         1         25        1           22.3
                                         1         49        1           22.4
                           16QAM        25          0        2           21.5
                                        25         12        2           21.6
                                        25         25        2           21.6
                                        50          0        2           21.6
                  BW                     RB        RB      Target    Avg Pwr (dBm)
     Band                   Mode
                 (MHz)               Allocation   offset    MPR        782 MHz
                                         1          0        0           23.4
                                         1         12        0           23.4
                                         1         24        0           23.5
                            QPSK        12          0        1           22.5
                                        12          6        1           22.6
                                        12         11        1           22.6
     LTE                                25          0        1           22.6
                   5
    Band 13                              1          0        1           22.2
                                         1         12        1           22.2
                                         1         24        1           22.3
                           16QAM        12          0        2           21.5
                                        12          6        2           21.6
                                        12         11        2           21.6
                                        25          0        2           21.7


Note(s):
10/5 MHz Bandwidths does not support at least three non-overlapping channels in certain channel bandwidths. When a device
supports overlapping channel assignment in a channel bandwidth configuration, the middle channel of the group of overlapping
channels should be selected for testing per KDB 941225 D05 SAR for LTE Devices




                                                   Page 20 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                          Issue Date: 9/30/2015

9.2.         Wi-Fi 2.4GHz (DTS Band)
Measured Results
      Band                                        Freq.   Avg Pwr (dBm)    Max Output   SAR Test
                 Mode     Data Rate   Ch #
     (GHz)                                       (MHz)                    Power (dBm)   (Yes/No)
                                        1        2412         16.3
                802.11b    1 Mbps       6        2437         16.9           17.5         Yes
                                       11        2462         16.1
                                        1        2412
      2.4       802.11g    6 Mbps       6        2437                        13.5         No
                                       11        2462
                                                           Not Required
                                        1        2412
                802.11n
                          6.5 Mbps      6        2437                        12.5         No
                (HT20)
                                       11        2462


Note(s):
1.   Output Power and SAR is not required for 802.11g/n HT20 channels when the highest reported SAR for DSSS is adjusted
     by the ratio of OFDM to DSSS specified maximum output power and the adjusted SAR is ≤ 1.2 W/kg.



9.3.         Bluetooth
Maximum tune-up tolerance limit is 10.5 dBm from the rated nominal maximum output power. This power level
qualifies for exclusion of SAR testing.




                                                   Page 21 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                              Issue Date: 9/30/2015

10.     Measured and Reported (Scaled) SAR Results
SAR Test Reduction criteria are as follows:

KDB 447498 D01 General RF Exposure Guidance:
Testing of other required channels within the operating mode of a frequency band is not required when the reported 1-g or 10-g
SAR for the mid-band or highest output power channel is:
   ≤ 0.8 W/kg or 2.0 W/kg, for 1-g or 10-g respectively, when the transmission band is ≤ 100 MHz
   ≤ 0.6 W/kg or 1.5 W/kg, for 1-g or 10-g respectively, when the transmission band is between 100 MHz and 200 MHz
   ≤ 0.4 W/kg or 1.0 W/kg, for 1-g or 10-g respectively, when the transmission band is ≥ 200 MHz

KDB 941225 D05 SAR for LTE Devices:
SAR test reduction is applied using the following criteria:
  Start with the largest channel bandwidth and measure SAR for QPSK with 1 RB, and 50% RB allocation, using the RB
   offset and required test channel combination with the highest maximum output power among RB offsets at the upper edge,
   middle and lower edge of each required test channel.
  When the reported SAR is > 0.8/2 W/kg, 1-g and 10-g respectively, testing for other Channels is performed at the highest
   output power level for 1RB, and 50% RB configuration for that channel.
  Testing for 100% RB configuration is performed at the highest output power level for 100% RB configuration across the
   Low, Mid and High Channel when the highest reported SAR for 1 RB and 50% RB are > 0.8/2 W/kg, 1-g and 10-g
   respectively. Testing for the remaining required channels is not needed because the reported SAR for 100% RB Allocation
   < 1.45/3.625 W/kg, 1-g and 10-g respectively.
  Testing for 16-QAM modulation is not required because the reported SAR for QPSK is < 1.45/3.625 W/Kg, 1-g and 10-g
   respectively, and its output power is not more than 0.5 dB higher than that of QPSK.
  Testing for the other channel bandwidths is not required because the reported SAR for the highest channel bandwidth is <
   1.45/3.625 W/Kg, 1-g and 10-g respectively, and its output power is not more than 0.5 dB higher than that of the highest
   channel bandwidth.
  For LTE bands that do not support at least three non-overlapping channels in certain channel bandwidths, test the available
   non-overlapping channels instead. When a device supports overlapping channel assignment in a channel bandwidth
   configuration, the middle channel of the group of overlapping channels should be selected for testing; therefore, the
   requirement for H, M and L channels may not fully apply.




                                                   Page 22 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                                     Issue Date: 9/30/2015
KDB 248227 D01 SAR meas for 802.11:
SAR test reduction for 802.11 Wi-Fi transmission mode configurations are considered separately for DSSS and OFDM. An initial
test position is determined to reduce the number of tests required for certain exposure configurations with multiple test positions.
An initial test configuration is determined for each frequency band and aggregated band according to maximum output power,
channel bandwidth, wireless mode configurations and other operating parameters to streamline the measurement requirements.
For 2.4 GHz DSSS, either the initial test position or DSSS procedure is applied to reduce the number of SAR tests; these are
mutually exclusive. For OFDM, an initial test position is only applicable to next to the ear, UMPC mini-tablet and hotspot mode
configurations, which is tested using the initial test configuration to facilitate test reduction. For other exposure conditions with a
fixed test position, SAR test reduction is determined using only the initial test configuration.
     The multiple test positions require SAR measurements in head, hotspot mode or UMPC mini-tablet configurations may be
reduced according to the highest reported SAR determined using the initial test position(s) by applying the DSSS or OFDM SAR
measurement procedures in the required wireless mode test configuration(s). The initial test position(s) is measured using the
highest measured maximum output power channel in the required wireless mode test configuration(s). When the reported SAR
for the initial test position is:

        ≤ 0.4/1 W/kg, 1-g and 10-g respectively, further SAR measurement is not required for the other test positions in that
         exposure configuration and wireless mode combination within the frequency band or aggregated band. DSSS and
         OFDM configurations are considered separately according to the required SAR procedures.
        > 0.4/1 W/kg, 1-g and 10-g respectively, SAR is repeated using the same wireless mode test configuration tested in the
         initial test position to measure the subsequent next closet/smallest test separation distance and maximum coupling test
         position, on the highest maximum output power channel, until the reported SAR is ≤ 0.8/2 W/kg, 1-g and 10-g
         respectively, or all required test positions are tested.
         o For subsequent test positions with equivalent test separation distance or when exposure is dominated by coupling
               conditions, the position for maximum coupling condition should be tested.
         o When it is unclear, all equivalent conditions must be tested.
        For all positions/configurations tested using the initial test position and subsequent test positions, when the reported
         SAR is > 0.8/2 W/kg, 1-g and 10-g respectively, measure the SAR for these positions/configurations on the subsequent
         next highest measured output power channel(s) until the reported SAR is ≤ 1.2/3 W/kg, 1-g and 10-g respectively, or all
         required test channels are considered.
         o The additional power measurements required for this step should be limited to those necessary for identifying
               subsequent highest output power channels to apply the test reduction.
        When the specified maximum output power is the same for both UNII 1 and UNII 2A, begin SAR measurements in UNII
         2A with the channel with the highest measured output power. If the reported SAR for UNII 2A is ≤ 1.2/3 W/kg, 1-g and
         10-g respectively, SAR is not required for UNII 1; otherwise treat the remaining bands separately and test them
         independently for SAR.
        When the specified maximum output power is different between UNII 1 and UNII 2A, begin SAR with the band that has
         the higher specified maximum output. If the highest reported SAR for the band with the highest specified power is ≤
         1.2/3 W/kg, 1-g and 10-g respectively, testing for the band with the lower specified output power is not required;
         otherwise test the remaining bands independently for SAR.

     To determine the initial test position, Area Scans were performed to determine the position with the Maximum Value of SAR
(measured). The position that produced the highest Maximum Value of SAR is considered the worst case position; thus used as
the initial test position.




                                                   Page 23 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                                                                       Issue Date: 9/30/2015

10.1. LTE Band 13 (10MHz Bandwidth)
                                                                                                      Power (dBm)        1-g SAR (W/kg)         10-g SAR (W/kg)
RF Exposure               Dist.        Test                        Freq.       RB          RB                                                                            Plot
                 Mode                                     Ch #.                                    Tune-up
 Conditions              (mm)         Position                    (MHz)    Allocation     offest               Meas.     Meas.      Scaled      Meas.        Scaled      No.
                                                                                                     limit
                                                                                1          25       23.7        23.4                             1.320         1.414      1
  Extremity     QPSK       0           Neck           23230       782.0
                                                                               25          12        22.7       22.6                             0.943         0.965
                                                                                1          25        23.7       23.4     0.255      0.273                                 2
Next-to-Mouth QPSK         10           Flat          23230       782.0
                                                                               25          12        22.7       22.6     0.205      0.210


10.2. Wi-Fi (DTS Band)
                                                                                    Area Scan         Power (dBm)      1-g SAR (W/kg)        10-g SAR (W/kg)
Frequency             RF Exposure      Dist.                                Freq.                                                                                 Plot
              Mode                             Test Position      Ch #.             Max. SAR       Tune-up
  Band                 Conditions     (mm)                                 (MHz)                             Meas.     Meas.     Scaled      Meas.    Scaled      No.
                                                                                      (W/kg)         limit

                        Extremity       0         Neck             6       2437.0       0.948       17.5      16.9                           0.433       0.497     3
            802.11b
 2.4GHz
            1 Mbps
                      Next-to-Mouth    10          Flat            6       2437.0       0.120       17.5      16.9     0.091     0.104                             4




                                                   Page 24 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                                   Issue Date: 9/30/2015

10.3. Standalone SAR Test Exclusion Considerations & Estimated SAR
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)]·[√f(GHz)] ≤ 3.0, for 1-g SAR
and ≤ 7.5 for 10-g extremity SAR, where
         f(GHz) is the RF channel transmit frequency in GHz
         Power and distance are rounded to the nearest mW and mm before calculation
         The result is rounded to one decimal place for comparison
The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a
distance of 5 mm is applied to determine SAR test exclusion.

When the standalone SAR test exclusion is applied to an antenna that transmits simultaneously with other
antennas, the standalone SAR must be estimated according to following to determine simultaneous transmission
SAR test exclusion:
         (max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)]·[√f(GHz)/x] W/kg for test
          separation distances ≤ 50 mm;
                   where x = 7.5 for 1-g SAR, and x = 18.75 for 10-g SAR.
         0.4 W/kg for 1-g SAR and 1.0 W/kg for 10-g SAR, when the test separation distances is > 50 mm.


Extremity
  Max. tune-up tolerance limit         Min. test        Frequency         SAR test            Test           Estimated
                                      separation          (GHz)           exclusion       Configuration      10-g SAR
     (dBm)              (mW)        distance (mm)                          Result*                            (W/kg)
        10.5             11                 5              2.480              3.5              Neck             0.185

Conclusion:
*: The computed value is ≤ 7.5; therefore, Bluetooth qualifies for Standalone SAR test exclusion.

Next-to-Mouth
  Max. tune-up tolerance limit         Min. test        Frequency         SAR test            Test            Estimated
                                      separation          (GHz)           exclusion       Configuration       1-g SAR
     (dBm)              (mW)        distance (mm)                          Result*                             (W/kg)
        10.5             11                10              2.480              1.7               Flat            0.231

Conclusion:
*: The computed value is ≤ 3; therefore, Bluetooth qualifies for Standalone SAR test exclusion.




                                                   Page 25 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                                  Issue Date: 9/30/2015

11.        SAR Measurement Variability
In accordance with published RF Exposure KDB 865664 D01 SAR measurement 100 MHz to 6 GHz. These
additional measurements are repeated after the completion of all measurements requiring the same head or body
tissue-equivalent medium in a frequency band. The test device should be returned to ambient conditions (normal
room temperature) with the battery fully charged before it is re-mounted on the device holder for the repeated
measurement(s) to minimize any unexpected variations in the repeated results.

1) Repeated measurement is not required when the original highest measured SAR is <1.6 or 2 W/kg (1-g or 10-g
   respectively); steps 2) through 4) do not apply.
2) When the original highest measured SAR is ≥ 0.8 or 2 W/kg (1-g or 10-g respectively), repeat that
   measurement once.
3) Perform a second repeated measurement only if the ratio of largest to smallest SAR for the original and first
   repeated measurements is > 1.20 or 3 (1-g or 10-g respectively) or when the original or repeated measurement
   is ≥ 1.45 or 3.6 W/kg (~ 10% from the 1-g or 10-g respective SAR limit).
4) Perform a third repeated measurement only if the original, first, or second repeated measurement is ≥ 1.5 or
   3.75 W/kg (1-g or 10-g respectively) and the ratio of largest to smallest SAR for the original, first and second
   repeated measurements is > 1.20 or 3 (1-g or 10-g respectively).

Extremity
 Frequency                                                                 Repeated      Highest       Repeated     Largest to
    Band        Air Interface     RF Exposure Conditions   Test Position     SAR      Measured SAR   Measured SAR    Smallest
   (MHz)                                                                   (Yes/No)      (W/kg)         (W/kg)      SAR Ratio
                                        Extremity
    750         LTE Band 13                                   Neck           No           1.32           N/A           N/A
                                    (Hand/Wrist/Ankle)
                                        Extremity
    2400      Wi-Fi 802.11b/g/n                               Neck           No          0.406           N/A           N/A
                                    (Hand/Wrist/Ankle)

Note(s):
Second Repeated Measurement is not required since the ratio of the largest to smallest SAR for the original and first repeated
measurement is not > 3 W/kg.

Next-to-Mouth
 Frequency                                                                 Repeated      Highest       Repeated     Largest to
    Band        Air Interface     RF Exposure Conditions   Test Position     SAR      Measured SAR   Measured SAR    Smallest
   (MHz)                                                                   (Yes/No)      (W/kg)         (W/kg)      SAR Ratio
    750         LTE Band 13           Next to Mouth            Flat          No          0.255           N/A           N/A
    2400      Wi-Fi 802.11b/g/n       Next to Mouth            Flat          No          0.091           N/A           N/A

Note(s):
Second Repeated Measurement is not required since the ratio of the largest to smallest SAR for the original and first repeated
measurement is not > 1.20 W/kg.




                                                   Page 26 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                                  Issue Date: 9/30/2015

12.      Simultaneous Transmission SAR Analysis
Simultaneous Transmission Condition
  RF Exposure Condition        Item                     Capable Transmit Configurations
                                1          LTE            +           DTS
 Extremity & Next-to-Mouth
                                2          LTE            +           BT
Notes:
    1. VoIP is supported in LTE.



12.1. Sum of the SAR for WWAN & Wi-Fi & BT (Extremity)
                                                                          ① +②                            ① +③
 RF Expo sure         ①                ②               ③                WWA N + DTS                      WWA N + B T
  co nditio ns       WWA N            DTS              BT         ∑ 10-g SA R       SP LSR        ∑ 10-g SA R      SP LSR
                                                                    (mW/g)         (Yes/ No )       (mW/g)        (Yes/ No )

   Extremity           1.414          0.497           0.185           1.9 11           No             1.599           No


12.2. Sum of the SAR for WWAN & Wi-Fi & BT (Next-to-Mouth)
                                                                          ① +②                            ① +③
 RF Expo sure         ①                ②               ③                WWA N + DTS                      WWA N + B T
  co nditio ns       WWA N            DTS              BT          ∑ 1-g SA R       SP LSR        ∑ 1-g SA R       SP LSR
                                                                    (mW/g)         (Yes/ No )      (mW/g)         (Yes/ No )
    Next-to -
                      0.273           0.104           0.231          0 .3 7 7          No            0.504            No
    M o uth



Conclusion:
Simultaneous transmission SAR measurement (Volume Scan) is not required because the either sum of the 1-g SAR is <
1.6/4.0 W/kg, 1-g and 10-g respectively, or the SPLSR is ≤ 0.04 for 1-g and ≤ 0.10 for 10-g for all circumstances that require
SPLSR calculation.




                                                   Page 27 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21799-S1V2                                                                        Issue Date: 9/30/2015

Appendixes
Refer to separated files for the following appendixes.

15I21799-S1V2 SAR_App A Photos & Ant. Locations (STC_180days)

15I21799-S1V1 SAR_App B System Check Plots

15I21799-S1V1 SAR_App C Highest Test Plots

15I21799-S1V1 SAR_App D Tissue Ingredients

15I21799-S1V1 SAR_App E Probe Cal. Certs

15I21799-S1V1 SAR_App F Dipole Cal. Certs


                                                END OF REPORT




                                                   Page 28 of 28
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.



Document Created: 2015-09-30 11:56:28
Document Modified: 2015-09-30 11:56:28