Test Laboratory: UL Verification Services Inc. SAR Lab G                    Date/Time: 2/16/2015 11:03:24 AM

20150216_SystemPerformanceCheck-D2450V2 SN 706

Frequency: 2450 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C
Medium parameters used: f = 2450 MHz; σ = 2.021 S/m; ε r = 51.673; ρ = 1000 kg/m
                                                                                 3

DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/14/2014
- Probe: EX3DV4 - SN3990; ConvF(7.46, 7.46, 7.46); Calibrated: 4/15/2014;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI A; Type: QDOVA002AA; Serial: 1258

Body/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 5.50 W/kg

Body/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 63.595 V/m; Power Drift = -0.03 dB
Peak SAR (extrapolated) = 10.1 W/kg
SAR(1 g) = 4.85 W/kg; SAR(10 g) = 2.24 W/kg
Maximum value of SAR (measured) = 6.89 W/kg




                      0 dB = 6.89 W/kg = 8.38 dBW/kg




                                                                                                               Plot No. 1


Test Laboratory: UL Verification Services Inc. SAR Lab G    Date/Time: 2/16/2015 11:22:46 AM

20150216_SystemPerformanceCheck-D2450V2 SN 706
Frequency: 2450 MHz; Duty Cycle: 1:1

Body/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 6.73 W/kg




                                                                                           Plot No. 2