SAR Report revA

FCC ID: ZNFW150

RF Exposure Info

Download: PDF
FCCID_2573023

        SAR EVALUATION REPORT



           FCC 47 CFR § 2.1093
            IEEE Std 1528-2013

                 For
SMART WATCH WITH 2.4 DTS b/g/n + BT & BLE

            FCC ID: ZNFW150
   Model Name: LG-W150, LGW150, W150



       Report Number: 15I20081-S1A
           Issue Date: 4/1/2015

             Prepared for
LG ELECTRONICS MOBILECOMM U.S.A., INC.
          1000 SYLVAN AVE.
      ENGLEWOOD CLIFFS, NJ 07632

               Prepared by
     UL VERIFICATION SERVICES INC.
         47173 BENICIA STREET
       FREMONT, CA 94538, U.S.A.
           TEL: (510) 771-1000
           FAX: (510) 661-0888




          NVLAP LAB CODE 200065-0


Report No.: 15I20081-S1A                                                                          Issue Date: 4/1/2015

Revision History
 Rev.    Date             Revisions                                                        Revised By
 --      2/25/2015        Initial Issue                                                    --
         4/1/2015         Updated Extremity SAR to include high and low channels.          Yu Chen




                                                    Page 2 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20081-S1A                                                                                                          Issue Date: 4/1/2015

                                                                 Table of Contents

1.          Test Specification, Methods and Procedures............................................................................ 5

2.          Facilities and Accreditation ........................................................................................................ 5

3.          SAR Measurement System & Test Equipment .......................................................................... 6
     3.1.      SAR Measurement System ........................................................................................................ 6
     3.2.      SAR Scan Procedures ............................................................................................................... 7
     3.3.      Test Equipment.......................................................................................................................... 9

4.          Measurement Uncertainty ......................................................................................................... 10

5.          Device Under Test (DUT) Information ...................................................................................... 11
     5.1.      DUT Description ...................................................................................................................... 11
     5.2.      Wireless Technologies ............................................................................................................. 11
     5.3.      Nominal and Maximum Output Power...................................................................................... 11

6.          RF Exposure Conditions (Test Configurations) ...................................................................... 12

7.          Dielectric Property Measurements & System Check .............................................................. 13
     7.1.      Dielectric Property Measurements ........................................................................................... 13
     7.2.      System Check.......................................................................................................................... 15

8.          Conducted Output Power Measurements................................................................................ 17
     8.1.      Wi-Fi 2.4GHz (DTS Band) ....................................................................................................... 17
     8.2.      Bluetooth ................................................................................................................................. 17

9.          Measured and Reported (Scaled) SAR Results ....................................................................... 18
     9.1.      Wi-Fi (DTS Band) .................................................................................................................... 19
     9.2.      Bluetooth ................................................................................................................................. 19

10.         SAR Measurement Variability ................................................................................................... 20

11.         Simultaneous Transmission SAR Analysis ............................................................................. 21

Appendixes .......................................................................................................................................... 22
     A_15I20081v0 SAR Photos & Ant. Locations ..................................................................................... 22
     B_15I20081v0 SAR System Check Plots ........................................................................................... 22
     C_15I20081v1 SAR Highest Test Plots .............................................................................................. 22
     D_15I20081v0 SAR Tissue Ingredients .............................................................................................. 22
     E_15I20081v0 SAR Probe Cal. Certificates ........................................................................................ 22
     F_15I20081v0 SAR Dipole Cal. Certificates ....................................................................................... 22




                                                    Page 3 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20081-S1A                                                                           Issue Date: 4/1/2015
Attestation of Test Results
Applicant Name                      LG ELECTRONICS MOBILECOMM U.S.A., INC.
FCC ID                              ZNFW150
Model Name                          LG-W150, LGW150, W150
Applicable Standards                FCC 47 CFR § 2.1093
                                    Published RF exposure KDB procedures
                                    IEEE Std 1528-2013
SAR Limits (W/Kg)
                                    Peak spatial-average(1g of tissue)         Extremities (hands, wrists, ankles, etc.)
Exposure Category
                                                                               (10g of tissue)
General population /                1.6                                        4
Uncontrolled exposure
The Highest Reported SAR (W/kg)
                                                                    Equipment Class
RF Exposure Conditions
                                    Licensed             DTS                   U-NII                 DSS (BT)
Next to Mouth                       N/A                  0.150                 N/A                   N/A
Extremity                           N/A                  0.511                 N/A                   N/A
Date Tested                         2/16/2015 to 2/19/2015
Test Results                        Pass
 UL Verification Services Inc. tested the above equipment in accordance with the requirements set forth in the
 above standards. All indications of Pass/Fail in this report are opinions expressed by UL Verification Services Inc.
 based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into
 account and are published for informational purposes only. The test results show that the equipment tested is
 capable of demonstrating compliance with the requirements as documented in this report.
Note: The results documented in this report apply only to the tested sample, under the conditions and modes of
operation as described herein. This document may not be altered or revised in any way unless done so by UL
Verification Services Inc. and all revisions are duly noted in the revisions section. Any alteration of this document
not carried out by UL Verification Services Inc. will constitute fraud and shall nullify the document. This report must
not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any agency of
the Federal Government, or any agency of any government (NIST Handbook 150, Annex A). This report is written
to support regulatory compliance of the applicable standards stated above.
Approved & Released By:                                      Prepared By:




Bobby Bayani                                                 Yu Chen
Senior Engineer                                              Laboratory Technician
UL Verification Services Inc.                                UL Verification Services Inc.




                                                    Page 4 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20081-S1A                                                                          Issue Date: 4/1/2015

1. Test Specification, Methods and Procedures
The tests documented in this report were performed in accordance with FCC 47 CFR § 2.1093, IEEE STD 1528-
2013, the following FCC Published RF exposure KDB procedures:
   o 248227 D01 SAR meas for 802.11 v02
   o 447498 D01 General RF Exposure Guidance v05r02
   o 447498 D03 Supplement C Cross-Reference
   o 690783 D01 SAR Listings on Grants v01r03
   o 865664 D01 SAR measurement 100 MHz to 6 GHz v01r03
   o 865664 D02 RF Exposure Reporting v01r01

2. Facilities and Accreditation
The test sites and measurement facilities used to collect data are located at

 47173 Benicia Street                             47266 Benicia Street
 SAR Lab A                                        SAR Lab 1
 SAR Lab B                                        SAR Lab 2
 SAR Lab C                                        SAR Lab 3
 SAR Lab D                                        SAR Lab 4
 SAR Lab E                                        SAR Lab 5
 SAR Lab F
 SAR Lab G
 SAR Lab H

UL Verification Services Inc. is accredited by NVLAP, Laboratory Code 200065-0.




                                                    Page 5 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20081-S1A                                                                           Issue Date: 4/1/2015

3. SAR Measurement System & Test Equipment
3.1.    SAR Measurement System
The DASY5 system used for performing compliance tests consists of the following items:




   A standard high precision 6-axis robot with controller, teach pendant and software. An arm extension for
    accommodating the data acquisition electronics (DAE).
   An isotropic Field probe optimized and calibrated for the targeted measurement.
   A data acquisition electronics (DAE) which performs the signal amplification, signal multiplexing, AD-
    conversion, offset measurements, mechanical surface detection, collision detection, etc. The unit is battery
    powered with standard or rechargeable batteries. The signal is optically transmitted to the EOC.
   The Electro-optical converter (EOC) performs the conversion from optical to electrical signals for the digital
    communication to the DAE. To use optical surface detection, a special version of the EOC is required. The
    EOC signal is transmitted to the measurement server.
   The function of the measurement server is to perform the time critical tasks such as signal filtering, control of
    the robot operation and fast movement interrupts.
   The Light Beam used is for probe alignment. This improves the (absolute) accuracy of the probe positioning.
   A computer running WinXP or Win7 and the DASY5 software.
   Remote control and teach pendant as well as additional circuitry for robot safety such as warning lamps, etc.
   The phantom, the device holder and other accessories according to the targeted measurement.




                                                    Page 6 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20081-S1A                                                                          Issue Date: 4/1/2015

3.2. SAR Scan Procedures
Step 1: Power Reference Measurement
The Power Reference Measurement and Power Drift Measurements are for monitoring the power drift of the device
under test in the batch process. The minimum distance of probe sensors to surface determines the closest
measurement point to phantom surface. The minimum distance of probe sensors to surface is 2.1 mm. This
distance cannot be smaller than the distance of sensor calibration points to probe tip as defined in the probe
properties.

Step 2: Area Scan
The Area Scan is used as a fast scan in two dimensions to find the area of high field values, before doing a fine
measurement around the hot spot. The sophisticated interpolation routines implemented in DASY software can find
the maximum locations even in relatively coarse grids. When an Area Scan has measured all reachable points, it
computes the field maximal found in the scanned area, within a range of the global maximum. The range (in dB) is
specified in the standards for compliance testing. For example, a 2 dB range is required in IEEE Standard 1528
and IEC 62209 standards, whereby 3 dB is a requirement when compliance is assessed in accordance with the
ARIB standard (Japan). If only one Zoom Scan follows the Area Scan, then only the absolute maximum will be
taken as reference. For cases where multiple maximums are detected, the number of Zoom Scans has to be
increased accordingly.
Area Scan Parameters extracted from KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz




                                                    Page 7 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20081-S1A                                                                          Issue Date: 4/1/2015
Step 3: Zoom Scan
Zoom Scans are used to assess the peak spatial SAR values within a cubic averaging volume containing 1 g and
10 g of simulated tissue. The Zoom Scan measures points (refer to table below) within a cube whose base faces
are centered on the maxima found in a preceding area scan job within the same procedure. When the
measurement is done, the Zoom Scan evaluates the averaged SAR for 1 g and 10 g and displays these values
next to the job’s label.
Zoom Scan Parameters extracted from KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz




Step 4: Power drift measurement
The Power Drift Measurement measures the field at the same location as the most recent power reference
measurement within the same procedure, and with the same settings. The Power Drift Measurement gives the field
difference in dB from the reading conducted within the last Power Reference Measurement. This allows a user to
monitor the power drift of the device under test within a batch process. The measurement procedure is the same as
Step 1.

Step 5: Z-Scan (FCC only)
The Z Scan measures points along a vertical straight line. The line runs along the Z-axis of a one-dimensional grid.
In order to get a reasonable extrapolation the extrapolated distance should not be larger than the step size in Z-
direction.




                                                    Page 8 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20081-S1A                                                                                    Issue Date: 4/1/2015

3.3. Test Equipment
The measuring equipment used to perform the tests documented in this report has been calibrated in accordance
with the manufacturers’ recommendations, and is traceable to recognized national standards.
Dielectric Property Measurements
Name of Equipment                            Manufacturer                Type/Model           Serial No.       Cal. Due Date
Network Analyzer                                 Agilent                  8753ES             MY40001647         7/17/2015
Dielectronic Probe kit                          SPEAG                     DAK-3.5                1087           11/11/2015
Dielectronic Probe kit                          SPEAG                   DAK-3.5 Short       SM DAK 200 BA          N/A
                                           Traceable Calibration
Thermometer                                    Control Co.
                                                                            4242              122529162         10/8/2015


System Check
Name of Equipment                            Manufacturer                Type/Model           Serial No.       Cal. Due Date
Synthesized Signal Generator                       HP                      8665B             3744A01084         5/20/2015
Power Meter                                      Agilent                  N1912A             MY53040016          5/5/2015
Power Sensor                                     Agilent                  E9323A             MY53070005          5/1/2015
Power Sensor                                     Agilent                  E9323A             MY53070009         5/28/2015
Amplifier                                        MITEQ             AMF-4D-00400600-50-30P     1795093              N/A
Directional coupler                           Werlatone                  C8060-102               2149              N/A
DC Power Supply                                AMETEK                     XT 15-4            1319A02778            N/A
Synthesized Signal Generator                       HP                      8665B             3744A01155         3/12/2015
Power Meter                                        HP                       437B             3125U11364         8/27/2015
Power Meter                                        HP                       437B             3125U12345         8/15/2015
Power Sensor                                       HP                      8481A             1926A27048         8/15/2015
Power Sensor                                       HP                      8481A             2702A76223         9/17/2015
Amplifier                                        MITEQ             AMF-4D-00400600-50-30P      1795092             N/A
Directional coupler                           Werlatone                  C8060-102               2141              N/A
DC Power Supply                            BK PRECISION                     1611              215-02292            N/A
E-Field Probe (SAR Lab G)                       SPEAG                     EX3DV4                 3990           4/15/2015
Data Acquisition Electronics (SAR Lab G)        SPEAG                      DAE4                  1434           4/14/2015
System Validation Dipole                        SPEAG                     D2450V2                706            5/20/2015


Other
Name of Equipment                           Manufacturer                Type/Model            Serial No.      Cal. Due Date
Power Meter                                     Agilent                   N1921A            MY52200012          9/26/2015
Power Sensor                                    Agilent                   N1911A            MY53060009          5/5/2015




                                                    Page 9 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20081-S1A                                                                          Issue Date: 4/1/2015

4. Measurement Uncertainty
Per KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz, when the highest measured 1-g SAR within a
frequency band is < 1.5 W/kg, the extensive SAR measurement uncertainty analysis described in IEEE Std 1528-
2013 is not required in SAR reports submitted for equipment approval.




                                                   Page 10 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20081-S1A                                                                                               Issue Date: 4/1/2015

5. Device Under Test (DUT) Information
5.1.     DUT Description
 Device Dimension                       Overall (Length x Width): 56.5 mm x 45.4 mm (excluding strap)
                                        Overall Diagonal: 62.0 mm
                                        Display Diagonal: 35.0 mm
 Back Cover                             ☒ The rechargeable battery is not user accessible.
 Battery Options                        ☒ The rechargeable battery is not user accessible.
 Wi-Fi Direct                           Wi-Fi Direct enabled devices transfer data directly between each other
                                        ☒ Wi-Fi Direct (Wi-Fi 2.4 GHz)

5.2.     Wireless Technologies
 Wireless                 Frequency bands              Operating mode                                            Duty Cycle used for SAR
 technologies                                                                                                    testing
 Wi-Fi                    2.4 GHz                      802.11b                                                   100%
                                                       802.11g
                                                       802.11n (HT20)
 Bluetooth                2.4 GHz                      Version 1.2                                               N/A
                                                       Version 2.0 + EDR
                                                       Version 2.1 + EDR
                                                       Version 3.0 + HS
                                                       Version 4.0 LE

5.3.     Nominal and Maximum Output Power
KDB 447498 sec.4.1.(3) at the maximum rated output power and within the tune-up tolerance range specified for
the product, but not more than 2 dB lower than the maximum tune-up tolerance limit

Upper limit (dB):             ~   1.0              Max. RF Output Pow er (dBm)
                                                                         Max. tune-up
RF Air interface         Mode                      Target
                                                                         tolerance limit
                        802.11b                     17.0                      18.0
  WiFi 2.4 GHz          802.11g                     14.0                      15.0
                     802.11n HT20                   13.0                      14.0


Upper limit (dB):             ~   1.5              Max. RF Output Pow er (dBm)
                                                                         Max. tune-up
RF Air interface         Mode                      Target
                                                                         tolerance limit
         Bluetooth (GFSK)                            8.5                      10.0
          Bluetooth (DPSK)                           5.5                       7.0
         Bluetooth (8DPSK)                           5.5                       7.0
             Bluetooth (LE)                          7.5                       9.0




                                                   Page 11 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20081-S1A                                                                          Issue Date: 4/1/2015

6. RF Exposure Conditions (Test Configurations)
Refer to “SAR Photos and Ant locations” Appendix for the specific details of the antenna-to-antenna and
antenna-to-edge(s) distances.

     Wireless        RF Exposure        DUT-to-User        Test            Antenna-to-        SAR
                                                                                                          Note
   technologies       Conditions         Separation       Position        edge/surface      Required
                       Extremity
                                           0mm              Rear             N/A               Yes
      WLAN         (Hand/Wrist/Ankle)
                    Next to Mouth         10mm             Front             N/A               Yes




                                                   Page 12 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20081-S1A                                                                          Issue Date: 4/1/2015

7. Dielectric Property Measurements & System Check
7.1.    Dielectric Property Measurements
The temperature of the tissue-equivalent medium used during measurement must also be within 18C to 25C and
within ± 2C of the temperature when the tissue parameters are characterized.
The dielectric parameters must be measured before the tissue-equivalent medium is used in a series of SAR
measurements. The parameters should be re-measured after each 3 – 4 days of use; or earlier if the dielectric
parameters can become out of tolerance; for example, when the parameters are marginal at the beginning of the
measurement series.
Tissue dielectric parameters were measured at the low, middle and high frequency of each operating frequency
range of the test device.

Tissue Dielectric Parameters
FCC KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz
                                                Head                                       Body
    Target Frequency (MHz)
                                       er                 s (S/m)                er                 s (S/m)
             150                      52.3                 0.76                 61.9                 0.80
             300                      45.3                 0.87                 58.2                 0.92
             450                      43.5                 0.87                 56.7                 0.94
             835                      41.5                 0.90                 55.2                 0.97
             900                      41.5                 0.97                 55.0                 1.05
             915                      41.5                 0.98                 55.0                 1.06
            1450                      40.5                 1.20                 54.0                 1.30
            1610                      40.3                 1.29                 53.8                 1.40
         1800 – 2000                  40.0                 1.40                 53.3                 1.52
            2450                      39.2                 1.80                 52.7                 1.95
            3000                      38.5                 2.40                 52.0                 2.73
            5000                      36.2                 4.45                 49.3                 5.07
            5100                      36.1                 4.55                 49.1                 5.18
            5200                      36.0                 4.66                 49.0                 5.30
            5300                      35.9                 4.76                 48.9                 5.42
            5400                      35.8                 4.86                 48.7                 5.53
            5500                      35.6                 4.96                 48.6                 5.65
            5600                      35.5                 5.07                 48.5                 5.77
            5700                      35.4                 5.17                 48.3                 5.88
            5800                      35.3                 5.27                 48.2                 6.00


IEEE Std 1528-2013
Refer to Table 3 within the IEEE Std 1528-2013




                                                   Page 13 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20081-S1A                                                                                 Issue Date: 4/1/2015
Dielectric Property Measurements Results:

SAR Lab G
     Date       Freq. (MHz)                  Liquid Parameters                       Measured   Target   Delta (%)   Limit ±(%)
                              e'   40.5100             Relative Permittivity (єr):    40.51     39.20      3.34          5
                Head 2450
                              e"   13.7500                     Conductivity (σ):       1.87     1.80       4.06          5
                              e'   40.6600             Relative Permittivity (єr):    40.66     39.28      3.52          5
   2/16/2015    Head 2410
                              e"   13.6200                     Conductivity (σ):       1.83     1.76       3.67          5
                              e'   40.4100             Relative Permittivity (єr):    40.41     39.17      3.17          5
                Head 2475
                              e"   13.7700                     Conductivity (σ):       1.89     1.83       3.72          5
                              e'   51.6700             Relative Permittivity (єr):    51.67     52.70      -1.95         5
                Body 2450
                              e"   14.8300                     Conductivity (σ):       2.02     1.95       3.60          5
                              e'   51.8100             Relative Permittivity (єr):    51.81     52.76      -1.80         5
   2/16/2015    Body 2410
                              e"   14.6800                     Conductivity (σ):       1.97     1.91       3.13          5
                              e'   51.5500             Relative Permittivity (єr):    51.55     52.67      -2.12         5
                Body 2475
                              e"   14.9100                       Conductivity (σ):     2.05     1.99       3.36          5




                                                   Page 14 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20081-S1A                                                                          Issue Date: 4/1/2015

7.2.    System Check
SAR system verification is required to confirm measurement accuracy, according to the tissue dielectric media,
probe calibration points and other system operating parameters required for measuring the SAR of a test device.
The system verification must be performed for each frequency band and within the valid range of each probe
calibration point required for testing the device. The same SAR probe(s) and tissue-equivalent media combinations
used with each specific SAR system for system verification must be used for device testing. When multiple probe
calibration points are required to cover substantially large transmission bands, independent system verifications are
required for each probe calibration point. A system verification must be performed before each series of SAR
measurements using the same probe calibration point and tissue-equivalent medium. Additional system verification
should be considered according to the conditions of the tissue-equivalent medium and measured tissue dielectric
parameters, typically every three to four days when the liquid parameters are re-measured or sooner when
marginal liquid parameters are used at the beginning of a series of measurements.

System Performance Check Measurement Conditions:
   The measurements were performed in the flat section of the TWIN SAM or ELI phantom, shell thickness: 2.0
    ±0.2 mm (bottom plate) filled with Body or Head simulating liquid of the following parameters.
   The depth of tissue-equivalent liquid in a phantom must be ≥ 15.0 cm for SAR measurements ≤ 3 GHz and ≥
    10.0 cm for measurements > 3 GHz.
   The DASY system with an E-Field Probe was used for the measurements.
   The dipole was mounted on the small tripod so that the dipole feed point was positioned below the center
    marking of the flat phantom section and the dipole was oriented parallel to the body axis (the long side of the
    phantom). The standard measuring distance was 10 mm (above 1 GHz) and 15 mm (below 1 GHz) from dipole
    center to the simulating liquid surface.
   The coarse grid with a grid spacing of 15 mm was aligned with the dipole.
    For 5 GHz band - The coarse grid with a grid spacing of 10 mm was aligned with the dipole.
   Special 7x7x7 (below 3 GHz) and/or 8x8x7 (above 3 GHz) fine cube was chosen for the cube.
   Distance between probe sensors and phantom surface was set to 3 mm.
    For 5 GHz band - Distance between probe sensors and phantom surface was set to 2.5 mm
   The dipole input power (forward power) was 100 mW.
   The results are normalized to 1 W input power.




                                                   Page 15 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20081-S1A                                                                                          Issue Date: 4/1/2015
Reference Target SAR Values
The reference SAR values can be obtained from the calibration certificate of system validation dipoles
                                                                                              Target SAR Values (W/kg)
  System Dipole           Serial No.          Cal. Date        Freq. (MHz)
                                                                                   1g/10g              Head              Body
                                                                                     1g                53.0              50.2
    D2450V2                  706              5/20/2014            2450
                                                                                    10g                24.5              23.4

System Check Results
The 1-g and 10-g SAR measured with a reference dipole, using the required tissue-equivalent medium at the test
frequency, must be within 10% of the manufacturer calibrated dipole SAR target.

SAR Lab G
                     System Dipole                                     Measured Results
                                                     T.S.                                         Target       Delta       Plot
 Date Tested                                                       Zoom Scan to   Normalize
                   Type            Serial #         Liquid                                      (Ref. Value)   ±10 %       No.
                                                                     100 mW        to 1 W
                                                             1g        5.42         54.20          53.00        2.26
  2/16/2015       D2450V2              706        Head
                                                             10g       2.47         24.70          24.50        0.82
                                                             1g        4.85         48.50          50.20       -3.39
  2/16/2015       D2450V2              706        Body                                                                      1,2
                                                             10g       2.24         22.40          23.40       -4.27




                                                   Page 16 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20081-S1A                                                                             Issue Date: 4/1/2015

8. Conducted Output Power Measurements
8.1.         Wi-Fi 2.4GHz (DTS Band)
Measured Results
      Band                                                   Freq.     Avg Pwr (dBm)    Max Output   SAR Test
                   Mode        Data Rate       Ch #                                                              Note(s)
     (GHz)                                                  (MHz)                      Power (dBm)   (Yes/No)
                                                 1           2412          17.0
                  802.11b       1 Mbps           6           2437          17.0           18.0         Yes
                                                11           2462          17.0
                                                 1           2412
       2.4        802.11g       6 Mbps           6           2437                         15.0          No         1
                                                11           2462
                                                                       Not Required
                                                 1           2412
                  802.11n
                                 MCS0            6           2437                         14.0          No         1
                  (HT20)
                                                11           2462


Note(s):
1.   Output Power and SAR is not required for 802.11g/n HT20 channels when the highest reported SAR for DSSS is adjusted
     by the ratio of OFDM to DSSS specified maximum output power and the adjusted SAR is ≤ 1.2 W/kg.

8.2.         Bluetooth
Maximum tune-up tolerance limit is 10.0 dBm from the rated nominal maximum output power. This power level
qualifies for exclusion of SAR testing.




                                                   Page 17 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20081-S1A                                                                                       Issue Date: 4/1/2015

9. Measured and Reported (Scaled) SAR Results
SAR Test Reduction criteria are as follows:

KDB 248227 D01 SAR meas for 802.11 v02:
SAR test reduction for 802.11 Wi-Fi transmission mode configurations are considered separately for DSSS and OFDM. An initial
test position is determined to reduce the number of tests required for certain exposure configurations with multiple test positions.
An initial test configuration is determined for each frequency band and aggregated band according to maximum output power,
channel bandwidth, wireless mode configurations and other operating parameters to streamline the measurement requirements.
For 2.4 GHz DSSS, either the initial test position or DSSS procedure is applied to reduce the number of SAR tests; these are
mutually exclusive. For OFDM, an initial test position is only applicable to next to the ear, UMPC mini-tablet and hotspot mode
configurations, which is tested using the initial test configuration to facilitate test reduction. For other exposure conditions with a
fixed test position, SAR test reduction is determined using only the initial test configuration.
     The multiple test positions require SAR measurements in head, hotspot mode or UMPC mini-tablet configurations may be
reduced according to the highest reported SAR determined using the initial test position(s) by applying the DSSS or OFDM SAR
measurement procedures in the required wireless mode test configuration(s). The initial test position(s) is measured using the
highest measured maximum output power channel in the required wireless mode test configuration(s). When the reported SAR
for the initial test position is:

        ≤ 0.4 W/kg, further SAR measurement is not required for the other test positions in that exposure configuration and
         wireless mode combination within the frequency band or aggregated band. DSSS and OFDM configurations are
         considered separately according to the required SAR procedures.
        > 0.4 W/kg, SAR is repeated using the same wireless mode test configuration tested in the initial test position to
         measure the subsequent next closet/smallest test separation distance and maximum coupling test position, on the
         highest maximum output power channel, until the reported SAR is ≤ 0.8 W/kg or all required test positions are tested.
         o For subsequent test positions with equivalent test separation distance or when exposure is dominated by coupling
              conditions, the position for maximum coupling condition should be tested.
         o When it is unclear, all equivalent conditions must be tested.
        For all positions/configurations tested using the initial test position and subsequent test positions, when the reported
         SAR is > 0.8 W/kg, measure the SAR for these positions/configurations on the subsequent next highest measured
         output power channel(s) until the reported SAR is ≤ 1.2 W/kg or all required test channels are considered.
         o The additional power measurements required for this step should be limited to those necessary for identifying
              subsequent highest output power channels to apply the test reduction.




                                                   Page 18 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20081-S1A                                                                                                    Issue Date: 4/1/2015

9.1.         Wi-Fi (DTS Band)
                                                                                        Power (dBm)       1-g SAR (W/kg)    10-g SAR (W/kg)
 Frequency               RF Exposure      Dist.                              Freq.                                                            Plot
                Mode                              Test Position   Ch #.              Tune-up
   Band                   Conditions     (mm)                               (MHz)                Meas.   Meas.     Scaled   Meas.    Scaled   No.
                                                                                       limit
                                                                    1      2412.0     18.0       17.0                       0.406     0.511    1
                           Extremity       0          Rear          6      2437.0     18.0       17.0                       0.351     0.442
  2.4GHz       802.11b
                                                                   11      2462.0     18.0       17.0                       0.388     0.488
                         Next to Mouth    10         Front          6      2437.0     18.0       17.0    0.119     0.150                       2


9.2.       Bluetooth
Standalone SAR Test Exclusion Considerations & Estimated SAR
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)]·[√f(GHz)] ≤ 3.0, for 1-g SAR
and ≤ 7.5 for 10-g extremity SAR, where
          f(GHz) is the RF channel transmit frequency in GHz
          Power and distance are rounded to the nearest mW and mm before calculation
          The result is rounded to one decimal place for comparison
The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a
distance of 5 mm is applied to determine SAR test exclusion.

When the standalone SAR test exclusion is applied to an antenna that transmits simultaneously with other
antennas, the standalone SAR must be estimated according to following to determine simultaneous transmission
SAR test exclusion:
          (max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)]·[√f(GHz)/x] W/kg for test
           separation distances ≤ 50 mm;
                    where x = 7.5 for 1-g SAR, and x = 18.75 for 10-g SAR.
          0.4 W/kg for 1-g SAR and 1.0 W/kg for 10-g SAR, when the test separation distances is > 50 mm.


Extremity Exposure Conditions
  Max. tune-up tolerance limit                Min. test             Frequency            SAR test            Test
                                             separation               (GHz)              exclusion       Configuration
     (dBm)                 (mW)            distance (mm)                                  Result*
        10.0                 10                      5                    2.480                3.1         Extremity

Conclusion:
*: The computed value is < 7.5; therefore, Bluetooth qualifies for Standalone SAR test exclusion.


Next to Mouth Exposure Conditions
  Max. tune-up tolerance limit                Min. test             Frequency            SAR test            Test
                                             separation               (GHz)              exclusion       Configuration
     (dBm)                 (mW)            distance (mm)                                  Result*
        10.0                 10                     10                    2.480                1.6       Next to Mouth

Conclusion:
*: The computed value is < 3; therefore, Bluetooth qualifies for Standalone SAR test exclusion.




                                                   Page 19 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20081-S1A                                                                                  Issue Date: 4/1/2015

10.       SAR Measurement Variability
In accordance with published RF Exposure KDB 865664 D01 SAR measurement 100 MHz to 6 GHz. These
additional measurements are repeated after the completion of all measurements requiring the same head or body
tissue-equivalent medium in a frequency band. The test device should be returned to ambient conditions (normal
room temperature) with the battery fully charged before it is re-mounted on the device holder for the repeated
measurement(s) to minimize any unexpected variations in the repeated results.

1) Repeated measurement is not required when the original highest measured SAR is < 0.80 W/kg; steps 2)
   through 4) do not apply.
2) When the original highest measured SAR is ≥ 0.80 W/kg, repeat that measurement once.
3) Perform a second repeated measurement only if the ratio of largest to smallest SAR for the original and first
   repeated measurements is > 1.20 or when the original or repeated measurement is ≥ 1.45 W/kg (~ 10% from
   the 1-g SAR limit).
4) Perform a third repeated measurement only if the original, first or second repeated measurement is ≥1.5 W/kg
   and the ratio of largest to smallest SAR for the original, first and second repeated measurements is > 1.20.

 Frequency                                                                Repeated      Highest       Repeated     Largest to
               Air Interface     RF Exposure Conditions   Test Position
   Band                                                                     SAR      Measured SAR   Measured SAR    Smallest
                                       Extremity              Rear           No          0.351          N/A           N/A
   2400      Wi-Fi 802.11b/g/n
                                     Next to Mouth           Front          No          0.119           N/A           N/A




                                                   Page 20 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20081-S1A                                                                          Issue Date: 4/1/2015

11.     Simultaneous Transmission SAR Analysis
N/A

Wi-Fi 2.4GHz Radio cannot transmit simultaneously with Bluetooth Radio.




                                                   Page 21 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I20081-S1A                                                                          Issue Date: 4/1/2015

Appendixes
Refer to separated files for the following appendixes.

A_15I20081v0 SAR Photos & Ant. Locations

B_15I20081v0 SAR System Check Plots

C_15I20081v1 SAR Highest Test Plots

D_15I20081v0 SAR Tissue Ingredients

E_15I20081v0 SAR Probe Cal. Certificates

F_15I20081v0 SAR Dipole Cal. Certificates




                                                END OF REPORT




                                                   Page 22 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.



Document Created: 2015-04-01 09:20:08
Document Modified: 2015-04-01 09:20:08

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC