SAR APpendix C

FCC ID: ZNFVS986

RF Exposure Info

Download: PDF
FCCID_2595600

Test Laboratory: UL Verification Services Inc. SAR Lab G                    Date/Time: 4/1/2015 2:29:38 PM

GSM 850

Frequency: 836.6 MHz; Duty Cycle: 1:8;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                               3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.99 S/m; εr = 53.177; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/14/2014
- Probe: EX3DV4 - SN3686; ConvF(8.49, 8.49, 8.49); Calibrated: 2/23/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: ELI v5.0 B; Type: QDOVA002AA; Serial: 1248

Front/Voice_ ch 190/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.822 W/kg

Front/Voice_ ch 190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 29.191 V/m; Power Drift = -0.04 dB
Peak SAR (extrapolated) = 1.20 W/kg
SAR(1 g) = 0.669 W/kg; SAR(10 g) = 0.372 W/kg
Maximum value of SAR (measured) = 0.892 W/kg




                      0 dB = 0.892 W/kg = -0.50 dBW/kg




                                                                                                             Plot No. 1


Test Laboratory: UL Verification Services Inc. SAR Lab G                    Date/Time: 4/1/2015 4:49:13 PM

GSM 850

Frequency: 836.6 MHz; Duty Cycle: 1:4;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.902 S/m; εr = 42.025; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/14/2014
- Probe: EX3DV4 - SN3686; ConvF(8.65, 8.65, 8.65); Calibrated: 2/23/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: SAM A; Type: SAM; Serial: 1831

RHS/Touch_GPRS 2 slots ch 190 w/cover/Area Scan (7x12x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 0.678 W/kg

RHS/Touch_GPRS 2 slots ch 190 w/cover/Zoom Scan (5x5x7)/Cube 0: Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 27.017 V/m; Power Drift = -0.07 dB
Peak SAR (extrapolated) = 1.05 W/kg
SAR(1 g) = 0.717 W/kg; SAR(10 g) = 0.432 W/kg
Maximum value of SAR (measured) = 0.657 W/kg




                      0 dB = 0.657 W/kg = -1.82 dBW/kg




                                                                                                             Plot No. 2


Test Laboratory: UL Verification Services Inc. SAR Lab B                    Date/Time: 3/30/2015 7:45:17 PM

GSM 1900

Frequency: 1880 MHz; Duty Cycle: 1:4;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                               3
Medium parameters used: f = 1880 MHz; σ = 1.382 S/m; εr = 38.44; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 5/15/2014
- Probe: EX3DV4 - SN3751; ConvF(7.14, 7.14, 7.14); Calibrated: 11/14/2014;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: SAM; Type: QD000PCD; Serial: 1632

LHS/Touch_GPRS 2 slot ch 661/Area Scan (7x12x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.635 W/kg

LHS/Touch_GPRS 2 slot ch 661/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 20.998 V/m; Power Drift = 0.19 dB
Peak SAR (extrapolated) = 0.978 W/kg
SAR(1 g) = 0.617 W/kg; SAR(10 g) = 0.374 W/kg
Maximum value of SAR (measured) = 0.771 W/kg




                      0 dB = 0.771 W/kg = -1.13 dBW/kg




                                                                                                              Plot No. 3


Test Laboratory: UL Verification Services Inc. SAR Lab B                    Date/Time: 3/31/2015 5:30:32 PM

GSM 1900

Frequency: 1880 MHz; Duty Cycle: 1:4;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 1880 MHz; σ = 1.545 S/m; εr = 51.544; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 5/15/2014
- Probe: EX3DV4 - SN3751; ConvF(6.9, 6.9, 6.9); Calibrated: 11/14/2014;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 (B); Type: QDOVA001BB; Serial: 1118

Edge 4/GPRS 2 slot ch 661/Area Scan (7x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.465 W/kg

Edge 4/GPRS 2 slot ch 661/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 13.652 V/m; Power Drift = 0.17 dB
Peak SAR (extrapolated) = 0.670 W/kg
SAR(1 g) = 0.428 W/kg; SAR(10 g) = 0.262 W/kg
Maximum value of SAR (measured) = 0.533 W/kg




                      0 dB = 0.533 W/kg = -2.73 dBW/kg




                                                                                                               Plot No. 4


Test Laboratory: UL Verification Services Inc. SAR Lab G                    Date/Time: 4/1/2015 10:17:22 PM

W-CDMA Band V

Frequency: 836.6 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.902 S/m; εr = 42.025; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/14/2014
- Probe: EX3DV4 - SN3686; ConvF(8.65, 8.65, 8.65); Calibrated: 2/23/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM A; Type: SAM; Serial: 1831

RHS/Touch_Rel 99 RMC ch 4183/Area Scan (8x12x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.536 W/kg

RHS/Touch_Rel 99 RMC ch 4183/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 24.166 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 0.614 W/kg
SAR(1 g) = 0.477 W/kg; SAR(10 g) = 0.362 W/kg
Maximum value of SAR (measured) = 0.535 W/kg




                      0 dB = 0.535 W/kg = -2.72 dBW/kg




                                                                                                               Plot No. 5


Test Laboratory: UL Verification Services Inc. SAR Lab G                    Date/Time: 4/1/2015 8:07:03 PM

W-CDMA Band V

Frequency: 836.6 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                               3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.99 S/m; εr = 53.177; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/14/2014
- Probe: EX3DV4 - SN3686; ConvF(8.49, 8.49, 8.49); Calibrated: 2/23/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 B; Type: QDOVA002AA; Serial: 1248

Front/Rel 99 RMC Ch 4183/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.966 W/kg

Front/Rel 99 RMC Ch 4183/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 24.052 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 1.43 W/kg
SAR(1 g) = 0.781 W/kg; SAR(10 g) = 0.433 W/kg
Maximum value of SAR (measured) = 1.02 W/kg




                      0 dB = 1.02 W/kg = 0.09 dBW/kg




                                                                                                               Plot No. 6


Test Laboratory: UL Verification Services Inc. SAR Lab B                    Date/Time: 3/27/2015 2:19:29 PM

W-CDMA Band II

Frequency: 1880 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                               3
Medium parameters used: f = 1880 MHz; σ = 1.569 S/m; εr = 52.67; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 5/15/2014
- Probe: EX3DV4 - SN3751; ConvF(6.9, 6.9, 6.9); Calibrated: 11/14/2014;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: ELI v5.0 (B); Type: QDOVA001BB; Serial: 1118

Front/Rel 99 RMC Ch 9400/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.747 W/kg

Front/ Rel 99 RMC Ch 9400/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 22.271 V/m; Power Drift = -0.10 dB
Peak SAR (extrapolated) = 1.13 W/kg
SAR(1 g) = 0.604 W/kg; SAR(10 g) = 0.348 W/kg
Maximum value of SAR (measured) = 0.832 W/kg




                      0 dB = 0.832 W/kg = -0.80 dBW/kg




                                                                                                              Plot No. 7


Test Laboratory: UL Verification Services Inc. SAR Lab B                    Date/Time: 3/30/2015 5:30:41 PM

W-CDMA Band II

Frequency: 1852.4 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                 3
Medium parameters used (interpolated): f = 1852.4 MHz; σ = 1.357 S/m; εr = 38.692; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 5/15/2014
- Probe: EX3DV4 - SN3751; ConvF(7.14, 7.14, 7.14); Calibrated: 11/14/2014;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: SAM; Type: QD000PCD; Serial: 1632

LHS/Touch_Rel 99 RMC ch 9262 w/cover/Area Scan (8x12x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 0.925 W/kg

LHS/Touch_Rel 99 RMC ch 9262 w/cover/Zoom Scan (5x5x7)/Cube 0: Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 26.655 V/m; Power Drift = -0.07 dB
Peak SAR (extrapolated) = 1.29 W/kg
SAR(1 g) = 0.837 W/kg; SAR(10 g) = 0.509 W/kg
Maximum value of SAR (measured) = 1.04 W/kg




                      0 dB = 1.04 W/kg = 0.17 dBW/kg




                                                                                                              Plot No. 8


Test Laboratory: UL Verification Services Inc. SAR Lab G                    Date/Time: 3/31/2015 6:36:56 PM

CDMA BC0

Frequency: 836.52 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                 3
Medium parameters used (interpolated): f = 836.52 MHz; σ = 0.902 S/m; εr = 42.024; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/14/2014
- Probe: EX3DV4 - SN3686; ConvF(8.65, 8.65, 8.65); Calibrated: 2/23/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM A; Type: SAM; Serial: 1831

RHS/Touch_1xRTT_RC3 SO55 ch 384/Area Scan (7x12x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.693 W/kg

RHS/Touch_1xRTT_RC3 SO55 ch 384/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 27.474 V/m; Power Drift = -0.00 dB
Peak SAR (extrapolated) = 0.803 W/kg
SAR(1 g) = 0.608 W/kg; SAR(10 g) = 0.454 W/kg
Maximum value of SAR (measured) = 0.688 W/kg




                      0 dB = 0.688 W/kg = -1.62 dBW/kg




                                                                                                               Plot No. 9


Test Laboratory: UL Verification Services Inc. SAR Lab G                    Date/Time: 4/1/2015 2:11:23 AM

CDMA BC0

Frequency: 836.52 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.52 MHz; σ = 0.99 S/m; εr = 53.178; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/14/2014
- Probe: EX3DV4 - SN3686; ConvF(8.49, 8.49, 8.49); Calibrated: 2/23/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: ELI v5.0 B; Type: QDOVA002AA; Serial: 1248

Front/1xRTT RC3 SO32, Rel. 0 Ch 384 W/ Cover/Area Scan (8x14x1): Measurement grid:
dx=15mm, dy=15mm
Maximum value of SAR (measured) = 1.19 W/kg

Front/1xRTT RC3 SO32, Rel. 0 Ch 384 With Cover/Zoom Scan (5x5x7)/Cube 0: Measurement
grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 35.044 V/m; Power Drift = 0.07 dB
Peak SAR (extrapolated) = 1.63 W/kg
SAR(1 g) = 0.905 W/kg; SAR(10 g) = 0.503 W/kg
Maximum value of SAR (measured) = 1.21 W/kg




                      0 dB = 1.21 W/kg = 0.83 dBW/kg




                                                                                                             Plot No. 10


Test Laboratory: UL Verification Services Inc. SAR Lab B                    Date/Time: 4/1/2015 5:13:15 PM

CDMA BC1

Frequency: 1851.25 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                   3
Medium parameters used (interpolated): f = 1851.25 MHz; σ = 1.355 S/m; ε r = 38.692; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 5/15/2014
- Probe: EX3DV4 - SN3751; ConvF(7.14, 7.14, 7.14); Calibrated: 11/14/2014;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: SAM; Type: QD000PCD; Serial: 1632

LHS/ Touch_Rel 99 RMC SO55 ch 25/Area Scan (7x12x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 1.19 W/kg

LHS/ Touch_Rel 99 RMC SO55 ch 25/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 29.269 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 1.50 W/kg
SAR(1 g) = 0.970 W/kg; SAR(10 g) = 0.601 W/kg
Maximum value of SAR (measured) = 1.18 W/kg




                      0 dB = 1.18 W/kg = 0.72 dBW/kg




                                                                                                             Plot No. 11


Test Laboratory: UL Verification Services Inc. SAR Lab B                    Date/Time: 3/27/2015 7:15:39 PM

CDMA BC1

Frequency: 1880 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                               3
Medium parameters used: f = 1880 MHz; σ = 1.569 S/m; εr = 52.67; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 5/15/2014
- Probe: EX3DV4 - SN3751; ConvF(6.9, 6.9, 6.9); Calibrated: 11/14/2014;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 (B); Type: QDOVA001BB; Serial: 1118

Front/1xRTT RC3 SO32, Rel. 0 Ch 600/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.753 W/kg

Front/1xRTT RC3 SO32, Rel. 0 Ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 22.673 V/m; Power Drift = -0.06 dB
Peak SAR (extrapolated) = 1.05 W/kg
SAR(1 g) = 0.605 W/kg; SAR(10 g) = 0.360 W/kg
Maximum value of SAR (measured) = 0.749 W/kg




                      0 dB = 0.749 W/kg = -1.26 dBW/kg




                                                                                                           Plot No. 12


Test Laboratory: UL Verification Services Inc. SAR Lab B                    Date/Time: 3/27/2015 7:37:33 PM

CDMA BC1

Frequency: 1880 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                               3
Medium parameters used: f = 1880 MHz; σ = 1.569 S/m; εr = 52.67; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 5/15/2014
- Probe: EX3DV4 - SN3751; ConvF(6.9, 6.9, 6.9); Calibrated: 11/14/2014;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 (B); Type: QDOVA001BB; Serial: 1118

Edge 4/1xRTT RC3 SO32, Rel. 0 Ch 600/Area Scan (6x13x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 0.790 W/kg

Edge 4/1xRTT RC3 SO32, Rel. 0 Ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 22.673 V/m; Power Drift = -0.06 dB
Peak SAR (extrapolated) = 1.06 W/kg
SAR(1 g) = 0.681 W/kg; SAR(10 g) = 0.418 W/kg
Maximum value of SAR (measured) = 0.846 W/kg




                      0 dB = 0.846 W/kg = -0.73 dBW/kg




                                                                                                               Plot No. 13


Test Laboratory: UL Verification Services Inc. SAR Lab B                    Date/Time: 3/28/2015 6:23:27 PM

LTE Band 2

Frequency: 1880 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                               3
Medium parameters used: f = 1880 MHz; σ = 1.423 S/m; εr = 39.51; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 5/15/2014
- Probe: EX3DV4 - SN3751; ConvF(7.14, 7.14, 7.14); Calibrated: 11/14/2014;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM; Type: QD000PCD; Serial: 1632

LHS/Touch_QPSK RB 1/49 ch 18900/Area Scan (7x12x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.916 W/kg

LHS/Touch_QPSK RB 1/49 ch 18900/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 25.309 V/m; Power Drift = 0.00 dB
Peak SAR (extrapolated) = 1.20 W/kg
SAR(1 g) = 0.762 W/kg; SAR(10 g) = 0.464 W/kg
Maximum value of SAR (measured) = 0.934 W/kg




                      0 dB = 0.934 W/kg = -0.30 dBW/kg




                                                                                                               Plot No. 14


Test Laboratory: UL Verification Services Inc. SAR Lab B                    Date/Time: 3/28/2015 2:57:47 PM

LTE Band 2

Frequency: 1880 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                               3
Medium parameters used: f = 1880 MHz; σ = 1.569 S/m; εr = 52.67; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 5/15/2014
- Probe: EX3DV4 - SN3751; ConvF(6.9, 6.9, 6.9); Calibrated: 11/14/2014;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 (B); Type: QDOVA001BB; Serial: 1118

Rear/QPSK, Ch. 18900_RB 1/49/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.641 W/kg

Rear/QPSK, Ch. 18900_RB 1/49/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 20.251 V/m; Power Drift = 0.07 dB
Peak SAR (extrapolated) = 0.826 W/kg
SAR(1 g) = 0.569 W/kg; SAR(10 g) = 0.379 W/kg
Maximum value of SAR (measured) = 0.680 W/kg




                      0 dB = 0.680 W/kg = -1.67 dBW/kg




                                                                                                               Plot No. 15


Test Laboratory: UL Verification Services Inc. SAR Lab G                    Date/Time: 3/26/2015 8:54:48 PM

LTE Band 4

Frequency: 1732.5 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                3
Medium parameters used (interpolated): f = 1732.5 MHz; σ = 1.42 S/m; εr = 53.071; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/14/2014
- Probe: EX3DV4 - SN3686; ConvF(7.28, 7.28, 7.28); Calibrated: 2/23/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: ELI v5.0 B; Type: QDOVA002AA; Serial: 1248

Rear/QPSK, Ch. 20175_RB 1/99/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 1.25 W/kg

Rear/QPSK, Ch. 20175_RB 1/99/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 29.765 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 1.57 W/kg
SAR(1 g) = 1.07 W/kg; SAR(10 g) = 0.695 W/kg
Maximum value of SAR (measured) = 1.29 W/kg




                      0 dB = 1.29 W/kg = 1.11 dBW/kg




                                                                                                           Plot No. 16


Test Laboratory: UL Verification Services Inc. SAR Lab G                    Date/Time: 3/27/2015 11:22:30 PM

LTE Band 4

Frequency: 1732.5 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                 3
Medium parameters used (interpolated): f = 1732.5 MHz; σ = 1.322 S/m; εr = 40.995; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/14/2014
- Probe: EX3DV4 - SN3686; ConvF(7.65, 7.65, 7.65); Calibrated: 2/23/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: SAM A; Type: SAM; Serial: 1831

LHS/Touch_QPSK RB 1/99 ch 20175 w/Cover/Area Scan (7x12x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 0.987 W/kg

LHS/Touch_QPSK RB 1/99 ch 20175 w/Cover/Zoom Scan (5x5x7)/Cube 0: Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 27.758 V/m; Power Drift = 0.05 dB
Peak SAR (extrapolated) = 1.28 W/kg
SAR(1 g) = 0.866 W/kg; SAR(10 g) = 0.546 W/kg
Maximum value of SAR (measured) = 1.04 W/kg




                      0 dB = 1.04 W/kg = 0.17 dBW/kg




                                                                                                           Plot No. 17


Test Laboratory: UL Verification Services Inc. SAR Lab G                    Date/Time: 3/31/2015 2:47:55 PM

LTE Band 5

Frequency: 836.5 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.5 MHz; σ = 0.902 S/m; εr = 42.024; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/14/2014
- Probe: EX3DV4 - SN3686; ConvF(8.65, 8.65, 8.65); Calibrated: 2/23/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM A; Type: SAM; Serial: 1831

RHS/Touch_QPSK RB 1/49_ch 20525/Area Scan (7x12x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.516 W/kg

RHS/Touch_QPSK RB 1/49_ch 20525/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 23.983 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 0.602 W/kg
SAR(1 g) = 0.462 W/kg; SAR(10 g) = 0.348 W/kg
Maximum value of SAR (measured) = 0.523 W/kg




                      0 dB = 0.523 W/kg = -2.81 dBW/kg




                                                                                                               Plot No. 18


Test Laboratory: UL Verification Services Inc. SAR Lab G                    Date/Time: 3/31/2015 2:06:55 PM

LTE Band 5

Frequency: 836.5 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                               3
Medium parameters used (interpolated): f = 836.5 MHz; σ = 0.99 S/m; εr = 53.178; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/14/2014
- Probe: EX3DV4 - SN3686; ConvF(8.49, 8.49, 8.49); Calibrated: 2/23/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 B; Type: QDOVA002AA; Serial: 1248

Front/QPSK, Ch. 20525_RB 1/49/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.641 W/kg

Front/QPSK, Ch. 20525_RB 1/49/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 26.003 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 0.949 W/kg
SAR(1 g) = 0.549 W/kg; SAR(10 g) = 0.312 W/kg
Maximum value of SAR (measured) = 0.712 W/kg




                      0 dB = 0.712 W/kg = -1.48 dBW/kg




                                                                                                               Plot No. 19


Test Laboratory: UL Verification Services Inc. SAR Lab B                    Date/Time: 4/3/2015 5:44:02 PM

LTE Band 7

Frequency: 2535 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 2535 MHz; σ = 1.819 S/m; εr = 39.394; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 5/15/2014
- Probe: EX3DV4 - SN3751; ConvF(6.37, 6.37, 6.37); Calibrated: 11/14/2014;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: SAM; Type: QD000PCD; Serial: 1632

LHS/Touch_QPSK_ch 21100 RB 1/0/Area Scan (9x15x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.694 W/kg

LHS/Touch_QPSK_ch 21100 RB 1/0/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 19.711 V/m; Power Drift = -0.03 dB
Peak SAR (extrapolated) = 0.980 W/kg
SAR(1 g) = 0.548 W/kg; SAR(10 g) = 0.296 W/kg
Maximum value of SAR (measured) = 0.719 W/kg




                      0 dB = 0.719 W/kg = -1.43 dBW/kg




                                                                                                             Plot No. 20


Test Laboratory: UL Verification Services Inc. SAR Lab B                    Date/Time: 4/2/2015 11:26:13 AM

LTE Band 7

Frequency: 2535 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                               3
Medium parameters used: f = 2535 MHz; σ = 2.105 S/m; εr = 52.33; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 5/15/2014
- Probe: EX3DV4 - SN3751; ConvF(6.28, 6.28, 6.28); Calibrated: 11/14/2014;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1117

Rear/QPSK, Ch. 21100 RB 1/0/Area Scan (9x18x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.568 W/kg

Rear/QPSK, Ch. 21100 RB 1/0/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 16.466 V/m; Power Drift = -0.04 dB
Peak SAR (extrapolated) = 0.868 W/kg
SAR(1 g) = 0.428 W/kg; SAR(10 g) = 0.221 W/kg
Maximum value of SAR (measured) = 0.583 W/kg




                      0 dB = 0.583 W/kg = -2.34 dBW/kg




                                                                                                               Plot No. 21


Test Laboratory: UL Verification Services Inc. SAR Lab B                    Date/Time: 4/2/2015 5:03:06 PM

LTE Band 7

Frequency: 2535 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                               3
Medium parameters used: f = 2535 MHz; σ = 2.105 S/m; εr = 52.33; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 5/15/2014
- Probe: EX3DV4 - SN3751; ConvF(6.28, 6.28, 6.28); Calibrated: 11/14/2014;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1117

Edge 4/QPSK_ch 21100 RB 1/0/Area Scan (10x16x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.572 W/kg

Edge 4/QPSK_ch 21100 RB 1/0/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 16.337 V/m; Power Drift = 0.13 dB
Peak SAR (extrapolated) = 0.917 W/kg
SAR(1 g) = 0.449 W/kg; SAR(10 g) = 0.226 W/kg
Maximum value of SAR (measured) = 0.618 W/kg




                      0 dB = 0.618 W/kg = -2.09 dBW/kg




                                                                                                             Plot No. 22


Test Laboratory: UL Verification Services Inc. SAR Lab G                    Date/Time: 4/2/2015 5:39:37 PM

LTE Band 13

Frequency: 782 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                              3
Medium parameters used (interpolated): f = 782 MHz; σ = 0.929 S/m; εr = 39.997; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/14/2014
- Probe: EX3DV4 - SN3686; ConvF(8.88, 8.88, 8.88); Calibrated: 2/23/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM A; Type: SAM; Serial: 1831

RHS/Touch_QPSK RB 1/25_ch 23230/Area Scan (7x12x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.403 W/kg

RHS/Touch_QPSK RB 1/25_ch 23230/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 20.682 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 0.481 W/kg
SAR(1 g) = 0.360 W/kg; SAR(10 g) = 0.266 W/kg
Maximum value of SAR (measured) = 0.406 W/kg




                      0 dB = 0.406 W/kg = -3.91 dBW/kg




                                                                                                               Plot No. 23


Test Laboratory: UL Verification Services Inc. SAR Lab G                    Date/Time: 4/2/2015 9:08:35 PM

LTE Band 13

Frequency: 782 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                              3
Medium parameters used (interpolated): f = 782 MHz; σ = 1.003 S/m; εr = 53.786; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/14/2014
- Probe: EX3DV4 - SN3686; ConvF(8.7, 8.7, 8.7); Calibrated: 2/23/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI A; Type: QDOVA002AA; Serial: 1258

Front/QPSK, Ch. 23230_RB 1/25/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.551 W/kg

Front/QPSK, Ch. 23230_RB 1/25/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 23.825 V/m; Power Drift = -0.00 dB
Peak SAR (extrapolated) = 0.887 W/kg
SAR(1 g) = 0.493 W/kg; SAR(10 g) = 0.277 W/kg
Maximum value of SAR (measured) = 0.627 W/kg




                      0 dB = 0.627 W/kg = -2.03 dBW/kg




                                                                                                               Plot No. 24


Test Laboratory: The name of your organization                     Date/Time: 4/9/2015 8:15:50 AM

Wi-Fi 2.4GHz

Frequency: 2437 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                               3
Medium parameters used (interpolated): f = 2437 MHz; σ = 1.787 S/m; εr = 38.817; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 5/15/2014
- Probe: EX3DV4 - SN3751; ConvF(6.61, 6.61, 6.61); Calibrated: 11/14/2014;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: SAM; Type: QD000PCD; Serial: 1632

LHS/Tilt_802.11b_ch 6 w/cover/Area Scan (9x17x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.404 W/kg

LHS/Tilt_802.11b_ch 6 w/cover/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 14.623 V/m; Power Drift = -0.03 dB
Peak SAR (extrapolated) = 0.689 W/kg
SAR(1 g) = 0.296 W/kg; SAR(10 g) = 0.131 W/kg
Maximum value of SAR (measured) = 0.427 W/kg




                      0 dB = 0.427 W/kg = -3.70 dBW/kg




                                                                                                           Plot No. 25


Test Laboratory: UL Verification Services Inc. SAR Lab B                    Date/Time: 4/8/2015 5:02:21 PM

Wi-Fi 2.4GHz

Frequency: 2437 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                               3
Medium parameters used (interpolated): f = 2437 MHz; σ = 1.787 S/m; εr = 38.817; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 5/15/2014
- Probe: EX3DV4 - SN3751; ConvF(6.61, 6.61, 6.61); Calibrated: 11/14/2014;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1117

Rear/802.11b_ch 6 w/cover/Area Scan (9x16x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.219 W/kg

Rear/802.11b_ch 6 w/cover/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 11.089 V/m; Power Drift = -0.14 dB
Peak SAR (extrapolated) = 0.380 W/kg
SAR(1 g) = 0.179 W/kg; SAR(10 g) = 0.083 W/kg
Maximum value of SAR (measured) = 0.251 W/kg




                      0 dB = 0.251 W/kg = -6.00 dBW/kg




                                                                                                             Plot No. 26


Test Laboratory: UL Verification Services Inc. SAR Lab E                     Date/Time: 4/10/2015 3:29:32 PM

Wi-Fi 5GHz

Frequency: 5300 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                               3
Medium parameters used: f = 5300 MHz; σ = 4.52 S/m; εr = 36.694; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1257; Calibrated: 9/29/2014
- Probe: EX3DV4 - SN3772; ConvF(4.82, 4.82, 4.82); Calibrated: 2/23/2015;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Phantom: SAM with CRP; Type: SAM;

LHS/Tilt_802.11a_Ch 60/Area Scan (11x21x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 0.958 W/kg

LHS/Tilt_802.11a_Ch 60/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm
Reference Value = 14.074 V/m; Power Drift = 0.05 dB
Peak SAR (extrapolated) = 1.90 W/kg
SAR(1 g) = 0.488 W/kg; SAR(10 g) = 0.149 W/kg
Maximum value of SAR (measured) = 0.938 W/kg




                      0 dB = 0.938 W/kg = -0.28 dBW/kg




                                                                                                               Plot No. 27


Test Laboratory: UL Verification Services Inc. SAR Lab E                     Date/Time: 4/14/2015 4:26:54 PM

Wi-Fi 5GHz

Frequency: 5300 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 5300 MHz; σ = 5.446 S/m; εr = 46.961; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1257; Calibrated: 9/29/2014
- Probe: EX3DV4 - SN3772; ConvF(4.14, 4.14, 4.14); Calibrated: 2/23/2015;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 B; Type: QDOVA002AA; Serial: 1180

Rear/802.11a_Ch 60 w/cover/Area Scan (11x19x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 0.443 W/kg

Rear/802.11a_Ch 60 w/cover/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=2mm
Reference Value = 8.932 V/m; Power Drift = 0.12 dB
Peak SAR (extrapolated) = 0.987 W/kg
SAR(1 g) = 0.269 W/kg; SAR(10 g) = 0.099 W/kg
Maximum value of SAR (measured) = 0.499 W/kg




                      0 dB = 0.499 W/kg = -3.02 dBW/kg




                                                                                                               Plot No. 28


Test Laboratory: UL Verification Services Inc. SAR Lab G                    Date/Time: 4/14/2015 3:07:50 PM

Wi-Fi 5GHz

Frequency: 5580 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 5580 MHz; σ = 5.028 S/m; εr = 35.345; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1433; Calibrated: 3/12/2015
- Probe: EX3DV4 - SN3686; ConvF(4.06, 4.06, 4.06); Calibrated: 2/23/2015;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Phantom: SAM A; Type: SAM; Serial: 1831

LHS/Tilt_802.11a_Ch 116/Area Scan (11x21x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 0.828 W/kg

LHS/Tilt_802.11a_Ch 116/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=2mm
Reference Value = 12.329 V/m; Power Drift = 0.10 dB
Peak SAR (extrapolated) = 1.52 W/kg
SAR(1 g) = 0.382 W/kg; SAR(10 g) = 0.109 W/kg
Maximum value of SAR (measured) = 0.854 W/kg




                      0 dB = 0.854 W/kg = -0.69 dBW/kg




                                                                                                               Plot No. 29


Test Laboratory: UL Verification Services Inc. SAR Lab E                    Date/Time: 4/14/2015 3:42:08 PM

Wi-Fi 5GHz

Frequency: 5580 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 5580 MHz; σ = 5.959 S/m; εr = 47.354; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1257; Calibrated: 9/29/2014
- Probe: EX3DV4 - SN3772; ConvF(3.6, 3.6, 3.6); Calibrated: 2/23/2015;
- Sensor-Surface: 2mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2mm
(Mechanical Surface Detection)
- Phantom: ELI v5.0 B; Type: QDOVA002AA; Serial: 1180

Rear/802.11a_Ch 116 w/cover/Area Scan (11x19x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 0.311 W/kg

Rear/802.11a_Ch 116 w/cover/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=2mm
Reference Value = 7.117 V/m; Power Drift = -0.03 dB
Peak SAR (extrapolated) = 0.700 W/kg
SAR(1 g) = 0.172 W/kg; SAR(10 g) = 0.058 W/kg
Maximum value of SAR (measured) = 0.337 W/kg




                      0 dB = 0.337 W/kg = -4.72 dBW/kg




                                                                                                           Plot No. 30


Test Laboratory: UL Verification Services Inc. SAR Lab G                    Date/Time: 4/14/2015 10:29:28 AM

Wi-Fi 5GHz

Frequency: 5745 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 5745 MHz; σ = 5.097 S/m; εr = 35.095; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1433; Calibrated: 3/12/2015
- Probe: EX3DV4 - SN3686; ConvF(4.11, 4.11, 4.11); Calibrated: 2/23/2015;
- Sensor-Surface: 2mm (Mechanical Surface Detection)
- Phantom: SAM A; Type: SAM; Serial: 1831

RHS/Touch_802.11a_Ch 149/Area Scan (11x21x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 0.730 W/kg

RHS/Touch_802.11a_Ch 149/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=2mm
Reference Value = 10.254 V/m; Power Drift = 0.07 dB
Peak SAR (extrapolated) = 1.31 W/kg
SAR(1 g) = 0.327 W/kg; SAR(10 g) = 0.091 W/kg
Maximum value of SAR (measured) = 0.643 W/kg




                      0 dB = 0.643 W/kg = -1.92 dBW/kg




                                                                                                               Plot No. 31


Test Laboratory: UL Verification Services Inc. SAR Lab E                    Date/Time: 4/14/2015 12:02:08 PM

Wi-Fi 5GHz

Frequency: 5745 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                               3
Medium parameters used: f = 5745 MHz; σ = 6.02 S/m; εr = 46.325; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1257; Calibrated: 9/29/2014
- Probe: EX3DV4 - SN3772; ConvF(3.85, 3.85, 3.85); Calibrated: 2/23/2015;
- Sensor-Surface: 2mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2mm
(Mechanical Surface Detection)
- Phantom: ELI v5.0 B; Type: QDOVA002AA; Serial: 1180

Edge 1/802.11a_Ch 149 2/Area Scan (10x10x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 0.439 W/kg

Edge 1/802.11a_Ch 149 2/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=2mm
Reference Value = 8.528 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 0.970 W/kg
SAR(1 g) = 0.258 W/kg; SAR(10 g) = 0.095 W/kg
Maximum value of SAR (measured) = 0.480 W/kg




                      0 dB = 0.480 W/kg = -3.19 dBW/kg




                                                                                                           Plot No. 32



Document Created: 2015-04-20 21:15:23
Document Modified: 2015-04-20 21:15:23