TCoil Test Report

FCC ID: ZNFVS890

Test Report

Download: PDF
FCCID_2014177

                          PCTEST ENGINEERING LABORATORY, INC.
                                             6660-B Dobbin Road, Columbia, MD 21045 USA
                                                 Tel. 410.290.6652 / Fax 410.290.6554
                                                        http://www.pctestlab.com


                                      HEARING AID COMPATIBILITY
Applicant Name:                                                            Date of Testing:
LG Electronics MobileComm U.S.A                                            6/12/2013
1000 Sylvan Avenue                                                         Test Site/Location:
Englewood Cliffs, NJ 07632                                                 PCTEST Lab, Columbia, MD, USA
United States                                                              Test Report Serial No.:
                                                                           0Y1306100972.ZNF


FCC I D:                                          ZNFVS890

APPLI C A NT:                                     LG ELECTRONICS MOBILECOMM U.S.A

Scope of Test:                                    Audio Band Magnetic Testing (T-Coil)
Application Type:                                 Class II Permissive Change
FCC Rule Part(s):                                 CFR § 20.19(b)
HAC Standard:                                     ANSI C63.19-2011
EUT Type:                                         Portable Handset
Model(s):                                         VS890, LGVS890, LG-VS890
Test Device Serial No.:                           Pre-Production Sample [S/N: HAC/T-coil #1]
Class II Permissive Change(s):                    See FCC Change Document
Original Grant Date:                              6/14/2013


C63.19-2011 HAC Category:                         T4 (SIGNAL TO NOISE CATEGORY)

This wireless portable device has been shown to be hearing-aid compatible under the above rated category, specified in ANSI/IEEE
Std. C63.19-2011 and has been tested in accordance with the specified measurement procedures. Test results reported herein
relate only to the item(s) tested. Hearing-Aid Compatibility is based on the assumption that all production units will be designed
electrically identical to the device tested in this report. North American Bands only.

I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and
are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and
vouch for the qualifications of all persons taking them.




                                                                                                                   Reviewed by:
FCC ID: ZNFVS890                                          HAC (T-COIL) TEST REPORT
                                                                                                                   Quality Manager
Filename:                     Test Dates:                   EUT Type:
                                                                                                                   Page 1 of 37
0Y1306100972.ZNF            6/12/2013                       Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                                               REV 7.0U
                                                                                                                          01/18/11


                                   T A B L E                   O F           C O N T E N T S




1.          INTRODUCTION ............................................................................................................................. 3

2.          TEST SITE LOCATION ................................................................................................................... 4

3.          EUT DESCRIPTION ........................................................................................................................ 5

4.          ANSI C63.19-2011 PERFORMANCE CATEGORIES .................................................................... 6

5.          METHOD OF MEASUREMENT ...................................................................................................... 8

6.          FCC 3G MEASUREMENTS .......................................................................................................... 18

7.          TEST SUMMARY .......................................................................................................................... 19

8.          MEASUREMENT UNCERTAINTY ................................................................................................ 23

9.          EQUIPMENT LIST ......................................................................................................................... 24

10.         CALIBRATION CERTIFICATES.................................................................................................... 25

11.         CONCLUSION ............................................................................................................................... 32

12.         REFERENCES .............................................................................................................................. 33

13.         TEST SETUP PHOTOGRAPHS ................................................................................................... 35




                                                                                                                                       Reviewed by:
FCC ID: ZNFVS890                                                   HAC (T-COIL) TEST REPORT
                                                                                                                                       Quality Manager
Filename:                        Test Dates:                          EUT Type:
                                                                                                                                       Page 2 of 37
0Y1306100972.ZNF            6/12/2013                                 Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                                                                    REV 7.0U
                                                                                                                                               01/18/11


1.          INTRODUCTION

On July 10, 2003, the Federal Communications Commission (FCC) adopted new rules requiring wireless
manufacturers and service providers to provide digital wireless phones that are compatible with hearing
aids. The FCC has modified the exemption for wireless phones under the Hearing Aid Compatibility Act of
1998 (HAC Act) in WT Docket 01-309 RM-86581 to extend the benefits of wireless telecommunications to
individuals with hearing disabilities. These benefits encompass business, social and emergency
communications, which increase the value of the wireless network for everyone. An estimated more than
10% of the population in the United States show signs of hearing impairment and of that fraction, almost
80% use hearing aids. Approximately 500 million people worldwide and 30 million people in the United
States suffer from hearing loss.


Compatibility Tests Involved:

The standard calls for wireless communications devices to be measured for:
    RF Electric-field emissions
    T-coil mode, magnetic-signal strength in the audio band
    T-coil mode, magnetic-signal frequency response through the audio band
    T-coil mode, magnetic-signal and noise articulation index

The hearing aid must be measured for:
    RF immunity in microphone mode
    RF immunity in T-coil mode

In the following tests and results, this report includes the evaluation for a wireless communications
device.




                                             Figure 1-1 Hearing Aid in-vitu




1
    FCC Rule & Order, WT Docket 01-309 RM-8658

                                                                                                Reviewed by:
FCC ID: ZNFVS890                                      HAC (T-COIL) TEST REPORT
                                                                                                Quality Manager
Filename:                     Test Dates:              EUT Type:
                                                                                                Page 3 of 37
0Y1306100972.ZNF            6/12/2013                  Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                              REV 7.0U
                                                                                                         01/18/11


2.          TEST SITE LOCATION

I.      Introduction
The map at the right shows the location of the PCTEST
LABORATORY in Columbia, Maryland. It is in proximity to
the FCC Laboratory, the Baltimore-Washington
International (BWI) airport, the city of Baltimore and
Washington, DC (See Figure 2-1).

These measurement tests were conducted at the PCTEST
Engineering Laboratory, Inc. facility in Stonewood
Business Center, Guilford Industrial Park, Columbia,
Maryland. The site address is 7185 Oakland Mills Road,
Columbia, MD 21045. The test site is one of the highest
points in the Columbia area with an elevation of 390 feet
above mean sea level. The site coordinates are 39 10’ 24”
N latitude and 76 49’ 50” W longitude. The facility is 0.4                               Figure 2-1
miles North of the FCC laboratory, and the ambient signal                 Map of the Greater Baltimore and Metropolitan
and ambient signal strength are approximately equal to                               Washington, D.C. area
those of the FCC laboratory.


II.     Test Facility / Accreditations:
Measurements were performed at an independent accredited PCTEST Engineering Lab located in
Columbia, MD, U.S.A.
                           PCTEST Lab is accredited to ISO 17025-2005 by the American Association for
                            Laboratory Accreditation (A2LA) in Specific Absorption Rate (SAR) testing, Hearing-
                            Aid Compatibility (HAC), Long-Term Evolution (LTE), CTIA Test Plans, and wireless
                            testing for FCC and Industry Canada Rules.
                           PCTEST Lab is accredited to ISO 17025 by U.S. National Institute of Standards and
                            Technology (NIST) under the National Voluntary Laboratory Accreditation Program
                            (NVLAP Lab code: 100431-0) in EMC, FCC and Telecommunications.
                           PCTEST facility is an FCC registered (PCTEST Reg. No. 90864) test facility with the
                            site description report on file and has met all the requirements specified in Section
                            2.948 of the FCC Rules and Industry Canada (IC-2451).
                           PCTEST Lab is a recognized U.S. Conformity Assessment Body (CAB) in EMC and
                            R&TTE (n.b. 0982) under the U.S.-EU Mutual Recognition Agreement (MRA).
                           PCTEST TCB is a Telecommunication Certification Body (TCB) accredited to
                            ISO/IEC Guide 65 by the American National Standards Institute (ANSI) in all scopes
                            of FCC Rules and all Industry Canada Standards (RSS).
                           PCTEST facility is an IC registered (IC-2451) test laboratory with the site description
                            on file at Industry Canada.




                                                                                                          Reviewed by:
FCC ID: ZNFVS890                                     HAC (T-COIL) TEST REPORT
                                                                                                          Quality Manager
Filename:                     Test Dates:              EUT Type:
                                                                                                          Page 4 of 37
0Y1306100972.ZNF            6/12/2013                  Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                                      REV 7.0U
                                                                                                                 01/18/11


                 3.           EUT DESCRIPTION




FCC ID:                                                                      ZNFVS890
Applicant:                                                                   LG Electronics MobileComm U.S.A
                                                                             1000 Sylvan Avenue
                                                                             Englewood Cliffs, NJ 07632
                                                                             United States
Model(s):                                                                    VS890, LGVS890, LG-VS890
Serial Number:                                                               HAC/T-coil #1
HW Version:                                                                  Rev.1.0
SW Version:                                                                  VS9800CD
Antenna:                                                                     Internal Antenna
HAC Test Configurations:                                                     Cell. CDMA, 1013, 384, 777, BT Off, WLAN Off, LTE Off
                                                                             PCS CDMA, 25, 600, 1175, BT Off, WLAN Off, LTE Off
EUT Type:                                                                    Portable Handset

                       Band          Type                                                               Concurrent HAC Tested     Voice over Digital Transport                      Additional GSM
 Air‐Interface                                    HAC Tested          Simultaneous But Not Tested                                                                WIFI Low Power
                      (MHz)        Transport                                                                or not tested               OTT Capability                             Power Reduction

                       835                                                                                                1
                                       VO             Yes                 Yes: LTE, WIFI or BT               Not tested                       N/A
    CDMA               1900                                                                                                                                            N/A                N/A
                      EVDO             DT            N/A                     Yes: WIFI or BT                     N/A                          Yes
                                                        2                                                                 2
     LTE               700             VD             No                 Yes: CDMA, WIFI or BT               Not tested                       Yes                      N/A                N/A
     WIFI              2450            DT             No                   Yes: CDMA or LTE                     N/A                           Yes                      N/A                N/A
      BT               2450             DT              No                 Yes: CDMA or LTE                       N/A                         N/A                        N/A               N/A
                  Type Transport                                                                       1. Non‐concurrent mode was found to be the Worst Case mode
                  VO = Voice Only                                                                      2. LTE VoLTE CMRS Services were not be tested for M and T rating per exemption permitted by
                  DT = Digital Data ‐ Not intended for CMRS Service                                    20.19 rule change (DA 12‐550) which established a one year grace period from Aug 18 2012 to
                  VD = CMRS and Data Transport                                                         Aug 18 2013

                                                                          Table 3-1: ZNFVS890 Air Interfaces




                                                                                                                                                                    Reviewed by:
                 FCC ID: ZNFVS890                                                           HAC (T-COIL) TEST REPORT
                                                                                                                                                                    Quality Manager
                 Filename:                          Test Dates:                                  EUT Type:
                                                                                                                                                                    Page 5 of 37
                 0Y1306100972.ZNF            6/12/2013                                           Portable Handset
                 © 2013 PCTEST Engineering Laboratory, Inc.                                                                                                                  REV 7.0U
                                                                                                                                                                              01/18/11


4.          ANSI C63.19-2011 PERFORMANCE CATEGORIES

I.      MAGNETIC COUPLING

Axial and Radial Field Intensity

     All orientations of the magnetic field, in the axial and radial position along the measurement plane
     shall be ≥ -18 dB(A/m) at 1 kHz in a 1/3 octave band filter per §8.3.1.
Frequency Response

     The frequency response of the axial component of the magnetic field shall follow the response curve
     specified in EIA RS-504-1983, over the frequency range 300 Hz – 3000 Hz per §8.3.2.

                                                                            MAGNETIC FIELD STRENGTH RELATIVE TO 1000 Hz
                                                                  20
                           dB Relative to Value at 1




                                                                                              -4 dB/Oct.
                                                                  10
                                                                                                                               +2 dB

                                                                                    -2 dB
                                     kHz




                                                                      0
                                                                                                                                              -6 d B/Oct.


                                                                  -10
                                                                                  6 dB/Oct.



                                                                  -20
                                                                     300                      500              1000              2000                       3000
                                                                                                           FREQUENCY (Hz)

                                                    Figure 4-1
                    Magnetic field frequency response for Wireless Devices with an axial field
                                             ≤ -15 dB (A/m) at 1 kHz

                                                                                 M AGNETIC FIELD S TRENGTH RELATIVE TO 1 0 0 0 Hz
                                                                20

                                                                                           -4 d B/Oct.
                                dB Relative to Value at 1 kHz




                                                                10
                                                                                                                                +2 d B


                                                                                  -2 d B
                                                                 0
                                                                                                                                           -7 d B/Oct.


                                                                -10
                                                                               6 d B /Oct.
                                                                                                                                       -1 2
                                                                                                                                       d B /Oct.
                                                                -20
                                                                      300                    500                 1000           2000                        3000
                                                                                                            FREQUENCY (Hz)

                                                 Figure 4-2
            Magnetic Field frequency response for wireless devices with an axial field that exceeds
                                           -15 dB(A/m) at 1 kHz
                                                                                                                                                                   Reviewed by:
FCC ID: ZNFVS890                                                                                    HAC (T-COIL) TEST REPORT
                                                                                                                                                                   Quality Manager
Filename:                                    Test Dates:                                             EUT Type:
                                                                                                                                                                   Page 6 of 37
0Y1306100972.ZNF            6/12/2013                                                                Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                                                                                               REV 7.0U
                                                                                                                                                                          01/18/11


Signal Quality

     The table below provides the signal quality requirement for the intended audio magnetic signal from a
     wireless device. Only the RF immunity of the hearing aid is measured in T-coil mode. It is assumed
     that a hearing aid can have no immunity to an interference signal in the audio band, which is the
     intended reception band for this mode. The only criterion that can be measured is the RF immunity in
     T-coil mode. This is measured using the same procedure as the audio coupling mode at the same
     levels.

     The signal quality of the axial and radial components of the magnetic field was used to determine the
     T-coil mode category.


                                                         Telephone RF Parameters
                                     Category
                                                        Wireless Device Signal Quality
                                                    [(Signal + Noise)-to-noise ratio in dB]
                                            T1                    0 to 10 dB
                                            T2                   10 to 20 dB
                                            T3                    20 to 30 dB
                                            T4                      > 30 dB

                                                           Table 4-1
                                                 Magnetic Coupling Parameters




                                                                                              Reviewed by:
FCC ID: ZNFVS890                                          HAC (T-COIL) TEST REPORT
                                                                                              Quality Manager
Filename:                     Test Dates:                   EUT Type:
                                                                                              Page 7 of 37
0Y1306100972.ZNF            6/12/2013                       Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                          REV 7.0U
                                                                                                     01/18/11


5.          METHOD OF MEASUREMENT


I.      Test Setup
     The equipment was connected as shown in an acoustic/RF hemi-anechoic chamber:




                                    Figure 5-1 Validation Setup with Helmholtz Coil




                                             Figure 5-2 T-Coil Test Setup




                                                                                      Reviewed by:
FCC ID: ZNFVS890                                     HAC (T-COIL) TEST REPORT
                                                                                      Quality Manager
Filename:                     Test Dates:              EUT Type:
                                                                                      Page 8 of 37
0Y1306100972.ZNF            6/12/2013                  Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                  REV 7.0U
                                                                                             01/18/11


II.     Scanning Mechanism

Manufacturer:                               TEM
Accuracy:                                   ± 0.83 cm/meter
Minimum Step Size:                          0.1 mm
Maximum speed                               6.1 cm/sec
Line Voltage:                               115 VAC
Line Frequency:                             60 Hz
Material Composite:                         Delrin (Acetal)
Data Control:                               Parallel Port
                                                                                                     Figure 5-3
Dynamic Range (X-Y-Z):                      45 x 31.75 x 47 cm                                  RF Near-Field Scanner

Dimensions:                                 36” x 25” x 38”
Operating Area:                             36” x 49” x 55”
Reflections:                                < -20 dB (in anechoic chamber)



III.    ITU-T P.50 Artificial Voice
Manufacturer:                      ITU-T
Active Frequency
                                   100 Hz – 8 kHz
Range:
Stimulus Type:                     Male and Female, no spaces
Single Sample Duration:            20.96 seconds
Activity Level:                    100%


                                                                                                    Figure 5-4
                                                                                         Spectral Characteristic of full P.50




                                                         Figure 5-5
                                              Temporal Characteristic of full P.50




                                                                                                                  Reviewed by:
FCC ID: ZNFVS890                                              HAC (T-COIL) TEST REPORT
                                                                                                                  Quality Manager
Filename:                     Test Dates:                      EUT Type:
                                                                                                                  Page 9 of 37
0Y1306100972.ZNF            6/12/2013                          Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                                              REV 7.0U
                                                                                                                         01/18/11


 ABM1 Measurement Block Diagram:

                  Raw Probe
                 Measurement
                    (mV)
                                                                 T-Coil Probe                            1 kHz bin,
 1kHz through                   40                                                      40 dB
                                                              Sensitivity Factor                         1/3-octave                                ABM1
     WD                         dB                                                  pre-gain factor
                                                              (-59.09 dBV/A/m)                              filter




 ABM2 Measurement Block Diagram:
                  Raw Probe
                 Measurement
                    (mV)
                                                T-Coil Probe            40 dB
                               40                                                       Half-Band           IEC179          100Hz-10kHz
      noise                                  Sensitivity Factor        pre-gain                                                                    ABM2
                               dB                                                    Integrator curve   A-weighting curve    Power Sum
                                             (-59.09 dBV/A/m)           factor



                                   Figure 5-6 Magnetic Measurement Processing Steps

IV.           Test Procedure

       1. Ambient Noise Check per C63.19 §7.3.1
             a. Ambient interference was monitored using a Real-Time Analyzer between 100-10,000 Hz
                 with 1/3 octave filtering.
             b. “A-weighting” and Half-Band Integration was applied to the measurements.
             c. Since this measurement was measured in the same method as ABM2 measurements,
                 this level was verified to be more than 10 dB below the lowest measurement signal
                 (which is the highest ABM2 measurement for a T4 WD). Therefore the maximum noise
                 level for a T4 WD with an ABM1 = -18 dBA/m is:
                                            -18 - 30 - 10 = -58 dBA/m

       2. Measurement System Validation (See Figure 5-1)
             a. The measurement system including the probe, pre-amplifier and acquisition system were
                validated as an entire system to ensure the reliability of test measurements.

                  b. ABM1 Validation
                     The magnetic field at the center of the Helmholtz coil is given by the equation (per
                     C63.19 Annex D.10.1):
                                                                                         V
                                                                                       N( )
                                                                             NI           R
                                                                      Hc           
                                                                                  3
                                                                           r 1.25     r 1.25 3
                                Where Hc = magnetic field strength in amperes per meter
                                      N = number of turns per coil

                        For the Helmholtz Coil, N=20; r=0.13m; R=10.193Ω and using V=29mV:

                                                         0.029
                                                  20  (       )
                                             Hc        10.193  0.31623 A / m  10dB( A / m)
                                                  0.13  1.253
                        Therefore a pure tone of 1kHz was applied into the coils such that 29 mV was observed
                        across the 10 Ω resistor. The voltmeter used for measurement was verified to be capable
                        of measurements in the audio band range. This theoretically generates an expected field
                        of -10 dB(A/m) in the center of the Helmholtz coil which was used to validate the probe
                        measurement at -10 dB(A/m). This was verified to be within ± 0.5 dB of the -10 dB(A/m)
                        value (see Page 22).
                                                                                                                                          Reviewed by:
FCC ID: ZNFVS890                                                     HAC (T-COIL) TEST REPORT
                                                                                                                                          Quality Manager
Filename:                      Test Dates:                              EUT Type:
                                                                                                                                          Page 10 of 37
0Y1306100972.ZNF            6/12/2013                                   Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                                                                      REV 7.0U
                                                                                                                                                 01/18/11


                c.   Frequency Response Validation

                     The frequency response through the Helmholtz Coil was verified to be within 0.5 dB
                     relative to 1 kHz, between 300 – 3000 Hz using the ITU-P.50 artificial speech signal as
                     shown below:




                                       Figure 5-7 Frequency Response Validation

                d. ABM2 Measurement Validation

                     WD noise measurements are filtered with A-weighting and Half-Band Integration over a
                     frequency range of 100Hz – 10kHz to process ABM2 measurements. Below is the
                     verification of the system processing A-weighting and Half-Band integration between
                     system input to output within 0.5 dB of the theoretical result:


                                                               Table 5-1
                                                 ABM2 Frequency Response Validation
                                                       HBI, A -        HBI, A -
                                             f (Hz)   Measured      Theoretical dB Var.
                                                     (dB re 1kHz) (dB re 1kHz)
                                              100      -16.180         -16.170   -0.010
                                              125      -13.257         -13.250   -0.007
                                              160      -10.347         -10.340   -0.007
                                              200       -8.017          -8.010   -0.007
                                              250       -5.925          -5.920   -0.005
                                              315       -4.045          -4.040   -0.005
                                              400       -2.405          -2.400   -0.005
                                              500       -1.212          -1.210   -0.002
                                              630       -0.349          -0.350   0.001
                                              800        0.071           0.070   0.001
                                             1000       0.000           0.000    0.000
                                             1250       -0.503          -0.500   -0.003
                                             1600       -1.513          -1.510   -0.003
                                             2000       -2.778          -2.780   0.002
                                             2500       -4.316          -4.320   0.004
                                             3150       -6.166          -6.170   0.004
                                             4000       -8.322          -8.330   0.008
                                             5000      -10.573         -10.590   0.017
                                             6300      -13.178         -13.200   0.022
                                             8000      -16.241         -16.270   0.029
                                             10000     -19.495         -19.520   0.025




                                                                                                  Reviewed by:
FCC ID: ZNFVS890                                     HAC (T-COIL) TEST REPORT
                                                                                                  Quality Manager
Filename:                     Test Dates:             EUT Type:
                                                                                                  Page 11 of 37
0Y1306100972.ZNF            6/12/2013                 Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                              REV 7.0U
                                                                                                         01/18/11


                                                                             ABM2 Frequency Response Validation (LISTEN)

                                                         10




                                                          0
                                                           100                                  1000                                            10000



                                                         -10




                                  dBV, A weighted, HBI
                                                         -20




                                                         -30

                                                                                                              HBI, A - Measured
                                                                                                              HBI, A - Theoretical

                                                         -40




                                                         -50
                                                                                            Frequency (Hz)


                                                                                Figure 5-8
                                                                    ABM2 Frequency Response Validation

                     The ABM2 result is a power sum from 100 Hz to 10 kHz with half-band integration and A-
                     weighting. To verify the power sum measurement, a power sum over the full band was
                     measured and verified to track with the source level (See Figure 5-9). Therefore the
                     setup in this step was used to verify the power sum post-processing for ABM2
                     measurements. See below block diagram:




                                                                          Figure 5-9
                                                                 ABM2 Validation Block Diagram

                     The power summed output results for a known input were compared to the multi-meter
                     results to verify any deviation in the post-processing implemented with the power-sum.

                                                                                  Table 5-2
                                                                           ABM2 Power Sum Validation
                                                                  WN Input      Power Sum              Multimeter-Full
                                                                                                                                     Dev (dB)
                                                                   (dBV)          (dBV)                     (dBV)

                                                                     -60           -60.36                    -60.2                     0.16
                                                                     -50           -50.19                    -50.13                    0.06
                                                                     -40           -40.14                    -40.03                    0.11
                                                                     -30           -30.13                    -30.01                    0.12
                                                                     -20           -20.12                     -20                      0.12
                                                                     -10           -10.14                     -10                      0.14


                                                                                                                                                        Reviewed by:
FCC ID: ZNFVS890                                                             HAC (T-COIL) TEST REPORT
                                                                                                                                                        Quality Manager
Filename:                     Test Dates:                                     EUT Type:
                                                                                                                                                        Page 12 of 37
0Y1306100972.ZNF            6/12/2013                                         Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                                                                                    REV 7.0U
                                                                                                                                                               01/18/11


                                                                                                     ABM2 Power Sum Validation (LISTEN)

                                                                    -10




                                                                    -20




                                                                    -30




                                             Measured Level (dBV)
                                                                    -40

                                                                                                                                             Power Sum (dBV)
                                                                                                                                             Multimeter-Full (dBV)


                                                                    -50




                                                                    -60




                                                                    -70
                                                                          -60   -55    -50     -45        -40        -35         -30   -25       -20             -15       -10
                                                                                                                WN Input (dBV)



                                                                                              Figure 5-10
                                                                                       ABM2 Power Sum Validation

     3. Measurement Test Setup
           a. Fine scan above the WD (TEM)
                   i. A multitone signal was applied to the handset such that the phone acoustic
                      output was stable within 1dB over the probe settling time and with the acoustic
                      output level at the C63.19 specified levels (below). The measurement step size
                      was in 2 mm increments at a distance of 10 mm between the surface of the
                      wireless device as shown below:




                                                                                                 Figure 5-11
                                                                                             Measurement Distance
.
                           ii. After scanning, the planar field maximum point was determined. The position of
                               the probe was moved to this location to setup the test using the sound check
                               system.
                          iii. These steps were repeated for all T-coil orientations (axial and radial) per Figure
                               5-16 after a T-coil orientation was fully measured with the SoundCheck system.

                b. Speech Signal Setup to Base Station Simulator
                       i. C63.19 Table 7-1 states audio reference input levels for various technologies:

                                                                                                                                                                       Input Level
                                                                            Standard                              Technology
                                                                                                                                                                         (dBm0)
                                             TIA/EIA/IS-2000                                             CDMA                                                              -18
                                             J-STD-007                                                   GSM (217)                                                         -16
                                             T1/T1P1/3GPP                                                UMTS (WCDMA)                                                      -16
                                             iDENTM                                                      TDMA (22 and 11 Hz)                                               -18



                                                                                                                                                                                     Reviewed by:
FCC ID: ZNFVS890                                                                         HAC (T-COIL) TEST REPORT
                                                                                                                                                                                     Quality Manager
Filename:                     Test Dates:                                                    EUT Type:
                                                                                                                                                                                     Page 13 of 37
0Y1306100972.ZNF            6/12/2013                                                        Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                                                                                                                 REV 7.0U
                                                                                                                                                                                            01/18/11


                                The CMU200 audio levels were determined using base station simulator
                                manufacturer calibration procedures resulting in the below corresponding
                                voltages relative to handset test point level (in dBm0):

                                                                      Table 5-3
                                                         CMU200 Voltage Input Levels for Audio

                                             dBm0 Ref.          Input Voltage           Notes

                                                                                        From CDMA2K "DECODER CAL".
                                             3.14 dBm0     1052.0 mV          0.4 dBV   (What is needed through Encoder
                                                                                        for FS)
                                              -18 dBm0     92.260 mV      -20.7 dBV     For 8k Enhanced (Low)




                c. Real-Time Analyzer (RTA)
                       i. The Real-Time Analyzer was configured to analyze measurements using 1/3
                          Octave band weighted filtering.
                d. WD Radio Configuration Selection
                       i. The device was chosen to be tested in the worst-case ABM2 condition under
                          RC1/SO3 (EVRC) (see below):




                                                      Figure 5-12
                                             Vocoder Analysis for ABM Noise

     4. Signal Quality Data Analysis
            a. Narrow-band Magnetic Intensity
                      i. The standard specifies a 1kHz 1/3 octave band minimum field intensity for a sine
                         tone. The ABM1 measurements were evaluated at 1kHz with 1/3 octave band
                         filtering over an averaged period of 10 seconds.
            b. Frequency Response
                      i. The appropriate frequency response curve was measured to curves in Figure 4-1
                         or Figure 4-2 between 300 – 3000 Hz using digital linear averaging (limit lines
                         chosen according to measurement found in step 4a.) A linear average over 3x
                         the length of the artificial voice signal (3x sampling) was performed. A 10 second
                         delay was configured in the measurement process of the stimulus to ensure
                         handset vocoder latency effects and echo cancellation devices (if any) were
                         appropriately stabilized during measurements.
                     ii. The appropriate post-processing was applied according to the system processing
                         chain illustrated in Figure 5-13. All R10 frequencies were plotted with respect to
                         0dB at 1 kHz value and aligned with respect to the EIA-504 mask.


                                                                                                                     Reviewed by:
FCC ID: ZNFVS890                                          HAC (T-COIL) TEST REPORT
                                                                                                                     Quality Manager
Filename:                     Test Dates:                  EUT Type:
                                                                                                                     Page 14 of 37
0Y1306100972.ZNF            6/12/2013                      Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                                                 REV 7.0U
                                                                                                                            01/18/11


                                   Figure 5-13 Frequency Response Block Diagram

                          iii. The margin is represented by the closest measured data point on the curve to
                               the EIA-504 limit lines, in dB.

                c.   Signal Quality Index
                           i. Ensuring the WD was at maximum RF power, maximum volume, backlight on,
                              display on, maximum contrast setting, keypad lights on (when possible) with no
                              audio signal through the vocoder, the WD was measured over at least 100 Hz –
                              10,000 Hz, maximized over 5 seconds with a 50ms sample time for the ABM2
                              measurement (5 second time period is used in noise measurements under
                              standards such as IEEE 269, etc.)
                          ii. After applying half-band integration and A-weighting to the result, a power sum
                              was applied over each 1/3 octave bandwidth frequency for an ABM2 value
                         iii. This result was subtracted from the ABM1 result in step a, to obtain the Signal
                              Quality.

V.      Test Setup

                                                                                                           Integrator



                                                                                                       1/3 Octave Bandpass
                                                                                                             Filter
                                                                   Probe Coil
                                                                 (Shown in Axial Position)

                                                                                                       RMS Voltmeter



                                                          Wireless Device                                  Graphics
                                                                                                           Recorder



                                                                              Reference
                                                                                                            Signal
                                                                             Base Station
                                             Antenna replaced                                               Source
                                                                              Simulator
                                             with Coaxial Connection




                                                                                                         Controller

                                                         Figure 5-14
                                                Audio Magnetic Field Test Setup

VI.     Deviation from C63.19 Test Procedure

None.




                                                                                                                             Reviewed by:
FCC ID: ZNFVS890                                                            HAC (T-COIL) TEST REPORT
                                                                                                                             Quality Manager
Filename:                     Test Dates:                                      EUT Type:
                                                                                                                             Page 15 of 37
0Y1306100972.ZNF            6/12/2013                                          Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                                                         REV 7.0U
                                                                                                                                    01/18/11


VII. Air Interface Technologies Tested

WIFI and all 3G packet services were not tested for this device since they are considered ‘Over-the-Top’
applications and are not within the current definition of a managed CMRS service.

LTE VoLTE CMRS Services could not be tested for M and T rating because CMRS LTE VoLTE T-coil test
instrumentation was not available. This exception is permitted by 20.19 rule change (DA 12-550) effective
August 18, 2012 which established a one year grace period from Aug 18 2012 to Aug 18 2013 for LTE
VoLTE CMRS Services.

VIII. Wireless Device Channels and Frequencies

The frequencies listed in the table below are those that lie in the center of the bands used for cellular
telephony. Low, middle and high channels were tested in each band for FCC compliance evaluation to
ensure the maximum emission is captured across the entire band.

To facilitate setting of a base station simulator for ABM measurements, specific band plan channel
numbers are listed that may be used in lieu of the band center frequencies.

                                                        Table 5-4
                                             Center Channels and Frequencies
                                         Test frequencies & associated channels
                                                                                    Frequency
                                               Channel
                                                                                      (MHz)
                                                      Cellular 850
                                             384 (CDMA)                              836.52
                                                         PCS 1900
                                             600 (CDMA)                               1880

IX.     RF Emission Effect on T-coil Measurements




                                          Figure 5-15
    High power RF Emissions Effect with HAC Dipole on the T-coil Probe System 10mm between
                             dipole maximum and magnetic probe




                                                                                                Reviewed by:
FCC ID: ZNFVS890                                         HAC (T-COIL) TEST REPORT
                                                                                                Quality Manager
Filename:                     Test Dates:                 EUT Type:
                                                                                                Page 16 of 37
0Y1306100972.ZNF            6/12/2013                     Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                            REV 7.0U
                                                                                                       01/18/11


X.      Test Flow
The flow diagram below was followed (From C63.19):

                                      Confirm calibration of test
                                       equipment
                                      Configure and validate test
                                        setup
                                      Establish WD reference level
                                      Scan for measurement locations




                                     Position and orient probe
                                     Measure desired audio band
                                       Signal strength
                                     Measure undesired audio
                                       Band signal strength



                                      Calculate signal strength
                                      Calculate signal quality
                                      Measure frequency response




                                                Both locations
                                                 measured?
                                                                           N

                                                          Y



                                                Intensity and
                                             Frequency response             N
                                                 compliant?




                                                          Y


                                       Determine and record signal                    Done
                                            Quality category




                                                       Figure 5-16
                                             C63.19 T-Coil Signal Test Process



                                                                                             Reviewed by:
FCC ID: ZNFVS890                                           HAC (T-COIL) TEST REPORT
                                                                                             Quality Manager
Filename:                     Test Dates:                     EUT Type:
                                                                                             Page 17 of 37
0Y1306100972.ZNF            6/12/2013                         Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                         REV 7.0U
                                                                                                    01/18/11


6.          FCC 3G MEASUREMENTS

Radio Configuration 1, Service Option 3 (thick, green data curve) was used for the testing as the worst-
case configuration for the handset due to vocoder gating from the EVRC logic. See below plot for ABM
noise comparison between operational field service options and radio configurations for a CDMA2000
handset:




                                                       Figure 6-1
                                             CDMA Audio Band Magnetic Noise

I.       ABM Measurements
                                                    Table 6-1
                                       FCC 3G ABM Measurements for ZNFVS890
                       ABM2 Pre-Test (dBA/m), A, HBI
                        RC1/SO3              RC3/SO3    RC4/SO3            Orientation          Channel

                           -33.07             -52.25      -52.12                 Radial              777

                       ABM1 Pre-Test (dBA/m)


                        RC1/SO3              RC3/SO3    RC4/SO3            Orientation          Channel

                           4.040              4.010       4.090                  Radial              777

           Mute on; Backlight off; Max Volume, Max Contrast
           Power Control Bits = "All Up"


                                              40                Probe                      40 dB
            WD noise                                           Sensitivity                pre-gain         curve
                                              dB
                                                              (-59.09 dBV/A/m)             factor


                                                 Figure 6-2
                            Audio Band Magnetic Curve Measurement Block Diagram




                                                                                                             Reviewed by:
FCC ID: ZNFVS890                                       HAC (T-COIL) TEST REPORT
                                                                                                             Quality Manager
Filename:                     Test Dates:               EUT Type:
                                                                                                             Page 18 of 37
0Y1306100972.ZNF            6/12/2013                   Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                                         REV 7.0U
                                                                                                                    01/18/11


7.          TEST SUMMARY

I.      T-Coil Test Summary

                                                             Table 7-1
                                                    Table of Results for CDMA
                                                                                         Minimum
            C63.19 Sec.      Mode           Band               Test Description                      Measured    Verdict
                                                                                          Limit*
                                                                                          dBA/m       dBA/m     PASS/FAIL
               8.3.1                                Intensity, Axial                           -18     11.7       PASS
               8.3.1                                Intensity, Radial                          -18     4.0        PASS
               8.3.4        CDMA        Cellular Signal-to-Noise/Noise, Axial                  20      47.2       PASS
               8.3.4                                Signal-to-Noise/Noise, Radial              20      37.7       PASS
               8.3.2                                Frequency Response, Axial                  0       0.8        PASS


               8.3.1                                Intensity, Axial                           -18     11.6       PASS
               8.3.1                                Intensity, Radial                          -18     3.5        PASS
               8.3.4        CDMA             PCS    Signal-to-Noise/Noise, Axial               20      49.2       PASS
               8.3.4                                Signal-to-Noise/Noise, Radial              20      39.7       PASS
               8.3.2                                Frequency Response, Axial                  0       0.9        PASS


Note: The above summary table represents the worst-case numerical values according to configurations
in Table 7-3.

                                                            Table 7-2
                                                   Consolidated Tabled Results

                                                   Volume                     Cellular                        PCS
                                                   Setting
                                                                         Axial      Radial           Axial          Radial
              Freq. Response Margin                                     PASS             N/A         PASS            N/A
            Magnetic Intensity Verdict Maximum                          PASS        PASS             PASS           PASS
                       FCC SNR Verdict                                  PASS        PASS             PASS           PASS

Note: Result shown is for T-coil category only.




                                                                                                                     Reviewed by:
FCC ID: ZNFVS890                                              HAC (T-COIL) TEST REPORT
                                                                                                                     Quality Manager
Filename:                     Test Dates:                       EUT Type:
                                                                                                                     Page 19 of 37
0Y1306100972.ZNF            6/12/2013                           Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                                                  REV 7.0U
                                                                                                                             01/18/11


II.        Raw Handset Data

                                                       Table 7-3
                                               Raw Data Results for CDMA
                                                                                 Cellular Band
                                             Volume
                                                                     Axial                        Radial
                                                            1013     384         777      1013     384        777
                            ABM1, dBA/m                    11.66    11.91       11.95     4.02     4.36       4.17
                            ABM2, dBA/m                    -35.87   -36.34      -35.22   -34.14   -34.68     -33.56
                   Freq. Response Margin
                                                           0.82      0.86       0.93      N/A       N/A       N/A
                                    (dB) Maximum
                              S+N/N (dB)                   47.53    48.25       47.17    38.16     39.04     37.73
                    S+N/N per orientation
                                                                    47.17                         37.73
                                     (dB)

                                                                                  PCS Band
                                             Volume
                                                                     Axial                        Radial
                                                             25      600         1175      25      600        1175
                            ABM1, dBA/m                    11.58    11.67       11.67     3.54     3.94       3.80
                            ABM2, dBA/m                    -37.64   -38.21      -37.60   -36.14   -36.78     -36.10
                   Freq. Response Margin
                                                           0.98      0.93       0.99      N/A       N/A       N/A
                                    (dB) Maximum
                              S+N/N (dB)                   49.22    49.88       49.27    39.68     40.72     39.90
                    S+N/N per orientation
                                                                    49.22                         39.68
                                     (dB)
                                              [x,y] from
                 T-coil Coordinates (cm)                            2.6, 2.6                      2.6, 3.2
                                             bottom left




Notes:

      1.    Power Configuration: Power Control Bits = "All Up".
      2.    Phone Condition: Mute on; Backlight off; Max Volume, Max Contrast.
      3.    Vocoder Configuration: RC1/SO3 (EVRC).
      4.    'Radial' orientation refers to radial transverse.




                                                                                                                      Reviewed by:
FCC ID: ZNFVS890                                           HAC (T-COIL) TEST REPORT
                                                                                                                      Quality Manager
Filename:                     Test Dates:                    EUT Type:
                                                                                                                      Page 20 of 37
0Y1306100972.ZNF            6/12/2013                        Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                                                  REV 7.0U
                                                                                                                             01/18/11


III.    Frequency Response Graph




                                                                                                                Figure 7-1
                                                                                                       Axial Frequency Response

Note: This frequency response represents the worst-case ABM2 test configuration according Table 7-3.

IV.     1 kHz Vocoder Application Check
                                                                        1kHz Tone Pass-through Check                                                                                    1kHz Tone Pass-through for UMTS

                                                20                                                                                                              20



                                                10                                                                                                              10



                                                 0                                                                                                               0
                      Field Intensity (dBA/m)




                                                                                                                                      Field Intensity (dBA/m)




                                                -10                                                                                                             -10



                                                -20                                                                                                             -20



                                                -30                                                                                                             -30



                                                -40                                                                                                             -40



                                                -50                                                                                                             -50



                                                -60                                                                                                             -60
                                                      -70   -60   -50       -40             -30             -20   -10    0       10                                   -70   -60   -50       -40             -30             -20   -10   0   10
                                                                                  1kHz input level (dBm0)                                                                                         1kHz input level (dBm0)




This model was verified to be within the linear region for ABM1 measurements at -18 dBm0. This
measurement was taken in the axial configuration above the maximum location.

V.      Undesirable Audio Magnetic Band Plot (ABM2)




                                                Figure 7-2
                                      Worst-case ABM2 Plot for WD
Note: This plot represents the data from the location/configuration resulting in the highest ABM2 result
shown in Table 7-3.




                                                                                                                                                                                                                                                 Reviewed by:
FCC ID: ZNFVS890                                                                                                        HAC (T-COIL) TEST REPORT
                                                                                                                                                                                                                                                 Quality Manager
Filename:                                                   Test Dates:                                                      EUT Type:
                                                                                                                                                                                                                                                 Page 21 of 37
0Y1306100972.ZNF            6/12/2013                                                                                        Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                                                                                                                                                                             REV 7.0U
                                                                                                                                                                                                                                                        01/18/11


VI.     T-Coil Validation Test Results




                                                     Figure 7-3
                                 Helmholtz Coil Validation for Frequency Response



                                                       Table 7-4
                                       Helmholtz Coil Validation Table of Results

                         Item                             Target                 Result   Verdict

 Signal Validation
 Frequency Response, from limits                        0 ± 0.5 dB                0.20    PASS
 Magnetic Intensity, -10 dBA/m                         -10 ± 0.5 dB              -9.831   PASS
 Noise Validation

 Axial Environmental Noise                            < - 58 dBA/m               -60.21   PASS

 Radial Environmental Noise                           < - 58 dBA/m               -60.98   PASS




                                                                                            Reviewed by:
FCC ID: ZNFVS890                                      HAC (T-COIL) TEST REPORT
                                                                                            Quality Manager
Filename:                     Test Dates:              EUT Type:
                                                                                            Page 22 of 37
0Y1306100972.ZNF            6/12/2013                  Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                        REV 7.0U
                                                                                                   01/18/11


8.          MEASUREMENT UNCERTAINTY

                                                         Table 8-1
                                                Uncertainty Estimation Table
                                                                                                                      Standard
                                     Data +/- Data +/-                          Probability               Standard
             Contribution                                    Data Type                         Divisor               Uncertainty
                                       %        dB                              distribution             uncertainty
                                                                                                                        (dB)
 ABM Noise                            7.0%       0.29        Std. Dev.          Normal k=1      1.00        7.0%
 RF Reflections                       4.7%       0.20       Specification       Rectangular     1.73        2.7%
 Reference Signal Level              12.2%       0.50       Specification       Rectangular     1.73        7.0%
 Positioning Accuracy                10.0%       0.41       Uncertainty         Rectangular     1.73        5.8%
 Probe Coil Sensitivity              12.2%       0.50       Specification       Rectangular     1.73        7.0%
 Probe Linearity                      2.4%       0.10        Std. Dev.          Normal k=1      1.00        2.4%
 Cable Loss                           2.8%       0.12       Specification       Rectangular     1.73        1.6%
 Frequency Analyzer                   5.0%       0.21       Specification       Rectangular     1.73        2.9%
 System Repeatability                 5.0%       0.21        Std. Dev.          Normal k=1      1.00        5.0%
 WD Repeatability                     9.0%       0.37        Std. Dev.          Normal k=1      1.00        9.0%
 Positioner Accuracy                 1.0%        0.04       Specification       Rectangular     1.73        0.6%

 Combined standard uncertainty, uc (k=1)                                                                   17.7%          0.71
 Expanded uncertainty (k=2), 95% confidence level                                                          35.3%          1.31
             Notes:
            1. Test equipments are calibrated according to techniques outlined in NIS81, NIS3003 and NIST Tech Note 1297.
            2. All equipments have traceability according to NIST. Measurement Uncertainties are defined in further detail in
                NIS 81 and NIST Tech Note 1297 and UKAS M3003.

Measurement uncertainty reflects the quality and accuracy of a measured result as compared to the true
value. Such statements are generally required when stating results of measurements so that it is clear to
the intended audience that the results may differ when reproduced by different facilities. Measurement
results vary due to the measurement uncertainty of the instrumentation, measurement technique, and test
engineer. Most uncertainties are calculated using the tolerances of the instrumentation used in the
measurement, the measurement setup variability, and the technique used in performing the test. While
not generally included, the variability of the equipment under test also figures into the overall
measurement uncertainty. Another component of the overall uncertainty is based on the variability of
repeated measurements (so-called Type A uncertainty). This may mean that the Hearing Aid
compatibility tests may have to be repeated by taking down the test setup and resetting it up so that there
are a statistically significant number of repeat measurements to identify the measurement uncertainty. By
combining the repeat measurement results with that of the instrumentation chain using the technique
contained in NIS 81 and NIS 3003, the overall measurement uncertainty was estimated.




                                                                                                                     Reviewed by:
FCC ID: ZNFVS890                                           HAC (T-COIL) TEST REPORT
                                                                                                                     Quality Manager
Filename:                     Test Dates:                    EUT Type:
                                                                                                                     Page 23 of 37
0Y1306100972.ZNF            6/12/2013                        Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                                                 REV 7.0U
                                                                                                                            01/18/11


9.          EQUIPMENT LIST

                                                            Table 9-1
                                                          Equipment List
   Manufacturer           Model                         Description                Cal Date     Cal Interval   Cal Due      Serial Number
      Agilent            E4407B                   ESA Spectrum Analyzer             4/16/2013     Annual       4/16/2014    US39210313
 Control Company        36934-158               Wall-Mounted Thermometer             1/4/2012    Biennial       1/4/2014     122014497
   Gigatronics            80701A                (0.05-18GHz) Power Sensor          10/10/2012     Annual       10/10/2013     1833460
   Gigatronics             8651A                   Universal Power Meter           10/10/2012     Annual       10/10/2013     8650319
      Listen           SoundCheck                Acoustic Analyzer System           10/4/2012     Annual        10/4/2013     979921
      Listen          SoundConnect               Microphone Power Supply            4/22/2013     Annual       4/22/2014      PS2612
         NI                 4474                    Data Acquisition Card              N/A          N/A            N/A          N/A
 Rohde & Schwarz         CMU200                    Base Station Simulator           5/3/2013        N/A         5/3/2014    836371/0079
    Seekonk               NC-100                   Torque Wrench (8" lb)           11/29/2011    Triennial     11/29/2014      21053
       TEM          Axial T-Coil Probe               Axial T-Coil Probe             7/12/2012     Annual        7/12/2013    TEM-1122
       TEM          Radial T-Coil Probe              Radial T-Coil Probe            7/12/2012     Annual       7/12/2013     TEM-1128
       TEM                C63.19                       Helmholtz Coil               4/5/2013     Biennial       4/5/2015        925
       TEM                                   HAC System Controller with Software       N/A          N/A            N/A          N/A
       TEM                                             HAC Positioner                  N/A          N/A            N/A          N/A




                                                                                                                            Reviewed by:
FCC ID: ZNFVS890                                             HAC (T-COIL) TEST REPORT
                                                                                                                            Quality Manager
Filename:                     Test Dates:                      EUT Type:
                                                                                                                            Page 24 of 37
0Y1306100972.ZNF            6/12/2013                          Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                                                        REV 7.0U
                                                                                                                                   01/18/11


5\meresr


               West Caldwell Calibration Laboratories Inc.




       Certificate of Calibration
                                                              for

                                                  Axial T Coil Probe
                                       Manufactured by:            TEM CONSULTING
                                       Model No:                   Axial T Coil Probe
                                       Serial No:                  TEM—1122
                                       Calibration Recall No:      22056
                                                         Submitted By:
                                       Customer:
                                       Company:
                                       Address:



  The subject instrument was calibrated to the indicated specification using standards traceable to the
  National Institute of Standards and Technology or to accepted values of natural physical constants,
  This document certifies that the instrument met the following specification uponits return to the
  submitter,

  West Caldwell Calibration Laboratories Procedure No.                       Axial T Cof TEM
  Uponreceipt for Calibration, the instrument was found to be:                                                  Noes
                                                                                                                e
                                                                                                                S he,(ol

                       Within        (Xx )      see attached Report of Calibration.                               : //

  the toleranceof the indicated specification,

  West Caldwell Calibration Laboratories‘ calibration control system meets the requirements, ISO
  10012—1 MIL—STD—45662A, ANSI/NCSL Z540—1, IEC Guide 25, ISO 9001;2008 and ISO 17025.




  Note: With this Certificate, Report of Calibration is included.                 Approved by:

  Calibration Date:                 12—Jul—12

  Certificate No:                   22056 ~!                                      Felix Christopher
  OA Dac, #1051 Rev. 2.0 101/01                    Certificate Page 1 of 1        Quality Manager
                                                                                            I80NEC 17025:2005
                                  West Caldwell
————._—_..____"                   Calibration
uncompromised calibration          Laboratories, Inc.


                                                                      HCATEMC_TEM—1122_Jul—12—2012

                                                                                                                                                     ISO/IEC 17026: 2005
                                                  West Caldwell
                                                   Calibration
      uncompromised calibration                       Laboratories, Inc.                                                                              (R               )
1575 State Route 96, Victor NY 14564                                                                                                         Calibration Lab, Cert. #f 1533.01




                                                                                                   for
                       TEM Consulting LP Axial T Coil Probe                                 Model No.: Axial T Coil Probe                                  Serial No.: TEM—1122

     Company :                                                                                                                                               1. D. No: 80580

Calibration results:                                                                                            Before data: .........                     After data: .........
                   Probe Sensitivity measured with Helmholtz Coil
                                                  Helmholtz Coil;                                                                    Before & after data same: ... X......
                               the number of turns on eachcoil;            10           No.
                               the radius of eachcoil, in meters;        0.204          m                                        Laboratory Environment:
                             the current in the coils, in amperes.;      0.08           A                                   Ambient Temperature:             22.1          °C
                                        Helmholtz Coil Constant;         6.99           AlmiV                                  Ambient Humidity:             47.3          % RH
                                  Helmholtz Coll magnetic field;         5.93           Alm                                    Ambient Pressure:             99.8          kPa
                                                                                                                                 Calibration Date:         12—Jul—12       10:06 AM
                                           Probe Sensitivity at          1000           Hz.                                    Re—calibration Due:         12Jul—13
                                                              was        —60.26         dBV/A/m                                   Report Number:            22056          ~1
                                                                         0.971          mV/Aim                                   Control Number:            22056
                                              Probe resistance            891           Ohms
The above listed instrument meets or exceeds the tested manufacturer‘s specifications.
This Calibration is traceable through NIST test numbers:                                205342
The expanded uncertainty of calibration: 0.30dB at 95% confidence level with a coverage factor of k=2.
Graph represents Probes Frequency Response.
                                                                                      Axial Probe Response
                                                                                                                                         —&— Measured Probe ..
                  20

                  15

                  10
 Magnitude (dB)

                  0




                       100                                                        Freq. (Hz)        1000                                                                              10000

The above listed instrument was checked using calibration procedure documented in West Caldwell
Calibration Laboratories Inc. procedure :                                                                                Rev. 5.0 Sept. 10, 2010 Doc. # 1038 HCATEMC
Calibration was performed by West Caldwell Calibration Laboratories Inc. under Operating Procedures
intended to implementthe requirements of ISO010012—1, IEC Guide 25, ANSI/NCSL 2540—1, (MIL—STD—45662A) and ISO 9001:2008, ISO 17025
                                                                                                                                                                L/   _
                   Cal. Date:    12—Jul—2012                            10:06 AM                                    Measurements performed by: ......
Calibrated on WCCL system type 9700                                                                                                            Felix Christopher
This document shall not be reproduced, except in full, without the written approval from West Galdwell Gal, Labs, Inc,                  Rev. 5.0 Sept. 10, 2010 Doc. # 1038 HCATEMG




                                                                                        Page 1 of 2



                                              2\ RCTEsST                                       .           .                                               @ LG                               —


                                                                HCATEMC_TEM—1122_Jul—12—2012

                                            West Caldwell Calibration Laboratories Inc.
                                                                      1575 State Route 96, Victor NY 14564
                                                                    Tel. (585) 586—3900 FAX (585) 586—4327

                                                        Calibration Data Record
                                                                                                  for
          TEM Consulting LP Axial T Coil Probe                                            Model No.: Axial T Coil Probe                           Serial No.: TEM—1122

                                                                                          Company :

Test                 Function                                                                 Tolerance                                    Measured values
                                                                                                                                 Before               Out              Remarks

1.0                  Probe Sensitivity at                                      1000 Hz.                      dBV/A/m             —60.26

                                                                                                                        dB
2.0                  Probe Level Linearity                                                                               6        6.00
                                                                                       Ref. (0 dB)                       0        0.00
                                                                                                                        —6        —6.00
                                                                                                                        12       ~12.00

                                                                                                                    Hz
3.0                  Probe Frequency Response                                                                       100          ~19.8
                                                                                                                    126          ~17.9
                                                                                                                    158          ~15.9
                                                                                                                    200          ~13.9
                                                                                                                    251          ~12.0
                                                                                                                    316          ~10.0
                                                                                                                    398           —8.0
                                                                                                                    501           —6.0
                                                                                                                    631           «3.9
                                                                                                                    794           —2.0
                                                                                       Ref. (0 dB)                 1000           0.0
                                                                                                                   1259            1.9
                                                                                                                   1585            3.9
                                                                                                                   1995            5.9
                                                                                                                   2512            7.9
                                                                                                                   3162            9.9
                                                                                                                   3981           11.9
                                                                                                                   5012           13.8
                                                                                                                   6310           15.9
                                                                                                                   7943           18.0
                                                                                                                   10000          20.1




Instruments used for calibration:                                                                                 Date of Cal.                 Traceablity No.              Dus Dato
                                                    34401A                       SIN   US360641                   17—0ct—2011                  ;205342                   16—0ct—2012
           HP                                       34401A                       SN    US361024                   17—0ct—2011                  205342                    16—0ct—2012
           HP                                       33120A                       S/N   $3604371                   17—0ct—2011                  ;205342                   16—0ct—2012
          B&K                                           2133                     S/N   1492410                     4—Nov—2011                  681/280411—11              4—Nov—2012



                            Cal. Date:           12—Jul—2012           10:06 AM                                                  Tested by: Felix Christopher
Calibrated on WCCL system type 9700
This document shall not be reproduced, except in full, without thewritten approval from Wost Caldwell Cal. Labs, Inc.              Rev. 5.0 Sept. 10, 2010 Doc. # 1038 HCATEMC




                                                                                       Page 2 of 2



                                      2 ecTtest                                               .          .                                        @ LG


               West Caldwell Calibration Laboratories Inc.




       Certificate of Calibration
                                                                  for

                                                    Radial T Coil Probe
                                         Manufactured by:            TEM CONSULTING
                                         Model No:                   Radial T Coil Probe
                                         Serial No:                  TEM—1128
                                         Calibration Recall No:      22056
                                                          Submitted By:

                                         Customer:
                                         Company:
                                         Address:



  The subject instrument was calibrated to the indicated specification using standards traceable to the
  National Institute of Standards and Technology or to accepted values of natural physical constants,
  This document certifies that the instrument met the following specification uponits return to the
  submitter,

  West Caldwell Calibration Laboratories Procedure No.                         Radial T C TEM

  Upon receipt for Calibration, the instrument was found to be:

                       Within           CX )       see attached Report of Calibration,

  the tolerance of the indicated specification.

  West Caldwell Calibration Laboratories‘ calibration control system meets the requirements, ISO
  10012—1 MIL—STD—45662A, ANSINCSL Z540—1, IEC Guide 25, ISO 9001:2008 and ISO 17025.




  Note: With this Certificate, Report of Calibration is included.                   Approved by:


  Calibration Date:                    12—Jul—12                                        E’C

  Certificate No:                      22056 ~2                                     Felix Christopher
  OA Dos. #1051 Rev. 2.0 101104                      Certificate Page 1 of 1        Quality Manager
                                                                                                ISO/IEC 17025:2005

                                  West Caldwell
m nnmnemnnmmces.                  Calibration
uncompromised calibration          Laboratories, Inc.
1575 State Route 96, Victor, NY 14564, U.S.A.

      5                            B




              2\   RCTEST                                     .         .                                       @ LG
              a


                                                                      HCRTEMC_TEM—1128_Jul—12—2012

                                                                                                                                                     I§O/IEC 17025; 2008
                                                  West Caldwell
                                                   Calibration
        uncompromised calibration\                     Laboratories, Inc.                                                                                    f
1575 State Route 96, Victor NY 14564                                                                                                         Calibration Lab. Cert. # 1533.01




                                                                                                   for
                       TEM Consulting LP Radial T Coil Probe                                Model No.: Radial T Coil Probe                              Serial No.: TEM—1128

       Company :                                                                                                                                            1. D. No: 80581

Calibration results:                                                                                            Before datai .........                    After datai .........
                   Probe Sensitivity measured with Helmholtz Coil
                                   Helmholtz Coil;                                                                                   Before & after data same: ... X......
                  the number of turns on each coil;  10       No.
                               the radius of eachcoil, in meters;        0.204          m                                        Laboratory Environment:
                             the current in the coils, in amperes.;      0.08           A                                   Ambient Temperature:            22.1           °C
                                        Helmholtz Coil Constant;         6.99           AlmIV                                  Ambient Humidity:           47.3            % RH
                                  Helmholtz Coil magnetic field;         5.89           Alm                                    Ambient Pressure:            99.8           kPa
                                                                                                                                 Calibration Date:       12—Jul—12         3:20 PM
                                           Probe Sensitivity at           1000          Hz.                                    Re—calibration Due:       12«Jul—13
                                                          was            —60.30         dBV/A/m                                   Report Number:           22056           —2
                                                                         0.966          mV/A/m                                    Control Number:          22056
                                              Probe resistance            902           Ohms
The above listed instrument meets or exceeds the tested manufacturer‘s specifications.
This Calibrationis traceable through NIST test numbers:                                 205342
The expanded uncertainty of calibration: 0.30d8 at_95% confidence level with a coverage factor of k=2.
Graph represents Probes Frequency Response.
                                                                                      Radial Probe Response
                  20                                                                                                                   —&~ Measured Probe Resp.
 Magnitude (dB)
                  o




                       100                                                       Freq. (Hz)         1000                                                                              10000

The above listed instrument was checked using calibration procedure documented in West Caldwell
Calibration Laboratories Inc. procedure :                                                                                Rev. 5.0 Sept. 10, 2010 Doc. # 1038 HCRTEMC
Calibration was performed by West Caldwell Calibration Laboratories Inc. under Operating Procedures
intended to implement the requirements of 1S010012—1, IEC Guide 25, ANSI/NCSL 2540—1, (MIL—STD—45662A) and ISO 9001:2008, ISO 17025
                                                                                                                                                                   l
                   Cal. Date:    12—Jul—2012                            3:20 PM                                     Measurements performed by: ......
Calibrated on WCCL system type 9700                                                                                                            Felix Christopher
This document shall not be reproduced, except In full, without the written approval from West Caldwell Gal, Labs, Inc.                  Rov. 5.0 Sept. 10, 2010 Doc. # 1038 HCRTEMC




                                                                                        Page 1 of 2



                                              2) BcTesr                                        .           .                                            @ LG


                                                                 HCRTEMC_TEM—1128_Jul—12—2012

                                             West Caldwell Calibration Laboratories Inc.
                                                                       1575 State Route 96, Victor NY 14564
                                                                     Tel. (585) 586—3900 FAX (585) 586—4327

                                                         Calibration Data Record
                                                                                                for
          TEM Consulting LP Radial T Coil Probe                                            Model No.: Radial T Coil Probe                          Serial No.: TEM—1128

                                                                                           Company :

Test                  Function                                                                 Tolerance                                    Measured values
                                                                                                                                  Before          Out       Remarks

1.0                  Probe Sensitivity at                                       1000 Hz.                      dBV/A/m             —60.30

                                                                                                                         dB
2.0                   Probe Level Linearity                                                                               6        6.00
                                                                                        Ref. (0 dB)                       0        0.00
                                                                                                                         —6       —6.00
                                                                                                                         12       ~12.00

                                                                                                                         Hz
3.0                  Probe Frequency Response                                                                         100         —20.0
                                                                                                                      126         17.9
                                                                                                                      158         ~15.9
                                                                                                                     200          14.0
                                                                                                                     251          ~12.0
                                                                                                                     316          ~10.0
                                                                                                                     398           —8.0
                                                                                                                      501          —6.0
                                                                                                                      631          ~4.0
                                                                                                                     794           —2.0
                                                                                        Ref. (0 dB)                  1000          0.0
                                                                                                                     1259          1.9
                                                                                                                     1585          3.9
                                                                                                                     1995          5.9
                                                                                                                     2512          7.9
                                                                                                                     3162          9.9
                                                                                                                     3981          11.9
                                                                                                                     5012          13.8
                                                                                                                     6310          15.9
                                                                                                                    7943           18.0
                                                                                                                    10000          201




Instruments used for calibration:                                                                                  Date of Cal.                 Traceability No.             Due Date
                                                     34401A                      S/N    US360641                   17—0ct—2011                  ,205342                   16—0ct—2012
           HP                                        34401A                      S/N    US361024                   17—0ct—2011                  ;205342                   16—0ct—2012
           HP                                        33120A                      S/N    $3604371                   17—0ct—2011                  206342                    16—0ct—2012
          B&K                                            2133                    S/N    1492410                     4—Nov—2011                  681/280411—11              4—Nov—2012



                            Cal. Date:            12—Jul—2012          3:20 PM                                                    Tested by: Felix Christopher
Calibrated on WCCL system type 9700
This document shall not be reproduced, except in full, without the written approval from Wost Caldwell Cal, Labs, Inc.              Rev. 5.0 Sopt. 10, 2010 Doc. # 1038 HCRTEMC




                                                                                        Page 2 of 2



                                        c\ RECTEST


11.         CONCLUSION

The measurements indicate that the wireless communications device complies with the HAC limits
specified in accordance with the ANSI C63.19 Standard and FCC WT Docket No. 01-309 RM-8658.
Precise laboratory measures were taken to assure repeatability of the tests. The tested device complies
with the requirements in respect to all parameters specific to the test. The test results and statements
relate only to the item(s) tested.

The measurement system and techniques presented in this evaluation are proposed in the ANSI standard
as a means of best approximating wireless device compatibility with a hearing-aid. The literature is under
continual re-construction.




                                                                                             Reviewed by:
FCC ID: ZNFVS890                              HAC (T-COIL) TEST REPORT
                                                                                             Quality Manager
Filename:                     Test Dates:       EUT Type:
                                                                                             Page 32 of 37
0Y1306100972.ZNF            6/12/2013           Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                         REV 7.0U
                                                                                                    01/18/11


12.         REFERENCES

     1. ANSI C63.19-2011, American National Standard for Methods of Measurement of Compatibility
        between Wireless communication devices and Hearing Aids.”, New York, NY, IEEE, May 2011

     2. FCC Public Notice DA 06-1215, Wireless Telecommunications Bureau and Office of Engineering
        and Technology Clarify Use of Revised Wireless Phone Hearing Aid Compatibility Standard, June
        6, 2006

     3. FCC 3G Review Guidance, Laboratory Division OET FCC, May/June 2006

     4. Berger, H. S., “Compatibility Between Hearing Aids and Wireless Devices,” Electronic Industries
        Forum, Boston, MA, May, 1997

     5. Berger, H. S., “Hearing Aid and Cellular Phone Compatibility: Working Toward Solutions,”
        Wireless Telephones and Hearing Aids: New Challenges for Audiology, Gallaudet University,
        Washington, D.C., May, 1997 (To be reprinted in the American Journal of Audiology).

     6. Berger, H. S., “Hearing Aid Compatibility with Wireless Communications Devices, “ IEEE
        International Symposium on Electromagnetic Compatibility, Austin, TX, August, 1997.

     7. Bronaugh, E. L., “Simplifying EMI Immunity (Susceptibility) Tests in TEM Cells,” in the 1990 IEEE
        International Symposium on Electromagnetic Compatibility Symposium Record, Washington,
        D.C., August 1990, pp. 488-491

     8. Byme, D. and Dillon, H., The National Acoustics Laboratory (NAL) New Procedure for Selecting
        the Gain and Frequency Response of a Hearing Aid, Ear and Hearing 7:257-265, 1986.

     9. Crawford, M. L., “Measurement of Electromagnetic Radiation from Electronic Equipment using
        TEM Transmission Cells, “ U.S. Department of Commerce, National Bureau of Standards, NBSIR
        73-306, Feb. 1973.

     10. Crawford, M. L., and Workman, J. L., “Using a TEM Cell for EMC Measurements of Electronic
         Equipment,” U.S. Department of Commerce, National Bureau of Standards. Technical Note 1013,
         July 1981.

     11. EHIMA GSM Project, Development phase, Project Report (1st part) Revision A. Technical-
         Audiological Laboratory and Telecom Denmark, October 1993.

     12. EHIMA GSM Project, Development phase, Part II Project Report. Technical-Audiological
         Laboratory and Telecom Denmark, June 1994.

     13. EHIMA GSM Project Final Report, Hearing Aids and GSM Mobile Telephones: Interference
         Problems, Methods of Measurement and Levels of Immunity. Technical-Audiological Laboratory
         and Telecom Denmark, 1995.

     14. HAMPIS Report, Comparison of Mobile phone electromagnetic near field with an upscaled
         electromagnetic far field, using hearing aid as reference, 21 October 1999.

     15. Hearing Aids/GSM, Report from OTWIDAM, Technical-Audiological Laboratory and Telecom
         Denmark, April 1993.

                                                                                             Reviewed by:
FCC ID: ZNFVS890                               HAC (T-COIL) TEST REPORT
                                                                                             Quality Manager
Filename:                     Test Dates:       EUT Type:
                                                                                             Page 33 of 37
0Y1306100972.ZNF            6/12/2013           Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                         REV 7.0U
                                                                                                    01/18/11


     16. IEEE 100, The Authoritative Dictionary of IEEE Standards Terms, Seventh Edition.

     17. Joyner, K. H, et. al., Interference to Hearing Aids by the New Digital Mobile Telephone System,
         Global System for Mobile (GSM) Communication Standard, National Acoustic Laboratory,
         Australian Hearing Series, Sydney 1993.

     18. Joyner, K. H., et. al., Interference to Hearing Aids by the Digital Mobile Telephone System, Global
         System for Mobile Communications (GSM), NAL Report #131, National Acoustic Laboratory,
         Australian Hearing Series, Sydney, 1995.

     19. Kecker, W. T., Crawford, M. L., and Wilson, W. A., “Contruction of a Transverse Electromagnetic
         Cell”, U.S. Department of Commerce, National Bureau of Standards, Technical Note 1011, Nov.
         1978.

     20. Konigstein, D., and Hansen, D., “A New Family of TEM Cells with enlarged bandwidth and
         Optimized working Volume,” in the Proceedings of the 7th International Symposium on EMC,
         Zurich, Switzerland, March 1987; 50:9, pp. 127-132.

     21. Kuk, F., and Hjorstgaard, N. K., “Factors affecting interference from digital cellular telephones,”
         Hearing Journal, 1997; 50:9, pp 32-34.

     22. Ma, M. A., and Kanda, M., ”Electromagnetic Compatibility and Interference Metrology,” U.S.
         Department of Commerce, National Bureau of Standards, Technical Note 1099, July 1986, pp.
         17-43.

     23. Ma, M. A., Sreenivashiah, I. , and Chang, D. C., “A Method of Determining the Emission and
         Susceptibility Levels of Electrically Small Objects Using a TEM Cell,” U.S. Department of
         Commerce, National Bureau of Standards, Technial Note 1040, July 1981.

     24. McCandless, G. A., and Lyregaard, P. E., Prescription of Gain/Output (POGO) for Hearing Aids,
         Hearing Instruments 1:16-21, 1983

     25. Skopec, M., “Hearing Aid Electromagnetic Interference from Digital Wireless Telephones, “IEEE
         Transactions on Rehabilitation Engineering, vol. 6, no. 2, pp. 235-239, June 1998.

     26. Technical Report, GSM 05.90, GSM EMC Considerations, European Telecommunications
         Standards Institute, January 1993.

     27. Victorian, T. A., “Digital Cellular Telephone Interference and Hearing Aid Compatibility—an
         Update,” Hearing Journal 1998; 51:10, pp. 53-60

     28. Wong, G. S. K., and Embleton, T. F. W., eds., AIP Handbook of Condenser Microphones: Theory,
         Calibration and Measurements, AIP Press.




                                                                                                  Reviewed by:
FCC ID: ZNFVS890                                 HAC (T-COIL) TEST REPORT
                                                                                                  Quality Manager
Filename:                     Test Dates:          EUT Type:
                                                                                                  Page 34 of 37
0Y1306100972.ZNF            6/12/2013              Portable Handset
© 2013 PCTEST Engineering Laboratory, Inc.                                                              REV 7.0U