16I22629-S1V1 SAR_App C Highest SAR Test Plots

FCC ID: ZNFVC200

RF Exposure Info

Download: PDF
FCCID_2901621

Test Laboratory: UL Verification Services Inc., SAR Lab 1                    Date/Time: 1/12/2016 9:25:36 AM

CDMA BC0

Frequency: 836.52 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C
Medium parameters used (interpolated): f = 836.52 MHz; σ = 1.018 S/m; ε r = 53.997; ρ = 1000 kg/m
                                                                                                  3

DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 5/22/2015
- Probe: EX3DV4 - SN7356; ConvF(9.97, 9.97, 9.97); Calibrated: 4/22/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI-A v5.0; Type: QDOVA002AA; Serial: TP 1194

Bodyworn (Position 2)/1xRTT RC3 SO32_ch 384/Area Scan (7x11x1): Measurement grid:
dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.871 W/kg

Bodyworn (Position 2)/1xRTT RC3 SO32_ch 384/Zoom Scan (5x5x7)/Cube 0: Measurement
grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 29.495 V/m; Power Drift = 0.08 dB
Peak SAR (extrapolated) = 1.14 W/kg
SAR(1 g) = 0.777 W/kg; SAR(10 g) = 0.507 W/kg
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.937 W/kg




                      0 dB = 0.937 W/kg = -0.28 dBW/kg




                                                                                                               Plot No. 1


Test Laboratory: UL Verification Services Inc., SAR Lab 1                    Date/Time: 1/12/2016 1:57:09 PM

CDMA BC0

Frequency: 836.52 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C
Medium parameters used (interpolated): f = 836.52 MHz; σ = 0.926 S/m; ε r = 41.92; ρ = 1000 kg/m
                                                                                                 3

DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 5/22/2015
- Probe: EX3DV4 - SN7356; ConvF(9.96, 9.96, 9.96); Calibrated: 4/22/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM; Type: QD000P40CD; Serial: TP 1751

Next-to-Mouth/1xRTT RC3 SO55_ch 384/Area Scan (7x11x1): Measurement grid: dx=15mm,
dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.761 W/kg

Next-to-Mouth/1xRTT RC3 SO55_ch 384/Zoom Scan (5x5x7)/Cube 0: Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 29.285 V/m; Power Drift = -0.05 dB
Peak SAR (extrapolated) = 0.936 W/kg
SAR(1 g) = 0.679 W/kg; SAR(10 g) = 0.463 W/kg
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.805 W/kg




                      0 dB = 0.805 W/kg = -0.94 dBW/kg




                                                                                                               Plot No. 2


Test Laboratory: UL Verification Services Inc., SAR Lab 3                    Date/Time: 1/11/2016 10:48:23 PM

CDMA BC1

Frequency: 1880 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C
Medium parameters used: f = 1880 MHz; σ = 1.522 S/m; ε r = 52.032; ρ = 1000 kg/m
                                                                                 3

DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/16/2015
- Probe: EX3DV4 - SN3749; ConvF(7.09, 7.09, 7.09); Calibrated: 1/26/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1213

Bodyworn (Position 2)/1xRTT RC3 SO32_ch 600/Area Scan (7x11x1): Measurement grid:
dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.622 W/kg

Bodyworn (Position 2)/1xRTT RC3 SO32_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement
grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 20.42 V/m; Power Drift = -0.20 dB
Peak SAR (extrapolated) = 0.872 W/kg
SAR(1 g) = 0.539 W/kg; SAR(10 g) = 0.313 W/kg
Maximum value of SAR (measured) = 0.675 W/kg




                      0 dB = 0.675 W/kg = -1.71 dBW/kg




                                                                                                               Plot No. 3


Test Laboratory: UL Verification Services Inc., SAR Lab 3                    Date/Time: 1/11/2016 8:27:59 PM

CDMA BC1

Frequency: 1880 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C
Medium parameters used: f = 1880 MHz; σ = 1.399 S/m; ε r = 39.132; ρ = 1000 kg/m
                                                                                 3

DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1434; Calibrated: 4/16/2015
- Probe: EX3DV4 - SN3749; ConvF(7.34, 7.34, 7.34); Calibrated: 1/26/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM with CRP; Type: SAM;

Next-to-Mouth/1xRTT RC3 SO55_ch 600/Area Scan (7x11x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 0.415 W/kg

Next-to-Mouth/1xRTT RC3 SO55_ch 600/Zoom Scan (5x5x7)/Cube 0: Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 17.33 V/m; Power Drift = 0.03 dB
Peak SAR (extrapolated) = 0.533 W/kg
SAR(1 g) = 0.320 W/kg; SAR(10 g) = 0.182 W/kg
Maximum value of SAR (measured) = 0.409 W/kg




                      0 dB = 0.409 W/kg = -3.88 dBW/kg




                                                                                                               Plot No. 4



Document Created: 2017-11-18 00:13:56
Document Modified: 2017-11-18 00:13:56

© 2025 FCC.report