SAR Appendix B

FCC ID: ZNFVC200

RF Exposure Info

Download: PDF
FCCID_2771534

Test Laboratory: UL Verification Services Inc. SAR Lab A                    Date/Time: 9/9/2015 9:37:03 AM

SystemPerformanceCheck-D1900V2 SN 5d043

Frequency: 1900 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C
Medium parameters used: f = 1900 MHz; σ = 1.555 S/m; ε r = 53.496; ρ = 1000 kg/m
                                                                                 3

DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1357; Calibrated: 2/20/2015
- Probe: EX3DV4 - SN3901; ConvF(7.68, 7.68, 7.68); Calibrated: 1/27/2015;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM v5.0 (A); Type: QD000P40CD; Serial: 1602

Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 5.18 W/kg

Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 59.04 V/m; Power Drift = -0.09 dB
Peak SAR (extrapolated) = 7.68 W/kg
SAR(1 g) = 4.12 W/kg; SAR(10 g) = 2.12 W/kg
Maximum value of SAR (measured) = 5.61 W/kg




                      0 dB = 5.61 W/kg = 7.49 dBW/kg




                                                                                                               Plot No. 1


1Test Laboratory: UL Verification Services Inc. SAR Lab A    Date/Time: 9/9/2015 9:54:49 AM

SystemPerformanceCheck-D1900V2 SN 5d043
Frequency: 1900 MHz; Duty Cycle: 1:1

Head/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 5.08 W/kg




                                                                                              Plot No. 2


Test Laboratory: UL Verification Services Inc. SAR Lab B                    Date/Time: 9/9/2015 10:31:07 AM

SystemPerformanceCheck-D835V2 SN 4d002

Frequency: 835 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C
Medium parameters used: f = 835 MHz; σ = 0.999 S/m; ε r = 52.723; ρ = 1000 kg/m
                                                                                3

DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1360; Calibrated: 3/12/2015
- Probe: EX3DV4 - SN3751; ConvF(8.47, 8.47, 8.47); Calibrated: 11/14/2014;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM; Type: QD000PCD; Serial: 1632

Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 1.09 W/kg

Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 33.911 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 1.46 W/kg
SAR(1 g) = 0.988 W/kg; SAR(10 g) = 0.652 W/kg
Maximum value of SAR (measured) = 1.20 W/kg




                      0 dB = 1.20 W/kg = 0.79 dBW/kg




                                                                                                               Plot No. 3


Test Laboratory: UL Verification Services Inc. SAR Lab B    Date/Time: 9/9/2015 10:50:47 AM

SystemPerformanceCheck-D835V2 SN 4d002
Frequency: 835 MHz; Duty Cycle: 1:1

Head/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 1.09 W/kg




                                                                                              Plot No. 4



Document Created: 2015-09-21 19:58:15