SAR Report

FCC ID: ZNFVC200

RF Exposure Info

Download: PDF
FCCID_2771533

                    SAR EVALUATION REPORT

                  CLASS II PERMISSIVE CHANGE


                       FCC 47 CFR § 2.1093
                        IEEE Std 1528-2013

                              For
                 CDMA/BT/BLE & WLAN b/g WATCH

                        FCC ID: ZNFVC200
Model Name: LG-VC200, LGVC200, VC200, LG-VC200B, LGVC200B, VC200B


                   Report Number: 15I21554-S1V1
                       Issue Date: 9/28/2015

                          Prepared for
            LG ELECTRONICS MOBILECOMM U.S.A., INC.
                     1000 SYLVAN AVENUE
             ENGLEWOOD CLIFFS, NEW JERSEY 07632

                           Prepared by
                 UL VERIFICATION SERVICES INC.
                     47173 BENICIA STREET
                   FREMONT, CA 94538, U.S.A.
                       TEL: (510) 771-1000
                       FAX: (510) 661-0888




                      NVLAP LAB CODE 200065-0


Report No.: 15I21554-S1V1                                                                        Issue Date: 9/28/2015

Revision History
 Rev.    Date             Revisions                                                        Revised By
 V1      9/28/2015        Initial Issue                                                    --




                                                    Page 2 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                                                       Issue Date: 9/28/2015

                                                                 Table of Contents

1.          Attestation of Test Results ......................................................................................................... 5

2.          Test Specification, Methods and Procedures............................................................................ 6

3.          Facilities and Accreditation ........................................................................................................ 6

4.          SAR Measurement System & Test Equipment .......................................................................... 7
     4.1.      SAR Measurement System ........................................................................................................ 7
     4.2.      SAR Scan Procedures ............................................................................................................... 8
     4.3.      Test Equipment........................................................................................................................ 10

5.          Measurement Uncertainty ......................................................................................................... 11

6.          Device Under Test (DUT) Information ...................................................................................... 12
     6.1.      DUT Description ...................................................................................................................... 12
     6.2.      Wireless Technologies ............................................................................................................. 12
     6.3.      Nominal and Maximum Output Power...................................................................................... 12

7.          RF Exposure Conditions (Test Configurations) ...................................................................... 13

8.          Dielectric Property Measurements & System Check .............................................................. 14
     8.1.      Dielectric Property Measurements ........................................................................................... 14
     8.2.      System Check.......................................................................................................................... 16

9.          Conducted Output Power Measurements................................................................................ 18
     9.1.      CDMA ...................................................................................................................................... 18
     9.2.      Wi-Fi 2.4GHz (DTS Band) ....................................................................................................... 18
     9.3.      Bluetooth ................................................................................................................................. 18

10.         Measured and Reported (Scaled) SAR Results ....................................................................... 19
     10.1.        CDMA BC0........................................................................................................................... 19
     10.2.        CDMA BC1........................................................................................................................... 19
     10.3.        Wi-Fi (DTS Band) and Bluetooth .......................................................................................... 20

11.         SAR Measurement Variability ................................................................................................... 22

12.         Simultaneous Transmission SAR Analysis ............................................................................. 23
     12.1.        Sum of the SAR for WWAN & Wi-Fi & BT............................................................................. 23

Appendixes .......................................................................................................................................... 24
     15I21554-S1V1 SAR_App A Photos & Ant. Locations ........................................................................ 24
     15I21554-S1V1 SAR_App B System Check Plots .............................................................................. 24
     15I21554-S1V1 SAR_App C SAR Highest SAR Test Plots ................................................................ 24
     15I21554-S1V1 SAR_App D Tissue Ingredients................................................................................. 24
                                                    Page 3 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                               Issue Date: 9/28/2015
  15I21554-S1V1 SAR_App E Probe Cal. Certificates .......................................................................... 24
  15I21554-S1V1 SAR_App F Dipole Cal. Certificates .......................................................................... 24




                                                    Page 4 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                        Issue Date: 9/28/2015

1. Attestation of Test Results
Applicant Name                     LG ELECTRONICS MOBILECOMM U.S.A., INC.
FCC ID                             ZNFVC200
Model Name                         LG-VC200, LGVC200, VC200, LG-VC200B, LGVC200B, VC200B
                                   FCC 47 CFR § 2.1093
Applicable Standards               Published RF exposure KDB procedures
                                   IEEE Std 1528-2013
                                                  SAR Limits (W/Kg)
                                                                              Extremities (hands, wrists, ankles, etc.)
      Exposure Category               Peak spatial-average(1g of tissue)
                                                                                           (10g of tissue)
      General population /
                                                      1.6                                         4
     Uncontrolled exposure
                                          The Highest Reported SAR (W/kg)
                                                                   Equipment Class
RF Exposure Conditions
                                        Licensed                DTS                  U-NII              DSS (BT)
Extremity                                 2.374
                                                                N/A                                        N/A
Next To Mouth                             0.594
                                                                                      N/A
Simultaneous      Extremity               2.508                2.458                                      2.508
Tx                Next To Mouth           0.761                0.699                                      0.761
Date Tested                        9/9/2015 to 9/11/2015
Test Results                       Pass
 UL Verification Services Inc. tested the above equipment in accordance with the requirements set forth in the
 above standards. All indications of Pass/Fail in this report are opinions expressed by UL Verification Services Inc.
 based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into
 account and are published for informational purposes only. The test results show that the equipment tested is
 capable of demonstrating compliance with the requirements as documented in this report.
Note: The results documented in this report apply only to the tested sample, under the conditions and modes of
operation as described herein. This document may not be altered or revised in any way unless done so by UL
Verification Services Inc. and all revisions are duly noted in the revisions section. Any alteration of this document
not carried out by UL Verification Services Inc. will constitute fraud and shall nullify the document. This report must
not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any agency of
the Federal Government, or any agency of any government (NIST Handbook 150, Annex A). This report is written
to support regulatory compliance of the applicable standards stated above.
Approved & Released By:                                     Prepared By:




Bobby Bayani                                                Jose Abadilla
Senior Engineer                                             Laboratory Technician
UL Verification Services Inc.                               UL Verification Services Inc.




                                                    Page 5 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                        Issue Date: 9/28/2015

2. Test Specification, Methods and Procedures
The tests documented in this report were performed in accordance with FCC 47 CFR § 2.1093, IEEE STD 1528-
2013, the following FCC Published RF exposure KDB procedures:
   o 248227 D01 802.11 Wi-Fi SAR v02r01
   o 447498 D01 General RF Exposure Guidance v05r02
   o 690783 D01 SAR Listings on Grants v01r03
   o 865664 D01 SAR measurement 100 MHz to 6 GHz v01r04
   o 865664 D02 RF Exposure Reporting v01r01
   o 941225 D01 3G SAR Procedures v03

3. Facilities and Accreditation
The test sites and measurement facilities used to collect data are located at

             47173 Benicia Street                             47266 Benicia Street
                  SAR Lab A                                        SAR Lab 1
                  SAR Lab B                                        SAR Lab 2
                  SAR Lab C                                        SAR Lab 3
                  SAR Lab D                                        SAR Lab 4
                  SAR Lab E                                        SAR Lab 5
                  SAR Lab F
                  SAR Lab G
                  SAR Lab H

UL Verification Services Inc. is accredited by NVLAP, Laboratory Code 200065-0.




                                                    Page 6 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                         Issue Date: 9/28/2015

4. SAR Measurement System & Test Equipment
4.1.    SAR Measurement System
The DASY5 system used for performing compliance tests consists of the following items:




   A standard high precision 6-axis robot with controller, teach pendant and software. An arm extension for
    accommodating the data acquisition electronics (DAE).
   An isotropic Field probe optimized and calibrated for the targeted measurement.
   A data acquisition electronics (DAE) which performs the signal amplification, signal multiplexing, AD-
    conversion, offset measurements, mechanical surface detection, collision detection, etc. The unit is battery
    powered with standard or rechargeable batteries. The signal is optically transmitted to the EOC.
   The Electro-optical converter (EOC) performs the conversion from optical to electrical signals for the digital
    communication to the DAE. To use optical surface detection, a special version of the EOC is required. The
    EOC signal is transmitted to the measurement server.
   The function of the measurement server is to perform the time critical tasks such as signal filtering, control of
    the robot operation and fast movement interrupts.
   The Light Beam used is for probe alignment. This improves the (absolute) accuracy of the probe positioning.
   A computer running WinXP or Win7 and the DASY5 software.
   Remote control and teach pendant as well as additional circuitry for robot safety such as warning lamps, etc.
   The phantom, the device holder and other accessories according to the targeted measurement.




                                                    Page 7 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                        Issue Date: 9/28/2015

4.2. SAR Scan Procedures
Step 1: Power Reference Measurement
The Power Reference Measurement and Power Drift Measurements are for monitoring the power drift of the device
under test in the batch process. The minimum distance of probe sensors to surface determines the closest
measurement point to phantom surface. The minimum distance of probe sensors to surface is 2.1 mm. This
distance cannot be smaller than the distance of sensor calibration points to probe tip as defined in the probe
properties.

Step 2: Area Scan
The Area Scan is used as a fast scan in two dimensions to find the area of high field values, before doing a fine
measurement around the hot spot. The sophisticated interpolation routines implemented in DASY software can find
the maximum locations even in relatively coarse grids. When an Area Scan has measured all reachable points, it
computes the field maximal found in the scanned area, within a range of the global maximum. The range (in dB) is
specified in the standards for compliance testing. For example, a 2 dB range is required in IEEE Standard 1528
and IEC 62209 standards, whereby 3 dB is a requirement when compliance is assessed in accordance with the
ARIB standard (Japan). If only one Zoom Scan follows the Area Scan, then only the absolute maximum will be
taken as reference. For cases where multiple maximums are detected, the number of Zoom Scans has to be
increased accordingly.
Area Scan Parameters extracted from KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz




                                                    Page 8 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                        Issue Date: 9/28/2015
Step 3: Zoom Scan
Zoom Scans are used to assess the peak spatial SAR values within a cubic averaging volume containing 1 g and
10 g of simulated tissue. The Zoom Scan measures points (refer to table below) within a cube whose base faces
are centered on the maxima found in a preceding area scan job within the same procedure. When the
measurement is done, the Zoom Scan evaluates the averaged SAR for 1 g and 10 g and displays these values
next to the job’s label.
Zoom Scan Parameters extracted from KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz




Step 4: Power drift measurement
The Power Drift Measurement measures the field at the same location as the most recent power reference
measurement within the same procedure, and with the same settings. The Power Drift Measurement gives the field
difference in dB from the reading conducted within the last Power Reference Measurement. This allows a user to
monitor the power drift of the device under test within a batch process. The measurement procedure is the same as
Step 1.

Step 5: Z-Scan (FCC only)
The Z Scan measures points along a vertical straight line. The line runs along the Z-axis of a one-dimensional grid.
In order to get a reasonable extrapolation the extrapolated distance should not be larger than the step size in Z-
direction.




                                                    Page 9 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                             Issue Date: 9/28/2015

4.3. Test Equipment
The measuring equipment used to perform the tests documented in this report has been calibrated in accordance
with the manufacturers’ recommendations, and is traceable to recognized national standards.
Dielectric Property Measurements
Name of Equipment                           Manufacturer           Type/Model           Serial No.        Cal. Due Date
Network Analyzer                               Agilent               E753ES            MY40000980           4/17/2016
Dielectric Probe kit                           SPEAG                 DAK-3.5               1087            11/11/2015
Shorting block                                 SPEAG              DAK-3.5 Short       SM DAK 200 BA           N/A
Thermometer                                Control Company          Traceable           122529162           10/8/2015


System Check
Name of Equipment                           Manufacturer           Type/Model           Serial No.       Cal. Due Date
Synthesized Signal Generator                    HP                   8665B            3744A01155           3/18/2016
Power Meter                                     HP                   437B             3125U16345           6/15/2016
Power Meter                                     HP                   437B             3125U12345           7/31/2016
Power Sensor                                    HP                   8481A            1926A27048           8/3/2016
Power Sensor                                    HP                   8481A            2702A76223           9/3/2016
Amplifier                                     MITEQ          AMF-4D-00400600-50-30P     1795092               N/A
Directional coupler                          Werlatone             C8060-102              2141                N/A
DC Power Supply                            BK PRECISION              1611              215-02292              N/A
E-Field Probe (SAR Lab A)                     SPEAG                 EX3DV4                3901             1/27/2016
E-Field Probe (SAR Lab B)                     SPEAG                 EX3DV4                3751            11/14/2015
Data Acquisition Electronics (SAR Lab A)      SPEAG                  DAE4                 1357             2/20/2016
Data Acquisition Electronics (SAR Lab B)      SPEAG                  DAE4                 1360             3/12/2016
System Validation Dipole                      SPEAG                 D835V2               4d002            11/13/2015
System Validation Dipole                      SPEAG                 D1900V2              5d043             11/7/2015
Thermometer (SAR Lab A)                       EXTECH                445703              CCS-206            3/19/2016
Thermometer (SAR Lab B)                       EXTECH                445703              CCS-249            9/18/2015
Other
Name of Equipment                           Manufacturer           Type/Model           Serial No.       Cal. Due Date
Base Station Simulator                         R&S                  CMU200               838114            8/14/2016




                                                   Page 10 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                        Issue Date: 9/28/2015

5. Measurement Uncertainty
Per KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz, when the highest measured 1-g SAR within a
frequency band is < 1.5 W/kg, the extensive SAR measurement uncertainty analysis described in IEEE Std 1528-
2013 is not required in SAR reports submitted for equipment approval.




                                                   Page 11 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                                                  Issue Date: 9/28/2015

6. Device Under Test (DUT) Information
6.1.     DUT Description
                                 Overall (Length x Width): 56 mm x 41.5 mm
 Device Dimension                Overall Diagonal: 53.8 mm
                                 Display Diagonal: 33 mm
 Back Cover                      The rechargeable battery is not user accessible.
 Battery Options                 The rechargeable battery is not user accessible.
                                 Wi-Fi Hotspot mode permits the device to share its cellular data connection with other Wi-Fi-enabled devices.
 Wireless Router (Hotspot)
                                 Wi-Fi Hotspot mode is NOT SUPPORTED
                                 Wi-Fi Direct enabled devices transfer data directly between each other
 Wi-Fi Direct
                                 Wi-Fi Direct is NOT SUPPORTED
                                           S/N                       IMEI                                          Notes

                                       0220-0658              A1000040E032A21                               Conducted Sample
 Test sample information
                                       0220-0651              A1000040E03A1A                                   SAR Sample

                                       0220-0652              A1000040E03A1B                                   SAR Sample


6.2.     Wireless Technologies
       Wireless                                                                                                         Duty Cycle used for SAR
                             Frequency bands                                Operating mode
     technologies                                                                                                               testing
                           BC0
 CDMA (CDMA2000)                                      1xRTT (Voice & Data)                                             100%
                           BC1
                                                      802.11b
 Wi-Fi                     2.4 GHz                                                                                     100%
                                                      802.11g
 Bluetooth                 2.4 GHz                    Version 4.0 LE                                                   77.5% (DH5)

6.3.     Nominal and Maximum Output Power
KDB 447498 sec.4.1.(3) at the maximum rated output power and within the tune-up tolerance range specified for
the product, but not more than 2 dB lower than the maximum tune-up tolerance limit

Upper limit (dB):      -1.5      ~     0.5               Max. RF Output Pow er (dBm)
                                                                                    Max. tune-up
RF Air interface              Mode                       Target
                                                                                    tolerance limit
   CDMA BC0                  1xRTT                        23.7                           24.2
   CDMA BC1                  1xRTT                        21.2                           21.7
Upper limit (dB):                      1.0               Max. RF Output Pow er (dBm)
                                                                                    Max. tune-up
RF Air interface              Mode                       Target
                                                                                    tolerance limit
                             802.11b                       6.0                            7.0
  WiFi 2.4 GHz
                             802.11g                       5.0                           6.0
                 Bluetooth                                 8.0                           9.0
                Bluetooth LE                               7.0                           8.0




                                                   Page 12 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                        Issue Date: 9/28/2015

7. RF Exposure Conditions (Test Configurations)
Refer to “SAR Photos and Ant locations” Appendix for the specific details of the antenna-to-antenna and
antenna-to-edge(s) distances.

     Wireless          RF Exposure         DUT-to-User            Test             Antenna-to-           SAR
   technologies         Conditions          Separation           Position         edge/surface         Required
                         Extremity
                                                0                 Rear               N/A                 Yes
      WLAN           (Hand/Wrist/Ankle)
                      Next to Mouth             10                Front              N/A                 Yes

The neck region of the SAM phantom was chosen for wrist-worn extremity SAR testing in accordance with KDB
447498 §6.2.
A non-standard setup was used for SAR testing based on guidance from the FCC. The operational description
contains additional information.




                                                   Page 13 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                        Issue Date: 9/28/2015

8. Dielectric Property Measurements & System Check
8.1.    Dielectric Property Measurements
The temperature of the tissue-equivalent medium used during measurement must also be within 18C to 25C and
within ± 2C of the temperature when the tissue parameters are characterized.
The dielectric parameters must be measured before the tissue-equivalent medium is used in a series of SAR
measurements. The parameters should be re-measured after each 3 – 4 days of use; or earlier if the dielectric
parameters can become out of tolerance; for example, when the parameters are marginal at the beginning of the
measurement series.
Tissue dielectric parameters were measured at the low, middle and high frequency of each operating frequency
range of the test device.

Tissue Dielectric Parameters
FCC KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz
                                                 Head                                       Body
    Target Frequency (MHz)
                                       er                  s (S/m)                 er                 s (S/m)
             150                      52.3                  0.76                  61.9                 0.80
             300                      45.3                  0.87                  58.2                 0.92
             450                      43.5                  0.87                  56.7                 0.94
             835                      41.5                  0.90                  55.2                 0.97
             900                      41.5                  0.97                  55.0                 1.05
             915                      41.5                  0.98                  55.0                 1.06
            1450                      40.5                  1.20                  54.0                 1.30
            1610                      40.3                  1.29                  53.8                 1.40
         1800 – 2000                  40.0                  1.40                  53.3                 1.52
            2450                      39.2                  1.80                  52.7                 1.95
            3000                      38.5                  2.40                  52.0                 2.73
            5000                      36.2                  4.45                  49.3                 5.07
            5100                      36.1                  4.55                  49.1                 5.18
            5200                      36.0                  4.66                  49.0                 5.30
            5300                      35.9                  4.76                  48.9                 5.42
            5400                      35.8                  4.86                  48.7                 5.53
            5500                      35.6                  4.96                  48.6                 5.65
            5600                      35.5                  5.07                  48.5                 5.77
            5700                      35.4                  5.17                  48.3                 5.88
            5800                      35.3                  5.27                  48.2                 6.00

IEEE Std 1528-2013
Refer to Table 3 within the IEEE Std 1528-2013




                                                   Page 14 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                                 Issue Date: 9/28/2015
Dielectric Property Measurements Results:

SAR Lab A
     Date       Freq. (MHz)                  Liquid Parameters                       Measured   Target   Delta (%)   Limit ±(%)
                              e'   40.6000             Relative Permittivity (єr):    40.60     40.00      1.50          5
                Head 1900
                              e"   13.3200                     Conductivity (σ):       1.41     1.40       0.51          5
                              e'   40.7000             Relative Permittivity (єr):    40.70     40.00      1.75          5
   9/9/2015     Head 1850
                              e"   13.2900                     Conductivity (σ):       1.37     1.40       -2.35         5
                              e'   40.5700             Relative Permittivity (єr):    40.57     40.00      1.43          5
                Head 1910
                              e"   13.3500                     Conductivity (σ):       1.42     1.40       1.27          5
                              e'   53.5000             Relative Permittivity (єr):    53.50     53.30      0.38          5
                Body 1900
                              e"   14.7100                     Conductivity (σ):       1.55     1.52       2.24          5
                              e'   53.6900             Relative Permittivity (єr):    53.69     53.30      0.73          5
   9/9/2015     Body 1850
                              e"   14.7300                     Conductivity (σ):       1.52     1.52       -0.31         5
                              e'   53.4500             Relative Permittivity (єr):    53.45     53.30      0.28          5
                Body 1910
                              e"   14.7600                       Conductivity (σ):     1.57     1.52       3.13          5


SAR Lab B
     Date       Freq. (MHz)                  Liquid Parameters                       Measured   Target   Delta (%)   Limit ±(%)
                              e'   40.1700             Relative Permittivity (єr):    40.17     41.50      -3.20         5
                Head 835
                              e"   19.9800                     Conductivity (σ):       0.93     0.90       3.07          5
                              e'   40.3800             Relative Permittivity (єr):    40.38     41.60      -2.94         5
   9/9/2015     Head 820
                              e"   20.0400                     Conductivity (σ):       0.91     0.90       1.70          5
                              e'   40.0400             Relative Permittivity (єr):    40.04     41.50      -3.52         5
                Head 850
                              e"   19.8500                     Conductivity (σ):       0.94     0.92       2.53          5
                              e'   52.7200             Relative Permittivity (єr):    52.72     55.20      -4.49         5
                Body 835
                              e"   21.5000                     Conductivity (σ):       1.00     0.97       2.91          5
                              e'   52.9300             Relative Permittivity (єr):    52.93     55.28      -4.25         5
   9/9/2015     Body 820
                              e"   21.5600                     Conductivity (σ):       0.98     0.97       1.50          5
                              e'   52.6100             Relative Permittivity (єr):    52.61     55.16      -4.62         5
                Body 850
                              e"   21.4200                       Conductivity (σ):     1.01     0.99       2.56          5




                                                   Page 15 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                        Issue Date: 9/28/2015

8.2.    System Check
SAR system verification is required to confirm measurement accuracy, according to the tissue dielectric media,
probe calibration points and other system operating parameters required for measuring the SAR of a test device.
The system verification must be performed for each frequency band and within the valid range of each probe
calibration point required for testing the device. The same SAR probe(s) and tissue-equivalent media combinations
used with each specific SAR system for system verification must be used for device testing. When multiple probe
calibration points are required to cover substantially large transmission bands, independent system verifications are
required for each probe calibration point. A system verification must be performed before each series of SAR
measurements using the same probe calibration point and tissue-equivalent medium. Additional system verification
should be considered according to the conditions of the tissue-equivalent medium and measured tissue dielectric
parameters, typically every three to four days when the liquid parameters are re-measured or sooner when
marginal liquid parameters are used at the beginning of a series of measurements.

System Performance Check Measurement Conditions:
   The measurements were performed in the flat section of the TWIN SAM or ELI phantom, shell thickness: 2.0
    ±0.2 mm (bottom plate) filled with Body or Head simulating liquid of the following parameters.
   The depth of tissue-equivalent liquid in a phantom must be ≥ 15.0 cm for SAR measurements ≤ 3 GHz and ≥
    10.0 cm for measurements > 3 GHz.
   The DASY system with an E-Field Probe was used for the measurements.
   The dipole was mounted on the small tripod so that the dipole feed point was positioned below the center
    marking of the flat phantom section and the dipole was oriented parallel to the body axis (the long side of the
    phantom). The standard measuring distance was 10 mm (above 1 GHz) and 15 mm (below 1 GHz) from dipole
    center to the simulating liquid surface.
   The coarse grid with a grid spacing of 15 mm was aligned with the dipole.
    For 5 GHz band - The coarse grid with a grid spacing of 10 mm was aligned with the dipole.
   Special 7x7x7 (below 3 GHz) and/or 8x8x7 (above 3 GHz) fine cube was chosen for the cube.
   Distance between probe sensors and phantom surface was set to 3 mm.
    For 5 GHz band - Distance between probe sensors and phantom surface was set to 2.5 mm
   The dipole input power (forward power) was 100 mW.
   The results are normalized to 1 W input power.




                                                   Page 16 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                                      Issue Date: 9/28/2015
Reference Target SAR Values
The reference SAR values can be obtained from the calibration certificate of system validation dipoles
                                                                                             Target SAR Values (W/kg)
  System Dipole         Serial No.            Cal. Date       Freq. (MHz)
                                                                                   1g/10g             Head               Body
                                                                                     1g               9.23               9.33
    D835V2                4d002              11/13/2014            835
                                                                                     10g              5.99               6.12
                                                                                     1g               40.6               40.0
    D1900V2               5d043              11/7/2014             1900
                                                                                     10g              21.1               21.3

System Check Results
The 1-g and 10-g SAR measured with a reference dipole, using the required tissue-equivalent medium at the test
frequency, must be within 10% of the manufacturer calibrated dipole SAR target.

SAR Lab A
                      System Dipole                                      Measured Results
                                                     T.S.                                         Target        Delta       Plot
 Date Tested                                                       Zoom Scan to    Normalize
                   Type           Serial #          Liquid                                      (Ref. Value)    ±10 %       No.
                                                                     100 mW         to 1 W
                                                             1g        4.12          41.20         40.00         3.00
   9/9/215        03/14/05        5d043           Body                                                                      1,2
                                                             10g       2.12          21.20         21.30         -0.47
                                                             1g        4.05          40.50         40.60         -0.25
   9/9/215        03/14/05        5d043           Head
                                                             10g       2.08          20.80         21.10         -1.42


SAR Lab B
                      System Dipole                                      Measured Results
                                                     T.S.                                         Target        Delta       Plot
 Date Tested                                                       Zoom Scan to    Normalize
                   Type           Serial #          Liquid                                      (Ref. Value)    ±10 %       No.
                                                                     100 mW         to 1 W
                                                             1g       0.988          9.88          9.33          5.89
  9/9/2015        D835V2          4d002           Body                                                                      3, 4
                                                             10g      0.652          6.52          6.12          6.54
                                                             1g       0.870          8.70          9.23          -5.74
  9/9/2015        D835V2          4d002           Head
                                                             10g      0.570          5.70          5.99          -4.84




                                                   Page 17 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                           Issue Date: 9/28/2015

9. Conducted Output Power Measurements
9.1.    CDMA
CDMA BC0 Measured Results
                                                                              Freq.      Avg. Pwr
    Band                          Mode                          Ch No.
                                                                             (MHz)        (dBm)
                                                                 1013       824.70         24.0
                                      RC1 SO55
                                                                  384       836.52         24.0
                                      (Loopback)
                                                                  777       848.31         23.7
                                                                 1013       824.70         23.9
                                      RC3 SO55
    BC 0        1xRTT                                             384       836.52         24.0
                                      (Loopback)
                                                                 777        848.31         23.8
                                                                 1013       824.70         24.0
                                      RC3 SO32
                                                                 384        836.52         24.0
                                      (+F-SCH)
                                                                 777        848.31         24.1

CDMA BC1 Measured Results
                                                                              Freq.      Avg. Pwr
    Band                          Mode                          Ch No.
                                                                             (MHz)        (dBm)
                                                                 25         1851.25        21.6
                                      RC1 SO55
                                                                 600        1880.00        21.3
                                      (Loopback)
                                                                 1175       1908.75        21.2
                                                                  25        1851.25        21.7
                                      RC3 SO55
    BC 1        1xRTT                                             600       1880.00        21.3
                                      (Loopback)
                                                                 1175       1908.75        21.5
                                                                  25        1851.25        21.7
                                      RC3 SO32
                                                                 600        1880.00        21.3
                                      (+F-SCH)
                                                                 1175       1908.75        21.2

9.2.    Wi-Fi 2.4GHz (DTS Band)
Maximum tune-up tolerance limit is 7.00 dBm. This power level qualifies for exclusion of SAR testing. Please refer
to Section 10.3 for further details.

9.3.    Bluetooth
Maximum tune-up tolerance limit is 9.00 dBm. This power level qualifies for exclusion of SAR testing. Please refer
to Section 10.3 for further details.




                                                   Page 18 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                                       Issue Date: 9/28/2015

10.       Measured and Reported (Scaled) SAR Results
SAR Test Reduction criteria are as follows:

KDB 447498 D01 General RF Exposure Guidance:
Testing of other required channels within the operating mode of a frequency band is not required when the reported 1-g or 10-g
SAR for the mid-band or highest output power channel is:
   ≤ 0.8 W/kg or 2.0 W/kg, for 1-g or 10-g respectively, when the transmission band is ≤ 100 MHz
   ≤ 0.6 W/kg or 1.5 W/kg, for 1-g or 10-g respectively, when the transmission band is between 100 MHz and 200 MHz
   ≤ 0.4 W/kg or 1.0 W/kg, for 1-g or 10-g respectively, when the transmission band is ≥ 200 MHz

KDB 941225 D01 SAR test for 3G devices:
When the maximum output power and tune-up tolerance specified for production units in a secondary mode is ≤ ¼ dB higher
than the primary mode or when the highest reported SAR of the primary mode is scaled by the ratio of specified maximum
output power and tune-up tolerance of secondary to primary mode and the adjusted SAR is ≤ 1.2 W/kg, SAR measurement is
not required for the secondary mode


10.1. CDMA BC0
                                                                               Power (dBm)     1-g SAR (W/kg)   10-g SAR (W/kg)
   RF Exposure                      Dist.                            Freq.                                                        Plot
                        Mode                Test Position   Ch #.            Tune-up
    Conditions                     (mm)                             (MHz)              Meas.   Meas.   Scaled   Meas.    Scaled   No.
                                                                               limit
                                                            1013    824.7     24.2     24.0                     2.260    2.367
                        1xRTT
      Extremity                      0         Neck         384     836.5     24.2     24.0                     2.200    2.304
                      (RC3 SO32)
                                                            777     848.3     24.2     24.1                     2.320    2.374     1
                        1xRTT
  Next - to - Mouth                 10          Flat        384     836.5     24.2     24.0    0.324    0.339                      2
                      (RC3 SO55)

10.2. CDMA BC1
                                                                               Power (dBm)     1-g SAR (W/kg)   10-g SAR (W/kg)
   RF Exposure                      Dist.                            Freq.                                                        Plot
                        Mode                Test Position   Ch #.            Tune-up
    Conditions                     (mm)                             (MHz)              Meas.   Meas.   Scaled   Meas.    Scaled   No.
                                                                               limit
                        1xRTT
      Extremity                      0         Neck         600     1880.0    21.7     21.3                     1.580    1.732     3
                      (RC3 SO32)
                        1xRTT
  Next - to - Mouth                 10          Flat        600     1880.0    21.7     21.3    0.542    0.594                      4
                      (RC3 SO55)




                                                   Page 19 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                                  Issue Date: 9/28/2015

10.3. Wi-Fi (DTS Band) and Bluetooth
Standalone SAR Test Exclusion Considerations & Estimated SAR
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)]·[√f(GHz)] ≤ 3.0, for 1-g SAR
and ≤ 7.5 for 10-g extremity SAR, where
        f(GHz) is the RF channel transmit frequency in GHz
        Power and distance are rounded to the nearest mW and mm before calculation
        The result is rounded to one decimal place for comparison
The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a
distance of 5 mm is applied to determine SAR test exclusion.

When the standalone SAR test exclusion is applied to an antenna that transmits simultaneously with other
antennas, the standalone SAR must be estimated according to following to determine simultaneous transmission
SAR test exclusion:
        (max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)]·[√f(GHz)/x] W/kg for test
         separation distances ≤ 50 mm;
                  where x = 7.5 for 1-g SAR, and x = 18.75 for 10-g SAR.
        0.4 W/kg for 1-g SAR and 1.0 W/kg for 10-g SAR, when the test separation distances is > 50 mm.


Extremity Exposure Conditions:

WLAN
  Max. tune-up tolerance limit          Min. test         Frequency          SAR test            Test             Estimated
                                       separation           (GHz)            exclusion       Configuration        10-g SAR
     (dBm)              (mW)         distance (mm)                            Result*                              (W/kg)
    7.0                   5                  5                2.462              1.6              Neck              0.084
Conclusion:
*: The computed value is < 7.5; therefore, Wi-Fi 2.4GHz qualifies for Extremity SAR test exclusion.

Bluetooth
  Max. tune-up tolerance limit          Min. test         Frequency          SAR test            Test             Estimated
                                       separation           (GHz)            exclusion       Configuration        10-g SAR
     (dBm)              (mW)         distance (mm)                            Result*                              (W/kg)
    9.0                   8                  5                2.480              2.5              Neck              0.134
Conclusion:
*: The computed value is < 7.5; therefore, Bluetooth qualifies for Standalone SAR test exclusion.




                                                   Page 20 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                        Issue Date: 9/28/2015
Next to Mouth Exposure Conditions:

WLAN
  Max. tune-up tolerance limit       Min. test      Frequency         SAR test          Test           Estimated
                                    separation        (GHz)           exclusion     Configuration      1-g SAR
     (dBm)            (mW)        distance (mm)                        Result*                          (W/kg)
    7.0                 5               10             2.462             0.8              Flat           0.105
Conclusion:
*: The computed value is ≤ 3; therefore, Wi-Fi 2.4GHz qualifies for Next to Mouth SAR test exclusion.

Bluetooth
  Max. tune-up tolerance limit       Min. test      Frequency         SAR test          Test           Estimated
                                    separation        (GHz)           exclusion     Configuration      1-g SAR
     (dBm)            (mW)        distance (mm)                        Result*                          (W/kg)
    9.0                 8               10             2.462             1.3              Flat           0.167
Conclusion:
*: The computed value is ≤ 3; therefore, Wi-Fi 2.4GHz qualifies for Next to Mouth SAR test exclusion.




                                                   Page 21 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                                Issue Date: 9/28/2015

11.        SAR Measurement Variability
In accordance with published RF Exposure KDB 865664 D01 SAR measurement 100 MHz to 6 GHz. These
additional measurements are repeated after the completion of all measurements requiring the same head or body
tissue-equivalent medium in a frequency band. The test device should be returned to ambient conditions (normal
room temperature) with the battery fully charged before it is re-mounted on the device holder for the repeated
measurement(s) to minimize any unexpected variations in the repeated results.

1) Repeated measurement is not required when the original highest measured SAR is < 0.80 W/kg; steps 2)
   through 4) do not apply.
2) When the original highest measured SAR is ≥ 0.80 W/kg, repeat that measurement once.
3) Perform a second repeated measurement only if the ratio of largest to smallest SAR for the original and first
   repeated measurements is > 1.20 or when the original or repeated measurement is ≥ 1.45 W/kg (~ 10% from
   the 1-g SAR limit).
4) Perform a third repeated measurement only if the original, first or second repeated measurement is ≥1.5 W/kg
   and the ratio of largest to smallest SAR for the original, first and second repeated measurements is > 1.20.

Extremity
 Frequency                                                                Repeated      Highest       Repeated     Largest to
    Band         Air Interface   RF Exposure Conditions   Test Position     SAR      Measured SAR   Measured SAR    Smallest
   (MHz)                                                                  (Yes/No)      (W/kg)         (W/kg)      SAR Ratio
                                        Extremity
    850          CDMA BC0                                     Neck          Yes          2.32           2.30          1.01
                                    (Hand/Wrist/Ankle)
                                        Extremity
    1900         CDMA BC1                                     Neck          No           1.58           N/A           N/A
                                    (Hand/Wrist/Ankle)
Note(s):
Second Repeated Measurement is not required since the ratio of the largest to smallest SAR for the original and first repeated
measurement is not > 1.20.

Next to Mouth
 Frequency                                                                Repeated      Highest       Repeated     Largest to
    Band         Air Interface   RF Exposure Conditions   Test Position     SAR      Measured SAR   Measured SAR    Smallest
   (MHz)                                                                  (Yes/No)      (W/kg)         (W/kg)      SAR Ratio
    850          CDMA BC0             Next to Mouth           Flat          No          0.324           N/A           N/A
    1900         CDMA BC1             Next to Mouth           Flat          No          0.542           N/A           N/A
Note(s):
Second Repeated Measurement is not required since the ratio of the largest to smallest SAR for the original and first repeated
measurement is not > 1.20.




                                                   Page 22 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                          Issue Date: 9/28/2015

12.     Simultaneous Transmission SAR Analysis
Simultaneous Transmission Condition
   RF Exposure Condition              Item           Capable Transmit Configurations
         Next to Mouth                 1             CDMA              +             DTS
                                       2             CDMA              +             DTS
              Extremity
                                       3             CDMA              +              BT
Notes:
      1. CDMA (BC0/BC1) only
      2. Not support Wi-Fi Hotspot and Wi-Fi Direct
      3. Not support VoIP
      4. Bluetooth and Wi-Fi can not transmit simultabeously

12.1. Sum of the SAR for WWAN & Wi-Fi & BT
Extremity
                                                                  ①+②                  ①+③
    RF                                                         WWAN + DTS            WWAN + BT
                 Test         ①            ②        ③
 Exposure                                                    ∑ 10-g                ∑ 10-g
                Position     WWAN          DTS      BT               SPLSR                 SPLSR
 conditions                                                   SAR                   SAR
                                                                    (Yes/ No)             (Yes/ No)
                                                            (mW/g)                (mW/g)
 Extremity       Neck        2.374      0.084      0.134     2.458     No          2.508     No

Next to Mouth
                                                                   ①+②                 ①+③
                                                                WWAN + DTS           WWAN + BT
 RF Exposure       Test        ①             ②       ③
                                                              ∑ 10-g               ∑ 10-g
  conditions      Position    WWAN           DTS     BT               SPLSR                SPLSR
                                                               SAR                  SAR
                                                                     (Yes/ No)            (Yes/ No)
                                                             (mW/g)               (mW/g)
Next To Mouth       Flat      0.594        0.105    0.167     0.699     No         0.761     No
Conclusion:
Simultaneous transmission SAR measurement (Volume Scan) is not required because the either sum of the 1-g SAR is < 1.6
W/kg or the SPLSR is ≤ 0.04 for all circumstances that require SPLSR calculation.




                                                   Page 23 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21554-S1V1                                                                        Issue Date: 9/28/2015

Appendixes
Refer to separated files for the following appendixes.

15I21554-S1V1 SAR_App A Photos & Ant. Locations

15I21554-S1V1 SAR_App B System Check Plots

15I21554-S1V1 SAR_App C SAR Highest SAR Test Plots

15I21554-S1V1 SAR_App D Tissue Ingredients

15I21554-S1V1 SAR_App E Probe Cal. Certificates

15I21554-S1V1 SAR_App F Dipole Cal. Certificates



                                                END OF REPORT




                                                   Page 24 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.



Document Created: 2015-09-28 11:19:09
Document Modified: 2015-09-28 11:19:09

© 2025 FCC.report