Test Report_SAR

FCC ID: ZNFVC200

RF Exposure Info

Download: PDF
FCCID_2710943

       SAR EVALUATION REPORT



          FCC 47 CFR § 2.1093
           IEEE Std 1528-2013

                 For
    CDMA/BT/BLE & WLAN b/g WATCH

          FCC ID: ZNFVC200
 Model Name: LG-VC200, LGVC200, VC200


       Report Number: 15I21066-S1
          Issue Date: 7/27/2015

              Prepared for
LG ELECTRONICS MOBILECOMM U.S.A., INC.
         1000 SYLVAN AVENUE
 ENGLEWOOD CLIFFS, NEW JERSEY 07632

              Prepared by
    UL VERIFICATION SERVICES INC.
        47173 BENICIA STREET
      FREMONT, CA 94538, U.S.A.
          TEL: (510) 771-1000
          FAX: (510) 661-0888




         NVLAP LAB CODE 200065-0


Report No.: 15I21066-S1                                                                          Issue Date: 7/27/2015

Revision History
 Rev.    Date             Revisions                                                        Revised By
 --      7/27/2015        Initial Issue                                                    --




                                                    Page 2 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21066-S1                                                                                                         Issue Date: 7/27/2015

                                                                 Table of Contents

1.          Attestation of Test Results ......................................................................................................... 5

2.          Test Specification, Methods and Procedures............................................................................ 6

3.          Facilities and Accreditation ........................................................................................................ 6

4.          SAR Measurement System & Test Equipment .......................................................................... 7
     4.1.      SAR Measurement System ........................................................................................................ 7
     4.2.      SAR Scan Procedures ............................................................................................................... 8
     4.3.      Test Equipment........................................................................................................................ 10

5.          Measurement Uncertainty ......................................................................................................... 10

6.          Device Under Test (DUT) Information ...................................................................................... 11
     6.1.      DUT Description ...................................................................................................................... 11
     6.2.      Wireless Technologies ............................................................................................................. 11
     6.3.      Nominal and Maximum Output Power...................................................................................... 11

7.          RF Exposure Conditions (Test Configurations) ...................................................................... 12

8.          Dielectric Property Measurements & System Check .............................................................. 12
     8.1.      Dielectric Property Measurements ........................................................................................... 12
     8.2.      System Check.......................................................................................................................... 14

9.          Conducted Output Power Measurements................................................................................ 16
     9.1.      CDMA ...................................................................................................................................... 16
     9.2.      Wi-Fi 2.4GHz (DTS Band) ....................................................................................................... 16
     9.3.      Bluetooth ................................................................................................................................. 16

10.         Measured and Reported (Scaled) SAR Results ....................................................................... 17
     10.1.        CDMA BC0........................................................................................................................... 17
     10.2.        CDMA BC1........................................................................................................................... 17
     10.3.        Wi-Fi (DTS Band) and Bluetooth .......................................................................................... 18

11.         SAR Measurement Variability ................................................................................................... 20

12.         Simultaneous Transmission SAR Analysis ............................................................................. 21
     12.1.        Sum of the SAR for WWAN & Wi-Fi & BT............................................................................. 21

Appendixes .......................................................................................................................................... 22
     A_15I21066v0 SAR Photos & Ant. Locations ..................................................................................... 22
     B_15I21066v0 SAR System Check Plots ........................................................................................... 22
     C_15I21066v0 SAR Highest Test Plots .............................................................................................. 22
     D_15I21066v0 SAR Tissue Ingredients .............................................................................................. 22
                                                    Page 3 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21066-S1                                                                                      Issue Date: 7/27/2015
  E_15I21066v0 SAR Probe Cal. Certificates ........................................................................................ 22
  F_15I21066v0 SAR Dipole Cal. Certificates ....................................................................................... 22




                                                    Page 4 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21066-S1                                                                          Issue Date: 7/27/2015

1. Attestation of Test Results
Applicant Name                     LG ELECTRONICS MOBILECOMM U.S.A., INC.
FCC ID                             ZNFVC200
Model Name                         LG-VC200, LGVC200, VC200
                                   FCC 47 CFR § 2.1093
Applicable Standards               Published RF exposure KDB procedures
                                   IEEE Std 1528-2013
                                                  SAR Limits (W/Kg)
                                                                              Extremities (hands, wrists, ankles, etc.)
      Exposure Category               Peak spatial-average(1g of tissue)
                                                                                           (10g of tissue)
      General population /
                                                      1.6                                         4
     Uncontrolled exposure
                                          The Highest Reported SAR (W/kg)
                                                                   Equipment Class
RF Exposure Conditions
                                        Licensed                DTS                  U-NII              DSS (BT)
Extremity                                 2.937
                                                                N/A                                        N/A
Next To Mouth                             1.142
                                                                                      N/A
Simultaneous      Extremity               3.071                3.021                                      3.071
Tx                Next To Mouth           1.309                1.247                                      1.309
Date Tested                        6/23/2015 to 6/30/2015
Test Results                       Pass
 UL Verification Services Inc. tested the above equipment in accordance with the requirements set forth in the
 above standards. All indications of Pass/Fail in this report are opinions expressed by UL Verification Services Inc.
 based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into
 account and are published for informational purposes only. The test results show that the equipment tested is
 capable of demonstrating compliance with the requirements as documented in this report.
Note: The results documented in this report apply only to the tested sample, under the conditions and modes of
operation as described herein. This document may not be altered or revised in any way unless done so by UL
Verification Services Inc. and all revisions are duly noted in the revisions section. Any alteration of this document
not carried out by UL Verification Services Inc. will constitute fraud and shall nullify the document. This report must
not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any agency of
the Federal Government, or any agency of any government (NIST Handbook 150, Annex A). This report is written
to support regulatory compliance of the applicable standards stated above.
Approved & Released By:                                     Prepared By:




Devin Chang                                                 Coltyce Sanders
Senior Engineer                                             Laboratory Engineer
UL Verification Services Inc.                               UL Verification Services Inc.




                                                    Page 5 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21066-S1                                                                          Issue Date: 7/27/2015

2. Test Specification, Methods and Procedures
The tests documented in this report were performed in accordance with FCC 47 CFR § 2.1093, IEEE STD 1528-
2013, the following FCC Published RF exposure KDB procedures:
   o 248227 D01 802.11 Wi-Fi SAR v02
   o 447498 D01 General RF Exposure Guidance v05r02
   o 690783 D01 SAR Listings on Grants v01r03
   o 865664 D01 SAR measurement 100 MHz to 6 GHz v01r03
   o 865664 D02 RF Exposure Reporting v01r01
   o 941225 D01 3G SAR Procedures v03

3. Facilities and Accreditation
The test sites and measurement facilities used to collect data are located at

             47173 Benicia Street                             47266 Benicia Street
                  SAR Lab A                                        SAR Lab 1
                  SAR Lab B                                        SAR Lab 2
                  SAR Lab C                                        SAR Lab 3
                  SAR Lab D                                        SAR Lab 4
                  SAR Lab E                                        SAR Lab 5
                  SAR Lab F
                  SAR Lab G
                  SAR Lab H

UL Verification Services Inc. is accredited by NVLAP, Laboratory Code 200065-0.




                                                    Page 6 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21066-S1                                                                           Issue Date: 7/27/2015

4. SAR Measurement System & Test Equipment
4.1.    SAR Measurement System
The DASY5 system used for performing compliance tests consists of the following items:




   A standard high precision 6-axis robot with controller, teach pendant and software. An arm extension for
    accommodating the data acquisition electronics (DAE).
   An isotropic Field probe optimized and calibrated for the targeted measurement.
   A data acquisition electronics (DAE) which performs the signal amplification, signal multiplexing, AD-
    conversion, offset measurements, mechanical surface detection, collision detection, etc. The unit is battery
    powered with standard or rechargeable batteries. The signal is optically transmitted to the EOC.
   The Electro-optical converter (EOC) performs the conversion from optical to electrical signals for the digital
    communication to the DAE. To use optical surface detection, a special version of the EOC is required. The
    EOC signal is transmitted to the measurement server.
   The function of the measurement server is to perform the time critical tasks such as signal filtering, control of
    the robot operation and fast movement interrupts.
   The Light Beam used is for probe alignment. This improves the (absolute) accuracy of the probe positioning.
   A computer running WinXP or Win7 and the DASY5 software.
   Remote control and teach pendant as well as additional circuitry for robot safety such as warning lamps, etc.
   The phantom, the device holder and other accessories according to the targeted measurement.




                                                    Page 7 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21066-S1                                                                          Issue Date: 7/27/2015

4.2. SAR Scan Procedures
Step 1: Power Reference Measurement
The Power Reference Measurement and Power Drift Measurements are for monitoring the power drift of the device
under test in the batch process. The minimum distance of probe sensors to surface determines the closest
measurement point to phantom surface. The minimum distance of probe sensors to surface is 2.1 mm. This
distance cannot be smaller than the distance of sensor calibration points to probe tip as defined in the probe
properties.

Step 2: Area Scan
The Area Scan is used as a fast scan in two dimensions to find the area of high field values, before doing a fine
measurement around the hot spot. The sophisticated interpolation routines implemented in DASY software can find
the maximum locations even in relatively coarse grids. When an Area Scan has measured all reachable points, it
computes the field maximal found in the scanned area, within a range of the global maximum. The range (in dB) is
specified in the standards for compliance testing. For example, a 2 dB range is required in IEEE Standard 1528
and IEC 62209 standards, whereby 3 dB is a requirement when compliance is assessed in accordance with the
ARIB standard (Japan). If only one Zoom Scan follows the Area Scan, then only the absolute maximum will be
taken as reference. For cases where multiple maximums are detected, the number of Zoom Scans has to be
increased accordingly.
Area Scan Parameters extracted from KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz




                                                    Page 8 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21066-S1                                                                          Issue Date: 7/27/2015
Step 3: Zoom Scan
Zoom Scans are used to assess the peak spatial SAR values within a cubic averaging volume containing 1 g and
10 g of simulated tissue. The Zoom Scan measures points (refer to table below) within a cube whose base faces
are centered on the maxima found in a preceding area scan job within the same procedure. When the
measurement is done, the Zoom Scan evaluates the averaged SAR for 1 g and 10 g and displays these values
next to the job’s label.
Zoom Scan Parameters extracted from KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz




Step 4: Power drift measurement
The Power Drift Measurement measures the field at the same location as the most recent power reference
measurement within the same procedure, and with the same settings. The Power Drift Measurement gives the field
difference in dB from the reading conducted within the last Power Reference Measurement. This allows a user to
monitor the power drift of the device under test within a batch process. The measurement procedure is the same as
Step 1.

Step 5: Z-Scan (FCC only)
The Z Scan measures points along a vertical straight line. The line runs along the Z-axis of a one-dimensional grid.
In order to get a reasonable extrapolation the extrapolated distance should not be larger than the step size in Z-
direction.




                                                    Page 9 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21066-S1                                                                               Issue Date: 7/27/2015

4.3. Test Equipment
The measuring equipment used to perform the tests documented in this report has been calibrated in accordance
with the manufacturers’ recommendations, and is traceable to recognized national standards.
Dielectric Property Measurements
Name of Equipment                           Manufacturer           Type/Model           Serial No.        Cal. Due Date
Network Analyzer                               Agilent               E753ES            MY40000980           4/17/2016
Dielectric Probe kit                           SPEAG                DAK-3.5               1082              9/16/2015
Shorting block                                 SPEAG              DAK-3.5 Short       SM DAK 200 BA            N/A
Thermometer                                Control Company          Traceable           122529163           10/8/2015
System Check
Name of Equipment                           Manufacturer           Type/Model           Serial No.        Cal. Due Date
Synthesized Signal Generator                   Agilent               8665B             3438A00633          7/10/2015
Power Meter                                     HP                   437B              3125U09516          8/27/2015
Power Meter                                     HP                   437B              3125U11347          10/6/2015
Power Sensor                                    HP                   8481A             3318A95392          10/6/2015
Power Sensor                                    HP                   8481A             1926A16917          10/10/2015
Amplifier                                      MITEQ         AMF-4D-00400600-50-30P      1808938              N/A
Bi-directional coupler                     Werlatone, Inc.         C8060-102              2710                N/A
DC Power Supply                                 HP                   6296A            2841A-05955             N/A
E-Field Probe (SAR Lab 1)                     SPEAG                 EX3DV4                3929             4/22/2016
E-Field Probe (SAR Lab 3)                     SPEAG                 EX3DV4                3749             1/26/2016
Data Acquisition Electronics (SAR Lab 1)      SPEAG                  DAE4                 1352             11/7/2015
Data Acquisition Electronics (SAR Lab 3)      SPEAG                  DAE4                 1380             7/23/2015
System Validation Dipole                      SPEAG                 D835V2               4d117             5/18/2016
System Validation Dipole                      SPEAG                 D835V2               4d142              9/9/2015
System Validation Dipole                      SPEAG                 D1900V2              5d163             9/11/2015
Thermometer (SAR Lab 1)                       EXTECH                445703              CCS-205            3/20/2016
Thermometer (SAR Lab 3)                       EXTECH                445703              CCS-237             6/5/2016
Other
Name of Equipment                           Manufacturer           Type/Model           Serial No.        Cal. Due Date
Base Station Simulator                         R&S                  CMW500               135387            4/20/2016


5. Measurement Uncertainty
Per KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz, when the highest measured 1-g SAR within a
frequency band is < 1.5 W/kg, the extensive SAR measurement uncertainty analysis described in IEEE Std 1528-
2013 is not required in SAR reports submitted for equipment approval.




                                                   Page 10 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21066-S1                                                                                                    Issue Date: 7/27/2015

6. Device Under Test (DUT) Information
6.1.     DUT Description
                                 Overall (Length x Width): 56 mm x 41.5 mm
 Device Dimension                Overall Diagonal: 53.8 mm
                                 Display Diagonal: 33 mm
 Back Cover                      The rechargeable battery is not user accessible.
 Battery Options                 The rechargeable battery is not user accessible.
                                 Wi-Fi Hotspot mode permits the device to share its cellular data connection with other Wi-Fi-enabled devices.
 Wireless Router (Hotspot)
                                 Wi-Fi Hotspot mode is NOT SUPPORTED
                                 Wi-Fi Direct enabled devices transfer data directly between each other
 Wi-Fi Direct
                                 Wi-Fi Direct is NOT SUPPORTED
                                           S/N                       IMEI                                          Notes


 Test sample information                 1ZRY4                A1000040E03993                                Conducted Sample

                                         1ZRY3                A1000040E03992                                   SAR Sample


6.2.     Wireless Technologies
       Wireless                                                                                                         Duty Cycle used for SAR
                             Frequency bands                                Operating mode
     technologies                                                                                                               testing
                           BC0
 CDMA (CDMA2000)                                      1xRTT (Voice & Data)                                             100%
                           BC1
                                                      802.11b
 Wi-Fi                     2.4 GHz                                                                                     100%
                                                      802.11g
 Bluetooth                 2.4 GHz                    Version 4.0 LE                                                   77.5% (DH5)

6.3.     Nominal and Maximum Output Power
KDB 447498 sec.4.1.(3) at the maximum rated output power and within the tune-up tolerance range specified for
the product, but not more than 2 dB lower than the maximum tune-up tolerance limit

Upper limit (dB):      -1.5      ~     0.5               Max. RF Output Pow er (dBm)
                                                                                    Max. tune-up
RF Air interface              Mode                       Target
                                                                                    tolerance limit
   CDMA BC0                  1xRTT                        23.7                           24.2
   CDMA BC1                  1xRTT                        21.2                           21.7
Upper limit (dB):                      1.0               Max. RF Output Pow er (dBm)
                                                                                    Max. tune-up
RF Air interface              Mode                       Target
                                                                                    tolerance limit
                             802.11b                       6.0                            7.0
  WiFi 2.4 GHz
                             802.11g                       5.0                           6.0
                 Bluetooth                                 8.0                           9.0
                Bluetooth LE                               7.0                           8.0




                                                   Page 11 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21066-S1                                                                           Issue Date: 7/27/2015

7. RF Exposure Conditions (Test Configurations)
Refer to “SAR Photos and Ant locations” Appendix for the specific details of the antenna-to-antenna and
antenna-to-edge(s) distances.

     Wireless            RF Exposure               DUT-to-User          Test        Antenna-to-          SAR
   technologies           Conditions                Separation         Position    edge/surface        Required
                           Extremity
                                                        0                  Rear       N/A                 Yes
       WLAN            (Hand/Wrist/Ankle)
                        Next to Mouth                  10                  Front      N/A                 Yes

The neck region of the SAM phantom was chosen for wrist-worn extremity SAR testing in accordance with KDB
447498 §6.2.
A non-standard setup was used for SAR testing based on guidance from the FCC. The operational description
contains additional information.

8. Dielectric Property Measurements & System Check
8.1.    Dielectric Property Measurements
The temperature of the tissue-equivalent medium used during measurement must also be within 18C to 25C and
within ± 2C of the temperature when the tissue parameters are characterized.
The dielectric parameters must be measured before the tissue-equivalent medium is used in a series of SAR
measurements. The parameters should be re-measured after each 3 – 4 days of use; or earlier if the dielectric
parameters can become out of tolerance; for example, when the parameters are marginal at the beginning of the
measurement series.
Tissue dielectric parameters were measured at the low, middle and high frequency of each operating frequency
range of the test device.

Tissue Dielectric Parameters
FCC KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz
                                                        Head                                Body
    Target Frequency (MHz)
                                             er                  s (S/m)            er                 s (S/m)
             150                            52.3                  0.76             61.9                 0.80
             300                            45.3                  0.87             58.2                 0.92
             450                            43.5                  0.87             56.7                 0.94
             835                            41.5                  0.90             55.2                 0.97
             900                            41.5                  0.97             55.0                 1.05
             915                            41.5                  0.98             55.0                 1.06
            1450                            40.5                  1.20             54.0                 1.30
            1610                            40.3                  1.29             53.8                 1.40
         1800 – 2000                        40.0                  1.40             53.3                 1.52
            2450                            39.2                  1.80             52.7                 1.95
            3000                            38.5                  2.40             52.0                 2.73
            5000                            36.2                  4.45             49.3                 5.07
            5100                            36.1                  4.55             49.1                 5.18
            5200                            36.0                  4.66             49.0                 5.30
            5300                            35.9                  4.76             48.9                 5.42
            5400                            35.8                  4.86             48.7                 5.53
            5500                            35.6                  4.96             48.6                 5.65
            5600                            35.5                  5.07             48.5                 5.77
            5700                            35.4                  5.17             48.3                 5.88
            5800                            35.3                  5.27             48.2                 6.00

IEEE Std 1528-2013
Refer to Table 3 within the IEEE Std 1528-2013




                                                   Page 12 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21066-S1                                                                                   Issue Date: 7/27/2015
Dielectric Property Measurements Results:

SAR Lab 1
     Date       Freq. (MHz)                  Liquid Parameters                       Measured   Target   Delta (%)   Limit ±(%)
                              e'   53.2800             Relative Permittivity (єr):    53.28     55.20      -3.48         5
                Body 835
                              e"   21.4600                     Conductivity (σ):       1.00     0.97       2.72          5
                              e'   53.4000             Relative Permittivity (єr):    53.40     55.28      -3.40         5
   6/24/2015    Body 820
                              e"   21.5900                     Conductivity (σ):       0.98     0.97       1.64          5
                              e'   53.0600             Relative Permittivity (єr):    53.06     55.16      -3.80         5
                Body 850
                              e"   21.5400                       Conductivity (σ):     1.02     0.99       3.13          5


SAR Lab 3
     Date       Freq. (MHz)                  Liquid Parameters                       Measured   Target   Delta (%)   Limit ±(%)
                              e'   38.4800             Relative Permittivity (єr):    38.48     40.00      -3.80         5
                Head 1900
                              e"   13.0500                     Conductivity (σ):       1.38     1.40       -1.52         5
                              e'   38.6800             Relative Permittivity (єr):    38.68     40.00      -3.30         5
   6/22/2015    Head 1850
                              e"   13.0000                     Conductivity (σ):       1.34     1.40       -4.48         5
                              e'   38.4500             Relative Permittivity (єr):    38.45     40.00      -3.87         5
                Head 1910
                              e"   13.0200                     Conductivity (σ):       1.38     1.40       -1.23         5
                              e'   51.8300             Relative Permittivity (єr):    51.83     53.30      -2.76         5
                Body 1900
                              e"   14.4600                     Conductivity (σ):       1.53     1.52       0.50          5
                              e'   51.9100             Relative Permittivity (єr):    51.91     53.30      -2.61         5
   6/23/2015    Body 1850
                              e"   14.2200                     Conductivity (σ):       1.46     1.52       -3.77         5
                              e'   51.8900             Relative Permittivity (єr):    51.89     53.30      -2.65         5
                Body 1910
                              e"   14.5400                     Conductivity (σ):       1.54     1.52       1.59          5
                              e'   43.0400             Relative Permittivity (єr):    43.04     41.50      3.71          5
                Head 835
                              e"   19.9200                     Conductivity (σ):       0.92     0.90       2.76          5
                              e'   43.2500             Relative Permittivity (єr):    43.25     41.60      3.96          5
   6/24/2015    Head 820
                              e"   20.0100                     Conductivity (σ):       0.91     0.90       1.55          5
                              e'   42.7500             Relative Permittivity (єr):    42.75     41.50      3.01          5
                Head 850
                              e"   19.8700                     Conductivity (σ):       0.94     0.92       2.63          5
                              e'   39.3600             Relative Permittivity (єr):    39.36     40.00      -1.60         5
                Head 1900
                              e"   13.4000                     Conductivity (σ):       1.42     1.40       1.12          5
                              e'   39.5900             Relative Permittivity (єr):    39.59     40.00      -1.02         5
   6/26/2014    Head 1850
                              e"   13.2900                     Conductivity (σ):       1.37     1.40       -2.35         5
                              e'   39.3100             Relative Permittivity (єr):    39.31     40.00      -1.72         5
                Head 1910
                              e"   13.4100                     Conductivity (σ):       1.42     1.40       1.73          5
                              e'   52.8000             Relative Permittivity (єr):    52.80     55.20      -4.35         5
                Body 835
                              e"   21.8800                     Conductivity (σ):       1.02     0.97       4.73          5
                              e'   52.9700             Relative Permittivity (єr):    52.97     55.28      -4.17         5
   6/30/2015    Body 820
                              e"   21.9400                     Conductivity (σ):       1.00     0.97       3.29          5
                              e'   52.8900             Relative Permittivity (єr):    52.89     55.16      -4.11         5
                Body 850
                              e"   21.8700                       Conductivity (σ):     1.03     0.99       4.71          5




                                                   Page 13 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21066-S1                                                                          Issue Date: 7/27/2015

8.2.    System Check
SAR system verification is required to confirm measurement accuracy, according to the tissue dielectric media,
probe calibration points and other system operating parameters required for measuring the SAR of a test device.
The system verification must be performed for each frequency band and within the valid range of each probe
calibration point required for testing the device. The same SAR probe(s) and tissue-equivalent media combinations
used with each specific SAR system for system verification must be used for device testing. When multiple probe
calibration points are required to cover substantially large transmission bands, independent system verifications are
required for each probe calibration point. A system verification must be performed before each series of SAR
measurements using the same probe calibration point and tissue-equivalent medium. Additional system verification
should be considered according to the conditions of the tissue-equivalent medium and measured tissue dielectric
parameters, typically every three to four days when the liquid parameters are re-measured or sooner when
marginal liquid parameters are used at the beginning of a series of measurements.

System Performance Check Measurement Conditions:
   The measurements were performed in the flat section of the TWIN SAM or ELI phantom, shell thickness: 2.0
    ±0.2 mm (bottom plate) filled with Body or Head simulating liquid of the following parameters.
   The depth of tissue-equivalent liquid in a phantom must be ≥ 15.0 cm for SAR measurements ≤ 3 GHz and ≥
    10.0 cm for measurements > 3 GHz.
   The DASY system with an E-Field Probe was used for the measurements.
   The dipole was mounted on the small tripod so that the dipole feed point was positioned below the center
    marking of the flat phantom section and the dipole was oriented parallel to the body axis (the long side of the
    phantom). The standard measuring distance was 10 mm (above 1 GHz) and 15 mm (below 1 GHz) from dipole
    center to the simulating liquid surface.
   The coarse grid with a grid spacing of 15 mm was aligned with the dipole.
    For 5 GHz band - The coarse grid with a grid spacing of 10 mm was aligned with the dipole.
   Special 7x7x7 (below 3 GHz) and/or 8x8x7 (above 3 GHz) fine cube was chosen for the cube.
   Distance between probe sensors and phantom surface was set to 3 mm.
    For 5 GHz band - Distance between probe sensors and phantom surface was set to 2.5 mm
   The dipole input power (forward power) was 100 mW.
   The results are normalized to 1 W input power.




                                                   Page 14 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21066-S1                                                                                         Issue Date: 7/27/2015
Reference Target SAR Values
The reference SAR values can be obtained from the calibration certificate of system validation dipoles
                                                                                             Target SAR Values (W/kg)
  System Dipole        Serial No.            Cal. Date        Freq. (MHz)
                                                                                    1g/10g           Head                  Body
                                                                                      1g              9.08                 9.38
    D835V2                4d117              5/18/2015             835
                                                                                     10g              5.93                 6.20
                                                                                      1g              8.91                 9.22
    D835V2                4d142              9/9/2014              835
                                                                                     10g              5.77                 6.05
                                                                                      1g              40.8                 40.6
    D1900V2               5d163              9/11/2014             1900
                                                                                     10g              21.2                 21.4

System Check Results
The 1-g and 10-g SAR measured with a reference dipole, using the required tissue-equivalent medium at the test
frequency, must be within 10% of the manufacturer calibrated dipole SAR target.

SAR Lab 1
                     System Dipole                                        Measured Results
                                                     T.S.                                          Target         Delta
 Date Tested                                                       Zoom Scan to     Normalize                                 Plot No.
                   Type           Serial #          Liquid                                       (Ref. Value)     ±10 %
                                                                     100 mW          to 1 W
                                                             1g           1.02        10.2          9.38           8.74
  6/24/2015       D835V2          4d117           Body                                                                            1,2
                                                             10g          0.68         6.8           6.2           8.87


SAR Lab 3
                     System Dipole                                        Measured Results
                                                     T.S.                                          Target         Delta
 Date Tested                                                       Zoom Scan to     Normalize                                 Plot No.
                   Type           Serial #          Liquid                                       (Ref. Value)     ±10 %
                                                                     100 mW          to 1 W
                                                             1g           4.00        40.0          40.8           -1.96
  6/22/2015       D1900V2         5d163          Head
                                                             10g          2.07        20.7          21.2           -2.36
                                                             1g           4.17        41.7          40.60          2.71
  6/23/2015       D1900V2         5d163           Body                                                                            3,4
                                                             10g          2.16        21.6          21.4           0.93
                                                             1g           0.97         9.7          9.08           6.94
  6/24/2015       D835V2          4d117          Head                                                                             5,6
                                                             10g          0.64         6.4          5.93           7.76
                                                             1g           3.91        39.1          40.8           -4.17
  6/26/2015       D1900V2         5d163          Head                                                                             7,8
                                                             10g          2.02        20.2          21.2           -4.72
                                                             1g           0.88         8.8          9.22           -4.12
  6/30/2015       D835V2          4d142           Body                                                                            9,10
                                                             10g          0.59         5.9          6.05           -3.14




                                                   Page 15 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21066-S1                                                                           Issue Date: 7/27/2015

9. Conducted Output Power Measurements
9.1.    CDMA
CDMA BC0 Measured Results
                                                                              Freq.      Max. Pwr
    Band                          Mode                          Ch No.
                                                                             (MHz)        (dBm)
                                                                 1013       824.70         23.5
                                      RC1 SO55
                                                                  384       836.52         23.7
                                      (Loopback)
                                                                  777       848.31         23.6
                                                                 1013       824.70         23.3
                                      RC3 SO55
    BC 0        1xRTT                                             384       836.52         23.5
                                      (Loopback)
                                                                 777        848.31         23.7
                                                                 1013       824.70         23.4
                                      RC3 SO32
                                                                 384        836.52         23.5
                                      (+F-SCH)
                                                                 777        848.31         23.4

CDMA BC1 Measured Results
                                                                              Freq.      Max. Pwr
    Band                          Mode                          Ch No.
                                                                             (MHz)        (dBm)
                                                                 25         1851.25        21.2
                                      RC1 SO55
                                                                 600        1880.00        21.4
                                      (Loopback)
                                                                 1175       1908.75        21.5
                                                                  25        1851.25        21.5
                                      RC3 SO55
    BC 1        1xRTT                                             600       1880.00        21.3
                                      (Loopback)
                                                                 1175       1908.75        21.4
                                                                  25        1851.25        21.4
                                      RC3 SO32
                                                                 600        1880.00        21.4
                                      (+F-SCH)
                                                                 1175       1908.75        21.5

9.2.    Wi-Fi 2.4GHz (DTS Band)
Maximum tune-up tolerance limit is 7.00 dBm. This power level qualifies for exclusion of SAR testing. Please refer
to Section 10.3 for further details.

9.3.    Bluetooth
Maximum tune-up tolerance limit is 9.00 dBm. This power level qualifies for exclusion of SAR testing. Please refer
to Section 10.3 for further details.




                                                   Page 16 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21066-S1                                                                                         Issue Date: 7/27/2015

10.       Measured and Reported (Scaled) SAR Results
SAR Test Reduction criteria are as follows:

KDB 447498 D01 General RF Exposure Guidance:
Testing of other required channels within the operating mode of a frequency band is not required when the reported 1-g or 10-g
SAR for the mid-band or highest output power channel is:
   ≤ 0.8 W/kg or 2.0 W/kg, for 1-g or 10-g respectively, when the transmission band is ≤ 100 MHz
   ≤ 0.6 W/kg or 1.5 W/kg, for 1-g or 10-g respectively, when the transmission band is between 100 MHz and 200 MHz
   ≤ 0.4 W/kg or 1.0 W/kg, for 1-g or 10-g respectively, when the transmission band is ≥ 200 MHz

KDB 941225 D01 SAR test for 3G devices:
When the maximum output power and tune-up tolerance specified for production units in a secondary mode is ≤ ¼ dB higher
than the primary mode or when the highest reported SAR of the primary mode is scaled by the ratio of specified maximum
output power and tune-up tolerance of secondary to primary mode and the adjusted SAR is ≤ 1.2 W/kg, SAR measurement is
not required for the secondary mode


10.1. CDMA BC0
                                                                               Power (dBm)     1-g SAR (W/kg)   10-g SAR (W/kg)
   RF Exposure                      Dist.                            Freq.                                                        Plot
                        Mode                Test Position   Ch #.            Tune-up
    Conditions                     (mm)                             (MHz)              Meas.   Meas.   Scaled   Meas.    Scaled   No.
                                                                               limit
                                                            1013    824.7     24.2     23.4                     2.000    2.405
                        1xRTT
      Extremity                      0         Neck         384     836.5     24.2     23.5                     2.500    2.937     1
                      (RC3 SO32)
                                                            777     848.3     24.2     23.4                     1.570    1.888
                                                            1013    824.7     24.2     23.3    0.778    0.957
                        1xRTT
  Next - to - Mouth                 10          Flat        384     836.5     24.2     23.5    0.972    1.142                      2
                      (RC3 SO55)
                                                            777     848.3     24.2     23.7    0.727    0.816


10.2. CDMA BC1
                                                                               Power (dBm)     1-g SAR (W/kg)   10-g SAR (W/kg)
   RF Exposure                      Dist.                            Freq.                                                        Plot
                        Mode                Test Position   Ch #.            Tune-up
    Conditions                     (mm)                             (MHz)              Meas.   Meas.   Scaled   Meas.    Scaled   No.
                                                                               limit
                        1xRTT
      Extremity                      0         Neck         600     1880.0    21.7     21.4                     1.520    1.629     3
                      (RC3 SO32)
                        1xRTT
  Next - to - Mouth                 10          Flat        600     1880.0    21.7     21.3    0.614    0.673                      4
                      (RC3 SO55)




                                                   Page 17 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21066-S1                                                                                    Issue Date: 7/27/2015

10.3. Wi-Fi (DTS Band) and Bluetooth
Standalone SAR Test Exclusion Considerations & Estimated SAR
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)]·[√f(GHz)] ≤ 3.0, for 1-g SAR
and ≤ 7.5 for 10-g extremity SAR, where
        f(GHz) is the RF channel transmit frequency in GHz
        Power and distance are rounded to the nearest mW and mm before calculation
        The result is rounded to one decimal place for comparison
The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a
distance of 5 mm is applied to determine SAR test exclusion.

When the standalone SAR test exclusion is applied to an antenna that transmits simultaneously with other
antennas, the standalone SAR must be estimated according to following to determine simultaneous transmission
SAR test exclusion:
        (max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)]·[√f(GHz)/x] W/kg for test
         separation distances ≤ 50 mm;
                  where x = 7.5 for 1-g SAR, and x = 18.75 for 10-g SAR.
        0.4 W/kg for 1-g SAR and 1.0 W/kg for 10-g SAR, when the test separation distances is > 50 mm.


Extremity Exposure Conditions:

WLAN
  Max. tune-up tolerance limit          Min. test         Frequency          SAR test            Test             Estimated
                                       separation           (GHz)            exclusion       Configuration        10-g SAR
     (dBm)              (mW)         distance (mm)                            Result*                              (W/kg)
    7.0                   5                  5                2.462              1.6              Neck               0.084
Conclusion:
*: The computed value is < 7.5; therefore, Wi-Fi 2.4GHz qualifies for Extremity SAR test exclusion.

Bluetooth
  Max. tune-up tolerance limit          Min. test         Frequency          SAR test            Test             Estimated
                                       separation           (GHz)            exclusion       Configuration        10-g SAR
     (dBm)              (mW)         distance (mm)                            Result*                              (W/kg)
    9.0                   8                  5                2.480              2.5              Neck              0.134
Conclusion:
*: The computed value is < 7.5; therefore, Bluetooth qualifies for Standalone SAR test exclusion.




                                                   Page 18 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21066-S1                                                                          Issue Date: 7/27/2015
Next to Mouth Exposure Conditions:

WLAN
  Max. tune-up tolerance limit       Min. test      Frequency         SAR test          Test           Estimated
                                    separation        (GHz)           exclusion     Configuration      1-g SAR
     (dBm)            (mW)        distance (mm)                        Result*                          (W/kg)
    7.0                 5               10             2.462             0.8              Flat           0.105
Conclusion:
*: The computed value is < 3; therefore, Wi-Fi 2.4GHz qualifies for Next to Mouth SAR test exclusion.

Bluetooth
  Max. tune-up tolerance limit       Min. test      Frequency         SAR test          Test           Estimated
                                    separation        (GHz)           exclusion     Configuration      1-g SAR
     (dBm)            (mW)        distance (mm)                        Result*                          (W/kg)
    9.0                 8               10             2.462             1.3              Flat           0.167
Conclusion:
*: The computed value is < 3; therefore, Wi-Fi 2.4GHz qualifies for Next to Mouth SAR test exclusion.




                                                   Page 19 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21066-S1                                                                                  Issue Date: 7/27/2015

11.        SAR Measurement Variability
In accordance with published RF Exposure KDB 865664 D01 SAR measurement 100 MHz to 6 GHz. These
additional measurements are repeated after the completion of all measurements requiring the same head or body
tissue-equivalent medium in a frequency band. The test device should be returned to ambient conditions (normal
room temperature) with the battery fully charged before it is re-mounted on the device holder for the repeated
measurement(s) to minimize any unexpected variations in the repeated results.

1) Repeated measurement is not required when the original highest measured SAR is < 0.80 W/kg; steps 2)
   through 4) do not apply.
2) When the original highest measured SAR is ≥ 0.80 W/kg, repeat that measurement once.
3) Perform a second repeated measurement only if the ratio of largest to smallest SAR for the original and first
   repeated measurements is > 1.20 or when the original or repeated measurement is ≥ 1.45 W/kg (~ 10% from
   the 1-g SAR limit).
4) Perform a third repeated measurement only if the original, first or second repeated measurement is ≥1.5 W/kg
   and the ratio of largest to smallest SAR for the original, first and second repeated measurements is > 1.20.

Extremity
 Frequency                                                                Repeated      Highest       Repeated     Largest to
    Band         Air Interface   RF Exposure Conditions   Test Position     SAR      Measured SAR   Measured SAR    Smallest
   (MHz)                                                                  (Yes/No)      (W/kg)         (W/kg)      SAR Ratio
                                        Extremity
    850          CDMA BC0                                     Neck          Yes          2.50           2.20          1.14
                                    (Hand/Wrist/Ankle)
                                        Extremity
    1900         CDMA BC1                                     Neck          No           1.52           N/A           1.00
                                    (Hand/Wrist/Ankle)
Note(s):
Second Repeated Measurement is not required since the ratio of the largest to smallest SAR for the original and first repeated
measurement is not > 1.20.

Next to Mouth
 Frequency                                                                Repeated      Highest       Repeated     Largest to
    Band         Air Interface   RF Exposure Conditions   Test Position     SAR      Measured SAR   Measured SAR    Smallest
   (MHz)                                                                  (Yes/No)      (W/kg)         (W/kg)      SAR Ratio
    850          CDMA BC0             Next to Mouth           Flat          Yes         0.972          0.948          1.03
    1900         CDMA BC1             Next to Mouth           Flat          No           0.04           N/A           N/A
Note(s):
Second Repeated Measurement is not required since the ratio of the largest to smallest SAR for the original and first repeated
measurement is not > 1.20.




                                                   Page 20 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21066-S1                                                                            Issue Date: 7/27/2015

12.     Simultaneous Transmission SAR Analysis
Simultaneous Transmission Condition
   RF Exposure Condition              Item           Capable Transmit Configurations
         Next to Mouth                 1             CDMA              +             DTS
                                       2             CDMA              +             DTS
              Extremity
                                       3             CDMA              +              BT
Notes:
      1. 1x CDMA (BC0/BC1) only
      2. Not support Wi-Fi Hotspot and Wi-Fi Direct
      3. Not support VoIP
      4. Bluetooth and Wi-Fi can not transmit simultabeously

12.1. Sum of the SAR for WWAN & Wi-Fi & BT
Extremity
                                                                  ①+②                  ①+③
    RF                                                         WWAN + DTS            WWAN + BT
                 Test         ①            ②        ③
 Exposure                                                    ∑ 10-g                ∑ 10-g
                Position     WWAN          DTS      BT               SPLSR                 SPLSR
 conditions                                                   SAR                   SAR
                                                                    (Yes/ No)             (Yes/ No)
                                                            (mW/g)                (mW/g)
 Extremity       Neck        2.937      0.084      0.134     3.021     No          3.071     No
Conclusion:
Simultaneous transmission SAR measurement (Volume Scan) is not required because the either sum of the 10-g SAR is < 4.0
W/kg or the SPLSR is ≤ 0.04 for all circumstances that require SPLSR calculation.

Next to Mouth
                                                                   ①+②                 ①+③
                                                                WWAN + DTS           WWAN + BT
 RF Exposure       Test        ①             ②       ③
                                                              ∑ 10-g               ∑ 10-g
  conditions      Position    WWAN           DTS     BT               SPLSR                SPLSR
                                                               SAR                  SAR
                                                                     (Yes/ No)            (Yes/ No)
                                                             (mW/g)               (mW/g)
Next To Mouth       Flat      1.142        0.105    0.167     1.247     No         1.309     No
Conclusion:
Simultaneous transmission SAR measurement (Volume Scan) is not required because the either sum of the 1-g SAR is < 1.6
W/kg or the SPLSR is ≤ 0.04 for all circumstances that require SPLSR calculation.




                                                   Page 21 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.: 15I21066-S1                                                                          Issue Date: 7/27/2015

Appendixes
Refer to separated files for the following appendixes.

A_15I21066v0 SAR Photos & Ant. Locations

B_15I21066v0 SAR System Check Plots

C_15I21066v0 SAR Highest Test Plots

D_15I21066v0 SAR Tissue Ingredients

E_15I21066v0 SAR Probe Cal. Certificates

F_15I21066v0 SAR Dipole Cal. Certificates



                                                END OF REPORT




                                                   Page 22 of 22
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.



Document Created: 2015-07-28 08:47:09
Document Modified: 2015-07-28 08:47:09

© 2025 FCC.report