HAC RF Appendix_F

FCC ID: ZNFUS991

Test Report

Download: PDF
FCCID_2599714

Calibration Laboratory of                                         SS /¥                                            S   Schweizerischer Kalibrierdienst
          «                                                      S                    Lo
Schmid & Partner                                                 ii\ ww 2                                          .   Service suisse d‘étalonnage
  Englneenng AG                                                  Tzul y                                            5   Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                     ‘z,///;_\\\\?                                         Swiss Calibration Service
                                                                      /l’IH|I\\“\\\


Accredited by the Swiss Accreditation Service (SAS)                                                                Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client        UL CCS USA                                                                                Certificate No: CD835V3—101 4_Feb1 5


CALIBRATION CERTIFICATE
 Object                                CD835V3 — SN: 1014


 Calibration procedure(s)              QA CAL—20.v6
                                       Calibration procedure for dipoles in air



 Calibration date:                     February 18, 2015




 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (S1).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.

 Calibration Equipment used (M&TE critical for calibration)
 Primary Standards                       ID #                        Cal Date (Certificate No.)                             Scheduled Calibration
 Power meter EPM—442A                    GB37480704                  07—Oct—14 (No. 217—02020)                              Oct—15
 Power sensor HP 8481A                   US37292783                  07—Oct—14 (No. 217—02020)                              Oct—15
  Power sensor HP 8481A                  MY41092317                  07—Oct—14 (No. 217—02021)                              Oct—15
  Reference 10 dB Attenuator             SN: 5047.2 / 06327          03—Apr—14 (No. 217—01921)                              Apr—15
  Probe ER3SDV6                          SN: 2336                    31—Dec—14 (No. ER3—2336_Dec14)                          Dec—15
  Probe H3DV6                            SN: 6065                    31—Dec—14 (No. H3—6065_Dec14)                           Dec—15
  DAE4                                   SN: 781                     12—Sep—14 (No. DAE4—781_Sep14)                          Sep—15


  Secondary Standards                    ID #                        Check Date (in house)                                   Scheduled Check
  Power meter Agilent 4419B              SN: GB42420191              09—Oct—09 (in house check Sep—14)                       in house check: Sep—16
  Power sensor HP E4412A                 SN: US38485102              O5—Jan—10 (in house check Sep—14)                       In house check: Sep—16
  Power sensor HP 8482A                  SN: US37295597              09—Oct—09 (in house check Sep—14)                       In house check: Sep—16
  Network Analyzer HP 8753E              US37390585                  18—Oct—01 (in house check Oct—14)                       In house check: Oct—15
  RF generator R&S SM1T—06               SN: 832283/011              27—Aug—12 (in house check Oct—13)                       In house check: Oct—16


                                         Name                                              Function                          Signature
  Calibrated by:                         Leif Klysner                                      Laboratory Technician



  Approved by:                           Fin Bomholt                                       Deputy Technical Manager               3      / %
                                                                                                                        f’ ze 2’/’/

                                                                                                                            Issued: February 19, 2015
  This calibration certificate shall not be reproduced except in full without written approval of the laboratory.


Certificate No: CD835V3—1014_Feb15                           Page 1 of 5


Calibration Laboratery of                                                                       Schweizerischer Kalibrierdienst
Schmid & Partner                                                                                Service suisse d‘étalonnage
  Engineering AG                                                                                Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                    Swiss Calibration Service

Accredited by the Swiss Accreditation Service (SAS)                                         Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates


References
[1]       ANSI—C63.19—2011
          American National Standard, Methods of Measurement of Compatibility between Wireless Communications
          Devices and Hearing Aids.
Methods Applied and Interpretation of Parameters:
      *   Coordinate System: y—axis is in the direction of the dipole arms. z—axis is from the basis of the antenna
          (mounted on the table) towards its feed point between the two dipole arms. x—axis is normal to the other axes.
          In coincidence with the standards [1], the measurement planes (probe sensor center) are selected to be at a
          distance of 15 mm above the top metal edge of the dipole arms.
      e   Measurement Conditions: Further details are available from the hardcopies at the end of the certificate. All
          figures stated in the certificate are valid at the frequency indicated. The forward power to the dipole connector
          is set with a calibrated power meter connected and monitored with an auxiliary power meter connected to a
          directional coupler. While the dipole under test is connected, the forward power is adjusted to the same level.
      «   Antenna Positioning: The dipole is mounted on a HAC Test Arch phantom using the matching dipole
          positioner with the arms horizontal and the feeding cable coming from the floor. The measurements are
          performed in a shielded room with absorbers around the setup to reduce the reflections.
          It is verified before the mounting of the dipole under the Test Arch phantom, that its arms are perfectly in a
          line. It is installed on the HAC dipole positioner with its arms parallel below the dielectric reference wire and
          able to move elastically in vertical direction without changing its relative position to the top center of the Test
          Arch phantom. The vertical distance to the probe is adjusted after dipole mounting with a DASYS Surface
          Check job. Before the measurement, the distance between phantom surface and probe tip is verified. The
          proper measurement distance is selected by choosing the matching section of the HAC Test Arch phantom
          with the proper device reference point (upper surface of the dipole) and the matching grid reference point (tip
          of the probe) considering the probe sensor offset. The vertical distance to the probe is essential for the
          accuracy.
      e   Feed Point Impedance and Return Loss: These parameters are measured using a HP 8753E Vector Network
          Analyzer. The impedance is specified at the SMA connector of the dipole. The influence of reflections was
          eliminating by applying the averaging function while moving the dipole in the air, at least 70cm away from any
          obstacles.

      *   E—field distribution: E field is measured in the x—y—plane with an isotropic ER3D—field probe with 100 mW
          forward power to the antenna feed point. In accordance with [1], the scan area is 20mm wide, its length
          exceeds the dipole arm length (180 or 9O0mm). The sensor center is 15 mm (in z) above the metal top of the
          dipole arms. Two 3D maxima are available near the end of the dipole arms. Assuming the dipole arms are
          perfectly in one line, the average of these two maxima (in subgrid 2 and subgrid 8) is determined to
          compensate for any non—parallelity to the measurement plane as well as the sensor displacement. The E—field
          value stated as calibration value represents the maximum of the interpolated 3D—E—field, in the plane above
          the dipole surface.




 The reported uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the
 coverage factor k=2, which for a normal distribution corresponds to a coverage probability of approximately 95%.




Certificate No: CD835V3—1014_Feb15                      Page 2 of 5


Measurement Conditions
   DASY system configuration, as far as not given on page 1.
     DASY Version                                               DASY5                         V52.8.8
     Phantom                                                HAC Test Arch
     Distance Dipole Top — Probe Center                         15mm
     Scan resolution                                        dx, dy = 5 mm
     Frequency                                          835 MHz + 1 MHz
     Input power drift                                         <0.05 dB


Maximum Field values at 835 MHz

     E—field 15 mm above dipole surface                           condition           Interpolated maximum
     Maximum measured above high end                         100 mW input power       106.4 V/m = 40.54 dBV/m
     Maximum measured above low end                          100 mW input power       106.4 V/m = 40.54 dBV/m
     Averaged maximum above arm                              100 mW input power       106.4 V/im + 12.8 % (k=2)



Appendix (Additional assessments outside the scope of SCS0108)

Antenna Parameters

     Frequency                                                   Return Loss                Impedance

     800 MHz                                                        17.8 dB                43.9 Q — 10.6 jQ
     835 MHz                                                        30.7 dB                50.1 Q + 2.9 jQ
     900 MHz                                                        16.9 dB                53.6 Q — 14.4 jQ
     950 MHz                                                        20.4 dB                43.9 Q + 6.5 jQ
     960 MHz                                                        16.2 dB                49.2 Q + 15.6 jQ



3.2 Antenna Design and Handling

The calibration dipole has a symmetric geometry with a built—in two stub matching network, which leads to the
enhanced bandwidth.
The dipole is built of standard semirigid coaxial cable. The internal matching line is open ended. The antenna is
therefore open for DC signals.
Do not apply force to dipole arms, as they are liable to bend. The soldered connections near the feedpoint may be
damaged. After excessive mechanical stress or overheating, check the impedance characteristics to ensure that the
internal matching network is not affected.

After long term use with 40W radiated power, only a slight warming of the dipole near the feedpoint can be measured.




Certificate No: CD835V3—1014_Feb15            Page 3 of 5


Impedance Measurement Plot




                                                                   18 Feb 2015     @8:58:08
         CH1    S11     LOG       5 dB/ REF —15 dB                2:—30.749 dB     835.000 Abd MHz




                                                                                                     CH1 Markers

                                                                                                     1:—17.768 dB
         Cor                                                                                         3a0.000 MHz

                                                                                                     3:—16.938 dR
                                                                                                      900.000 MHz

                                                                                                     41—20.427 dB
                                                                                                     950.000 MHz
         Avg
         15                                                                                          S:—16.184 dB
                                                                                                      960.000 MHz

         H1d


         CH2]   S11     1 U FS          21 S0.141 o   28984 a   552.46 pH          $35.000 D00 MHz



         Del                                                                                         CH2 Markers
                                                                                                      11 43.936 a
         Cor                                                                                            —190.613 &
                                                                                                     800.000 MHz
                                                                                                      3: 53.604 o
                                                                                                        ~14.436 a
                                                                                                     9990.000 MHz

         Av                                                                                           41 43.875
         16 2                                                                                            6.5371 ¢
                                                                                                     950.000 MHz
                                                                                                      S: 49.188 o
         H1d                                                                                             15.559 ¢
                                                                                                     960.000 MHz

                      START 335.000 900 MHz                                 STOP 1 335.000 900 MHz




Certificate No: CD835V3—1014_Feb15              Page 4 of 5


DASY5 E—field Result

                                                                                               Date: 17.02.2015

Test Laboratory: SPEAG Lab2

DUT: HAC—Dipole 835 MHz; Type: CD835V3; Serial: CD835V3 — SN: 1014

Communication System: UID 0 — CW ; Frequency: 835 MHz
Medium parameters used: 0 = 0 S/m, g, = 1; p = 1000 kg/m?‘
Phantom section: RF Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI €63.19—2011)

DASY52 Configuration:

    *   Probe: ER3DV6 — SN2336; ConvF(1, 1, 1); Calibrated: 31.12.2014;
        Sensor—Surface: (Fix Surface)
    o




        Electronics: DAE4 Sn781; Calibrated: 12.09.2014
    #




        Phantom: HAC Test Arch with AMCC; Type: SD HAC PO1 BA; Serial: 1070
    e   DASY52 52.8.8{1222); SEMCAD X 14.6.10(7331)

Dipole E—Field measurement @ 835MHz/E—Scan — 835MHz d=15mm/Hearing Aid Compatibility Test (41x361x1):
Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, —6.3 mm
Reference Value = 120.9 V/m; Power Drift = 0.01 dB
Applied MIF = 0.00 dB
RF audio interference level = 40.54 dBV/m
Emission category: M3

                                            MIF scaled E—field




                                            Grid 4 M4
                                            35.61 dBV/m


                                            40.19 dBV/m|40.54 dBV/m|40.51 dBV/m




                       ~1.87


                       ~3.74


                       —5.62


                       —7.49


                       —9.36
                                0 dB = 106.4 V/m = 40.54 dBV/m



Certificate No: CD835V3—1014_Feb15                 Page 5 of 5


Calibration Laboratory of                                              &8
                                                                            y tope
                                                                                   I4
                                                                                       7/                                 Schweizerischer Kalibrierdienst




                                                        p         1t




                                                                                       &
Schmid & Partner




                                                                                            8
                                                                       mc«




                                                                 47
                                                                                                                    C     Service suisse d‘étalonnage
  Engineering AG                                                                                                          Servizio svizzero di taratura
                                                                       o




                                                                swhl




                                                                                       *, !nf
Zeughausstrasse 43, 8004 Zurich, Switzeriland                      L/NS                                             S     Swiss Calibration Service
                                                                            Ahijuls®



Accredited by the Swiss Accreditation Service (SAS)                                                                    Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

fSltent      UL CCS USA                                                                                  Certificate No: CD1880V3—1122_Feb15

CALIBRATION CERTIFICATE
                                                                                                                                                        nndeced
 Object                                 CD1880V3 — SN: 1122


 Calibration procedure(s)               QA CAL—20.v6
                                        Calibration procedure for dipoles in air




 Calibration date:                      February 17, 2015



 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (Sl).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.


 Calibration Equipment used (M&TE critical for calibration)
 Primary Standards                       ID #                      Cal Date (Certificate No.)                                  Scheduled Calibration
 Power meter EPM—442A                    GB37480704                07—Oct—14 (No. 217—02020)                                   Oct—15
 Power sensor HP 8481A                   US37292783                07—Oct—14 (No. 217—02020)                                   Oct—15
 Power sensor HP 8481A                   MY41092317                07—Oct—14 (No. 217—02021)                                   Oct—15
 Reference 10 dB Attenuator              SN: 5047.2 / 06327        03—Apr—14 (No. 217—01921)                                   Apr—15
 Probe ER3DV6                            SN: 2336                  31—Dec—14 (No. ER3—2336_Dec14)                              Dec—15
  Probe H3DV6                            SN: 6065                  31—Dec—14 (No. H3—6065_Dec14)                               Dec—15
 DAE4                                    SN: 781                       12—Sep—14 (No. DAE4—781_Sep14)                          Sep—15

 Secondary Standards                     ID #                          Check Date (in house)                                   Scheduled Check
  Power meter Agilent 4419B              SN: GB42420191                09—Oct—09 (in house check Sep—14)                       In house check: Sep—16
  Power sensor HP E4412A                 SN: US38485102                OS5—Jan—10 (in house check Sep—14)                      In house check: Sep—16
  Power sensor HP 8482A                  SN: US37295597                09—Oct—09 (in house check Sep—14)                       In house check: Sep—16
  Network Analyzer HP 8753E              US37390585                    18—Oct—01 (in house check Oct—14)                       In house check: Oct—15
  RF generator R&S SMT—O6                SN: 832283/011                27—Aug—12 (in house check Oct—13)                       In house check: Oct—16

                                         Name                                               Function



                                                                                                                               ooo
  Calibrated by:                         Leif Klysner                                       Laboratory Technician



  Approved by:                           Fin Bomholt                                        Deputy Technical Manager
                                                                                                                             —{ammtono—
                                                                                                                               Issued: February 19, 2015
  This calibration certificate shall not be reproduced except in full without written approval of the laboratory.


Certificate No: CD1880V3—1122_Feb15                          Page 1 of 7


Calibration Laboratory of                                                                       Schweizerischer Kalibrierdienst
Schmid & Partner                                                                                Service suisse d‘étalonnage
  Engineering AG                                                                                Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                    Swiss Calibration Service

Accredited by the Swiss Accreditation Service (SAS)                                        Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Muitilateral Agreement for the recognition of calibration certificates


References
{1]       ANSI—C63.19—2011
          American National Standard, Methods of Measurement of Compatibility between Wireless Communications
          Devices and Hearing Aids.
Methods Applied and Interpretation of Parameters:
      e   Coordinate System: y—axis is in the direction of the dipole arms. z—axis is from the basis of the antenna
          {mounted on the table) towards its feed point between the two dipole arms. x—axis is normal to the other axes.
          In coincidence with the standards [1], the measurement planes (probe sensor center) are selected to be at a
          distance of 15 mm above the top metal edge of the dipole arms.
      e   Measurement Conditions: Further details are available from the hardcopies at the end of the certificate. All
          figures stated in the certificate are valid at the frequency indicated. The forward power to the dipole connector
          is set with a calibrated power meter connected and monitored with an auxiliary power meter connected to a
          directional coupler. While the dipole under test is connected, the forward power is adjusted to the same level.
      *   Antenna Positioning: The dipole is mounted on a HAC Test Arch phantom using the matching dipole
          positioner with the arms horizontal and the feeding cable coming from the floor. The measurements are
          performed in a shielded room with absorbers around the setup to reduce the reflections.
          It is verified before the mounting of the dipole under the Test Arch phantom, that its arms are perfectly in a
          line. It is installed on the HAC dipole positioner with its arms parallel below the dielectric reference wire and
          able to move elastically in vertical direction without changing its relative position to the top center of the Test
          Arch phantom. The vertical distance to the probe is adjusted after dipole mounting with a DASYS Surface
          Check job. Before the measurement, the distance between phantom surface and probe tip is verified. The
          proper measurement distance is selected by choosing the matching section of the HAC Test Arch phantom
          with the proper device reference point (upper surface of the dipole) and the matching grid reference point (tip
          of the probe) considering the probe sensor offset. The vertical distance to the probe is essential for the
          accuracy.
      s   Feed Point Impedance and Return Loss: These parameters are measured using a HP 8753E Vector Network
          Analyzer. The impedance is specified at the SMA connector of the dipole. The influence of reflections was
          eliminating by applying the averaging function while moving the dipole in the air, at least 70cm away from any
          obstacles.
      *   E—field distribution: E field is measured in the x—y—plane with an isotropic ER3D—field probe with 100 mW
          forward power to the antenna feed point. In accordance with [1], the scan area is 20mm wide, its length
          exceeds the dipole arm length (180 or 9O0mm). The sensor center is 15 mm (in z) above the metal top of the
          dipole arms. Two 3D maxima are available near the end of the dipole arms. Assuming the dipole arms are
          perfectly in one line, the average of these two maxima (in subgrid 2 and subgrid 8) is determined to
          compensate for any non—parallelity to the measurement plane as well as the sensor displacement. The E—field
          value stated as calibration value represents the maximum of the interpolated 3D—E—field, in the plane above
          the dipole surface.




 The reported uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the
 coverage factor k=2, which for a normal distribution corresponds to a coverage probability of approximately 95%.




Certificate No: CD1880V3—1122_Feb15                     Page 2 of 7


Measurement Conditions
   DASYsystem configuration, as far as not given on page 1.
     DASY Version                                              DASY5                       V52.8.8
     Phantom                                                HAC Test Arch
     Distance Dipole Top — Probe Center                        15 mm
     Scan resolution                                        dx, dy = 5 mm
                                                       1730 MHz +1 MHz
     prequency                                         1880 MHz + 1 MHz
     Input power drift                                        <0.05 dB


Maximum Field values at 1730 MHz

     E—field 15 mm above dipole surface                           condition        Interpolated maximum

     Maximum measured above high end                         100 mW input power    98.9 V/m = 39.91 dBV/m

     Maximum measured above low end                          100 mW input power    93.6 V/m = 39.43 dBV/m

     Averaged maximum above arm                              100 mW input power    96.3 V/im + 12.8 % (k=2)


Maximum Field values at 1880 MHz

     E—field 15 mm above dipole surface                           condition        Interpolated maximum

     Maximum measured above high end                          100 mW input power   89.2 V/m = 39.01 dBV/m

     Maximum measured above low end                           100 mW input power   88.6 V/m = 38.95 dBV/m

     Averaged maximum above arm                               100 mW input power   88.9 V/im + 12.8 % (k=2)




Certificate No: CD1880V3—1122_Feb15           Page 3 of 7


Appendix (Additional assessments outside the scope of SCS0108)

Antenna Parameters

Nominal Frequencies

      Frequency                                                Return Loss                     Impedance
      1730 MHz                                                    32.9 dB                     51.4 Q + 1.8 jQ
      1880 MHz                                                    19.3 dB                     45.5 Q + 9.3 jQ
      1900 MHz                                                    19.8 dB                    48.3 . + 10.0 jQ
      1950 MHz                                                    26.4 dB                     52.1 Q + 4.5 jQ
      2000 MHz                                                    21.1 dB                     42.7 Q + 3.6 jQ


3.2 Antenna Design and Handling

The calibration dipole has a symmetric geometry with a built—in two stub matching network, which leads to the
enhanced bandwidth.
The dipole is built of standard semirigid coaxial cable. The internal matching line is open ended. The antenna is
therefore open for DC signals.
Do not apply force to dipole arms, as they are liable to bend. The soldered connections near the feedpoint may be
damaged. After excessive mechanical stress or overheating, check the impedance characteristics to ensure that the
internal matching network is not affected.

After long term use with 40W radiated power, only a slight warming of the dipole near the feedpoint can be measured.




Certificate No: CD1880V3—1122_Feb15            Page 4 of 7


Impedarnice Measurement Plot




                                                                   18 Feb 2015       @9:06:21
         CHB Ss11i     LoOG      5 dB—/REF —18 dB                 2i—19.319 dB      1 880.000 oo MHz




                                                                                                        CH1 Markers

                                                                                                        1:—32.947 dB
         Cor                                                                                             1.73008 6Hz

                                                                                                        3:—19,.789 dR
                                                                                                         1.90000 6Hz

                                                                                                        4:i—26.364 dB
                                                                                                         1.35000 GHz
         Av
         159                                                                                            S—21.097 dB
                                                                                                        2.00000 GHz




               $11     1 U FS          21 45.469 a   9.3359 a   7990.35 pH          1 880.000 900 MHz



         Del                                                                                            CH2 Markers
                                                                                                         1: 51.422 a
         Cor




         Aw
         16

         H1d

                     CENTER 1 880.000 080 MHz                                SPAN 1 0090.000 000 MHz




Certificate No: CD1880V3—1122_Feb15             Page 5 of 7


DASY5 E—field Result

                                                                                                    Date: 17.02.2015


Test Laboratory: SPEAG Lab2

DUT: HAC Dipole 1880 MHz; Type: CD1880V3; Serial: CD1880V3 — SN: 1122

Communication System: UID 0 — CW ; Frequency: 1880 MHz, Frequency: 1730 MHz
Medium parameters used: 0 = 0 S/m, &, = 1; p = 1000 kg/m"
Phantom section: RF Section
Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19—2011)

DASY52 Configuration:

    e   Probe: ER3DV6 — SN2336; ConvF(1, 1, 1); Calibrated: 31.12.2014;
    e   Sensor—Surface: (Fix Surface)
    *   Electronics: DAE4 Sn781; Calibrated: 12.09.2014
    *   Phantom: HAC Test Arch with AMCC; Type: SD HAC PO1 BA; Serial: 1070
    *   DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)



Dipole E—Field measurement/E—Scan — 1880MHz d=15mm/Hearing Aid Compatibility Test (41x181x1): Interpolated grid:
dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, —6.3 mm
Reference Value = 142.3 V/m; Power Drift = —0.02 dB
Applied MIF = 0.00 dB
RF audio interference level = 39.01 dBV/m
Emission category: M2

                                            MIF scaled E—field

                                            Grid 1 M2                     Grid 3 M2
                                            38.57 dBV/m|38.95 dBV/m|38.88 dBV/m

                                            Grid 4 M2                     Grid 6 M2
                                            36.44 dBV/m                   36.74 dBV/m

                                            Grid 7 M2
                                            38.72 dBV/m[39.01 dBV/m|38.95 dBV/m




Certificate No: CD1880V3—1122_Feb15                Page 6 of 7


Dipole E—Field measurement/E—Scan — 1730MHz d=15mm/Hearing Aid Compatibility Test (41x181x1): Interpolated grid:
dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, —6.3 mm
Reference Value = 156.9 V/m; Power Drift = —0.01 dB
Applied MIF = 0.00 dB
RF audio interference level = 39.91 dBV/m
Emission category: M2


                                       MIF scaled E—field

                                       Grid 1 M2                 Grid 3 M2
                                       39.05 dBV/m|39.43 dBV/m|39.37 dBV/m

                                       Grid 4 M2                 Grid 6 M2
                                       37.46 dBV/m               37.91 dBV/m

                                       Grid 7 M2 _
                                       39.53 dBV/m|39.91 dBV/m|39.88 dBV/m




                     —0.99


                     —1.99


                     —2.98


                     —3.98


                     ~4.97
                             0 dB = 89.19 V/m = 39.01 dBV/m




Certificate No: CD1880V3—1122_Feb15           Page 7 of 7



Document Created: 2015-04-10 17:37:50
Document Modified: 2015-04-10 17:37:50

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC