HAC RF Appendix_C

FCC ID: ZNFUS991

Test Report

Download: PDF
FCCID_2599711

Test Laboratory: UL Verification Services Inc. SAR Lab C                            Date: 4/8/2015

HAC-RF Emission
Communication System: UID 10021 - CAA, GSM-FDD (TDMA, GMSK); Frequency: 824.2 MHz; Duty Cycle: 1:8
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

GSM850 E-Field measurement/Voice_ch 128/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 75.35 V/m; Power Drift = 0.04 dB
Applied MIF = 3.63 dB
RF audio interference level = 39.20 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    38.19 dBV/m       39.05 dBV/m   38.76 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M4
                                    38.4 dBV/m        39.2 dBV/m    38.93 dBV/m
                                    Grid 7 M4         Grid 8 M4     Grid 9 M4
                                    38.48 dBV/m       39.12 dBV/m   38.84 dBV/m




              0 dB = 91.16 V/m = 39.20 dBV/m

                                                                                                     Plot No. 1


Test Laboratory: UL Verification Services Inc. SAR Lab C                            Date: 4/8/2015

HAC-RF Emission
Communication System: UID 10021 - CAA, GSM-FDD (TDMA, GMSK); Frequency: 836.6 MHz; Duty Cycle: 1:8
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

GSM850 E-Field measurement/Voice_ch 190/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 73.44 V/m; Power Drift = 0.00 dB
Applied MIF = 3.63 dB
RF audio interference level = 39.07 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    37.68 dBV/m       38.74 dBV/m   38.54 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M4
                                    38.12 dBV/m       39.07 dBV/m   38.85 dBV/m
                                    Grid 7 M4         Grid 8 M4     Grid 9 M4
                                    38.44 dBV/m       39.05 dBV/m   38.77 dBV/m




              0 dB = 89.82 V/m = 39.07 dBV/m

                                                                                                     Plot No. 2


Test Laboratory: UL Verification Services Inc. SAR Lab C                            Date: 4/8/2015

HAC-RF Emission
Communication System: UID 10021 - CAA, GSM-FDD (TDMA, GMSK); Frequency: 848.6 MHz; Duty Cycle: 1:8
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

GSM850 E-Field measurement/Voice_ch 251/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 71.22 V/m; Power Drift = -0.02 dB
Applied MIF = 3.63 dB
RF audio interference level = 38.76 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    37.54 dBV/m       38.49 dBV/m   38.24 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M4
                                    37.94 dBV/m       38.76 dBV/m   38.47 dBV/m
                                    Grid 7 M4         Grid 8 M4     Grid 9 M4
                                    38.23 dBV/m       38.75 dBV/m   38.45 dBV/m




              0 dB = 86.74 V/m = 38.76 dBV/m

                                                                                                     Plot No. 3


Test Laboratory: UL Verification Services Inc. SAR Lab C                            Date: 4/8/2015

HAC-RF Emission
Communication System: UID 10021 - DAB, GSM-FDD (TDMA, GMSK); Frequency: 1850.2 MHz; Duty Cycle: 1:8
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

GSM1900 E-Field measurement/Voice_ch 512/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 22.82 V/m; Power Drift = -0.08 dB
Applied MIF = 3.63 dB
RF audio interference level = 31.03 dBV/m
Emission category: M3

                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M3     Grid 3 M4
                                    29.42 dBV/m       30.1 dBV/m    29.78 dBV/m
                                    Grid 4 M4         Grid 5 M3     Grid 6 M3
                                    25.72 dBV/m       31.03 dBV/m   31.12 dBV/m
                                    Grid 7 M4         Grid 8 M3     Grid 9 M3
                                    25.36 dBV/m       31.2 dBV/m    31.26 dBV/m




              0 dB = 36.57 V/m = 31.26 dBV/m

                                                                                                      Plot No. 4


Test Laboratory: UL Verification Services Inc. SAR Lab C                            Date: 4/8/2015

HAC-RF Emission
Communication System: UID 10021 - DAB, GSM-FDD (TDMA, GMSK); Frequency: 1880 MHz; Duty Cycle: 1:8
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

GSM1900 E-Field measurement/Voice_ch 661/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 19.86 V/m; Power Drift = -0.10 dB
Applied MIF = 3.63 dB
RF audio interference level = 29.98 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    28.65 dBV/m       29.6 dBV/m    29.36 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M3
                                    25.24 dBV/m       29.98 dBV/m   30.12 dBV/m
                                    Grid 7 M4         Grid 8 M3     Grid 9 M3
                                    23.79 dBV/m       30.15 dBV/m   30.28 dBV/m




              0 dB = 32.64 V/m = 30.28 dBV/m

                                                                                                     Plot No. 5


Test Laboratory: UL Verification Services Inc. SAR Lab C                            Date: 4/8/2015

HAC-RF Emission
Communication System: UID 10021 - DAB, GSM-FDD (TDMA, GMSK); Frequency: 1909.8 MHz; Duty Cycle: 1:8
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

GSM1900 E-Field measurement/Voice_ch 810/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 18.94 V/m; Power Drift = -0.10 dB
Applied MIF = 3.63 dB
RF audio interference level = 29.89 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    28.37 dBV/m       29.22 dBV/m   29.04 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M3
                                    25.25 dBV/m       29.89 dBV/m   30.05 dBV/m
                                    Grid 7 M4         Grid 8 M3     Grid 9 M3
                                    24.14 dBV/m       30.2 dBV/m    30.28 dBV/m




              0 dB = 32.66 V/m = 30.28 dBV/m

                                                                                                      Plot No. 6


Test Laboratory: UL Verification Services Inc. SAR Lab C                                Date: 4/8/2015

HAC-RF Emission
Communication System: UID 10295 - AAB, CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 824.7 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

CDMA BC0 E-Field measurement/Voice_ch 1013/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 25.76 V/m; Power Drift = 0.01 dB
Applied MIF = 3.26 dB
RF audio interference level = 29.56 dBV/m
Emission category: M4
                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    28.47 dBV/m       29.37 dBV/m   29.17 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M4
                                    28.61 dBV/m       29.56 dBV/m   29.3 dBV/m
                                    Grid 7 M4         Grid 8 M4     Grid 9 M4
                                    33.18 dBV/m       29.41 dBV/m   29.24 dBV/m




              0 dB = 45.60 V/m = 33.18 dBV/m


                                                                                                           Plot No. 7


Test Laboratory: UL Verification Services Inc. SAR Lab C                                Date: 4/8/2015

HAC-RF Emission
Communication System: UID 10295 - AAB, CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 836.52 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

CDMA BC0 E-Field measurement/Voice_ch 384/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 26.58 V/m; Power Drift = -0.06 dB
Applied MIF = 3.26 dB
RF audio interference level = 29.76 dBV/m
Emission category: M4
                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    28.29 dBV/m       29.46 dBV/m   29.36 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M4
                                    28.79 dBV/m       29.76 dBV/m   29.59 dBV/m
                                    Grid 7 M4         Grid 8 M4     Grid 9 M4
                                    29.17 dBV/m       29.83 dBV/m   29.59 dBV/m




              0 dB = 31.03 V/m = 29.84 dBV/m


                                                                                                           Plot No. 8


Test Laboratory: UL Verification Services Inc. SAR Lab C                                Date: 4/8/2015

HAC-RF Emission
Communication System: UID 10295 - AAB, CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 848.31 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

CDMA BC0 E-Field measurement/Voice_ch 777/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 26.40 V/m; Power Drift = -0.02 dB
Applied MIF = 3.26 dB
RF audio interference level = 29.74 dBV/m
Emission category: M4
                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    29.16 dBV/m       29.42 dBV/m   29.23 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M4
                                    28.87 dBV/m       29.74 dBV/m   29.56 dBV/m
                                    Grid 7 M4         Grid 8 M4     Grid 9 M4
                                    29.21 dBV/m       29.79 dBV/m   29.5 dBV/m




              0 dB = 30.87 V/m = 29.79 dBV/m


                                                                                                           Plot No. 9


Test Laboratory: UL Verification Services Inc. SAR Lab C                               Date: 4/8/2015

HAC-RF Emission
Communication System: UID 10295 - AAB, CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 1851.25 MHz; Duty Cycle:
1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

CDMA BC1 E-Field measurement/Voice_ch 25/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 12.68 V/m; Power Drift = -0.08 dB
Applied MIF = 3.26 dB
RF audio interference level = 26.09 dBV/m
Emission category: M4
                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    24.91 dBV/m       25.69 dBV/m   25.73 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M4
                                    21.07 dBV/m       26.09 dBV/m   26.21 dBV/m
                                    Grid 7 M4         Grid 8 M4     Grid 9 M4
                                    19.96 dBV/m       26.63 dBV/m   26.97 dBV/m




              0 dB = 22.30 V/m = 26.97 dBV/m


                                                                                                         Plot No. 10


Test Laboratory: UL Verification Services Inc. SAR Lab C                                Date: 4/8/2015

HAC-RF Emission
Communication System: UID 10295 - AAB, CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 1880 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

CDMA BC1 E-Field measurement/Voice_ch 600/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 10.98 V/m; Power Drift = 1.01 dB
Applied MIF = 3.26 dB
RF audio interference level = 25.26 dBV/m
Emission category: M4
                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    23.73 dBV/m       25.2 dBV/m    25.26 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M4
                                    20.63 dBV/m       25.25 dBV/m   25.91 dBV/m
                                    Grid 7 M4         Grid 8 M4     Grid 9 M4
                                    20.22 dBV/m       25.45 dBV/m   25.82 dBV/m




              0 dB = 19.75 V/m = 25.91 dBV/m


                                                                                                          Plot No. 11


Test Laboratory: UL Verification Services Inc. SAR Lab C                               Date: 4/8/2015

HAC-RF Emission
Communication System: UID 10295 - AAB, CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 1908.75 MHz; Duty Cycle:
1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

CDMA BC1 E-Field measurement/Voice_ch 1175/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 10.39 V/m; Power Drift = 0.06 dB
Applied MIF = 3.26 dB
RF audio interference level = 24.50 dBV/m
Emission category: M4
                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    23.57 dBV/m       24.35 dBV/m   24.37 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M4
                                    21.37 dBV/m       24.5 dBV/m    25.09 dBV/m
                                    Grid 7 M4         Grid 8 M4     Grid 9 M4
                                    19.6 dBV/m        25.8 dBV/m    25.91 dBV/m




              0 dB = 19.75 V/m = 25.91 dBV/m


                                                                                                         Plot No. 12


Test Laboratory: UL Verification Services Inc. SAR Lab C                            Date: 4/8/2015

HAC-RF Emission (With Smart Cover)
Communication System: UID 10021 - CAA, GSM-FDD (TDMA, GMSK); Frequency: 824.2 MHz; Duty Cycle: 1:8
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

GSM850 E-Field measurement/Voice_ch 128/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 62.89 V/m; Power Drift = 0.05 dB
Applied MIF = 3.63 dB
RF audio interference level = 37.73 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    36.84 dBV/m       37.59 dBV/m   37.31 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M4
                                    36.91 dBV/m       37.73 dBV/m   37.47 dBV/m
                                    Grid 7 M4         Grid 8 M4     Grid 9 M4
                                    37.01 dBV/m       37.66 dBV/m   37.42 dBV/m




             0 dB = 76.99 V/m = 37.73 dBV/m


                                                                                                     Plot No. 13


Test Laboratory: UL Verification Services Inc. SAR Lab C                            Date: 4/8/2015

HAC-RF Emission (With Smart Cover)
Communication System: UID 10021 - CAA, GSM-FDD (TDMA, GMSK); Frequency: 836.6 MHz; Duty Cycle: 1:8
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

GSM850 E-Field measurement/Voice_ch 190/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 64.26 V/m; Power Drift = -0.04 dB
Applied MIF = 3.63 dB
RF audio interference level = 37.99 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    36.7 dBV/m        37.73 dBV/m   37.54 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M4
                                    36.99 dBV/m       37.99 dBV/m   37.77 dBV/m
                                    Grid 7 M4         Grid 8 M4     Grid 9 M4
                                    37.38 dBV/m       37.99 dBV/m   37.77 dBV/m




             0 dB = 79.35 V/m = 37.99 dBV/m


                                                                                                     Plot No. 14


Test Laboratory: UL Verification Services Inc. SAR Lab C                            Date: 4/8/2015

HAC-RF Emission (With Smart Cover)
Communication System: UID 10021 - CAA, GSM-FDD (TDMA, GMSK); Frequency: 848.6 MHz; Duty Cycle: 1:8
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

GSM850 E-Field measurement/Voice_ch 251/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 65.52 V/m; Power Drift = -0.01 dB
Applied MIF = 3.63 dB
RF audio interference level = 38.06 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    36.97 dBV/m       37.87 dBV/m   37.59 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M4
                                    37.25 dBV/m       38.06 dBV/m   37.85 dBV/m
                                    Grid 7 M4         Grid 8 M4     Grid 9 M4
                                    37.6 dBV/m        38.07 dBV/m   37.79 dBV/m




             0 dB = 80.10 V/m = 38.07 dBV/m


                                                                                                     Plot No. 15


Test Laboratory: UL Verification Services Inc. SAR Lab C                            Date: 4/8/2015

HAC-RF Emission (With Smart Cover)
Communication System: UID 10021 - DAB, GSM-FDD (TDMA, GMSK); Frequency: 1850.2 MHz; Duty Cycle: 1:8
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

GSM1900 E-Field measurement/Voice_ch 512/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 21.93 V/m; Power Drift = 0.03 dB
Applied MIF = 3.63 dB
RF audio interference level = 30.46 dBV/m
Emission category: M3

                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    28.65 dBV/m       29.12 dBV/m   29.05 dBV/m
                                    Grid 4 M4         Grid 5 M3     Grid 6 M3
                                    25.1 dBV/m        30.46 dBV/m   30.51 dBV/m
                                    Grid 7 M4         Grid 8 M3     Grid 9 M3
                                    25.77 dBV/m       30.69 dBV/m   30.71 dBV/m




             0 dB = 34.33 V/m = 30.71 dBV/m


                                                                                                      Plot No. 16


Test Laboratory: UL Verification Services Inc. SAR Lab C                            Date: 4/8/2015

HAC-RF Emission (With Smart Cover)
Communication System: UID 10021 - DAB, GSM-FDD (TDMA, GMSK); Frequency: 1880 MHz; Duty Cycle: 1:8
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

GSM1900 E-Field measurement/Voice_ch 661/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 20.17 V/m; Power Drift = -0.01 dB
Applied MIF = 3.63 dB
RF audio interference level = 29.74 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    28.67 dBV/m       29.42 dBV/m   29.12 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M4
                                    25.15 dBV/m       29.74 dBV/m   29.85 dBV/m
                                    Grid 7 M4         Grid 8 M4     Grid 9 M4
                                    23.9 dBV/m        29.85 dBV/m   29.93 dBV/m




             0 dB = 31.37 V/m = 29.93 dBV/m


                                                                                                     Plot No. 17


Test Laboratory: UL Verification Services Inc. SAR Lab C                            Date: 4/9/2015

HAC-RF Emission (With Smart Cover)
Communication System: UID 10021 - DAB, GSM-FDD (TDMA, GMSK); Frequency: 1909.8 MHz; Duty Cycle: 1:8
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

GSM1900 E-Field measurement/Voice_ch 810/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 18.40 V/m; Power Drift = 0.03 dB
Applied MIF = 3.63 dB
RF audio interference level = 29.24 dBV/m
Emission category: M4

                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    28.18 dBV/m       29.06 dBV/m   28.82 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M4
                                    24.52 dBV/m       29.24 dBV/m   29.38 dBV/m
                                    Grid 7 M4         Grid 8 M4     Grid 9 M4
                                    23.35 dBV/m       29.41 dBV/m   29.52 dBV/m




             0 dB = 29.93 V/m = 29.52 dBV/m


                                                                                                      Plot No. 18


Test Laboratory: UL Verification Services Inc. SAR Lab C                                Date: 4/8/2015

HAC-RF Emission (With Smart Cover)
Communication System: UID 10295 - AAB, CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 824.7 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

CDMA BC0 E-Field measurement/Voice_ch 1013/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 22.53 V/m; Power Drift = 0.00 dB
Applied MIF = 3.26 dB
RF audio interference level = 35.34 dBV/m
Emission category: M4
                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    34.27 dBV/m       34.99 dBV/m   27.91 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M4
                                    34.67 dBV/m       35.34 dBV/m   28.1 dBV/m
                                    Grid 7 M4         Grid 8 M4     Grid 9 M4
                                    35.62 dBV/m       37.03 dBV/m   28.02 dBV/m




              0 dB = 71.05 V/m = 37.03 dBV/m


                                                                                                          Plot No. 19


Test Laboratory: UL Verification Services Inc. SAR Lab C                                Date: 4/8/2015

HAC-RF Emission (With Smart Cover)
Communication System: UID 10295 - AAB, CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 836.52 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

CDMA BC0 E-Field measurement/Voice_ch 384/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 23.93 V/m; Power Drift = -0.05 dB
Applied MIF = 3.26 dB
RF audio interference level = 34.14 dBV/m
Emission category: M4
                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    34.67 dBV/m       34.14 dBV/m   31.84 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M4
                                    36.03 dBV/m       33.69 dBV/m   34.14 dBV/m
                                    Grid 7 M4         Grid 8 M4     Grid 9 M4
                                    35.02 dBV/m       33.37 dBV/m   31.2 dBV/m




             0 dB = 63.33 V/m = 36.03 dBV/m



                                                                                                          Plot No. 20


Test Laboratory: UL Verification Services Inc. SAR Lab C                                Date: 4/8/2015

HAC-RF Emission (With Smart Cover)
Communication System: UID 10295 - AAB, CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 848.31 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

CDMA BC0 E-Field measurement/Voice_ch 777/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 24.59 V/m; Power Drift = 0.10 dB
Applied MIF = 3.26 dB
RF audio interference level = 29.19 dBV/m
Emission category: M4
                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    28.09 dBV/m       29 dBV/m      28.68 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M4
                                    28.35 dBV/m       29.19 dBV/m   28.96 dBV/m
                                    Grid 7 M4         Grid 8 M4     Grid 9 M4
                                    28.81 dBV/m       29.24 dBV/m   28.91 dBV/m




             0 dB = 28.96 V/m = 29.24 dBV/m



                                                                                                          Plot No. 21


Test Laboratory: UL Verification Services Inc. SAR Lab C                               Date: 4/8/2015

HAC-RF Emission (With Smart Cover)
Communication System: UID 10295 - AAB, CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 1851.25 MHz; Duty Cycle:
1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

CDMA BC1 E-Field measurement/Voice_ch 25/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 13.12 V/m; Power Drift = 0.06 dB
Applied MIF = 3.26 dB
RF audio interference level = 25.53 dBV/m
Emission category: M4
                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    23.68 dBV/m       24.32 dBV/m   24.26 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M4
                                    20.23 dBV/m       25.53 dBV/m   25.56 dBV/m
                                    Grid 7 M4         Grid 8 M4     Grid 9 M4
                                    20.82 dBV/m       25.73 dBV/m   25.76 dBV/m




             0 dB = 19.41 V/m = 25.76 dBV/m


                                                                                                         Plot No. 22


Test Laboratory: UL Verification Services Inc. SAR Lab C                                Date: 4/8/2015

HAC-RF Emission (With Smart Cover)
Communication System: UID 10295 - AAB, CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 1880 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

CDMA BC1 E-Field measurement/Voice_ch 600/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 12.07 V/m; Power Drift = -0.00 dB
Applied MIF = 3.26 dB
RF audio interference level = 24.83 dBV/m
Emission category: M4
                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    23.43 dBV/m       24.38 dBV/m   24.1 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M4
                                    19.89 dBV/m       24.83 dBV/m   24.9 dBV/m
                                    Grid 7 M4         Grid 8 M4     Grid 9 M4
                                    18.9 dBV/m        24.89 dBV/m   24.95 dBV/m




             0 dB = 17.68 V/m = 24.95 dBV/m



                                                                                                          Plot No. 23


Test Laboratory: UL Verification Services Inc. SAR Lab C                               Date: 4/8/2015

HAC-RF Emission (With Smart Cover)
Communication System: UID 10295 - AAB, CDMA2000, RC1, SO3, 1/8th Rate 25 fr.; Frequency: 1908.75 MHz; Duty Cycle:
1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

CDMA BC1 E-Field measurement/Voice_ch 1175/Hearing Aid Compatibility Test
(101x101x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 10.74 V/m; Power Drift = 0.00 dB
Applied MIF = 3.26 dB
RF audio interference level = 24.09 dBV/m
Emission category: M4
                                    MIF scaled E-field
                                    Grid 1 M4         Grid 2 M4     Grid 3 M4
                                    22.71 dBV/m       23.73 dBV/m   23.55 dBV/m
                                    Grid 4 M4         Grid 5 M4     Grid 6 M4
                                    19.39 dBV/m       24.09 dBV/m   24.21 dBV/m
                                    Grid 7 M4         Grid 8 M4     Grid 9 M4
                                    18.43 dBV/m       24.26 dBV/m   24.36 dBV/m




             0 dB = 16.53 V/m = 24.37 dBV/m


                                                                                                         Plot No. 24



Document Created: 2015-04-20 20:34:59
Document Modified: 2015-04-20 20:34:59

© 2025 FCC.report