HAC RF Appendix_B

FCC ID: ZNFUS991

Test Report

Download: PDF
FCCID_2599710

Test Laboratory: UL Verification Services Inc. SAR Lab C                           Date: 4/6/2015

HAC-RF Emission
Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

Dipole E-Field measurement/835 MHz/Hearing Aid Compatibility Test at 15mm distance
(41x361x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 104.3 V/m; Power Drift = -0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 107.0 V/m
Near-field category: M4 (AWF 0 dB)
                                         PMF scaled E-field
                                          Grid 1 M4 Grid 2 M4 Grid 3 M4
                                          104.6 V/m        105.9 V/m   104.1 V/m
                                          Grid 4 M4        Grid 5 M4   Grid 6 M4
                                          62.25 V/m        62.64 V/m   61.10 V/m
                                          Grid 7 M4        Grid 8 M4   Grid 9 M4
                                          105.3 V/m        107.0 V/m   104.3 V/m
Cursor:
Total = 107.0 V/m
E Category: M4
Location: 0.5, 78, 9.7 mm




             0 dB = 107.0 V/m = 40.59 dBV/m
Test Laboratory: UL Verification Services Inc. SAR Lab C                           Date: 4/6/2015


HAC-RF Emission
Communication System: UID 0, CW; Frequency: 1880 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: ER3DV6 - SN2509; ConvF(1, 1, 1); Calibrated: 5/16/2014;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE3 Sn427; Calibrated: 1/14/2015
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (7);SEMCAD X Version 14.6.10 (7164)

Dipole E-Field measurement/1880 MHz/Hearing Aid Compatibility Test at 15mm
distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 142.2 V/m; Power Drift = -0.00 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 86.13 V/m
Near-field category: M3 (AWF 0 dB)
                                        PMF scaled E-field
                                         Grid 1 M3 Grid 2 M3 Grid 3 M3
                                         84.83 V/m    86.13 V/m   84.77 V/m
                                         Grid 4 M3    Grid 5 M3   Grid 6 M3
                                         69.65 V/m    70.14 V/m   68.78 V/m
                                         Grid 7 M3    Grid 8 M3   Grid 9 M3
                                         81.85 V/m    83.48 V/m   82.73 V/m
Cursor:
Total = 86.13 V/m
E Category: M3
Location: 0, -30.5, 9.7 mm




              0 dB = 86.13 V/m = 38.70 dBV/m



Document Created: 2015-04-20 17:42:22
Document Modified: 2015-04-20 17:42:22