DFS Test Report

FCC ID: ZNFTP260

Test Report

Download: PDF
FCCID_3237522

                                PCTEST ENGINEERING LABORATORY, INC.
                                              7185 Oakland Mills Road, Columbia, MD 21045 USA
                                                    Tel. 410.290.6652 / Fax 410.290.6654
                                                           http://www.pctestlab.com

                                                 MEASUREMENT REPORT
                                                      FCC PART 15.407 DFS

 Company Name:                                                                 Date of Testing:
 LG Electronics MobileComm U.S.A                                               11/08-11/16/2016
 1000 Sylvan Avenue                                                            Test Site/Location:
 Englewood Cliffs, NJ 07632                                                    PCTEST Lab. Columbia, MD, USA
 United States                                                                 Test Report Serial No.:
                                                                               0Y1611071725.ZNF


 FCC ID:                                        ZNFTP260

 COMPANY:                                       LG Electronics MobileComm U.S.A

 Model(s):                                      LG-TP260, LGTP260, TP260, LG-MP260, LGMP260, MP260, LG-
                                                TP260BK, LGTP260BK, TP260BK
 EUT Type:                                      Portable Handset
 Type of Device:                                Client Only Device, No Radar Detection Capability
 Frequency Range:                               5260 – 5320 MHz (UNII-2A Band)
                                                5500 – 5700 MHz (UNII-2C Band)
 Output Power:                                  84.528 mW (19.27 dBm) Conducted (802.11a UNII Band 2A)
                                                69.502 mW (18.42 dBm) Conducted (802.11a UNII Band 2C)
 FCC Classification:                            Unlicensed National Information Infrastructure (UNII)
 FCC Rule Part(s):                              Part 15.407(UNII)
 Test Procedure(s):                             KDB 905462 D02 v02

 This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement
 report and was tested in accordance with the measurement procedures specified in KDB 905462 D02 v02 Compliance Measurement
 Procedures for Unlicensed-National Information Infrastructure Devices Operating in the 5.25 – 5.35 GHz and 5.47 – 5.725 GHz Bands
 Incorporating Dynamic Frequency Selection. Test results reported herein relate only to the item(s) tested.

 I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are
 correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for
 the qualifications of all persons taking them.




                                                             FCC Pt. 15.407 DFS TEST REPORT                             Reviewed by:
FCC ID: ZNFTP260
                                                                     (CERTIFICATION)                                    Quality Manager
Test Report S/N:             Test Dates:            EUT Type:
                                                                                                                        Page 1 of 15
0Y1611071725.ZNF             11/08-11/16/2016       Portable Handset
 © 2016 PCTEST Engineering Laboratory, Inc.                                                                                            V 5.0
                                                                                                                                 11/04/2016


                                           T A B L E                        O F             C O N T E N T S


 FCC PART 15.407 MEASUREMENT REPORT .................................................................................................. 3
 1.0         INTRODUCTION......................................................................................................................................4
             1.1     Scope ............................................................................................................................................................. 4
             1.2     Evaluation Procedure ..................................................................................................................................... 4
             1.3     Summary of Test Results ............................................................................................................................... 4
 2.0         PRODUCT INFORMATION .....................................................................................................................5
             2.1     Equipment Description ................................................................................................................................... 5
             2.2     EUT Capabilities............................................................................................................................................. 5
             2.3     Modifications .................................................................................................................................................. 5
 3.0         DESCRIPTION OF DYNAMIC FREQUENCY SELECTION TEST .........................................................6
             3.1     Applicability .................................................................................................................................................... 6
             3.2     Requirements ................................................................................................................................................. 6
             3.3     DFS Detection Threshold Values ................................................................................................................... 8
             3.4     Parameters of DFS Test Signals .................................................................................................................... 8
             3.5     Procedure ....................................................................................................................................................... 9
 4.0         TEST EQUIPMENT................................................................................................................................10
             4.1     Additional Equipment ................................................................................................................................... 10
 5.0         TEST RESULTS ....................................................................................................................................11
 6.0         CONCLUSION .......................................................................................................................................15




                                                                        FCC Pt. 15.407 DFS TEST REPORT                                                            Reviewed by:
FCC ID: ZNFTP260
                                                                                (CERTIFICATION)                                                                   Quality Manager
Test Report S/N:             Test Dates:                    EUT Type:
                                                                                                                                                                  Page 2 of 15
0Y1611071725.ZNF             11/08-11/16/2016               Portable Handset
 © 2016 PCTEST Engineering Laboratory, Inc.                                                                                                                                         V 5.0
                                                                                                                                                                              11/04/2016


                                              DFS MEASUREMENT REPORT
                                                                FCC Part 15.407


 § 2.1033 General Information
         APPLICANT:                               LG Electronics MobileComm U.S.A
         APPLICANT ADDRESS:                       1000 Sylvan Avenue
                                                  Englewood Cliffs, NJ 07632, United States
         TEST SITE:                               PCTEST ENGINEERING LABORATORY, INC.
         TEST SITE ADDRESS:                       7185 Oakland Mills Road, Columbia, MD 21046 USA
         FCC RULE PART(S):                        Part 15.407(h)
         BASE MODEL:                              LG-TP260
         FCC ID:                                  ZNFTP260
         Test Device Serial No.:                  00308, 00316                      Production   Pre-Production    Engineering
         DEVICE CLASSIFICATION:                   Client Only, No Radar Detection
         DATE(S) OF TEST:                         11/08-11/16/2016
         TEST REPORT S/N:                         0Y1611071725.ZNF


Test Facility / Accreditations
Measurements were performed at PCTEST Engineering Lab located in Columbia, MD 21045, U.S.A.
                                 PCTEST facility is an FCC registered (PCTEST Reg. No. 159966) test facility with the
                                  site description report on file and has met all the requirements specified in Section 2.948
                                  of the FCC Rules and Industry Canada (2451B-1).
                                 PCTEST Lab is accredited to ISO 17025 by U.S. National Institute of Standards and
                                  Technology (NIST) under the National Voluntary Laboratory Accreditation Program
                                  (NVLAP Lab code: 100431-0) in EMC, FCC and Telecommunications.
                                 PCTEST Lab is accredited to ISO 17025-2005 by the American Association for
                                  Laboratory Accreditation (A2LA) in Specific Absorption Rate (SAR) testing, Hearing Aid
                                  Compatibility (HAC) testing, CTIA Test Plans, and wireless testing for FCC and Industry
                                  Canada Rules.
                                 PCTEST Lab is a recognized U.S. Conformity Assessment Body (CAB) in EMC and
                                  R&TTE (n.b. 0982) under the U.S.-EU Mutual Recognition Agreement (MRA).
                                 PCTEST TCB is a Telecommunication Certification Body (TCB) accredited to ISO/IEC
                                  Guide 65 by the American National Standards Institute (ANSI) in all scopes of FCC Rules
                                  and Industry Canada Standards (RSS).
                                 PCTEST facility is an IC registered (2451B-1) test laboratory with the site description on
                                  file at Industry Canada.
                                 PCTEST is a CTIA Authorized Test Laboratory (CATL) for AMPS, CDMA, and EvDO
                                  wireless devices and for Over-the-Air (OTA) Antenna Performance testing for AMPS,
                                  CDMA, GSM, GPRS, EGPRS, UMTS (W-CDMA), CDMA 1xEVDO, and CDMA 1xRTT.




                                                             FCC Pt. 15.407 DFS TEST REPORT                       Reviewed by:
FCC ID: ZNFTP260
                                                                     (CERTIFICATION)                              Quality Manager
Test Report S/N:               Test Dates:          EUT Type:
                                                                                                                  Page 3 of 15
0Y1611071725.ZNF               11/08-11/16/2016     Portable Handset
 © 2016 PCTEST Engineering Laboratory, Inc.                                                                                      V 5.0
                                                                                                                           11/04/2016


 1.0 I N T R O D U C T I O N

 1.1 Scope
 This report has been prepared to demonstrate compliance with the requirements for Dynamic Frequency
 Selection (DFS) as stated in KDB 905462 D02 v02. Testing was performed on the LG Portable Handset
 FCC ID: ZNFTP260. As of July 20, 2007 all devices operating in the 5250 – 5350 MHz and/or the 5470 –
 5725 MHz bands must comply with the DFS requirements. As the EUT does not have radar detection
 capability it was evaluated as a Client Only Device. All test results reported herein are applicable to the
 sample selected for testing. The unit used for testing was supplied by LG Electronics MobileComm U.S.A.

 1.2 Evaluation Procedure
 Conducted test methodology was used for the DFS evaluation procedure of the EUT. No deviations to the test
 procedure and test methods occurred during the evaluation of the EUT.

 1.3 Summary of Test Results
 The EUT was found to be compliant with the requirements for DFS as required for a Client Device per Part
 15.407(h) and KDB 905462 D02 v02. The following table lists the measured parameters. The actual data and
 plots can be found in Section 5 and 6 of this report.


                                    Parameter                               Measured                  Limit              Result
   5260 – 5320 MHz




                     Channel Move Time                              2.12s                    10 seconds                   Pass
    UNII – 2A Band




                                                                                             200ms + aggregate of
                                                                    < 200ms
                     Channel Closing Transmission Time                                       60ms over remaining          Pass
                                                                    + 18.7ms (aggregate)
                                                                                             10 second period
                                                                    Monitored for 10
                                                                                             No client transmission
                     Client beacon test                             minutes with no client                                Pass
                                                                                             occurred
                                                                    transmission
UNII – 2C Band




                     Channel Move Time                              2.61s                    10 seconds                   Pass
 5470 – 5725




                                                                                             200ms + aggregate of
                                                                    < 200ms
     MHz




                     Channel Closing Transmission Time                                       60ms over remaining          Pass
                                                                    + 1.04ms (aggregate)
                                                                                             10 second period
                                                              Monitored for 10
                                                                                     No client transmission
                     Client beacon test                       minutes with no client                                      Pass
                                                                                     occurred
                                                              transmission
                                                Table 1-1. DFS Test Results Summary




                                                          FCC Pt. 15.407 DFS TEST REPORT                         Reviewed by:
FCC ID: ZNFTP260
                                                                  (CERTIFICATION)                                Quality Manager
Test Report S/N:             Test Dates:         EUT Type:
                                                                                                                 Page 4 of 15
0Y1611071725.ZNF             11/08-11/16/2016    Portable Handset
 © 2016 PCTEST Engineering Laboratory, Inc.                                                                                     V 5.0
                                                                                                                          11/04/2016


 2.0 P R O D U C T I N F O R M A T I O N

 2.1 Equipment Description
 The Equipment Under Test (EUT) is the LG Portable Handset FCC ID: ZNFTP260.

             Mode of Operation:

                              Master Device
                              Client Device (No radar detection)
                              Client Device with Radar Detection



   Parameters of EUT:

                                       5260 – 5320 MHz
   Frequency
                                       5500 – 5700 MHz

                                       84.528 mW (19.27 dBm) Conducted (802.11a UNII Band 2A)
   Output Power:
                                       69.502 mW (18.42 dBm) Conducted (802.11a UNII Band 2C)

   Modulation:                         OFDM

   Channel Bandwidth:                  20, 40 MHz




 2.2 EUT Capabilities
 This device contains the following capabilities:

 850/1900 GSM/GPRS/EDGE, 850/1700/1900 WCDMA/HSPA, Multi-band LTE, 802.11b/g/n WLAN, 802.11a/n
 UNII, Bluetooth (1x, EDR, LE)

 2.3 Modifications
 No modifications to the EUT were required in order to comply with the DFS specifications.




                                                         FCC Pt. 15.407 DFS TEST REPORT         Reviewed by:
FCC ID: ZNFTP260
                                                                 (CERTIFICATION)                Quality Manager
Test Report S/N:             Test Dates:         EUT Type:
                                                                                                Page 5 of 15
0Y1611071725.ZNF             11/08-11/16/2016   Portable Handset
 © 2016 PCTEST Engineering Laboratory, Inc.                                                                    V 5.0
                                                                                                         11/04/2016


 3.0 D E S C R I P T I O N O F D Y N A M I C F R E Q U E N C Y S E L E C T I O N T E S T

 3.1 Applicability
 The following table from KDB 905462 D02 v02 lists the applicable requirements for the DFS testing. The
 device evaluated in this report is considered a client device without radar detection capability.

              Requirement                                            Operational Mode

                                                                                 Client Without    Client With Radar
                                                                      Master
                                                                                Radar Detection        Detection
              Non-Occupancy Period                                     Yes        Not required              Yes

              DFS Detection Threshold                                  Yes        Not required              Yes
              Channel Availability Check Time                          Yes        Not required          Not required
              Uniform Spreading                                        Yes        Not required          Not required

              U-NII Detection Bandwidth                                Yes        Not required              Yes
                                                      Table 3-1. DFS Applicability


      Requirement
                                                                 Operational Mode

                                                                                            Client             Client
                                                                       Master           Without Radar        With Radar
                                                                                          Detection          Detection

      DFS Detection Threshold                                            Yes            Not required              Yes

      Channel Closing Transmission Time                                  Yes                Yes                   Yes

      Channel Move Time                                                  Yes                Yes                   Yes

      U-NII Detection Bandwidth                                          Yes            Not required              Yes

      Client Beacon Test                                                 N/A                Yes                   Yes
                                         Table 3-2. DFS Applicability During Normal Operation

 3.2 Requirements
 Per KDB 905462 D02 v02 the following are the requirements for Client Devices:

 a) A Client Device will not transmit before having received appropriate control signals from a Master Device.
 b) A Client Device will stop all its transmissions whenever instructed by a Master Device to which it is
    associated and will meet the Channel Move Time and Channel Closing Transmission Time requirements.




                                                           FCC Pt. 15.407 DFS TEST REPORT                         Reviewed by:
FCC ID: ZNFTP260
                                                                   (CERTIFICATION)                                Quality Manager
Test Report S/N:             Test Dates:          EUT Type:
                                                                                                                  Page 6 of 15
0Y1611071725.ZNF             11/08-11/16/2016     Portable Handset
 © 2016 PCTEST Engineering Laboratory, Inc.                                                                                      V 5.0
                                                                                                                           11/04/2016


     The Client Device will not resume any transmissions until it has again received control signals from a
     Master Device.
 c) If a Client Device is performing In-Service Monitoring and detects a Radar Waveform above the DFS
    Detection Threshold, it will inform the Master Device. This is equivalent to the Master Device detecting the
    Radar Waveform and d) through f) of section 5.1.1 apply.
 d) Irrespective of Client Device or Master Device detection the Channel Move Time and Channel Closing
    Transmission Time requirements remain the same.


 Channel Move Time and Channel Closing Transmission Time requirements are listed in the following table.

Parameter                                                                            Value

Non-occupancy period                                                                 Minimum 30 minutes

Channel Availability Check Time                                                      60 seconds

                                                                                     10 seconds
Channel Move Time
                                                                                     See Note 1.
Channel Closing Transmission Time                                                    200 milliseconds + an
                                                                                     aggregate of 60 milliseconds over
                                                                                     remaining 10 second period. See Notes
                                                                                     1 and 2.
                                                                                     Minimum 80% of the U-
U-NII Detection Bandwidth                                                            NII 99% transmission
                                                                                     power bandwidth. See Note 3.
Note 1: The instant that the Channel Move Time and the Channel Closing Transmission Time begins is
as follows:
• For the Short Pulse Radar Test Signals this instant is the end of the Burst.
• For the Frequency Hopping radar Test Signal, this instant is the end of the last radar
Burst generated.
• For the Long Pulse Radar Test Signal this instant is the end of the 12 second period
defining the Radar Waveform.
Note 2: The Channel Closing Transmission Time is comprised of 200 milliseconds starting at
the beginning of the Channel Move Time plus any additional intermittent control signals required
to facilitate a Channel move (an aggregate of 60 milliseconds) during the remainder of the 10
second period. The aggregate duration of control signals will not count quiet periods in between
transmissions.
Note 3: During the U-NII Detection Bandwidth detection test, radar type 1 is used and for each
frequency step the minimum percentage of detection is 90 percent. Measurements are performed
with no data traffic.
                                 Table 3-3: DFS Response Requirements




                                                         FCC Pt. 15.407 DFS TEST REPORT                         Reviewed by:
FCC ID: ZNFTP260
                                                                 (CERTIFICATION)                                Quality Manager
Test Report S/N:             Test Dates:        EUT Type:
                                                                                                                Page 7 of 15
0Y1611071725.ZNF             11/08-11/16/2016   Portable Handset
 © 2016 PCTEST Engineering Laboratory, Inc.                                                                                    V 5.0
                                                                                                                         11/04/2016


 3.3 DFS Detection Threshold Values
 The DFS detection thresholds are defined for Master devices and Client Devices with In-service monitoring.
 These detection thresholds are listed in the following table.

                                                                                                   Value
    Maximum Transmit Power
                                                                                                   (See Notes 1 and 2)

    ≥ 200 milliwatt                                                                                -64 dBm

    < 200 milliwatt                                                                                -62 dBm
    Note 1: This is the level at the input of the receiver assuming a 0 dBi receive antenna.

    Note 2: Throughout these test procedures an additional 1 dB has been added to the amplitude of
    the test transmission waveforms to account for variations in measurement equipment. This will
    ensure that the test signal is at or above the detection threshold level to trigger a DFS response.
        Table 3-4: Detection Thresholds for Master Devices and Client Devices with Radar Detection


 3.4 Parameters of DFS Test Signals
 As the EUT is a Client Device with no Radar Detection only one type radar pulse is required for the testing.
 Radar Pulse type 1 was used in the evaluation of the Client device for the purpose of measuring the Channel
 Move Time and the Channel Closing Transmission Time. Table 3-5 lists the parameters for the Short Pulse
 Radar Waveforms. A plot of the Radar Pulse Type 1 used for testing is included in Section 5.0 of this report.


                                                                                                         Minimum
                                                                                     Number                            Minimum
                                     Pulse Width                      PRI                              Percentage of
           Radar Type                                                                  of                              Number of
                                       (μsec)                       (μsec)                              Successful
                                                                                     Pulses                              Trials
                                                                                                         Detection

                   1                           1                     1428                18                60%            30

                   2                          1-5                   150-230           23-29                60%            30

                   3                          6-10                  200-500           16-18                60%            30

                   4                       11-20                    200-500           12-16                60%            30

          Aggregate (Radar Types 1-4)                                                                      80%            120
                                       Table 3-5: Parameters for Short Pulse Radar Waveforms

                                                                                                            Minimum
                          Pulse                Chirp                          Number                                      Minimum
        Radar                                                    PRI                      Number          Percentage of
                          Width                Width                         of Pulses                                    Number of
        Type                                                   (μsec)                     of Bursts        Successful
                          (μsec)               (MHz)                         per Burst                                      Trials
                                                                                                            Detection
            5            50 - 100              5 - 20          5 – 20          1-3            8 - 20           60%              30
                                       Table 3-6. Parameters for Long Pulse Radar Waveforms



                                                                 FCC Pt. 15.407 DFS TEST REPORT                           Reviewed by:
FCC ID: ZNFTP260
                                                                         (CERTIFICATION)                                  Quality Manager
Test Report S/N:             Test Dates:                EUT Type:
                                                                                                                          Page 8 of 15
0Y1611071725.ZNF             11/08-11/16/2016           Portable Handset
 © 2016 PCTEST Engineering Laboratory, Inc.                                                                                                V 5.0
                                                                                                                                     11/04/2016


                                                                                      Hopping    Minimum       Minimum
                            Pulse                           Pulses       Hopping
           Radar                                PRI                                   Sequence Percentage of   Number
                            Width                            per          Rate
           Type                               (μsec)                                   Length   Successful        of
                            (μsec)                           Hop          (kHz)
                                                                                       (msec)    Detection      Trials
              6                 1               333               9       0.333          300        70%           30
                                Table 3-7. Parameters for Frequency Hopping Radar Waveforms

 3.5 Procedure
 KDB 905462 D02 v02 describes a radiated test setup and a conducted test setup. The conducted test setup
 was used for this testing. Figure 3-1 shows the typical test setup. In Band 2A, one channel selected between
 5260 and 5350 MHz is chosen for the testing. In Band 2C, one channel selected between 5500 and 5700
 MHz was chosen for testing.




                                                Figure 3-1. Conducted Test Setup for DFS

       1. The “Aeroflex PXI DFS Radar Simulator and Analyzer Test Suite” is setup to provide a simulated
          radar pulse at the frequency that the Master and Client are operating. A Type 0 radar pulse was used.
       2. The Client Device (EUT) is set up per the diagram in Figure 3-1 and communications between the
          Master device and the Client is established.
       3. An MPEG or data file that is typical for the device is streamed from the Master to the Client to properly
          load the network.
       4. The “Aeroflex PXI DFS Radar Simulator and Analyzer Test Suite” is set to record and display 12
          seconds of time, starting from where the simulated radar is generated. This time domain plot captures
          any transmissions occurring up to and after 10sec. Aggregate time is computed to ensure
          compliance. (Note: the channel may be different since the Master and Client have changed channels
          due to the detection of the initial radar pulse.)
       5. After the initial radar burst the channel is monitored for 10 minutes to ensure no transmissions or
          beacons occur. A second monitoring setup is used to verify that the Master and Client have both
          moved to different channels.




                                                               FCC Pt. 15.407 DFS TEST REPORT                   Reviewed by:
FCC ID: ZNFTP260
                                                                       (CERTIFICATION)                          Quality Manager
Test Report S/N:             Test Dates:              EUT Type:
                                                                                                                Page 9 of 15
0Y1611071725.ZNF             11/08-11/16/2016         Portable Handset
 © 2016 PCTEST Engineering Laboratory, Inc.                                                                                    V 5.0
                                                                                                                         11/04/2016


 4.0 T E S T E Q U I P M E N T

 Test Equipment Calibration is traceable to the National Institute of Standards and Technology (NIST).
 Measurements antennas used during testing were calibrated in accordance to the requirements of ANSI
 C63.5-2006.

    Manufacturer                Model                        Description               Cal Date   Cal Interval    Cal Due   Serial Number

       Ae ofle                PXI               PXI DFS Rada Si ulato & A al ze         / /        Bie    ial     / /
        Agile t                E      A         PSA     Hz‐ GHz Spe t u     A al ze     / /         A    ual      / /         US
        Agile t                N      A                   MXE EMI Re eive               / /         A    ual      / /         MY
       Seeko k                 NC‐                    To ue W e h / ", " l s            / /        Bie    ial     / /              N/A
                                        Table 4-1. Annual Test Equipment Calibration Schedule


 4.1 Additional Equipment

 The following equipment was used in support of the DFS testing.


                   Device            Manufacturer           Model/Description           Description                S/N:

                                                           AIR-CAP2702E-A-K9           Access Point            FTX1834S05B
                   Master            Cisco Systems
                                                           AIR-CT2504-K9 V03             Controller            PSZ18381P6K

                                                        Table 4-2. Support Equipment




                                                             FCC Pt. 15.407 DFS TEST REPORT                                 Reviewed by:
FCC ID: ZNFTP260
                                                                     (CERTIFICATION)                                        Quality Manager
Test Report S/N:             Test Dates:              EUT Type:
                                                                                                                            Page 10 of 15
0Y1611071725.ZNF             11/08-11/16/2016      Portable Handset
 © 2016 PCTEST Engineering Laboratory, Inc.                                                                                                V 5.0
                                                                                                                                     11/04/2016


 5.0 T E S T R E S U L T S

 Channel Loading Notes:
 Per KDB 905462 D02 v01, timing plots are required with calculations demonstrating a minimum channel
 loading of approximately 17% or greater. For example, you can zero span the spectrum analyzer and
 approximate the transmission time.




                                                  Figure 5-1. Band 2A Pulse Width




                                                      Figure 5-2. Band 2A Period

                                     Channel Loading = Pulse Width / Period = 50µs / 180µs = 28%

                                                          FCC Pt. 15.407 DFS TEST REPORT           Reviewed by:
FCC ID: ZNFTP260
                                                                  (CERTIFICATION)                  Quality Manager
Test Report S/N:             Test Dates:         EUT Type:
                                                                                                   Page 11 of 15
0Y1611071725.ZNF             11/08-11/16/2016    Portable Handset
 © 2016 PCTEST Engineering Laboratory, Inc.                                                                       V 5.0
                                                                                                            11/04/2016


                                                  Figure 5-3. Band 2C Pulse Width




                                                      Figure 5-4. Band 2C Period

                                     Channel Loading = Pulse Width / Period = 40µs / 180µs = 22%
                                                          FCC Pt. 15.407 DFS TEST REPORT           Reviewed by:
FCC ID: ZNFTP260
                                                                  (CERTIFICATION)                  Quality Manager
Test Report S/N:             Test Dates:         EUT Type:
                                                                                                   Page 12 of 15
0Y1611071725.ZNF             11/08-11/16/2016    Portable Handset
 © 2016 PCTEST Engineering Laboratory, Inc.                                                                       V 5.0
                                                                                                            11/04/2016


 Move Time and Aggregate Time Notes:
       1. Trigger Threshold was configured to only capture client pulses. The pulses shown in the plots below
          have been determined to be from the Master AP.
       2. Marker Info and Aggregate time results are shown on the right side of the plots below.




                                           Figure 5-5. Band 2A Move Time and Aggregate Time




                                           Figure 5-6. Band 2C Move Time and Aggregate Time
                                                            FCC Pt. 15.407 DFS TEST REPORT       Reviewed by:
FCC ID: ZNFTP260
                                                                    (CERTIFICATION)              Quality Manager
Test Report S/N:             Test Dates:           EUT Type:
                                                                                                 Page 13 of 15
0Y1611071725.ZNF             11/08-11/16/2016      Portable Handset
 © 2016 PCTEST Engineering Laboratory, Inc.                                                                     V 5.0
                                                                                                          11/04/2016


         Figure 5-7. Band 2A Client Beacon Test – Monitoring live spectrum – Elapse time 10 minutes




         Figure 5-8. Band 2C Client Beacon Test – Monitoring live spectrum – Elapse time 10 minutes


                                                         FCC Pt. 15.407 DFS TEST REPORT    Reviewed by:
FCC ID: ZNFTP260
                                                                 (CERTIFICATION)           Quality Manager
Test Report S/N:             Test Dates:        EUT Type:
                                                                                           Page 14 of 15
0Y1611071725.ZNF             11/08-11/16/2016   Portable Handset
 © 2016 PCTEST Engineering Laboratory, Inc.                                                               V 5.0
                                                                                                    11/04/2016


 6.0 C O N C L U S I O N


 The data collected relate only to the item(s) tested and show that the LG Portable Handset
 FCC ID: ZNFTP260 is in compliance with the DFS requirements for a Client Device without radar detection in
 accordance with Part 15.407 of the FCC Rules.




                                                         FCC Pt. 15.407 DFS TEST REPORT      Reviewed by:
FCC ID: ZNFTP260
                                                                 (CERTIFICATION)             Quality Manager
Test Report S/N:             Test Dates:        EUT Type:
                                                                                             Page 15 of 15
0Y1611071725.ZNF             11/08-11/16/2016   Portable Handset
 © 2016 PCTEST Engineering Laboratory, Inc.                                                                 V 5.0
                                                                                                      11/04/2016



Document Created: 2017-12-20 00:18:25
Document Modified: 2017-12-20 00:18:25

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC