Test Report

FCC ID: ZNFQ620WA

Test Report

Download: PDF
FCCID_4491374

                                        PCTEST ENGINEERING LABORATORY, INC.
                                                        7185 Oakland Mills Road, Columbia, MD 21046 USA
                                                              Tel. 410.290.6652 / Fax 410.290.6654
                                                                      http://www.pctest.com

                                                               MEASUREMENT REPORT
                                                      FCC PART 15.225 / ISED RSS-210 NFC

    Applicant Name:                                                                              Date of Testing:
    LG Electronics USA, Inc.                                                                     9/12 - 10/2/2019
    1000 Sylvan Avenue                                                                           Test Site/Location:
    Englewood Cliffs, NJ 07632                                                                   PCTEST Lab. Columbia, MD, USA
    United States                                                                                Test Report Serial No.:
                                                                                                 1M1909120153-11-R1.ZNF


    FCC ID:                                                            ZNFQ620WA
    IC:                                                                2703C-Q620WA
    APPLICANT:                                                         LG Electronics USA, Inc.



    Application Type:                                                  Certification
    Model/HVIN:                                                        LM-Q620WA
    Additional Model(s)/HVIN(s):                                       LMQ620WA, Q620WA, LM-Q620VA, LMQ620VA, Q620VA,
                                                                       LM-Q620VL, LMQ620VL, Q620VL, LM-Q620QM6,
                                                                       LMQ620QM6, Q620QM6, LM-Q620QM, LMQ620QM, Q620QM
    EUT Type:                                                          Portable Handset
    Frequency:                                                         13.56MHz
    FCC Classification:                                                Low Power Communications Device Transmitter (DXX)
    FCC Rule Part(s):                                                  Part 15 Subpart C (15.225)
    ISED Specification:                                                RSS-210 Issue 9
    Test Procedure(s):                                                 ANSI C63.10-2013




    This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement
    report and was tested in accordance with the measurement procedures specified in ANSI C63.10-2013. Test results reported herein relate
    only to the item(s) tested.

    I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are
    correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the
    qualifications of all persons taking them.

    Note: This revised Test Report (S/N: 1M1909120153-11-R1.ZNF) supersedes and replaces the previously issued test report on the
    same subject device for the same type of testing as indicated. Please discard or destroy the previously issued test report(s) and
    dispose of it accordingly.




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 1 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                                               T A B L E                       O F             C O N T E N T S

        1.0         Introduction ...................................................................................................................................... 3
                    1.1      Scope..................................................................................................................................................... 3
                    1.2      PCTEST Test Location .......................................................................................................................... 3
                    1.3      Test Facility / Accreditations .................................................................................................................. 3
        2.0         PRODUCT INFORMATION ............................................................................................................. 4
                    2.1      Equipment Description ........................................................................................................................... 4
                    2.2      Device Capabilities ................................................................................................................................ 4
                    2.3      Test Configuration ................................................................................................................................. 4
                    2.4      EMI Suppression Device(s)/Modifications.............................................................................................. 4
        3.0         DESCRIPTION OF TEST ................................................................................................................ 5
                    3.1      Evaluation Procedure............................................................................................................................. 5
                    3.2      AC Line Conducted Emissions .............................................................................................................. 5
                    3.3      Radiated Emissions ............................................................................................................................... 6
                    3.4      Environmental Conditions ...................................................................................................................... 6
        4.0         ANTENNA REQUIREMENTS .......................................................................................................... 7
        5.0         MEASUREMENT UNCERTAINTY .................................................................................................. 8
        6.0         TEST EQUIPMENT CALIBRATION DATA ...................................................................................... 9
        7.0         TEST DATA ................................................................................................................................... 10
                    7.1      Summary ............................................................................................................................................. 10
                    7.2      Occupied Bandwidth Measurement ..................................................................................................... 11
                    7.3      Frequency Stability Test Data .............................................................................................................. 13
                    7.4      In-Band Radiated Spurious Emission Measurements .......................................................................... 16
                    7.5      Radiated Spurious Emission Measurements, Out-of-Band .................................................................. 19
                    7.6      Line Conducted Measurement Data .................................................................................................... 25
        8.0         CONCLUSION ............................................................................................................................... 28




                                                                                 MEASUREMENT REPORT                                                                Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                                Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                   Page 2 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


1.0              INTRODUCTION

1.1           Scope
Measurement and determination of electromagnetic emissions (EMC) of radio frequency devices including
intentional and/or unintentional radiators for compliance with the technical rules and regulations of the Federal
Communications Commission and the Innovation, Science and Economic Development Canada.

1.2           PCTEST Test Location
These measurement tests were conducted at the PCTEST Engineering Laboratory, Inc. facility located at 7185
Oakland Mills Road, Columbia, MD 21046. The measurement facility is compliant with the test site requirements
specified in ANSI C63.4-2014.

1.3           Test Facility / Accreditations
Measurements were performed at PCTEST Engineering Lab located in Columbia, MD 21046, U.S.A.

•     PCTEST is an ISO 17025-2005 accredited test facility under the American Association for Laboratory
      Accreditation (A2LA) with Certificate number 2041.01 for Specific Absorption Rate (SAR), Hearing Aid
      Compatibility (HAC) testing, where applicable, and Electromagnetic Compatibility (EMC) testing for FCC and
      Innovation, Science, and Economic Development Canada rules.

•     PCTEST TCB is a Telecommunication Certification Body (TCB) accredited to ISO/IEC 17065-2012 by A2LA
      (Certificate number 2041.03) in all scopes of FCC Rules and ISED Standards (RSS).

•     PCTEST facility is a registered (2451B) test laboratory with the site description on file with ISED.




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 3 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


2.0              PRODUCT INFORMATION


2.1           Equipment Description
The Equipment Under Test (EUT) is the LG Portable Handset FCC ID: ZNFQ620WA. The test data contained in
this report pertains only to the emissions due to the NFC transmitter of the EUT.

Test Device Serial No.: 08790

2.2           Device Capabilities
This device contains the following capabilities:

800/850/1900 CDMA/EvDO Rev0/A, 1x Advanced (BC0, BC1, BC10), 850/1900 GSM/GPRS/EDGE,
850/1700/1900 WCDMA/HSPA, Multi-band LTE, 802.11b/g/n/ac WLAN, 802.11a/n/ac UNII, Bluetooth (1x, EDR,
LE), NFC

2.3           Test Configuration
The EUT was set to continuously transmit at 13.56MHz. This was performed using manufacturer software loaded
on the phone and a passive RFID tag to allow for continuous transmission. This device was tested in accordance
with the guidance of ANSI C63.10-2013. See Sections 3.2 and 3.3 of this test report for a description of the AC line
conducted emissions and radiated emissions test setups, respectively.

2.4           EMI Suppression Device(s)/Modifications
No EMI suppression device(s) were added and no modifications were made during testing.




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 4 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


3.0              DESCRIPTION OF TEST

3.1           Evaluation Procedure
The measurement procedure described in the American National Standard of Procedures for Compliance Testing
of Unlicensed Wireless Devices (ANSI C63.10-2013) was used in the measurement of the EUT.

Deviation from measurement procedure…………………………………………….....................................None

3.2           AC Line Conducted Emissions
The line-conducted facility is located inside a 10'x16'x9' shielded enclosure. The shielded enclosure is manufactured
by ETS Lindgren RF Enclosures. The shielding effectiveness of the shielded room is in accordance with MIL-Std-
285 or NSA 65-5. A 1m x 1.5m wooden table 80cm high is placed 40cm away from the vertical wall and 80cm away
from the sidewall of the shielded room. Two 10kHz-30MHz, 50Ω/50µH Line-Impedance Stabilization Networks
(LISNs) are bonded to the shielded room floor. Power to the LISNs is filtered by external high-current high-insertion
loss power line filters. The external power line filter is an ETS Lindgren Model LPRX-4X30 (100dB Attenuation,
14kHz-18GHz) and the two EMI/RFI filters are ETS Lindgren Model LRW-2030-S1 (100dB Minimum Insertion Loss,
14kHz – 10GHz). These filters attenuate ambient signal noise from entering the measurement lines. These filters
are also bonded to the shielded enclosure.

The EUT is powered from one LISN and the support equipment is powered from the second LISN. If the EUT is a
DC-powered device, power will be derived from the source power supply it normally will be powered from and this
supply line(s) will be connected to the second LISN. All interconnecting cables more than 1 meter were shortened
to a 1 meter length by non-inductive bundling (serpentine fashion) and draped over the back edge of the test table.
All cables were at least 40cm above the horizontal reference groundplane. Power cables for support equipment
were routed down to the second LISN while ensuring that that cables were not draped over the second LISN.

Sufficient time for the EUT, support equipment, and test equipment was allowed in order for them to warm up to
their normal operating condition. The RF output of the LISN was connected to the spectrum analyzer and
exploratory measurements were made to determine the frequencies producing the maximum emission from the
EUT. The spectrum was scanned from 150kHz to 30MHz with a spectrum analyzer. The detector function was set
to peak mode for exploratory measurements while the bandwidth of the analyzer was set to 10kHz. The EUT,
support equipment, and interconnecting cables were arranged and manipulated to maximize each emission. Once
the worst case emissions have been identified, the one EUT cable configuration/arrangement and mode of
operation that produced these emissions is used for final measurements on the same test site. The analyzer is set
to CISPR quasi-peak and average detectors with a 9kHz resolution bandwidth for final measurements.

Line conducted emissions test results are shown in Section 7.6. The EMI Receiver mode of the Agilent MXE was
used to perform AC line conducted emissions testing.




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 5 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


3.3           Radiated Emissions
The radiated test facilities consisted of an indoor 3 meter semi-anechoic chamber used for final measurements and
exploratory measurements, when necessary. The measurement area is contained within the semi-anechoic
chamber which is shielded from any ambient interference. The test site inside the chamber is a 6m x 5.2m elliptical,
obstruction-free area in accordance with Figure 5.7 of Clause 5 in ANSI C63.4-2014. Absorbers are arranged on
the floor between the turn table and the antenna mast in such a way so as to maximize the reduction of reflections
for measurements above 1GHz. An 80cm tall test table made of Styrodur is placed on top of the turn table. For
measurements above 1GHz, an additional Styrodur pedestal is placed on top of the test table to bring the total table
height to 1.5m.

For all measurements, the spectrum was scanned through all EUT azimuths and from 1 to 4 meter receive antenna
height using a broadband antenna from 30MHz up to the upper frequency shown in 15.33 depending on the highest
frequency generated or used in the device or on which the device operates or tunes. For frequencies above 1GHz,
linearly polarized double ridge horn antennas were used. For frequencies below 30MHz, a calibrated loop antenna
was used. When exploratory measurements were necessary, they were performed at 1 meter test distance inside
the semi-anechoic chamber using broadband antennas, broadband amplifiers, and spectrum analyzers to
determine the frequencies and modes producing the maximum emissions. Sufficient time for the EUT, support
equipment, and test equipment was allowed in order for them to warm up to their normal operating condition. The
test set-up was placed on top of the 1 x 1.5 meter table. The EUT, support equipment, and interconnecting cables
were arranged and manipulated to maximize each emission. Appropriate precaution was taken to ensure that all
emissions from the EUT were maximized and investigated. The system configuration, mode of operation, turntable
azimuth, and receive antenna height was noted for each frequency found.

Final measurements were made in the semi-anechoic chamber using calibrated, linearly polarized broadband and
horn antennas. The test setup was configured to the setup that produced the worst case emissions. The spectrum
analyzer was set to investigate all frequencies required for testing to compare the highest radiated disturbances
with respect to the specified limits. The turntable containing the EUT was rotated through 360 degrees and the
height of the receive antenna was varied 1 to 4 meters and stopped at the azimuth and height producing the
maximum emission. Each emission was maximized by changing the orientation of the EUT through three orthogonal
planes and changing the polarity of the receive antenna, whichever produced the worst-case emissions.

3.4           Environmental Conditions
The temperature is controlled within range of 15oC to 35oC. The relative humidity is controlled within range of 10%
to 75%. The atmospheric pressure is monitored within the range 86-106kPa (860-1060mbar).




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 6 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


4.0           ANTENNA REQUIREMENTS

 Excerpt from §15.203 of the FCC Rules/Regulations:
 “An intentional radiator antenna shall be designed to ensure that no antenna other than that furnished by the
 responsible party can be used with the device. The use of a permanently attached antenna or of an antenna that
 uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this
 section.”


      •   The antenna of the EUT are permanently attached.

      •   This unit was tested with its standard battery.


 Conclusion:
 The EUT complies with the requirement of §15.203.




                                                                                  MEASUREMENT REPORT                                                              Approved by:
  FCC ID: ZNFQ620WA
                                                                                     (CERTIFICATION)                                                              Quality Manager
  Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                  Page 7 of 28
  1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
 © 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
 All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
 microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
 rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


5.0              MEASUREMENT UNCERTAINTY

The measurement uncertainties shown below were calculated in accordance with the requirements of
ANSI C63.10-2013. All measurement uncertainty values are shown with a coverage factor of k = 2 to indicate a
95% level of confidence. The measurement uncertainty shown below meets or exceeds the UCISPR measurement
uncertainty values specified in CISPR 16-4-2 and, thus, can be compared directly to specified limits to determine
compliance.


                                                  Contribution                                        Expanded Uncertainty (±dB)

                                      Line Conducted Disturbance                                                            3.09

                                    Radiated Disturbance (<1GHz)                                                            4.98




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 8 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


  6.0              TEST EQUIPMENT CALIBRATION DATA

Test Equipment Calibration is traceable to the National Institute of Standards and Technology (NIST).
Measurements antennas used during testing were calibrated in accordance to the requirements of ANSI C63.5-
2017.

     Manufacturer                      Model                                  Description                             Cal Date        Cal Interval       Cal Due        Serial Number
        Agilent                       N9038A                           MXE EMI Receiver                               7/17/2019         Annual           7/17/2020 MY51210133
     Com-Power                        AL-130                      9kHz - 30MHz Loop Antenna                          10/10/2017         Biennial        10/10/2019    121034
     Com-Power                       PAM-103                       Pre-Amplifier (1-1000MHz)                          5/10/2019         Annual           5/10/2020    441112
        Emco                           3115                         Horn Antenna (1-18GHz)                            3/28/2018         Biennial         3/28/2020  9704-5182
     ETS-Lindgren                   3816/2NM                 Line Impedance Stabilization Network                     6/18/2018         Biennial         6/18/2020    114451
   Rohde & Schwarz                    ESU26                       EMI Test Receiver (26.5GHz)                         6/5/2019          Annual           6/5/2020     100342
         Sunol                         JB5                        Bi-Log Antenna (30M - 5GHz)                         4/19/2018         Biennial         4/19/2020   A051107
                                             Table 6-1. Annual Test Equipment Calibration Schedule

  Note:

  For equipment listed above that has a calibration date or calibration due date that falls within the test date range,
  care was taken to ensure that this equipment was used after the calibration date and before the calibration due
  date.




                                                                                   MEASUREMENT REPORT                                                              Approved by:
   FCC ID: ZNFQ620WA
                                                                                      (CERTIFICATION)                                                              Quality Manager
   Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                   Page 9 of 28
   1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
  © 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
  All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
  microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
  rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.0              TEST DATA

7.1           Summary


            Company Name:                                   LG Electronics USA, Inc.
            FCC ID:                                         ZNFQ620WA
            FCC Classification:                             Low Power Communications Device Transmitter (DXX)
            Frequencies Examined:                           13.56MHz

    FCC Part                                                                                                                          Test                 Test
                         RSS Section(s)                  Test Description                            Test Limit                                                           Reference
    Section(s)                                                                                                                      Condition             Result

 2.1049                  RSS-Gen [6.6]              Occupied Bandwidth                      N/A                                                             PASS            Section 7.2

                                                                                            15,848µV/m @ 30m
                                                                                            13.553 – 13.567 MHz

                                                                                            334µV/m @ 30m
 15.225                                                                                      13.410 – 13.553 MHz
                         RSS-210 [B.6]              In-Band Emissions                                                                                       PASS            Section 7.4
 (a)(b)(c)                                                                                  13.567 – 13.710 MHz
                                                                                                                                    RADIATED
                                                                                            106µV/m @ 30m
                                                                                            13.110 – 13.410 MHz
                                                                                            13.710 – 14.010 MHz

                                                                                            Emissions outside of the
                                                                                            specified band (13.110 –
 15.225 (d)                                                                                 14.010 MHz) must meet
                         RSS-Gen [8.9]              Out-of-Band Emissions                                                                                   PASS            Section 7.5
 15.209                                                                                     the radiated limits
                                                                                            detailed in 15.209 (RSS-
                                                                                            Gen [8.9])

                                                    Frequency Stability                     ± 0.01% of Operating                   Temperature
 15.225 (e)              RSS-210 [B.6]                                                                                                                      PASS            Section 7.3
                                                    Tolerance                               Frequency                               Chamber


                                                    AC Conducted Emissions                  < FCC 15.207 limits                      LINE
 15.207                  RSS-Gen [8.8]                                                                                                                      PASS            Section 7.6
                                                    150kHz – 30MHz                          (RSS-Gen)                             CONDUCTED

                                                               Table 7-1. Summary of Test Results

Note:

This unit was tested with its standard battery.




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 10 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.2           Occupied Bandwidth Measurement
§2.1049; RSS-Gen (6.6)

Test Overview and Limit

The occupied bandwidth is measured with a spectrum analyzer connected to the receive antenna while the EUT is
operating in transmission mode at the appropriate frequency.

Test Procedure Used

ANSI C63.10-2013 – Section 6.9.3

Test Settings

      1. Spectrum analyzer frequency is set to the nominal EUT channel center frequency.

      2. RBW = 1 – 5% OBW

      3. VBW ≥ 3 x RBW

      4. Reference level set to keep signal from exceeding maximum input mixer level for linear operation.

      5. Detector = Peak

      6. Trace mode = max hold

      7. Sweep = auto couple

      8. The trace was allowed to stabilize

      9. Using the 99% power bandwidth function of the instrument and report the measured bandwidth.



Test Notes

None.




                                                                                                                     Agilent
                                                                EUT
                                                                                                                 Spectrum Analyzer


                                                  Figure 7-1. Test Instrument & Measurement Setup




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 11 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                                                      Frequency                                            Occupied Bandwidth

                                                      13.56 MHz                                                     1.8466 MHz
                                                      Table 7-2. Occupied Bandwidth Measurement




                                                              Figure 7-2. Occupied Bandwidth Plot




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 12 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.3           Frequency Stability Test Data
§15.225; RSS-210 (B.6)

Test Overview and Limit

Frequency stability testing is performed in accordance with the guidelines of ANSI C63.10-2013. The frequency
stability of the transmitter is measured by:

a.)       Temperature: The temperature is varied from -20°C to +50°C in 10°C increments using an environmental
          chamber.

b.)       Primary Supply Voltage: The primary supply voltage is varied from 85% to 115% of the nominal value for
          non hand-carried battery and AC powered equipment. For hand-carried, battery-powered equipment, primary
          supply voltage is reduced to the battery operating end point which shall be specified by the manufacturer.

For Part 15.225, the frequency stability of the transmitter shall be maintained within ±0.01% of the center
frequency.

Test Procedure Used

ANSI C63.10-2013 – Section 6.8

Test Settings

      1. The carrier frequency of the transmitter is measured at room temperature (20°C to provide a reference).
      2. The equipment is turned on in a “standby” condition for fifteen minutes before applying power to the
         transmitter. Measurement of the carrier frequency of the transmitter is made within one minute after
         applying power to the transmitter.
      3. Frequency measurements are made at 10°C intervals ranging from -20°C to +50°C. A period of at least
         one half-hour is provided to allow stabilization of the equipment at each temperature level.

Test Setup

The EUT was connected via an RF cable to a spectrum analyzer with the EUT placed inside an environmental
chamber.

Test Notes

None.




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 13 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Frequency Stability Test Data
§15.225; RSS-210 (B.6)



                           OPERATING FREQUENCY:                                            13,560,000                         Hz
                               REFERENCE VOLTAGE:                                                4.33                           VDC
                                          DEVIATION LIMIT:                             ± 0.01 % = 1356Hz


                              VOLTAGE                      POWER                TEMP              FREQUENCY                    Freq. Dev.             Deviation
                                                                                   o
                                (%)                         (VDC)                ( C)                (Hz)                         (Hz)                  (%)

                                 100 %                         4.33               - 30               13,560,020                        20            0.0001475
                                 100 %                                            - 20               13,559,920                       -80            -0.0005900
                                 100 %                                            - 10               13,559,833                      -167            -0.0012316
                                 100 %                                                 0             13,560,303                      303             0.0022345
                                 100 %                                           + 10                13,559,685                      -315            -0.0023230
                                 100 %                                           + 20                13,560,217                      217             0.0016003
                                 100 %                                            + 30               13,559,990                       -10            -0.0000737
                                 100 %                                           + 40                13,559,805                      -195            -0.0014381
                                 100 %                                           + 50                13,559,721                      -279            -0.0020576
                        BATT. ENDPOINT                         2.93              + 20                13,559,876                      -124            -0.0009145
                                                           Table 7-3. Frequency Stability Test Data




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 14 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Frequency Stability Test Data
§15.225; RSS-210 (B.6)


                                                                               Frequency Stability
                                                 0.03




                                                 0.02




                                                 0.01
                               Deviation (ppm)




                                                 0.00




                                                 -0.01




                                                 -0.02




                                                 -0.03




                                                                                       Temperature (°C)



                                                                      Figure 7-3. Frequency Stability Plot




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                                  Test Dates:            EUT Type:
                                                                                                                                                                 Page 15 of 28
 1M1909120153-11-R1.ZNF                            9/12 - 10/2/2019       Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.4           In-Band Radiated Spurious Emission Measurements
§15.225(a)(b)(c); RSS-210 (B.6)

Test Overview and Limit

The EUT was tested from 13.110 – 14.010 MHz. All in-band radiated spurious emissions are measured with a
spectrum analyzer connected to a loop antenna while the EUT is operating at appropriate frequencies. Only the
radiated emissions of the configuration that produced the worst case emissions are reported in this section.

All in-band emissions appearing in a restricted band as specified in Section 15.225 of the Title 47 CFR must
not exceed the limits shown in Table 7-4.


                                         Frequency                                  Field Strength                         Measured Distance
                                           [MHz]                                        [µV/m]                                 [Meters]

                                       13.553-13.567 MHz                                    15,848                                         30

                                   13.410-13.553 MHz and
                                                                                              334                                          30
                                     13.567-13.710 MHz

                                   13.110-13.410 MHz and
                                                                                              106                                          30
                                     13.710-14.010 MHz
                                                                       Table 7-4. Radiated Limits

Test Procedures Used

ANSI C63.10-2013 – Section 6.4.7

Test Settings

             1. RBW = 9kHz
             2. VBW ≥ 3 x RBW
             3. Detector = peak
             4. Sweep time = auto couple
             5. Trace mode = max hold
             6. Trace was allowed to stabilize




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 16 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Test Setup
The EUT and measurement equipment were set up as shown in the diagram below.




                                                                  Figure 7-4. Radiated Test Setup

Test Notes:

1. All emissions lying in restricted bands specified in §15.225 and RSS-210 are below the limit shown in Table
      7-4.
2. All measurements were performed using a loop antenna. The antenna was positioned in three orthogonal
      positions (X front, Y side, Z top) and the position with the highest emission level was recorded.
3. The EUT was positioned in three orthogonal planes to determine the orientation resulting in the worst case
       emissions.
4. Measurements were performed at 3m and the data was extrapolated to the specified measurement distance of
       30m using the square of an inverse linear distance extrapolation factor (40 dB/decade) as specified in
       §15.31(f)(2). Extrapolation Factor = 20 log10(30/3)2 = 40dB.
5. The spectrum was investigated from 9kHz up to 30MHz using the loop antenna. Only the emissions shown in
       the table below were found to be significant.
6. All measurements were recorded using a spectrum analyzer employing a quasi-peak detector.
7. The "-" shown in the following RSE tables are used to denote a noise floor measurement.

Sample Calculation

      o      Field Strength Level [dBµV/m] = Analyzer Level [dBm] + 107 + AFCL [dB/m]
      o      AFCL [dB/m] = Antenna Factor [dB/m] + Cable Loss [dB]
      o      Margin [dB] = Field Strength Level [dBµV/m] – Limit [dBµV/m]



                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 17 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


In-Band Radiated Spurious Emission Measurements
§15.225(a)(b)(c); RSS-210 (B.6)




             Frequency:                                           13.56MHz

             Measurement Distance:                                3 Meters


                          Ant. Antenna Turntable                                                                    3m Field
   Frequency                                                                     Level              AFCL                                Limit            Limit              Margin
                          Pol.   Height Azimuth                                                                    Strength
     [MHz]                                                                      [dBm]              [dB/m]                              [µV/m]          [dBµV/m]              [dB]
                         [X/Y/Z]  [cm]  [degree]                                                                   [dBµV/m]

       13.230                 X             100                 314              -89.10             15.28             33.18             106.00             40.51             -47.33

       13.420                 X             100                 314              -93.42             15.17             28.75             334.00             50.47             -61.73

       13.547                 X             100                 314              -87.34             15.09             34.75             334.00             50.47             -55.72

       13.560                 X             100                 314              -75.29             15.08             46.79           15848.00             84.00             -77.20

       13.570                 X             100                 314              -84.82             15.08             37.26             334.00             50.47             -53.22

       13.680                 X             100                 314              -92.80             15.02             29.22             334.00             50.47             -61.26

       13.810                 X             100                 314              -90.44             14.94             31.50             106.00             40.51             -49.00
                                                          Table 7-5. In-Band Radiated Measurements




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 18 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.5           Radiated Spurious Emission Measurements, Out-of-Band
§15.209 §15.225(d); RSS-Gen (8.9)

Test Overview and Limit

The EUT was tested from 9kHz up to the 1GHz excluding the band 13.110 – 14.010 MHz. All measurements up to
960MHz were recorded with a spectrum analyzer employing a quasi-peak detector.

All out-of-band emissions appearing in a restricted band as specified in Section 15.225 of the Title 47 CFR
must not exceed the limits shown in Table 7-6 per Section 15.209.

                                                                                  Field Strength                           Measured Distance
                                        Frequency
                                                                                      [µV/m]                                   [Meters]
                                   0.009 – 0.490 MHz                                 2400/F (kHz)                                        300
                                   0.490 – 1.705 MHz                                24000/F (kHz)                                         30
                                   1.705 – 30.00 MHz                                         30                                           30
                                   30.00 – 88.00 MHz                                        100                                            3
                                   88.00 – 216.0 MHz                                        150                                            3
                                   216.0 – 960.0 MHz                                        200                                            3
                                    Above 960.0 MHz                                         500                                            3
                                                           Table 7-6. Radiated Limits – Out of band

Test Procedures Used

ANSI C63.10-2013 – Section 6.5.4

Test Settings

             1. Analyzer center frequency was set to the frequency of the radiated spurious emission of interest
             2. RBW = 9kHz for emissions below 30MHz and 100kHz for emissions between 30MHz and 1GHz
             3. VBW ≥ 3 x RBW
             4. Detector = peak
             5. Sweep time = auto couple
             6. Trace mode = max hold
             7. Trace was allowed to stabilize




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 19 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Test Setup
The EUT and measurement equipment were set up as shown in the diagram below.




                                                          Figure 7-5. Radiated Test Setup < 30MHz




                                                          Figure 7-6. Radiated Test Setup > 30MHz




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 20 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Test Notes:

      1. All measurements were recorded using a spectrum analyzer employing a quasi-peak detector for emissions
             below 960MHz.
      2. A loop antenna was used to investigate emissions below 30MHz.
      3. Both Vertical and Horizontal polarities of the receive antenna were evaluated with the worst case emissions
             being reported. Below 30MHz the loop antenna was positioned in 3 orthogonal planes (X front, Y side, Z
             top) to determine the orientation resulting in the worst case emissions.
      4. The EUT was positioned in three orthogonal planes to determine the orientation resulting in the worst case
             emissions.
      5. The spectrum is measured from 9kHz to the 10th harmonic and the worst-case emissions are reported.
      6. No spurious emissions levels were found to be greater than the level of the fundamental.
      7. The "-" shown in the following RSE tables are used to denote a noise floor measurement.

Sample Calculation

o      Field Strength Level [dBµV/m] = Analyzer Level [dBm] + 107 + AFCL [dB/m]
o      AFCL [dB/m] = Antenna Factor [dB/m] + Cable Loss [dB]
o      Margin [dB] = Field Strength Level [dBµV/m] – Limit [dBµV/m]




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 21 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Radiated Spurious Emission Measurements, Out-of-Band
§15.209 §15.225(d); RSS-Gen (8.9)




                                              Plot 7-1. Radiated Spurious Plot 9kHz – 30MHz (Pol. X)




                                              Plot 7-2. Radiated Spurious Plot 9kHz – 30MHz (Pol. Y)




                                              Plot 7-3. Radiated Spurious Plot 9kHz – 30MHz (Pol. Z)


                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 22 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                                             Plot 7-4. Radiated Spurious Plot 30MHz – 1GHz (Pol. H)




                                             Plot 7-5. Radiated Spurious Plot 30MHz – 1GHz (Pol. V)




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 23 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Radiated Spurious Emission Measurements, Out-of-Band
§15.209 §15.225(d); RSS-Gen (8.9)


    Tx Frequency                                            13.56MHz

    Measurement Distance:                                   3 Meters


                                    Ant.         Antenna Turntable                                                          3m Field
            Frequency                                                                     Level             AFCL                       Limit                       Margin
                                    Pol.          Height  Azimuth                                                           Strength
              [MHz]                                                                      [dBm]             [dB/m]                    [dBµV/m]                       [dB]
                                   [H/V]           [cm]   [degree]                                                         [dBµV/m]

                 27.12                X                -                   -              -91.45             13.34             28.89              69.54             -40.66

                 40.68                V                 -                  -              -98.20             19.77             28.57              40.00             -11.43

                 54.24                V                 -                  -              -97.38             14.15             23.77              40.00             -16.23

                 67.80                V                 -                  -              -97.92             14.99             24.07              40.00             -15.93

                 81.36                V                 -                  -              -96.52             14.58             25.06              40.00             -14.94

                 94.92                V                 -                  -              -97.71             16.05             25.34              43.52             -18.19

                108.48                V                 -                  -              -97.68             19.37             28.69              43.52             -14.83
                                                                     Table 7-7. Radiated Measurements




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 24 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.6           Line Conducted Measurement Data
§15.207; RSS-Gen (8.8)

Test Overview and Limit

All AC line conducted spurious emissions are measured with a receiver connected to a grounded LISN while the
EUT is operating at its maximum duty cycle, at maximum power, and at the appropriate frequencies. All data rates
and modes were investigated for conducted spurious emissions. Only the conducted emissions of the configuration
that produced the worst case emissions are reported in this section.

All conducted emissions must not exceed the limits shown in the table below, per Section 15.207 and RSS-
Gen (8.8).



                             Frequency of emission                                              Conducted Limit (dBµV)
                                    (MHz)
                                                                                     Quasi-peak                                      Average
                                         0.15 – 0.5                                   66 to 56*                                      56 to 46*
                                           0.5 – 5                                       56                                             46
                                           5 – 30                                        60                                             50
                                                                     Table 7-8. Conducted Limits

*Decreases with the logarithm of the frequency.

Test Procedures Used

ANSI C63.10-2013, Section 6.2

Test Settings

             Quasi-Peak Field Strength Measurements

             1. Analyzer center frequency was set to the frequency of the spurious emission of interest
             2. RBW = 9kHz (for emissions from 150kHz – 30MHz)
             3. Detector = quasi-peak
             4. Sweep time = auto couple
             5. Trace mode = max hold
             6. Trace was allowed to stabilize
             Average Field Strength Measurements

             1. Analyzer center frequency was set to the frequency of the spurious emission of interest
             2. RBW = 9kHz (for emissions from 150kHz – 30MHz)
             3. Detector = RMS
             4. Sweep time = auto couple
             5. Trace mode = max hold
             6. Trace was allowed to stabilize



                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 25 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Test Setup

The EUT and measurement equipment were set up as shown in the diagram below.




                                                  Figure 7-7. Test Instrument & Measurement Setup

Test Notes

1.        All modes of operation were investigated and the worst-case emissions are reported using mid channel. The
          emissions found were not affected by the choice of channel used during testing.
2.        The limit for an intentional radiator from 150kHz to 30MHz are specified in 15.207 and RSS-Gen (8.8).
3.        Corr. (dB) = Cable loss (dB) + LISN insertion factor (dB)
4.        QP/AV Level (dBµV) = QP/AV Analyzer/Receiver Level (dBµV) + Corr. (dB)
5.        Margin (dB) = QP/AV Limit (dBµV) - QP/AV Level (dBµV)
6.        Traces shown in plot are made using a peak detector.
7.        Deviations to the Specifications: None.
8.        EUT was tested with the antenna terminated.




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 26 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                                                            Plot 7-6. Line-Conducted Test Plot (L1)




                                                             Plot 7-7. Line-Conducted Test Plot (N)



                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 27 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


8.0              CONCLUSION


   The        data       collected relate only to the item(s) tested                                          and       show         that the           LG Portable Handset
   FCC ID: ZNFQ620WA has been tested to show compliance with Part 15 Subpart C (15.225) of the FCC Rules
   and RSS-210 of the Innovation, Science and Economic Development Canada Rules.




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: ZNFQ620WA
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                      Test Dates:                     EUT Type:
                                                                                                                                                                 Page 28 of 28
 1M1909120153-11-R1.ZNF                9/12 - 10/2/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.