SAR test plots GSM850

FCC ID: ZNFP769

RF Exposure Info

Download: PDF
FCCID_1805735

Test Laboratory: UL CCS SAR Lab D                                                Date/Time: 8/22/2012

GSM850

Frequency: 836.6 MHz; Duty Cycle: 1:8;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                               3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.899 mho/m; εr = 42.4; ρ = 1000 kg/m ;
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 6/13/2012
- Probe: EX3DV4 - SN3749; ConvF(8.68, 8.68, 8.68); Calibrated: 1/27/2012
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM B (Twin); Type: SAM B; Serial: TP-105

Left Touch/Voice/Ch190/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.163 mW/g

Left Touch/Voice/Ch190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 13.7 V/m; Power Drift = -0.097 dB
Peak SAR (extrapolated) = 0.209 W/kg
SAR(1 g) = 0.150 mW/g; SAR(10 g) = 0.105 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.176 mW/g




                   0 dB = 0.176mW/g


Test Laboratory: UL CCS SAR Lab D                               Date/Time: 8/22/2012

GSM850
Frequency: 836.6 MHz; Duty Cycle: 1:8

Left Touch/Voice/Ch190/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.155 mW/g


Test Laboratory: UL CCS SAR Lab D                                               Date/Time: 8/22/2012

GSM850

Frequency: 836.6 MHz; Duty Cycle: 1:8;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                               3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.899 mho/m; εr = 42.4; ρ = 1000 kg/m ;
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 6/13/2012
- Probe: EX3DV4 - SN3749; ConvF(8.68, 8.68, 8.68); Calibrated: 1/27/2012
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used))Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: SAM B (Twin); Type: SAM B; Serial: TP-105

Left Tilt/Voice/Ch190/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.096 mW/g

Left Tilt/Voice/Ch190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 10.4 V/m; Power Drift = 0.020 dB
Peak SAR (extrapolated) = 0.103 W/kg
SAR(1 g) = 0.086 mW/g; SAR(10 g) = 0.067 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.095 mW/g




                   0 dB = 0.095mW/g


Test Laboratory: UL CCS SAR Lab D                                                Date/Time: 8/22/2012

GSM850

Frequency: 836.6 MHz; Duty Cycle: 1:8;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                               3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.899 mho/m; εr = 42.4; ρ = 1000 kg/m ;
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 6/13/2012
- Probe: EX3DV4 - SN3749; ConvF(8.68, 8.68, 8.68); Calibrated: 1/27/2012
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM B (Twin); Type: SAM B; Serial: TP-105

Right Touch/Voice/Ch190/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.159 mW/g

Right Touch/Voice/Ch190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 13.5 V/m; Power Drift = -0.007 dB
Peak SAR (extrapolated) = 0.172 W/kg
SAR(1 g) = 0.145 mW/g; SAR(10 g) = 0.110 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.158 mW/g




                   0 dB = 0.158mW/g


Test Laboratory: UL CCS SAR Lab D                                                Date/Time: 8/22/2012

GSM850

Frequency: 836.6 MHz; Duty Cycle: 1:8;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                               3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.899 mho/m; εr = 42.4; ρ = 1000 kg/m ;
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 6/13/2012
- Probe: EX3DV4 - SN3749; ConvF(8.68, 8.68, 8.68); Calibrated: 1/27/2012
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM B (Twin); Type: SAM B; Serial: TP-105

Right Tilt/Voice/Ch190/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.085 mW/g

Right Tilt/Voice/Ch190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 9.87 V/m; Power Drift = 0.086 dB
Peak SAR (extrapolated) = 0.095 W/kg
SAR(1 g) = 0.080 mW/g; SAR(10 g) = 0.063 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.088 mW/g




                   0 dB = 0.088mW/g


Test Laboratory: UL CCS SAR Lab D                                                Date/Time: 9/7/2012

GSM850

Frequency: 836.6 MHz; Duty Cycle: 1:4;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                              3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.91 mho/m; εr = 42.8; ρ = 1000 kg/m ;
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 6/13/2012
- Probe: EX3DV4 - SN3749; ConvF(8.68, 8.68, 8.68); Calibrated: 1/27/2012
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM A (Twin); Type: SAM A; Serial: 1050

Left Touch/GPRS 2 slots/Ch190/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.192 mW/g

Left Touch/GPRS 2 slots/Ch190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 14.7 V/m; Power Drift = 0.023 dB
Peak SAR (extrapolated) = 0.240 W/kg
SAR(1 g) = 0.177 mW/g; SAR(10 g) = 0.130 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.205 mW/g




                   0 dB = 0.205mW/g


Test Laboratory: UL CCS SAR Lab D                                               Date/Time: 9/7/2012 3:15:21 PM

GSM850

Frequency: 836.6 MHz; Duty Cycle: 1:4;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                              3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.91 mho/m; εr = 42.8; ρ = 1000 kg/m ;
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 6/13/2012
- Probe: EX3DV4 - SN3749; ConvF(8.68, 8.68, 8.68); Calibrated: 1/27/2012
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used))Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: SAM A (Twin); Type: SAM A; Serial: 1050

Left Tilt/GPRS 2 slots/Ch190/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.129 mW/g

Left Tilt/GPRS 2 slots/Ch190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 12.0 V/m; Power Drift = 0.024 dB
Peak SAR (extrapolated) = 0.140 W/kg
SAR(1 g) = 0.117 mW/g; SAR(10 g) = 0.092 mW/g
Info: Interpolated medium parameters used for SAR evaluation.




                   0 dB = 0.129mW/g


Test Laboratory: UL CCS SAR Lab D                                                Date/Time: 9/7/2012

GSM850

Frequency: 836.6 MHz; Duty Cycle: 1:4;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                              3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.91 mho/m; εr = 42.8; ρ = 1000 kg/m ;
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 6/13/2012
- Probe: EX3DV4 - SN3749; ConvF(8.68, 8.68, 8.68); Calibrated: 1/27/2012
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM A (Twin); Type: SAM A; Serial: 1050

Right Touch/GPRS 2 slots/Ch190/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.190 mW/g

Right Touch/GPRS 2 slots/Ch190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 14.8 V/m; Power Drift = -0.021 dB
Peak SAR (extrapolated) = 0.209 W/kg
SAR(1 g) = 0.180 mW/g; SAR(10 g) = 0.139 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.197 mW/g




                   0 dB = 0.197mW/g


Test Laboratory: UL CCS SAR Lab D                               Date/Time: 9/7/2012

GSM850
Frequency: 836.6 MHz; Duty Cycle: 1:4

Right Touch/GPRS 2 slots/Ch190/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm,
dz=5mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.200 mW/g


Test Laboratory: UL CCS SAR Lab D                                                Date/Time: 9/7/2012

GSM850

Frequency: 836.6 MHz; Duty Cycle: 1:4;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                              3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.91 mho/m; εr = 42.8; ρ = 1000 kg/m ;
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 6/13/2012
- Probe: EX3DV4 - SN3749; ConvF(8.68, 8.68, 8.68); Calibrated: 1/27/2012
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM A (Twin); Type: SAM A; Serial: 1050

Right Tilt/GPRS 2 slots/Ch190/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.120 mW/g

Right Tilt/GPRS 2 slots/Ch190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 11.7 V/m; Power Drift = -0.033 dB
Peak SAR (extrapolated) = 0.136 W/kg
SAR(1 g) = 0.115 mW/g; SAR(10 g) = 0.090 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.124 mW/g




                   0 dB = 0.124mW/g


Test Laboratory: UL CCS SAR Lab D                                                Date/Time: 8/21/2012

GSM850

Frequency: 836.6 MHz; Duty Cycle: 1:8;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                               3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.984 mho/m; εr = 53.5; ρ = 1000 kg/m ;
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 6/13/2012
- Probe: EX3DV4 - SN3749; ConvF(8.84, 8.84, 8.84); Calibrated: 1/27/2012
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM A (Twin); Type: SAM A; Serial: 1050

Rear/Voice/Ch190/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.523 mW/g

Rear/Voice/Ch190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 23.4 V/m; Power Drift = -0.096 dB
Peak SAR (extrapolated) = 0.627 W/kg
SAR(1 g) = 0.482 mW/g; SAR(10 g) = 0.356 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.547 mW/g




                   0 dB = 0.547mW/g


Test Laboratory: UL CCS SAR Lab D                               Date/Time: 8/21/2012

GSM850
Frequency: 836.6 MHz; Duty Cycle: 1:8

Rear/Voice/Ch190/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.517 mW/g


Test Laboratory: UL CCS SAR Lab D                                               Date/Time: 8/21/2012

GSM850

Frequency: 836.6 MHz; Duty Cycle: 1:8;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                               3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.984 mho/m; εr = 53.5; ρ = 1000 kg/m ;
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 6/13/2012
- Probe: EX3DV4 - SN3749; ConvF(8.84, 8.84, 8.84); Calibrated: 1/27/2012
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used))Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: SAM A (Twin); Type: SAM A; Serial: 1050

Rear with Headset/Voice/Ch190/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.440 mW/g

Rear with Headset/Voice/Ch190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 21.6 V/m; Power Drift = -0.006 dB
Peak SAR (extrapolated) = 0.534 W/kg
SAR(1 g) = 0.399 mW/g; SAR(10 g) = 0.287 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.461 mW/g




                   0 dB = 0.461mW/g


Test Laboratory: UL CCS SAR Lab D                                                Date/Time: 8/21/2012

GSM850

Frequency: 836.6 MHz; Duty Cycle: 1:8;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                               3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.984 mho/m; εr = 53.5; ρ = 1000 kg/m ;
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 6/13/2012
- Probe: EX3DV4 - SN3749; ConvF(8.84, 8.84, 8.84); Calibrated: 1/27/2012
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM A (Twin); Type: SAM A; Serial: 1050

Front/Voice/Ch190/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.300 mW/g

Front/Voice/Ch190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 17.8 V/m; Power Drift = -0.002 dB
Peak SAR (extrapolated) = 0.383 W/kg
SAR(1 g) = 0.256 mW/g; SAR(10 g) = 0.178 mW/g
Info: Interpolated medium parameters used for SAR evaluation.




                   0 dB = 0.300mW/g


Test Laboratory: UL CCS SAR Lab D                                                Date/Time: 8/21/2012

GSM850

Frequency: 836.6 MHz; Duty Cycle: 1:4;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                               3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.984 mho/m; εr = 53.5; ρ = 1000 kg/m ;
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 6/13/2012
- Probe: EX3DV4 - SN3749; ConvF(8.84, 8.84, 8.84); Calibrated: 1/27/2012
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM A (Twin); Type: SAM A; Serial: 1050

Rear/GPRS 2 slots/Ch190/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.628 mW/g

Rear/GPRS 2 slots/Ch190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 25.9 V/m; Power Drift = -0.031 dB
Peak SAR (extrapolated) = 0.761 W/kg
SAR(1 g) = 0.579 mW/g; SAR(10 g) = 0.427 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.664 mW/g




                   0 dB = 0.664mW/g


Test Laboratory: UL CCS SAR Lab D                               Date/Time: 8/21/2012

GSM850
Frequency: 836.6 MHz; Duty Cycle: 1:4

Rear/GPRS 2 slots/Ch190/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm

Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.636 mW/g


Test Laboratory: UL CCS SAR Lab D                                                Date/Time: 8/21/2012

GSM850

Frequency: 836.6 MHz; Duty Cycle: 1:4;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                               3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.984 mho/m; εr = 53.5; ρ = 1000 kg/m ;
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 6/13/2012
- Probe: EX3DV4 - SN3749; ConvF(8.84, 8.84, 8.84); Calibrated: 1/27/2012
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM A (Twin); Type: SAM A; Serial: 1050

Front/GPRS 2 slots/Ch190/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.362 mW/g

Front/GPRS 2 slots/Ch190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 19.6 V/m; Power Drift = 0.016 dB
Peak SAR (extrapolated) = 0.474 W/kg
SAR(1 g) = 0.312 mW/g; SAR(10 g) = 0.215 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.369 mW/g




                   0 dB = 0.369mW/g


Test Laboratory: UL CCS SAR Lab D                                               Date/Time: 8/21/2012

GSM850

Frequency: 836.6 MHz; Duty Cycle: 1:4;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                               3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.984 mho/m; εr = 53.5; ρ = 1000 kg/m ;
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 6/13/2012
- Probe: EX3DV4 - SN3749; ConvF(8.84, 8.84, 8.84); Calibrated: 1/27/2012
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used))Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: SAM A (Twin); Type: SAM A; Serial: 1050

Edge2/GPRS 2 slots/Ch190/Area Scan (7x13x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.421 mW/g

Edge2/GPRS 2 slots/Ch190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 20.6 V/m; Power Drift = 0.055 dB
Peak SAR (extrapolated) = 0.503 W/kg
SAR(1 g) = 0.363 mW/g; SAR(10 g) = 0.253 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.426 mW/g




                   0 dB = 0.426mW/g


Test Laboratory: UL CCS SAR Lab D                                                Date/Time: 8/21/2012

GSM850

Frequency: 836.6 MHz; Duty Cycle: 1:4;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                               3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.984 mho/m; εr = 53.5; ρ = 1000 kg/m ;
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 6/13/2012
- Probe: EX3DV4 - SN3749; ConvF(8.84, 8.84, 8.84); Calibrated: 1/27/2012
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM A (Twin); Type: SAM A; Serial: 1050

Edge3/GPRS 2 slots/Ch190/Area Scan (6x8x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.137 mW/g

Edge3/GPRS 2 slots/Ch190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 12.0 V/m; Power Drift = 0.133 dB
Peak SAR (extrapolated) = 0.199 W/kg
SAR(1 g) = 0.117 mW/g; SAR(10 g) = 0.066 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.152 mW/g




                   0 dB = 0.152mW/g


Test Laboratory: UL CCS SAR Lab D                                                Date/Time: 8/21/2012

GSM850

Frequency: 836.6 MHz; Duty Cycle: 1:4;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                               3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.984 mho/m; εr = 53.5; ρ = 1000 kg/m ;
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE3 Sn500; Calibrated: 6/13/2012
- Probe: EX3DV4 - SN3749; ConvF(8.84, 8.84, 8.84); Calibrated: 1/27/2012
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM A (Twin); Type: SAM A; Serial: 1050

Edge4/GPRS 2 slots/Ch190/Area Scan (7x13x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.162 mW/g

Edge4/GPRS 2 slots/Ch190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 13.1 V/m; Power Drift = 0.073 dB
Peak SAR (extrapolated) = 0.196 W/kg
SAR(1 g) = 0.140 mW/g; SAR(10 g) = 0.097 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.165 mW/g




                   0 dB = 0.165mW/g



Document Created: 2012-09-12 11:37:52
Document Modified: 2012-09-12 11:37:52

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC